一种无标记的生物发光scFv-NLuc融合探针,能够使用洛美沙星作为模型分析物,实现基于智能手机的灵敏免疫测定平台
A Label-Free Bioluminescent scFv-NLuc Fusion Probe Enabling a Smartphone-Based Sensitive Immunoassay Platform Using Lomefloxacin as a Model Analyte.
A Label-Free Bioluminescent scFv-NLuc Fusion Probe Enabling a Smartphone-Based Sensitive Immunoassay Platform Using Lomefloxacin as a Model Analyte.
酶作为标记试剂可增强侧流免疫分析(LFIA)的性能。然而,其生物学不稳定性以及对劳动密集型化学偶联的依赖,阻碍了其在食品污染物高通量筛查中的实际应用。为解决这一问题,我们报道了一种基于荧光素酶的快速、无标记平台,用于定量检测食品中的洛美沙星(LOM)。该检测采用一种工程化免疫探针:将特异性识别LOM的高亲和力单链可变片段抗体(3G9-scFv)与Nanoluciferase(NLuc)相结合,后者作为内在信号发生器,无需共价标记。NLuc催化furimazine氧化,产生稳定的生物发光,其强度与LOM浓度成反比。这种无标记设计消除了偶联变异性并简化了操作流程。基于智能手机的发光测量可实现灵敏的现场检测,定量限为0.12 ng/mL。此外,同源建模和分子对接阐明了3G9-scFv双功能的结构基础,验证了未标记酶示踪剂合理使用的可行性。视觉检测限为1 ng/mL。回收率范围为79.0%至113.0%,变异系数(CVs)在2.3%至10.9%之间,表明具有高准确度和重现性。该系统为食品安全中有害残留的监测提供了一种新型快速检测平台。
Enzymes as labeling agents enhance lateral flow immunoassays (LFIA). However, their biological instability and reliance on labor-intensive chemical conjugation hinder practical high-throughput screening of food contaminants. To address this, we report a rapid, label-free luciferase-based platform for quantifying lomefloxacin (LOM) in food. The assay uses an engineered immunoprobe: a high-affinity single-chain variable fragment antibody (3G9-scFv) specific to LOM, combined with Nanoluciferase (NLuc) as an intrinsic signal generator without covalent labeling. NLuc catalyzes furimazine oxidation, producing stable bioluminescence inversely proportional to LOM concentration. This label-free design eliminates conjugation variability and simplifies protocol execution. Smartphone-based luminescence measurement enables sensitive field detection, with a limit of quantification of 0.12 ng/mL. Furthermore, homology modeling and molecular docking elucidated the structural basis for the dual functionality of 3G9-scFv, validating the rational use of unlabeled enzymatic tracers. The visual detection limit was determined to be 1 ng/mL. Recovery rates ranged from 79.0% to 113.0%, with coefficients of variation (CVs) between 2.3% and 10.9%, indicating high accuracy and reproducibility. This system offers a novel rapid detection platform for monitoring hazardous residues in food safety.
Mingyue Ding, Hao Wen, Shixiang Wu, Shiyun Han, Linwei Zhang, Hongfei Yang, et al. A Label-Free Bioluminescent scFv-NLuc Fusion Probe Enabling a Smartphone-Based Sensitive Immunoassay Platform Using Lomefloxacin as a Model Analyte.. Small (Weinheim an der Bergstrasse, Germany). 2026; doi:10.1002/smll.75027.
Mingyue Ding, Hao Wen, Shixiang Wu, Shiyun Han, Linwei Zhang, Hongfei Yang, et al (2026). A Label-Free Bioluminescent scFv-NLuc Fusion Probe Enabling a Smartphone-Based Sensitive Immunoassay Platform Using Lomefloxacin as a Model Analyte.. Small (Weinheim an der Bergstrasse, Germany). https://doi.org/10.1002/smll.75027
Mingyue Ding, Hao Wen, Shixiang Wu, Shiyun Han, Linwei Zhang, Hongfei Yang, et al. A Label-Free Bioluminescent scFv-NLuc Fusion Probe Enabling a Smartphone-Based Sensitive Immunoassay Platform Using Lomefloxacin as a Model Analyte.[J]. Small (Weinheim an der Bergstrasse, Germany), 2026 doi:10.1002/smll.75027.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出