International Journal of Particle Therapy国际粒子治疗杂志
International Journal of Particle Therapy(英文缩写 INT J PART THER),ISSN 2331-5180,eISSN 2331-5180,中文译名:国际粒子治疗杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
International Journal of Particle Therapy 最新收录文献
-
1. Reirradiation With Proton Therapy Using Hypofractionated Schedules: A Systematic Review of the Literature.
1. 采用大分割方案的质子治疗再程放疗:文献系统综述PMID:日期:2026-09-14Re-irradiation (re-RT) with hypofractionated proton therapy (PT) may be a treatment option in selected cases. Aim is to provide a critical overview of the state of the art. PRISMA-compliant systematic review was performed on 2nd October 2025. All tumor sites were considered, provided that re-RT was performed with dose/fraction>2Gy(RBE) in adults. Oncological and toxicity outcomes were retrieved. Twelve original research works were identified. The total number of patients treated with hypofractionated PT re-RT was 478. The majority of patients were treated for recurrent tumors of either the gastrointestinal (GI) region ( = 143) or the lung ( = 123). The majority of the published series refers to data derived from retrospective and monoinstitutional experiences. Most patients were treated for recurrent tumors of either the gastrointestinal (GI) region ( = 143) or the lung ( = 123). Median sample size was 32 (interquartile range: 26-46, range: 14-83). Moderate hypofractionation (< 5 Gy(RBE)/fraction) was the most frequent schedule. All included studies had a radical intent. Overall, 2 year overall survival ranged from 8.4% (head & neck) to 87.5% (liver). The rate of severe side effects remained relevant. Of note, clinical outcomes and toxicity profiles were highly heterogeneous among the different tumor sites. Therefore, in the setting of re-RT with PT, conclusive data on the efficacy and toxicity profile of hypofractionated schedules could not be provided yet. Re-RT remains a personalized approach in almost all settings of tumor recurrence. Evidence supporting the use of hypofractionated PT re-RT remains limited but encouraging. Identifying predictors of toxicity and treatment response is essential to guide future research and to establish this approach as a viable option for selected patients.
-
2. Outcomes of Salvage Proton Therapy After Primary Cryosurgery or High-Intensity Focused Ultrasound for Recurrent Localized Prostate Cancer.
2. 原发性冷冻手术或高强度聚焦超声治疗后复发局限性前列腺癌的挽救性质子治疗结果PMID:日期:2026-09-04To report long-term outcomes for patients treated with salvage proton therapy (PT) following primary cryosurgery (CS) or high-intensity focused ultrasound (HIFU) for recurrent localized prostate cancer. We assessed 31 patients who underwent salvage PT at our institution between 2007 and 2017 for biopsy-confirmed, localized prostate cancer recurrence after CS ( = 21) or HIFU ( = 10). Patients had no evidence of nodal or distant metastases. Median PT dose was 74 CGE (range, 70.2-82) delivered at 1.8 to 2 CGE/fraction. Androgen deprivation therapy was administered to 12 patients for a median of 7 months (range, 6-24). Freedom from biochemical failure was defined per the Phoenix criteria. Freedom from regional failure and distant failure defined as the absence of radiologic or clinical evidence of metastatic disease in pelvic lymph nodes and distant to pelvic lymph nodes, respectively. Toxicities were graded using CTCAEV5. Patient-reported outcomes were assessed using the International Prostate Symptom Score and Expanded Prostate Index Composite. Kaplan-Meier estimates were used to calculate survival and oncologic outcomes. Median follow-up was 8.0 years (range, 1.9-13.5). The 5- and 10-year Freedom from biochemical failure rates were 72.4% and 64.7%, respectively. Overall survival at 5- and 10-year was 86.0% and 71.1%, respectively. At 10-years, freedom from regional failure was 73.7% and failure and distant failure was 96.8%. One late grade 3 hematuria occurred (3.2%), and 2 transient late grade 2 rectal hemorrhages occurred (6.4%). Median Expanded Prostate Index Composite and International Prostate Symptom Score scores remained stable from pre-PT through 5 years after treatment. Our results demonstrate salvage PT as a safe and effective option following CS or HIFU with low toxicity and minimal impact on reported quality of life. PT outcomes are comparable with recent prostate cancer ablation salvage reports. Future studies should include multi-center collaborations to investigate elective pelvic nodal radiation to optimize treatment strategies for recurrent prostate cancer.
-
3. Treatment Outcomes of Radiation Therapy of Paragangliomas of the Head and Neck at a Single Institution.
3. 单中心头颈部副神经节瘤放射治疗的治疗结果PMID:日期:2026-08-17Stereotactic radiosurgery and photon therapy for the locoregional management of head and neck paragangliomas (HNPGLs) have been shown to provide long-term tumor control and symptomatic relief. We report proton therapy (PT) outcomes for HNPGLs at a single institution and describe stereotactic radiosurgery (SRS) and intensity-modulated radiation therapy (IMRT) outcomes as institutional context for modality selection. The primary goal is to report outcomes including tumor control, toxicity, and overall recovery, while evaluating differences across radiation modalities. This is a retrospective review of 52 adult patients with 54 non-metastatic HNPGLs receiving radiation therapy in a single institution. There were 9 tumors treated with IMRT, 23 with SRS, and 22 with PT. Median dose was 45 Gy (cobalt Gray equivalent [CGE]). Out of 52 patients (14 male, 38 female) with a current median age of 65 (range 27-93), there were 30 jugular paragangliomas (PGLs), 1 tympanic PGL, 8 jugulotympanic PGLs, 3 vagal PGLs, 11 carotid body tumors, and 1 spinal PGL. The median age at the start of treatment was 59.5 years (range 18-85). Median follow-up was 50.3 months (range 3.6-147.2 months), with 52 (100%) patients alive at last follow-up. Local control, distant control, and overall survival were 98%, 100%, and 100%, respectively. No grade 3 to 5 toxicities were reported. At the end of follow-up, 53 (98%) tumors had a partial treatment response or were stable, and 20 (37%) experienced a decrease in volume. Of the 20 tumors that had a decrease in volume, 8 were treated with PT, 8 with SRS, and 4 with IMRT. PT was used more frequently for larger or anatomically complex tumors; SRS was preferred for small, well-circumscribed lesions; and IMRT was selected for moderate-sized or irregularly shaped tumors near critical structures before PT was available. PT was particularly useful in treating large or anatomically complex tumors, while SRS and IMRT offered strong outcomes for smaller or anatomically suitable lesions. We report favorable feasibility, local tumor control, survival, and toxicity of PT for HNPGLs.
-
4. Proton Therapy Utilization Among Adult Cancer Patients.
PMID:日期:2026-08-14Proton therapy (Pr) can spare normal tissue and reduce toxicity; however, it remains a limited resource. The aim of this study was to evaluate demographic and clinical differences in the use of Pr amongst adult cancer patients at a single institution, with particular attention to the impact of insurance coverage. Adult patients who underwent radiation between 2015 and 2021 were retrospectively reviewed. Multivariable (MVA) logistic regression analyses were used to assess associations between Pr use and variables including sex, sexual orientation, age, race, ethnicity, marital status, preferred language, smoking status, year of treatment, treatment intent, diagnosis, and distance to facility. Propensity score matching was then used to further validate associations between race and travel distance. Separately, Medicare-insured patients were considered an individual cohort and analyzed utilizing the same demographic variables noted. Of 12,320 patients identified, 2342 and 9978 received Pr and Photon therapy (Ph), respectively. On MVA, Black and Asian race, current smoker, and shorter straight-line distance to the facility remained associated with lower likelihood of treatment with Pr. On propensity-matched scoring, Black patients and patients living within 250 mi of the center remained significantly less likely to receive Pr. Of 4258 Medicare-only patients, 1261 and 2997 received Pr and Ph therapy, respectively. On MVA analysis, female sex, Black race, and decreasing distance to the facility were associated with lower likelihood of receiving Pr therapy On propensity-matched scoring, Black patients and patients living within 250 mi of the center remained significantly less likely to receive Pr. We identified significant differences in the use of Pr as a function of distance to site and race in both a heterogeneous adult patient cohort and a Medicare cohort. As health systems expand Pr therapy capacity, understanding how clinico-demographic factors shape access, even under conditions of broad insurance coverage, may inform future infrastructure planning.
-
5. Artificial Intelligence in Particle Therapy Treatment Planning: Current Advances and Future Directions.
5. 粒子治疗计划中的人工智能:当前进展与未来方向PMID:日期:2026-08-13This review examines the role of artificial intelligence (AI) in particle therapy treatment planning, highlighting recent advancements, clinical potential, and existing challenges. A review was conducted on AI applications in proton and heavy ion therapy, focusing on automated plan generation, dose prediction, treatment adaptation, and quality assurance. AI-driven methods have shown promise in optimizing treatment planning, enhancing dose prediction, and improving plan adaptation. However, challenges such as data limitations, model interpretability, and regulatory barriers hinder clinical implementation. While AI offers significant potential to improve particle therapy treatment planning, further research is needed to enhance model robustness, clinical validation, and integration into existing workflows.
-
6. A Target-Specific, "Eco-Friendly" Experimental Setup for Small Field Proton Irradiation.
6. 一种针对特定靶点的、面向小照射野质子辐照的“环境友好型”实验装置PMID:日期:2026-08-11Increasing interest in proton FLASH radiotherapy has led to a focus on target-specific (TS) devices and passive scattering (PS) techniques. However, these techniques often require expensive, time-consuming custom devices like single-use collimators and compensators. Our study aims to improve this by creating a flexible TS-PS setup adaptable to various needs, specifically for small target structures. The collimating and compensating elements are made from 3D-printed polylactide containers filled with reusable copper or polypropylene spheres. We designed these TSPS elements using the modified Python package Porespy and conducted simulations in Tool for Particle Simulation Monte Carlo. We evaluated the collimator's performance by comparing a solid collimator with our proposed approach. As a feasibility study, we developed 2 "eco-friendly" PS setups for irradiating a simple spherical target and a complex small structure, a murine brain tumor. We validated the computational model and MC simulations through depth dose curve and beam size measurements, demonstrating an agreement within a few percent. The "eco-friendly" collimators effectively collimated the beam, but we observed a dose halo at high energies due to protons not being stopped by the plastic bore; using higher-density materials can address this issue. We designed and validated the 2 "eco-friendly" setups via dose measurements and demonstrated that we could effectively compensate and collimate the beam to conform the dose to the target shape. The total time required to print the setup was under 45 minutes, and the filament cost was under $1. This innovative, "eco-friendly" approach using 3D printing allows for quick production of TS shapes, reducing waste and costs while enhancing conformity and improving the efficiency of PS treatments.
-
7. Patient-Specific Deep Reinforcement Learning for Proton Beam Delivery Under Inter-Phase Variations.
7. 针对相位间变化下质子束输送的患者特定深度强化学习PMID:日期:2026-07-22Proton therapy is challenged by tumor motion, particularly for lung tumors affected by respiratory-induced motion. Conventional planning strategies compensate for this motion by introducing safety margins or by using robust optimization, increasing irradiation of surrounding healthy tissues. Real-time plan adaptation during delivery represents a promising alternative to mitigate intrafractional motion effects. We propose a patient-specific deep Reinforcement Learning (RL)-based control framework for proton pencil beam scanning, formulated as a first step toward a real-time plan adaptation problem under respiratory motion. RL agents are trained independently on 3 patients on their mid-position planning CT to sequentially control beam position and spot delivery. At inference, the learned policy is executed on the respiratory phases of each patient's 4DCT without any online re-training or model parameters adaptation. The agent is provided with 2D observations encoding target geometry, beam position, and prior spot delivery. The approach is evaluated against conventional static gross tumor volume-based (GTV-based) and internal target volume-based (ITV-based) planning strategies. The agents improve target coverage under respiratory motion by exploiting new information in the observations during delivery compared with static gross tumor volume-based plans, with an average gain of 4.54 Gy in over the whole treatment for Patient 1. Compared with ITV-based plans, the RL-based approach generally reduces dose exposure to organ-at-risk, with an average reduction of 0.42, 4.12, and 3.14 Gy in D for the 3 patients, respectively, and a decrease of 1.41 Gy in D for Patient 3, who has the largest motion amplitude. This study should be interpreted as a proof-of-concept and highlights the potential of RL-based control strategies for proton therapy delivery under intrafractional motion. While the current framework relies on static training, it establishes a foundation for future extensions toward fully dynamic and adaptive treatments.
-
8. Clinical Comparison of Beam-Specific Planning Target Volume Single-Field Uniform Dose and Robust Intensity-Modulated Proton Therapy in Ultra-Hypofractionation for Prostate Cancer.
8. 前列腺癌超低分割中束特异性计划靶体积单野均匀剂量与稳健调强质子治疗的临床比较PMID:日期:2026-07-15[中文摘要] 本研究旨在比较基于束特异性计划靶区(bs-PTV)的单野均匀剂量(SFUD)与稳健优化调强质子治疗(IMPT)计划在局限性前列腺癌超大分割(UHF)质子治疗中对抗摆位、射程和解剖学不确定性的稳健性。利用本机构连续十例接受前列腺癌质子治疗患者的影像数据集,生成并比较了SFUD与IMPT计划。SFUD计划采用bs-PTV,IMPT计划采用稳健优化,均给予临床靶区(CTV)36.25 Gy当量(GyE),分5次照射。为评估对抗摆位和射程不确定性的稳健性,应用了20种误差场景,包括±3 mm等中心移位与±3.5%亨斯菲尔德单位(HU)变化的组合。此外,利用每周锥形束CT(wCBCT)衍生的虚拟CT(vCT)重新计算SFUD和IMPT计划,以估算解剖学变化下的累积剂量。比较了CTV、直肠和膀胱的最差情况剂量和累积剂量。SFUD和IMPT计划在摆位、射程和解剖学不确定性下均表现出稳定的靶区覆盖。所有患者CTV D99的变化均保持在普遍接受的稳健性标准范围内。尽管SFUD与IMPT计划之间最差情况CTV D99差异具有统计学显著性,但差异幅度较小。IMPT中选定危及器官(OAR)剂量指标在不确定性下的剂量变化较小。在名义、最差情况和累积剂量评估中,IMPT计划对直肠和膀胱的低剂量和中剂量指标均较低。基于bs-PTV的SFUD和稳健优化IMPT计划在前列腺癌UHF质子治疗中均能在不确定性下维持足够的靶区覆盖。IMPT观察到的较低OAR剂量和略优的OAR稳健性可能反映了计划技术和不确定性管理策略差异的综合效应,提示具有适度的剂量学优势。
[英文摘要] This study aimed to compare the robustness of beam-specific planning target volume (bs-PTV)-based single-field uniform dose (SFUD) and robustly optimized intensity-modulated proton therapy (IMPT) plans against setup, range, and anatomical uncertainties in ultra-hypofractionated (UHF) proton therapy for localized prostate cancer. SFUD and IMPT plans were generated and compared using imaging datasets from ten consecutive patients who underwent proton therapy for prostate cancer at our institution. SFUD plans using a bs-PTV and IMPT plans using robust optimization were generated with 36.25 Gy equivalent (GyE) to the clinical target volume (CTV) in 5 fractions. To evaluate robustness against setup and range uncertainties, 20 error scenarios were applied, including combined ±3 mm isocenter shifts and ±3.5% Hounsfield Unit (HU) variations. Additionally, the SFUD and IMPT plans were recalculated using virtual CT (vCT) derived from weekly cone-beam CT (wCBCT) to estimate accumulated doses under anatomical changes. The worst-case and accumulated doses to the CTV, rectum, and bladder were compared. Both SFUD and IMPT plans demonstrated stable target coverage under setup, range, and anatomical uncertainties. Variations in CTV D99 remained within commonly accepted robustness criteria for all patients. Although a statistically significant difference in worst-case CTV D99 was observed between SFUD and IMPT plans, the magnitude of this difference was small. Dose variations under uncertainties were smaller for selected organs at risk (OAR) dose metrics in IMPT. Across the nominal, worst-case, and accumulated dose evaluations, IMPT plans achieved lower low- and intermediate-dose metrics for the rectum and bladder. Both bs-PTV-based SFUD and robustly optimized IMPT plans maintained adequate target coverage under uncertainties in UHF proton therapy for prostate cancer. The lower OAR doses and slightly improved OAR robustness observed with IMPT likely reflect the combined effects of differences in planning techniques and uncertainty management strategies, suggesting a modest dosimetric benefit.
-
9. Evaluations of Penumbra Reduction Using Multi-Leaf Collimator and 3D Bolus in Scanned Proton Therapy.
9. 扫描质子治疗中多叶准直器与三维组织补偿物减少半影的评估PMID:日期:2026-07-10[中文摘要] 质子治疗能够提供优异的远端组织保护;然而,精确控制侧向半影对于保护邻近健康组织至关重要。本研究系统评估了在质子笔形束扫描(PBS)中,使用表面接触式三维打印补偿物(3DBS)相较于采用机头安装式距离移位器(RS)的传统计划,在有和无多叶准直器(MLC)条件下对侧向半影的改善效果。共生成460个均匀剂量PBS计划,靶区为立方体(60×60×54 mm³),置于水中0至280 mm范围内的9个不同深度。计划配置包括使用3种不同材料(硅胶、树脂和热塑性聚氨酯)的3DBS计划,并与使用聚乙烯RS的计划进行比较。每种配置进一步分为有和无MLC的计划。评估了50至300 mm范围内的气隙。评估了侧向半影宽度及30 mm边缘内周围危及器官(OARs)的平均剂量。使用二维电离室阵列和辐射变色胶片对选定束流的二维剂量分布进行了实验验证。在等效MLC条件下,与RS计划相比,所有使用3DBS的计划均改善了侧向半影并降低了OAR平均剂量,例外情况为深度大于200 mm且气隙极小的少数计划。实测剂量分布与计算计划显示出可接受的一致性。3种3DBS材料之间的比较表明,根据所需补偿物几何形状和临床实施考虑进行材料选择是可行的。MLC与3DBS的联合使用为质子PBS中的侧向半影控制提供了一种系统且有效的策略。该方法可在临床敏感场景中提高剂量学精度,在这些场景中即使周围组织剂量的微小降低也至关重要。
[英文摘要] Proton therapy offers excellent distal tissue sparing; however, precise control of the lateral penumbra is critical for protecting adjacent healthy tissues. This study systematically evaluated improvements in lateral penumbra in proton pencil beam scanning (PBS) using a surface-contacted 3-dimensional printed bolus (3DBS), compared with conventional plans employing a nozzle-mounted range shifter (RS), for beams with and without a multi-leaf collimator (MLC). A total of 460 uniform-dose PBS plans were generated for a cubic target (60 × 60 × 54 mm³) positioned at 9 different depths ranging from 0 to 280 mm in water. Plan configurations included plans with 3 different materials for 3DBSs (silicone, resin, and thermoplastic polyurethane) and were compared with plans with a polyethylene RS. Each configuration was further subdivided into plans with and without MLC. Air gaps ranging from 50 to 300 mm were evaluated. Lateral penumbra widths and mean doses to surrounding organs at risk (OARs) within a 30-mm margin were evaluated. Two-dimensional dose distributions for selected beams were experimentally verified using a 2D ionization chamber array and radiochromic films. All plans with 3DBSs improved lateral penumbra and reduced mean OAR doses compared with plans with RS, under equivalent MLC conditions, except for a limited subset of plans at depths greater than 200 mm with minimal air gaps. Measured dose distributions demonstrated acceptable agreement with calculated plans. Comparisons among the 3 3DBS materials indicated feasibility in material selection based on required bolus geometry and clinical implementation considerations. The combined use of MLC and 3DBS provides a systematic and effective strategy for lateral penumbra control in proton PBS. This approach enables improved dosimetric precision in clinically sensitive scenarios where even small reductions in dose to surrounding tissues are critical.
-
10. Dosimetric Comparison Between Brass Aperture-Enhanced Proton Pencil Beam Scanning and Photon Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations.
10. 黄铜孔径增强质子笔形束扫描与光子立体定向放射外科治疗脑动静脉畸形的剂量学比较PMID:日期:2026-07-06[中文摘要] 本研究旨在量化一种新型黄铜准直器增强的质子立体定向放射外科(SRS)技术,与传统光子直线加速器SRS相比,在脑动静脉畸形(AVMs)患者中潜在的剂量学优势。本研究对本机构2023年至2025年间接受质子SRS治疗脑AVMs的患者进行了回顾性分析。生成容积旋转调强放疗直线加速器SRS计划用于剂量学比较,并归一化以匹配所实施质子计划的临床靶体积(CTV)处方覆盖率。SRS计划质量通过放射治疗肿瘤学组适形性和均匀性指数(CI、HI)进行评估。测量V12 Gy,即包括CTV在内的正常脑组织(全脑)接受≥12 Gy照射的体积。共纳入14例患者,大多数无既往出血史(64%)、栓塞史(79%)或针对AVM的放疗史(86%)。3例患者接受了分阶段放疗,共计17个治疗计划纳入分析。AVM平均大小为8.8 cc(0.4-30.6)。SRS剂量范围为17至20 Gy,3例较大AVM采用容积分阶段治疗。对于4例≤2.0 cc的AVM,光子和质子的平均CI分别为1.89和1.81。对于>2 cc的AVM,光子和质子的平均CI分别为1.15和1.17。HI(= .0034)和V12 Gy(= .0017)差异具有统计学意义。17个计划中有14个(82.4%)质子HI更低。质子平均改善V12 Gy 5.86 cc。黄铜准直器增强质子笔形束扫描(PBS)SRS在17个计划中的15个(88.2%)改善了V12 Gy,包括小体积AVM和靠近脑干的AVM。这些发现具有假设生成性,必须谨慎解读。随着我们临床结局数据(AVM闭塞率和症状性放射性坏死率)的成熟,将获得进一步的认识。
[英文摘要] The current study aimed to quantify potential dosimetric advantages of a novel, brass aperture-enhanced, proton-based stereotactic radiosurgery (SRS) technique compared to conventional photon linac-based SRS in patients with cerebral arteriovenous malformations (AVMs). A retrospective review was performed of patients treated with proton SRS for cerebral AVMs at our institution between 2023 and 2025. Volumetric modulated arc therapy linac-based SRS plans were generated for dosimetric comparison and normalized to match the clinical target volume (CTV) prescription coverage of the delivered proton plan. SRS plan quality was evaluated by Radiation Therapy Oncology Group conformity and homogeneity indices (CI, HI). The V12 Gy representing the normal brain volume receiving ≥ 12 Gy including the CTV (total brain) was measured. Fourteen patients were included, and most had no prior hemorrhage (64%), embolization (79%), or AVM-directed radiotherapy (86%). Three patients received staged radiation, totaling 17 treatment plans for review. Mean AVM size was 8.8 cc (0.4-30.6). SRS dose ranged from 17 to 20 Gy with 3 larger AVMs treated using volumetric staging. For the 4 AVMs ≤2.0 cc in size, the average CI was 1.89 and 1.81 for photons and protons, respectively. The average CI for AVMs >2 cc was 1.15 and 1.17 for photons and protons, respectively. A statistically significant difference was observed with HI ( = .0034) and V12 Gy ( = .0017). Fourteen of 17 (82.4%) HI were lower with protons. There was on average a 5.86 cc improvement in V12 Gy with protons. Brass aperture-enhanced proton PBS SRS improved V12 Gy in 15 of 17 plans (88.2%), including small volume AVMs and AVMs close to the brainstem. These findings are hypothesis-generating and must be interpreted cautiously. Maturation of our clinical outcome data (AVM obliteration and symptomatic radionecrosis rates) will yield further insights.