本研究旨在量化一种新型黄铜准直器增强的质子立体定向放射外科(SRS)技术,与传统光子直线加速器SRS相比,在脑动静脉畸形(AVMs)患者中潜在的剂量学优势。本研究对本机构2023年至2025年间接受质子SRS治疗脑AVMs的患者进行了回顾性分析。生成容积旋转调强放疗直线加速器SRS计划用于剂量学比较,并归一化以匹配所实施质子计划的临床靶体积(CTV)处方覆盖率。SRS计划质量通过放射治疗肿瘤学组适形性和均匀性指数(CI、HI)进行评估。测量V12 Gy,即包括CTV在内的正常脑组织(全脑)接受≥12 Gy照射的体积。共纳入14例患者,大多数无既往出血史(64%)、栓塞史(79%)或针对AVM的放疗史(86%)。3例患者接受了分阶段放疗,共计17个治疗计划纳入分析。AVM平均大小为8.8 cc(0.4-30.6)。SRS剂量范围为17至20 Gy,3例较大AVM采用容积分阶段治疗。对于4例≤2.0 cc的AVM,光子和质子的平均CI分别为1.89和1.81。对于>2 cc的AVM,光子和质子的平均CI分别为1.15和1.17。HI(= .0034)和V12 Gy(= .0017)差异具有统计学意义。17个计划中有14个(82.4%)质子HI更低。质子平均改善V12 Gy 5.86 cc。黄铜准直器增强质子笔形束扫描(PBS)SRS在17个计划中的15个(88.2%)改善了V12 Gy,包括小体积AVM和靠近脑干的AVM。这些发现具有假设生成性,必须谨慎解读。随着我们临床结局数据(AVM闭塞率和症状性放射性坏死率)的成熟,将获得进一步的认识。

Abstract

The current study aimed to quantify potential dosimetric advantages of a novel, brass aperture-enhanced, proton-based stereotactic radiosurgery (SRS) technique compared to conventional photon linac-based SRS in patients with cerebral arteriovenous malformations (AVMs). A retrospective review was performed of patients treated with proton SRS for cerebral AVMs at our institution between 2023 and 2025. Volumetric modulated arc therapy linac-based SRS plans were generated for dosimetric comparison and normalized to match the clinical target volume (CTV) prescription coverage of the delivered proton plan. SRS plan quality was evaluated by Radiation Therapy Oncology Group conformity and homogeneity indices (CI, HI). The V12 Gy representing the normal brain volume receiving ≥ 12 Gy including the CTV (total brain) was measured. Fourteen patients were included, and most had no prior hemorrhage (64%), embolization (79%), or AVM-directed radiotherapy (86%). Three patients received staged radiation, totaling 17 treatment plans for review. Mean AVM size was 8.8 cc (0.4-30.6). SRS dose ranged from 17 to 20 Gy with 3 larger AVMs treated using volumetric staging. For the 4 AVMs ≤2.0 cc in size, the average CI was 1.89 and 1.81 for photons and protons, respectively. The average CI for AVMs >2 cc was 1.15 and 1.17 for photons and protons, respectively. A statistically significant difference was observed with HI ( = .0034) and V12 Gy ( = .0017). Fourteen of 17 (82.4%) HI were lower with protons. There was on average a 5.86 cc improvement in V12 Gy with protons. Brass aperture-enhanced proton PBS SRS improved V12 Gy in 15 of 17 plans (88.2%), including small volume AVMs and AVMs close to the brainstem. These findings are hypothesis-generating and must be interpreted cautiously. Maturation of our clinical outcome data (AVM obliteration and symptomatic radionecrosis rates) will yield further insights.

如何引用

AMA

Will Sperduto, Mattison J Flakus, Ed Clouser, Sujay A Vora, Jonathan B Ashman, Fan Yang, et al. Dosimetric Comparison Between Brass Aperture-Enhanced Proton Pencil Beam Scanning and Photon Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations.. International journal of particle therapy. 2026; doi:10.1016/j.ijpt.2026.101948.

APA

Will Sperduto, Mattison J Flakus, Ed Clouser, Sujay A Vora, Jonathan B Ashman, Fan Yang, et al (2026). Dosimetric Comparison Between Brass Aperture-Enhanced Proton Pencil Beam Scanning and Photon Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations.. International journal of particle therapy. https://doi.org/10.1016/j.ijpt.2026.101948

GB/T 7714

Will Sperduto, Mattison J Flakus, Ed Clouser, Sujay A Vora, Jonathan B Ashman, Fan Yang, et al. Dosimetric Comparison Between Brass Aperture-Enhanced Proton Pencil Beam Scanning and Photon Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations.[J]. International journal of particle therapy, 2026 doi:10.1016/j.ijpt.2026.101948.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

International journal of particle therapy 的其他文献