扫描质子治疗中多叶准直器与三维组织补偿物减少半影的评估
Evaluations of Penumbra Reduction Using Multi-Leaf Collimator and 3D Bolus in Scanned Proton Therapy.
Evaluations of Penumbra Reduction Using Multi-Leaf Collimator and 3D Bolus in Scanned Proton Therapy.
质子治疗能够提供优异的远端组织保护;然而,精确控制侧向半影对于保护邻近健康组织至关重要。本研究系统评估了在质子笔形束扫描(PBS)中,使用表面接触式三维打印补偿物(3DBS)相较于采用机头安装式距离移位器(RS)的传统计划,在有和无多叶准直器(MLC)条件下对侧向半影的改善效果。共生成460个均匀剂量PBS计划,靶区为立方体(60×60×54 mm³),置于水中0至280 mm范围内的9个不同深度。计划配置包括使用3种不同材料(硅胶、树脂和热塑性聚氨酯)的3DBS计划,并与使用聚乙烯RS的计划进行比较。每种配置进一步分为有和无MLC的计划。评估了50至300 mm范围内的气隙。评估了侧向半影宽度及30 mm边缘内周围危及器官(OARs)的平均剂量。使用二维电离室阵列和辐射变色胶片对选定束流的二维剂量分布进行了实验验证。在等效MLC条件下,与RS计划相比,所有使用3DBS的计划均改善了侧向半影并降低了OAR平均剂量,例外情况为深度大于200 mm且气隙极小的少数计划。实测剂量分布与计算计划显示出可接受的一致性。3种3DBS材料之间的比较表明,根据所需补偿物几何形状和临床实施考虑进行材料选择是可行的。MLC与3DBS的联合使用为质子PBS中的侧向半影控制提供了一种系统且有效的策略。该方法可在临床敏感场景中提高剂量学精度,在这些场景中即使周围组织剂量的微小降低也至关重要。
Proton therapy offers excellent distal tissue sparing; however, precise control of the lateral penumbra is critical for protecting adjacent healthy tissues. This study systematically evaluated improvements in lateral penumbra in proton pencil beam scanning (PBS) using a surface-contacted 3-dimensional printed bolus (3DBS), compared with conventional plans employing a nozzle-mounted range shifter (RS), for beams with and without a multi-leaf collimator (MLC). A total of 460 uniform-dose PBS plans were generated for a cubic target (60 × 60 × 54 mm³) positioned at 9 different depths ranging from 0 to 280 mm in water. Plan configurations included plans with 3 different materials for 3DBSs (silicone, resin, and thermoplastic polyurethane) and were compared with plans with a polyethylene RS. Each configuration was further subdivided into plans with and without MLC. Air gaps ranging from 50 to 300 mm were evaluated. Lateral penumbra widths and mean doses to surrounding organs at risk (OARs) within a 30-mm margin were evaluated. Two-dimensional dose distributions for selected beams were experimentally verified using a 2D ionization chamber array and radiochromic films. All plans with 3DBSs improved lateral penumbra and reduced mean OAR doses compared with plans with RS, under equivalent MLC conditions, except for a limited subset of plans at depths greater than 200 mm with minimal air gaps. Measured dose distributions demonstrated acceptable agreement with calculated plans. Comparisons among the 3 3DBS materials indicated feasibility in material selection based on required bolus geometry and clinical implementation considerations. The combined use of MLC and 3DBS provides a systematic and effective strategy for lateral penumbra control in proton PBS. This approach enables improved dosimetric precision in clinically sensitive scenarios where even small reductions in dose to surrounding tissues are critical.
Yuki Tominaga, Robabeh Rahimi, Yushi Wakisaka, Mayu Nakata, Yuya Miyasaka, Akira Takagi, et al. Evaluations of Penumbra Reduction Using Multi-Leaf Collimator and 3D Bolus in Scanned Proton Therapy.. International journal of particle therapy. 2026; doi:10.1016/j.ijpt.2026.101950.
Yuki Tominaga, Robabeh Rahimi, Yushi Wakisaka, Mayu Nakata, Yuya Miyasaka, Akira Takagi, et al (2026). Evaluations of Penumbra Reduction Using Multi-Leaf Collimator and 3D Bolus in Scanned Proton Therapy.. International journal of particle therapy. https://doi.org/10.1016/j.ijpt.2026.101950
Yuki Tominaga, Robabeh Rahimi, Yushi Wakisaka, Mayu Nakata, Yuya Miyasaka, Akira Takagi, et al. Evaluations of Penumbra Reduction Using Multi-Leaf Collimator and 3D Bolus in Scanned Proton Therapy.[J]. International journal of particle therapy, 2026 doi:10.1016/j.ijpt.2026.101950.