JACC-Cardiovascular InterventionsJACC-心血管介入
JACC-Cardiovascular Interventions(英文缩写 JACC-CARDIOVASC INTE),ISSN 1936-8798,eISSN 1876-7605,中文译名:JACC-心血管介入 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 11.075 | Q1 |
| 2022 | 11.300 | Q1 |
| 2023 | 11.700 | Q1 |
| 2024 | 11.400 | Q1 |
| 2025 | 12.700 | Q1 |
JACC-Cardiovascular Interventions 最新收录文献
-
1. Clinical Performance and Reproducibility of the LIRA Method for TAVR in Bicuspid Anatomy: The SUBLIME Study.
1. LIRA法在二叶式解剖结构中经导管主动脉瓣置换术的临床性能与可重复性:SUBLIME研究PMID:日期:2026-09-28Transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) anatomy remains challenging, with heterogeneous outcomes and no standardized sizing strategy. The LIRA (level of implantation at the raphe) method is a bicuspid-dedicated approach that complements standard annular sizing with a single perimeter measurement at the raphe level. A previous single-center experience suggested favorable results. The aim of this study was to evaluate clinical performance and reproducibility of the LIRA method for TAVR sizing in a large BAV multicenter cohort. A total of 215 BAV patients undergoing TAVR with the LIRA method at 6 centers were retrospectively analyzed. Procedural and clinical outcomes were adjudicated according to Valve Academic Research Consortium 3 criteria and assessed at 30 days and 1 year. Available full-cycle computed tomographic data sets from external centers were reanalyzed in a blinded centralized core laboratory to assess reproducibility of the LIRA method. The application of the LIRA method led to prosthesis downsizing in 74.4% of cases. At 30 days, device success was 93%, and moderate or greater paravalvular leak had occurred in 4.6% of patients, new permanent pacemaker implantation in 10.7%, and stroke in 1.9%. At 1 year, all-cause mortality was 5.7%, and clinical efficacy was observed in 92.8% of patients. Clinical outcomes were consistent across centers. Prosthesis sizing agreement was excellent (κ = 0.85; 95% CI: 0.74-0.96), and perimeter concordance was good (intraclass correlation coefficient = 0.76; 95% CI: 0.63-0.85). In this large multicenter cohort, the LIRA method demonstrated good reproducibility across centers and was associated with favorable procedural and clinical outcomes in BAV patients undergoing TAVR. These findings support its clinical applicability as a bicuspid-dedicated sizing strategy.
-
2. Residual Mitral Regurgitation as a Long-Term Predictor of Mortality After Mitral TEER.
2. 残余二尖瓣反流作为二尖瓣TEER术后远期死亡率的预测因素PMID:日期:2026-09-28The MITRA-PRO registry revealed residual mitral regurgitation (MR) as an important predictor of 1-year and 3-year mortality following mitral transcatheter edge-to-edge repair (M-TEER). The 5-year follow-up of the MITRA-PRO registry (N = 1,491) aimed to assess the impact of residual MR on 5-year mortality. Furthermore, time-dependent predictors of mortality after M-TEER should be assessed. Patients with a MitraScore of ≤3 were classified as patients with mild residual MR after M-TEER, while a MitraScore of ≥4 was defined as relevant residual MR. Adjusted HRs were calculated for multivariate analysis of time-dependent predictors. Five-year mortality was significantly lower in patients with mild or less residual MR compared with patients with more than mild residual MR (MitraScore ≤3 group: 55.1% vs MitraScore ≥4 group: 67.7%). The relationship between intraprocedural MitraScore after M-TEER and mortality was almost linear. In patients with degenerative MR, 5-year mortality was 53.1% in the MitraScore ≤3 group and 73.2% in the MitraScore ≥4 group. Regarding functional MR, the corresponding 5-year mortality rates were 55.0% and 64.6%. Mortality predictors after M-TEER were time dependent: Early risk was driven by advanced disease and procedural factors, whereas residual MR became prognostic after 30 days and remained associated with excess long-term mortality. Residual MR assessed by intraprocedural MitraScore after M-TEER independently predicts 5-year mortality. This finding underscores the importance of achieving optimal MR reduction during M-TEER and supports quantitative multimodal intraprocedural assessment to guide strategy and improve long-term outcomes.
-
3. Stenting Technique and Clinical Outcome in True Bifurcation PCI: Insights From the OCTOBER Trial.
3. 真性分叉病变PCI中的支架置入技术与临床结局:来自OCTOBER试验的启示PMID:日期:2026-09-28Optimal stenting for true coronary bifurcation lesions is widely debated, with few studies using predefined intracoronary imaging. The aim of this study was to assess predictors and outcomes associated with a 1 vs a 2-stent technique and whether optical coherence tomographic (OCT) guidance modified the association with clinical outcomes. This OCTOBER (European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction; NCT03171311) post hoc analysis included 1,201 patients with true coronary bifurcation treated with percutaneous coronary intervention (PCI). Clinical outcomes were analyzed using multivariable Cox regression. Multivariable logistic regression identified predictors of a 2-stent technique. Clinical indication, left main coronary artery (LMCA) bifurcation, and side branch (SB) lesion severity were the strongest predictors of 2-stent use (acute clinical presentation: adjusted OR: 1.73 [95% CI: 1.33-2.25]; LMCA: adjusted OR: 2.04 [95% CI: 1.38-3.03]; SB lesion length: adjusted OR: 1.06 per mm [95% CI: 1.03-1.09]; SB diameter stenosis: adjusted OR: 1.04 per 1% [95% CI: 1.03-1.05]). In as-treated analysis, a 1-stent technique was associated with a lower 2-year rate of major adverse cardiac events (MACE) than a 2-stent technique (9.0% vs 13.9%; adjusted HR: 1.53; 95% CI: 1.04-2.27), with no interaction with OCT (P for interaction = 0.24). Planned-strategy analyses showed no significant difference in MACE. Among patients treated with a double kissing (DK)-crush technique, angiography-guided DK crush was associated with higher MACE rates compared with OCT-guided DK-crush (HR: 2.42; 95% CI: 1.12-5.24). Clinical indication, LMCA bifurcation, and SB disease severity predicted 2-stent PCI. MACE did not differ according to planned strategy, whereas actual 2-stent PCI had higher MACE rates, likely reflecting a higher burden of complexity. The lowest event rates were observed with OCT-guided 1-stent PCI.
-
4. A Proposed Common Language to Harmonize Valve-in-Valve TAVR (TAV-in-SAV and TAV-in-TAV) Procedural Planning.
4. 一种拟议的共同语言以协调瓣中瓣TAVR(TAV-in-SAV和TAV-in-TAV)手术规划PMID:日期:2026-09-17该文献暂无摘要。
-
5. Side Branch Intervention or Not for Non Left Main Provisional Stenting: Technique Selection Matters.
5. 非左主干临时支架置入术中是否干预分支:技术选择至关重要PMID:日期:2026-09-14该文献暂无摘要。
-
6. Reply: EuroTR Risk Score: Methodological and Clinical Considerations.
6. 回复:EuroTR风险评分:方法与临床考量PMID:日期:2026-09-14该文献暂无摘要。
-
7. EuroTR Risk Score: Methodological and Clinical Considerations.
7. EuroTR风险评分:方法与临床考量PMID:日期:2026-09-14该文献暂无摘要。
-
8. Dual‑Imaging Biopsy With Angioscopy and Intracardiac Echocardiography for Cardiac Metastatic Squamous Cell Carcinoma.
8. 血管镜与心腔内超声心动图双成像活检用于心脏转移性鳞状细胞癌PMID:日期:2026-09-14该文献暂无摘要。
-
9. Kissing Balloon Technique for a Protruded Left Main Stent During Transcatheter Aortic Valve Replacement.
9. 经导管主动脉瓣置换术中左主干支架突出的球囊对吻技术PMID:日期:2026-09-14该文献暂无摘要。
-
10. Bronchial Artery Perforation From Transradial Catheterization Treated With Coil Embolization.
10. 经桡动脉导管插入术导致的支气管动脉穿孔采用弹簧圈栓塞治疗PMID:日期:2026-09-14该文献暂无摘要。