一种柔性纸基微针阵列电化学传感器,用于在护理点检测间质液中的CEA

A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

癌胚抗原(CEA)检测对于癌症早期诊断和预后监测至关重要。然而,传统的CEA检测主要基于血液样本,具有侵入性,且不利于即时检验(POCT)。因此,本研究开发了一种柔性纸基微针(MN)阵列电化学传感器,集成便携式电子设备和移动应用程序,用于检测组织间液(ISF)中的CEA。该微针阵列由紫外固化生物相容性树脂与微晶纤维素的复合材料制成,制备于浸渍柔性紫外固化树脂的纸基基底上。通过修饰导电油墨、rGO/Thi/AuNPs纳米复合材料和抗CEA抗体,将微针阵列功能化为电化学传感器以检测CEA。通过体外和体内实验验证了微针阵列电化学传感器的性能,该传感器表现出高灵敏度、良好的选择性、较宽的线性范围、稳健的稳定性,且与参考方法具有高度一致性。本研究为CEA监测提供了新工具,并为开发用于POCT的微创生物标志物检测设备提供了新思路。

Abstract

Carcinoembryonic antigen (CEA) detection is crucial for early cancer diagnosis and prognostic monitoring. However, traditional CEA detection is mainly based on blood samples, which is invasive and less conducive to point-of-care testing (POCT). Therefore, in this study, we developed a flexible paper-based microneedle (MN) array electrochemical sensor, integrated with portable electronics and a mobile application, to detect CEA in interstitial fluid (ISF). The MN array was fabricated from a composite of UV-curable biocompatible resin and microcrystalline cellulose on a paper substrate impregnated with flexible UV-curable resin. The MN array was functionalized as an electrochemical sensor to detect CEA by modification with conductive ink, rGO/Thi/AuNPs nanocomposites and anti-CEA antibodies. The performance of the MN array electrochemical sensor was validated through in vitro and in vivo experiments, and the sensor demonstrated high sensitivity, good selectivity, broad linear ranges, robust stability, and strong concordance with reference methods. This study provides a new tool for CEA monitoring and offers new insights into the development of minimally invasive biomarker detection devices for POCT.

如何引用

AMA

Yue Jin, Joseph Benjamin Holman, Qigui Yu, Xiangyu Chen, Shuohui Sun, Yi Hu, et al. A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.119066.

APA

Yue Jin, Joseph Benjamin Holman, Qigui Yu, Xiangyu Chen, Shuohui Sun, Yi Hu, et al (2026). A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.119066

GB/T 7714

Yue Jin, Joseph Benjamin Holman, Qigui Yu, Xiangyu Chen, Shuohui Sun, Yi Hu, et al. A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.119066.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biosensors & bioelectronics 的其他文献