相变BSA和环肽防污界面用于未稀释血清中超灵敏PD-L1检测

Phase-transited BSA and cyclic-peptide antifouling interface for ultrasensitive PD-L1 detection in undiluted serum.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

可溶性程序性死亡配体1(sPD-L1)是一种颇具前景的无创生物标志物,可用于癌症早期诊断和免疫治疗监测。然而,由于严重的生物污染会损害灵敏度和特异性,血清中sPD-L1的电化学检测仍面临挑战。我们通过共组装相变牛血清白蛋白(PTB)和环状多功能肽(CP),开发了一种一步式双抗污染电化学界面。PTB形成致密的类淀粉样纳米膜,作为坚固的蛋白质屏障,而CP则引入两性离子抗污染环和PD-L1结合基序。这种协同结构显著抑制了非特异性蛋白质吸附,同时实现了定向靶标识别。该传感器实现了37.4 pg/mL的检测限,并能够使用未经稀释或预处理的纯血清准确区分癌症患者与健康个体。PTB/CP双抗污染平台为sPD-L1检测提供了一种简单、灵敏且具有临床转化潜力的策略,在即时癌症诊断和免疫监测方面具有广阔的应用前景。

Abstract

Soluble programmed death-ligand 1 (sPD-L1) is a promising non-invasive biomarker for early cancer diagnosis and immunotherapy monitoring. However, electrochemical detection of sPD-L1 in serum remains challenging due to severe biofouling that compromises sensitivity and specificity. We developed a one-step, dual-antifouling electrochemical interface by co-assembling phase-transited bovine serum albumin (PTB) and a cyclic multifunctional peptide (CP). PTB forms a dense, amyloid-like nanofilm that acts as a robust protein shield, while CP introduces a zwitterionic antifouling loop and a PD-L1-binding motif. This synergistic architecture significantly suppresses non-specific protein adsorption while enabling oriented target recognition. The sensor achieves a detection limit of 37.4 pg/mL and accurately distinguishes cancer patients from healthy individuals using neat serum without dilution or pretreatment. The PTB/CP dual-antifouling platform offers a simple, sensitive, and clinically translatable strategy for sPD-L1 detection, with broad potential for point-of-care cancer diagnostics and immune monitoring.

如何引用

AMA

Junjie Xia, Jiarong Cao, Jiaying Pu, Qiang Xie, Zhongzheng Zhu, Kwangnak Koh, et al. Phase-transited BSA and cyclic-peptide antifouling interface for ultrasensitive PD-L1 detection in undiluted serum.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.119119.

APA

Junjie Xia, Jiarong Cao, Jiaying Pu, Qiang Xie, Zhongzheng Zhu, Kwangnak Koh, et al (2026). Phase-transited BSA and cyclic-peptide antifouling interface for ultrasensitive PD-L1 detection in undiluted serum.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.119119

GB/T 7714

Junjie Xia, Jiarong Cao, Jiaying Pu, Qiang Xie, Zhongzheng Zhu, Kwangnak Koh, et al. Phase-transited BSA and cyclic-peptide antifouling interface for ultrasensitive PD-L1 detection in undiluted serum.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.119119.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biosensors & bioelectronics 的其他文献