利用纳米酶的pH稳定性在侧流免疫测定中进行低背景信号放大

Exploiting pH stability of nanozymes for low-background signal amplification in lateral flow immunoassays.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

纳米酶以其在极端pH条件下的卓越稳定性而著称,然而这一特性从未被用于克服实际分析中的局限性。在此,我们首次利用其极端耐酸性来解决免洗分析中长期存在的挑战——由内源性过氧化物酶引起的背景信号。通过在pH 1.0条件下进行原位信号放大,我们选择性地使天然过氧化物酶失活,同时保留Au@Pt纳米酶足够的催化活性,从而无需额外洗涤步骤即可消除假阳性信号。我们将该策略应用于侧流免疫分析(LFIA),使用单克隆抗体和纳米抗体检测菠菜中百草枯,该基质具有高内源性过氧化物酶活性。在标准pH条件下,强烈的背景干扰阻碍了可靠的视觉判读。相比之下,低pH放大完全抑制了基质诱导的背景,显著提高了信噪比,并实现了常规方案无法达到的检测限(60 pg/mL),百草枯回收率令人满意,为90–130%。这项工作在生物传感和化学工程领域建立了一种新的设计范式:与其回避苛刻条件,不如有目的地利用它们来获得对生物背景的选择性。

Abstract

Nanozymes are known for their exceptional stability under extreme pH conditions, yet this property has never been exploited to overcome practical analytical limitations. Here, we report the first utilization of the extreme acid tolerance to address a long-standing challenge in wash-free assays - background signal caused by endogenous peroxidases. By performing in situ signal amplification at pH 1.0, we selectively inactivate natural peroxidases while preserving sufficient catalytic activity of Au@Pt nanozyme, thereby eliminating false-positive signals without additional washing steps. We applied this strategy to lateral flow immunoassay (LFIA) using monoclonal antibodies and nanobodies for the detection of paraquat in spinach characterized by high endogenous peroxidase activity. Under standard pH conditions, strong background interference prevented reliable visual readout. In contrast, low-pH amplification completely suppressed matrix-induced background, significantly improved the signal-to-noise ratio, and enabled detection limits (60 pg/mL) unachievable with conventional protocols and yielded satisfactory paraquat recoveries of 90-130% This work establishes a new design paradigm in biosensing and chemical engineering: instead of avoiding harsh conditions, they can be served on purpose to gain selectivity against biological background.

如何引用

AMA

Vasily G Panferov, Nadezhda A Byzova, Chuanlai Xu, Hongtao Lei, Zhen-Lin Xu, Anatoly V Zherdev, et al. Exploiting pH stability of nanozymes for low-background signal amplification in lateral flow immunoassays.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.119125.

APA

Vasily G Panferov, Nadezhda A Byzova, Chuanlai Xu, Hongtao Lei, Zhen-Lin Xu, Anatoly V Zherdev, et al (2026). Exploiting pH stability of nanozymes for low-background signal amplification in lateral flow immunoassays.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.119125

GB/T 7714

Vasily G Panferov, Nadezhda A Byzova, Chuanlai Xu, Hongtao Lei, Zhen-Lin Xu, Anatoly V Zherdev, et al. Exploiting pH stability of nanozymes for low-background signal amplification in lateral flow immunoassays.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.119125.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biosensors & bioelectronics 的其他文献