光开关CRISPR电化学系统实现抗干扰生物传感信号输出

Photo-switchable CRISPR electrochemical system enables de-interferential biosensing signal output.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

大多数基于成簇规律间隔短回文重复序列(CRISPR)的电化学生物传感器缺乏可控开关功能,且易受固有扩增信号串扰所导致的假信号影响。因此,探索能够通过精确开关减轻固有扩增串扰的策略,对于可靠且准确的生物分析极为有用。在此,我们通过引入光可裂解(PC)连接子并采用光响应策略,开发了一种光开关CRISPR/Cas12a电化学(PSCE)系统,该系统能够输出去干扰的电化学信号,并实现对非小细胞肺癌(NSCLC)基因突变的高灵敏、准确检测。该系统将核酸扩增(NAA)与信号转导解耦,并通过光照激活Cas12a活性产生独特的光开关响应信号。该架构设计进一步将信号读出与样本预处理分离,抑制固有扩增衍生的信号串扰而非全局生物干扰,从而实现超低检测限(LoD)。在67例临床样本测试中,PSCE达到98.1%的灵敏度、92.7%的特异性和98.9%的总准确率。此外,PSCE系统在柔性可穿戴电子设备中的探索以及对临床患者样本的机器学习分析,显示出在突变相关疾病临床诊断中的显著应用潜力。

Abstract

Most clustered regularly interspaced short palindromic repeats (CRISPR)-based electrochemical biosensors lack controllable switching function and are vulnerable to false signals induced by intrinsic amplification signal crosstalk. Thus, exploring strategies that mitigate intrinsic amplification crosstalk with a precise switch would be extremely useful for reliable and accurate bioanalysis. Herein, we develop a photo-switchable CRISPR/Cas12a electrochemical (PSCE) system by introducing a photocleavable (PC) linker and adopting a light-responsive strategy, which enables output of de-interference electrochemical signals and achieves highly sensitive and accurate detection of gene mutations for non-small cell lung cancer (NSCLC). The system decouples nucleic acid amplification (NAA) from signal transduction and produces unique photo-switchable response signals by light irradiation to activate Cas12a activity. This architectural design further separates signal readout from sample pretreatment, suppressing intrinsic amplification-derived signal crosstalk rather than global biological interference to deliver an ultralow limit of detection (LoD). The PSCE achieves 98.1% sensitivity, 92.7% specificity, and 98.9% overall accuracy when tested with 67 clinical samples. Moreover, the exploration of PSCE system in flexible wearable electronics and machine-learning analysis of clinical patient samples demonstrates significant application potential clinical diagnosis of mutation-associated diseases.

如何引用

AMA

Junhong Zhao, Jinghang He, Huanyu Du, Changhao Dai, Xinye Ma, Derong Kong, et al. Photo-switchable CRISPR electrochemical system enables de-interferential biosensing signal output.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.119067.

APA

Junhong Zhao, Jinghang He, Huanyu Du, Changhao Dai, Xinye Ma, Derong Kong, et al (2026). Photo-switchable CRISPR electrochemical system enables de-interferential biosensing signal output.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.119067

GB/T 7714

Junhong Zhao, Jinghang He, Huanyu Du, Changhao Dai, Xinye Ma, Derong Kong, et al. Photo-switchable CRISPR electrochemical system enables de-interferential biosensing signal output.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.119067.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biosensors & bioelectronics 的其他文献