用于多重尿细胞外囊泡表型和机器学习辅助疾病分层的邻近限制性DNA行走纳米酶级联
Proximity-confined DNA walking-nanozyme cascades for multiplexed urinary extracellular vesicle phenotyping and machine learning-assisted disease stratification.
Proximity-confined DNA walking-nanozyme cascades for multiplexed urinary extracellular vesicle phenotyping and machine learning-assisted disease stratification.
尿液细胞外囊泡(uEVs)能够反映疾病相关的分子改变,因而为液体活检提供了非侵入性生物标志物。然而,在复杂生物基质中准确分析低丰度uEV表面蛋白仍是一项重大的分析挑战。在此,我们报道了一种邻近激活双级联(PADC)生物传感平台,该平台将靶标响应型三维DNA机器与纳米酶介导的比率型转导回路相整合,用于uEV的高保真多重表型分析。在对靶标uEV进行双重识别后,DNA机器在单个磁性颗粒上发生邻近诱导的空间限域,形成局部催化微环境,显著增强DNA步行动力学和信号放大效率。结合酶-纳米酶氧化还原级联,该限域催化过程产生稳健的比率型荧光输出,实现灵敏可靠的分子谱分析。得益于空间限域的放大架构,所提出的平台能够对CD63、EGFR和PAK6进行超灵敏多重分析,检测限分别低至4.3×10、2.2×10和1.7×10颗粒/mL。重要的是,靶标uEV响应比常见尿液干扰物或其混合物产生的响应高约六倍,证明其在复杂尿液基质中具有高分析选择性。为进一步评估其用于多疾病筛查的普适性,我们对采集自健康对照、糖尿病(DM)患者和前列腺癌(PCa)患者的临床uEV样本进行了多维分子谱分析并结合机器学习算法。最优分类模型在区分健康、DM和PCa组方面实现了91%的总体多分类诊断准确率。本工作建立了一种用于多重uEV分析的邻近限域催化生物传感策略,并展示了其在基于uEV的液体活检和概念验证性疾病的分子分型方面的潜力。
Urinary extracellular vesicles (uEVs) provide noninvasive biomarkers for liquid biopsy owing to their ability to reflect disease-associated molecular alterations. However, the accurate analysis of low-abundance uEV surface proteins in complex biological matrices remains a major analytical challenge. Here, we report a proximity-activated dual-cascade (PADC) biosensing platform that integrates a target-responsive 3D DNA machine with a nanozyme-mediated ratiometric transduction circuit for high-fidelity multiplexed phenotyping of uEVs. Upon dual-recognition of target uEVs, the DNA machine undergoes proximity-induced spatial confinement on individual magnetic particles, creating a localized catalytic microenvironment that markedly enhances DNA walking kinetics and signal amplification efficiency. Coupled with an enzyme-nanozyme redox cascade, this confined catalytic process generates a robust ratiometric fluorescence output for sensitive and reliable molecular profiling. Benefiting from the spatially confined amplification architecture, the proposed platform enables ultrasensitive multiplexed analysis of CD63, EGFR, and PAK6 with detection limits down to 4.3 × 10, 2.2 × 10, and 1.7 × 10 particles/mL, respectively. Importantly, the target-uEV response was approximately six-fold higher than those generated by common urinary interferents or their mixture, demonstrating high analytical selectivity in complex urine matrices. To further evaluate its universality for multi-disease screening, multidimensional molecular profiling combined with machine learning algorithms was performed on clinical uEV samples collected from healthy controls, Diabetes Mellitus (DM) patients, and prostate cancer (PCa) patients. The optimal classification model achieved an overall multiclass diagnostic accuracy of 91% for distinguishing healthy, DM, and PCa groups. This work establishes a proximity-confined catalytic biosensing strategy for multiplexed uEV analysis and demonstrates its potential for uEV-based liquid biopsy and proof-of-concept disease stratification.
Feng Lin, Wanglong Li, Xinhuang Hou, Wei Lin, Xiaoling Lai, Xiaoqi Zheng, et al. Proximity-confined DNA walking-nanozyme cascades for multiplexed urinary extracellular vesicle phenotyping and machine learning-assisted disease stratification.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.119109.
Feng Lin, Wanglong Li, Xinhuang Hou, Wei Lin, Xiaoling Lai, Xiaoqi Zheng, et al (2026). Proximity-confined DNA walking-nanozyme cascades for multiplexed urinary extracellular vesicle phenotyping and machine learning-assisted disease stratification.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.119109
Feng Lin, Wanglong Li, Xinhuang Hou, Wei Lin, Xiaoling Lai, Xiaoqi Zheng, et al. Proximity-confined DNA walking-nanozyme cascades for multiplexed urinary extracellular vesicle phenotyping and machine learning-assisted disease stratification.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.119109.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出