Clinics in Orthopedic Surgery骨科手术临床
Clinics in Orthopedic Surgery(英文缩写 CLIN ORTHOP SURG),ISSN 2005-291X,eISSN 2005-4408,中文译名:骨科手术临床 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.503 | Q3 |
| 2022 | 2.500 | Q2 |
| 2023 | 1.900 | Q2 |
| 2024 | 2.000 | Q2 |
| 2025 | 2.500 | Q2 |
Clinics in Orthopedic Surgery 最新收录文献
-
1. Comparison of Clinical Outcomes According to Preoperative Skin Preparation in Hip Arthroplasty for Hip Fracture: A 3-Arm Randomized Controlled Trial.
1. 髋部骨折髋关节置换术中根据术前皮肤准备方式比较临床结局:一项三臂随机对照试验PMID:日期:2026-07-15[中文摘要] 接受关节置换术的髋部骨折患者通常高龄且体弱,浅表手术部位感染(SSIs)可延迟患者活动并延长住院时间。术前皮肤消毒是一种低成本、普遍使用的干预措施。然而,临床实践存在差异,且来自择期关节置换术的证据可能无法完全推广至紧急髋部骨折手术。联合使用聚维酮碘(PVI)和葡萄糖酸氯己定(CHG)的序贯双消毒方案正日益被采用;然而,“刷洗”与“涂布”的最佳顺序仍不明确。我们比较了采用不同PVI和CHG顺序的3种皮肤准备方案的预防效果。在这项单中心、前瞻性、随机对照试验中,108例因髋部骨折接受髋关节置换术的患者根据机械“刷洗”和最终“涂布”步骤所用消毒剂被随机分配至3组:1组(PVI刷洗/PVI涂布)、2组(PVI刷洗/CHG涂布)和3组(CHG刷洗/PVI涂布)。主要结局为铺巾前即刻皮肤培养阳性率及病原体鉴定结果。次要结局为浅表SSI的发生率。含CHG组(2组和3组:各5.6%)的皮肤准备后培养阳性率显著低于仅使用PVI组(1组:27.8%;= 0.005)。3种方案的浅表SSI发生率差异有统计学意义(= 0.015)。浅表SSI发生率最高见于1组(30.6%),其次为2组(13.9%)。3组浅表SSI发生率最低(5.6%)。在调整混杂因素的多变量logistic回归中,1组与3组相比,SSI风险显著更高(调整比值比3.89;95% CI 1.22-12.37;= 0.021)。消毒剂应用顺序显著影响微生物学结局,含CHG方案显示出更低的皮肤准备后培养阳性率。先以CHG刷洗、再以PVI涂布的方案提供了最有效的细菌抑制。还观察到浅表SSI发生率的差异,这可能反映了微生物控制改善的影响。优化消毒剂给药顺序可能有助于改善这一高危人群的感染预防。
[英文摘要] Patients with hip fractures undergoing arthroplasty are typically old and frail, and superficial surgical site infections (SSIs) can delay mobilization and prolong hospitalization. Preoperative skin antisepsis is a low-cost, universally used intervention. However, clinical practice varies, and evidence from elective arthroplasty may not fully generalize to urgent hip fracture surgery. Sequential dual-antiseptic protocols combining povidone-iodine (PVI) and chlorhexidine gluconate (CHG) are increasingly adopted; however, the optimal order for "scrub" versus "paint" remains unclear. We compared the prophylactic efficacy of 3 skin preparation protocols using different sequences of PVI and CHG. In this single-center, prospective, randomized controlled trial, 108 patients undergoing hip arthroplasty for hip fracture were randomly allocated to 3 groups based on the antiseptic agents used for the mechanical "scrub" and final "paint" steps: group 1 (PVI scrub/PVI paint), group 2 (PVI scrub/CHG paint), and group 3 (CHG scrub/PVI paint). The primary outcome was the rate of positive skin culture results immediately before draping and pathogen identification results. The secondary outcome was the incidence of superficial SSI. Post-preparation culture positivity was significantly lower in the CHG-containing groups (group 2 and group 3: 5.6% each) than in the PVI-only group (group 1: 27.8%; = 0.005). The incidence of superficial SSI differed significantly among the 3 protocols ( = 0.015). The highest superficial SSI rate was observed in group 1 (30.6%), followed by group 2 (13.9%). Group 3 had the lowest superficial SSI rate (5.6%). In multivariable logistic regression adjusted for confounders, group 1 was associated with a significantly higher risk of SSI than group 3 (adjusted odds ratio, 3.89; 95% CI, 1.22-12.37; = 0.021). The sequence of antiseptic application significantly influenced microbiological outcomes, with CHG-containing protocols demonstrating lower post-preparation culture positivity. A protocol using a CHG scrub followed by PVI paint provided the most effective bacterial suppression. Differences in superficial SSI rates were also observed and may reflect the impact of improved microbiological control. Optimizing the order of antiseptic administration may contribute to improved infection prevention in this high-risk population.
-
2. Correction: Cortical Support in Unstable Intertrochanteric Fracture without Fixation of Posteromedial Fragment.
PMID:日期:2026-07-15[This corrects the article on p. 413 in vol. 18, PMID: 42226786.].
-
3. Lateral Snapping Elbow Caused by Entrapment of the Degenerative Annular Ligament: A Case Series.
3. 退行性环状韧带嵌顿导致的肘关节外侧弹响:病例系列研究PMID:日期:2026-07-15[中文摘要] 外侧弹响肘是一种罕见疾病,而由环状韧带关节内病变所致的病例尤为罕见。本研究旨在分析环状韧带嵌顿所致外侧弹响肘的病例,以阐明其发病机制与临床特征。我们回顾了2010年至2018年间在3家医疗机构因环状韧带嵌顿导致疼痛性外侧弹响肘而接受手术治疗的4例患者。患者包括2例男性和2例女性,平均年龄59岁(范围45-69岁)。术前评估包括体格检查、X线、磁共振成像(MRI)及Mayo肘关节功能评分(MEPS)。所有患者平均随访10.5个月(范围6-12个月)。术前均注意到肱骨外上髁处明显压痛及弹响。MRI一致显示桡侧腕短伸肌(ECRB)起点处高信号强度。4例患者均被诊断为弹响肘伴外侧上髁炎,因保守治疗无效而接受手术干预。术中观察到桡肱关节内退变、嵌顿的环状韧带在前臂旋前位肘关节屈曲时复位。所有患者均行退变、嵌顿环状韧带的部分切除术,并同时行ECRB清创术。平均MEPS由术前73.8改善至术后100。环状韧带的退变可导致其嵌顿于桡肱关节,引起弹响肘。手术部分切除环状韧带及ECRB清创可有效缓解症状并恢复功能。环状韧带嵌顿所致弹响肘可通过发生于旋前和屈曲过程中的弹响来识别,提示韧带复位。
[英文摘要] Lateral snapping elbow is a rare condition, and cases attributed to intra-articular lesions of the annular ligament are particularly rare. This study was performed to analyze cases of lateral snapping elbow due to annular ligament entrapment to clarify its pathogenesis and clinical characteristics. We reviewed 4 patients who underwent surgical treatment for painful lateral snapping elbow caused by annular ligament entrapment at 3 institutions from 2010 through 2018. The patients included 2 men and 2 women with a mean age of 59 years (range, 45-69 years). Preoperative evaluations included physical examination, x-rays, magnetic resonance imaging (MRI), and the Mayo Elbow Performance Score (MEPS). All patients were followed up for an average of 10.5 months (range, 6-12 months). Significant tenderness at the lateral epicondyle of the humerus and snapping were noted preoperatively. MRI consistently demonstrated high signal intensity at the origin of the extensor carpi radialis brevis (ECRB). All 4 patients were diagnosed with snapping elbow associated with lateral epicondylitis, for which surgical intervention was performed because of resistance to conservative treatment. Intraoperatively, the degenerative, entrapped annular ligament within the radiocapitellar joint was observed to reposition during elbow flexion in forearm pronation. Partial resection of the degenerative, entrapped annular ligament was performed, along with ECRB debridement in all patients. The mean MEPS improved from 73.8 preoperatively to 100 postoperatively. Degeneration of the annular ligament can lead to its entrapment in the radiocapitellar joint, resulting in snapping elbow. Surgical partial resection of the annular ligament and debridement of the ECRB effectively resolve symptoms and restore function. Snapping elbow caused by annular ligament entrapment may be distinguished by snapping that occurs during pronation and flexion, indicating ligament relocation.
-
4. Does an Extended Offset Stem Improve Hip Stability and Function in Elderly Patients with a Femoral Neck Fracture?
4. 延长偏距假体柄能否改善老年股骨颈骨折患者的髋关节稳定性和功能?PMID:日期:2026-07-15[中文摘要] 老年患者髋部骨折仍是重大临床挑战,最佳手术策略尚存争议。关于采用延长偏心距骨水泥柄行全髋关节置换术(THR)治疗老年股骨颈骨折(FNF)后外展肌力量恢复及功能结局的证据仍然有限。我们评估了老年FNF患者行THR的功能结局和外展肌力量,比较了延长内侧偏心距(MO)柄与标准MO柄。我们回顾性分析了120例采用延长MO Exeter 44 mm柄行THR的FNF患者(A组)和100例采用标准MO Exeter 37.5 mm柄行THR的FNF患者(B组)。纳入患者Koval分级为3级或以上、美国麻醉医师协会(ASA)分级为3级或以下、简易精神状态检查评分24分或以上。比较患侧髋关节术后MO与自体髋关节。使用肌力测力计(KINVENT technologies)测量外展肌力量。调查包括脱位、大腿疼痛和股骨大转子疼痛(GTP)在内的并发症。两组间ASA、体重指数、骨密度或假体位置均无显著差异。A组患侧髋关节平均MO为42.6 mm,B组为36.2 mm,A组较自体髋关节(37.8 mm)大约5 mm,B组较自体髋关节(30.4 mm)大约6 mm。A组患侧髋关节外展肌力量恢复至自体髋关节的约86%,B组为81%。未发生脱位或大腿疼痛。A组有5例患者出现轻度GTP,接受物理治疗。与B组相比,A组患侧与自体髋关节在平均MO、平均垂直偏心距和外展肌力量方面的差异更小(< 0.05)。对于接受THR的健康老年FNF患者,延长MO柄对外展肌力量恢复具有积极作用,可能有助于改善关节稳定性。
[英文摘要] Hip fractures in elderly patients remain a major clinical challenge, with optimal surgical strategies still debated. Evidence regarding abductor strength recovery and functional outcomes after total hip replacement (THR) using an extended offset cemented stem in elderly patients with femoral neck fracture (FNF) remains limited. We evaluated functional outcomes and abductor muscle strength of THR for FNF in elderly patients, comparing an extended medial offset (MO) stem and a standard MO stem. We retrospectively reviewed 120 patients undergoing THR with an extended MO Exeter 44-mm stem (group A) and 100 patients undergoing THR with a standard MO Exeter 37.5-mm stem (group B) for FNF. We enrolled patients with a Koval grade of 3 or higher, an American Society of Anesthesiologists (ASA) grade of 3 or lower, and a Mini-Mental State Examination score of 24 or higher. Postoperative MO of the affected hip was compared with the native hip. Abductor muscle strength was measured using a muscle dynamometer (KINVENT technologies). Complications including dislocation, thigh pain, and greater trochanteric pain (GTP) were investigated. No significant differences in ASA, body mass index, bone mineral density, or implant position were observed between the 2 groups. The mean MO of the affected hip was 42.6 mm in group A and 36.2 mm in group B, approximately 5 mm greater than the native hip in group A (37.8 mm) and 6 mm greater in group B (30.4 mm). Abductor muscle power of the affected hip recovered to approximately 86% of the native hip in group A and 81% in group B. No dislocations or thigh pain occurred. In group A, 5 patients had mild GTP treated with physical therapy. Group A demonstrated smaller differences between the affected and native hips in mean MO, mean vertical offset, and abductor muscle strength compared with group B ( < 0.05). For healthy elderly patients with FNF undergoing THR, the extended MO stem had a positive effect on the recovery of abductor muscle strength, potentially contributing to improved joint stability.
-
5. Optimizing Drill Guide Positioning for Foveal Targeting in Arthroscopic One-Bone Tunnel Triangular Fibrocartilage Complex Repair: A Radiographic and Magnetic Resonance Imaging-Based Study.
5. 关节镜下单骨隧道三角纤维软骨复合体修复术中优化钻针定位以实现中央凹靶向:一项基于X线和磁共振成像的研究PMID:日期:2026-07-15[中文摘要] 为确定在关节镜下单骨隧道经骨修复术中,钻头导向器在三角纤维软骨复合体(TFCC)关节盘上方的最佳位置,以准确瞄准TFCC的凹部止点,本研究采用放射学和磁共振成像(MRI)分析。回顾性分析了60例因Palmer 1B型凹部撕裂接受关节镜下单骨隧道TFCC修复术的患者。通过分析术后X线片,测量骨隧道的起点、相对于尺骨干的角度以及隧道长度。随后将这些参数用于在术前MRI扫描上设定钻头导向器尖端在TFCC关节盘上方的预期位置。骨隧道起点的平均位置为尺骨茎突尖端近端12.0 mm,平均隧道角度为37.0°,长度为10.0 mm。MRI分析定位钻头导向器尖端位于尺骨茎突内侧缘桡侧约4.0 mm处的TFCC关节盘上方。该位置对应于腕关节镜下乙状切迹中心至尺骨茎突中心连线的外侧三分之一处。这些放射学和解剖学参数为关节镜下单骨隧道修复术中TFCC钻头导向器的定位提供了指导。在腕关节镜下瞄准乙状切迹中心与尺骨茎突之间连线的外侧三分之一处,为优化骨隧道放置以瞄准TFCC凹部止点提供了实用的解剖标志。
[英文摘要] To determine optimal drill guide positioning over the articular disc of the triangular fibrocartilage complex (TFCC) for accurately targeting the foveal insertion of the TFCC during arthroscopic one-bone tunnel transosseous repair using radiographic and magnetic resonance imaging (MRI)-based analysis. A retrospective review was conducted on 60 patients who underwent arthroscopic one-bone tunnel TFCC repair for Palmer type 1B foveal tears. Postoperative radiographs were analyzed to measure the bone tunnel's starting point, angle relative to the ulnar shaft, and tunnel length. These parameters were then used to set the expected position of the drill guide tip over the articular disc of the TFCC on preoperative MRI scans. The mean starting point of the bone tunnel was 12.0 mm proximal to the ulnar styloid tip, with an average tunnel angle of 37.0° and length of 10.0 mm. MRI analysis localized the drill guide tip approximately 4.0 mm radial to the medial aspect of the ulnar styloid over the articular disc of the TFCC. This location corresponded to the lateral one-third of a line connecting the center of the sigmoid notch to the center of the ulnar styloid process under the radiocarpal arthroscopic view. These radiologic and anatomic parameters provide a guide for positioning the TFCC drill guide during arthroscopic one-bone tunnel repair. Targeting the lateral one-third of a line between the center of the sigmoid notch and ulnar styloid under the radiocarpal arthroscopic view offers a practical landmark to optimize bone tunnel placement for targeting the foveal insertion of the TFCC.
-
6. The Efficacy of a Double Wiring Technique in Cementless Hemiarthroplasty for Unstable Basicervical Intertrochanteric Fractures: A Propensity Score-Matched Analysis of Femoral Neck Fractures.
PMID:日期:2026-07-15Basicervical intertrochanteric (IT) fractures are a distinct subtype of proximal femoral fractures, characterized by marked rotational instability and a high risk of fixation failure. In elderly patients, primary arthroplasty may serve as a viable option. This study aimed to report the clinical outcomes of cementless hemiarthroplasty using a double wiring technique for unstable basicervical IT fractures in elderly patients and to compare them with those after cementless hemiarthroplasty for displaced femoral neck (FN) fractures. We retrospectively reviewed 45 patients aged 75 years and older who received cementless bipolar hemiarthroplasty using a double wiring technique for unstable basicervical IT fractures and were followed up for more than 1 year between January 2015 and December 2022. After propensity score matching (2 : 1), the control group comprised 90 patients who underwent cementless hemiarthroplasty for displaced FN fractures. All operations were performed via a short external rotator-preserving posterolateral approach. The perioperative results, postoperative complications, and 1-year mortality of the 2 groups were investigated and compared. The IT group exhibited significantly longer operation times ( = 0.031) and greater total blood transfusion volume ( = 0.027) than the FN group despite no significant differences in blood loss and transfusion rate. No significant differences were observed in postoperative medical and surgical complications. Wire breakage occurred in 7 patients, and of those, 5 showed proximal migration of the greater trochanter fragment. However, there was no subsequent functional impairment in these patients. At 1 year after the index surgery, there were no significant differences in walking ability and mortality rate between the 2 groups. Cementless hemiarthroplasty with a double wiring technique for unstable basicervical IT fractures demonstrated clinical outcomes and 1-year mortality equivalent to those of hemiarthroplasty for displaced FN fractures, suggesting it as a feasible and safe option in osteoporotic elderly patients with these fractures.
-
7. Electrodiagnostic and Clinical Outcomes after Supercharged Anterior Interosseous Nerve Transfer in Advanced Cubital Tunnel Syndrome.
7. 晚期肘管综合征中增压前骨间神经转移后的电诊断与临床结果PMID:日期:2026-06-09[中文摘要] 在晚期肘管综合征(CuTS)患者中,由于神经再生所需距离较长,常规手术疗效往往欠佳。超强端侧前骨间神经至尺神经运动神经转位(简称SETS转位)已被提出用于增强神经再支配并加速恢复。本研究旨在评估SETS转位在晚期CuTS患者中的电生理和临床结局,并确定功能恢复的时间进程。本前瞻性研究纳入11例严重非创伤性CuTS患者(改良McGowan分级IIB或III级),均接受尺神经减压、皮下前移及SETS转位。术前及术后3、6、12个月进行电生理检查,评估小指展肌(ADM)和第一骨间背侧肌的复合肌肉动作电位(CMAP)、尺神经和尺神经背侧皮支(DUC)的感觉神经动作电位(SNAP),以及新生运动单位动作电位(MUAP)的检测。术前及12个月时评估握力和钥匙捏力及臂、肩、手功能障碍(DASH)评分。与术前评估相比,ADM的CMAP波幅在12个月随访时显著改善(= 0.004)。术后8例患者观察到新生MUAP,均在6个月内出现。相比之下,在术前无SNAP而术后出现反应的患者中,大多数在术后12个月首次记录到SNAP(尺神经SNAP为6例中的5例,DUC SNAP为7例中的5例)。钥匙捏力和DASH评分显著改善(分别为= 0.014和= 0.003),而握力无显著变化(= 0.142)。SETS转位可能促进严重CuTS患者的早期神经再支配并改善手内在肌功能。系列电生理检查提示,SETS转位可能有助于术后前6个月内的运动功能恢复。
[英文摘要] In patients with advanced cubital tunnel syndrome (CuTS), conventional surgical outcomes are often suboptimal due to the long distance required for nerve regeneration. The supercharged end-to-side anterior interosseous nerve to ulnar motor nerve transfer (referred to as SETS transfer) has been proposed to enhance reinnervation and accelerate recovery. This study aimed to evaluate the electrodiagnostic and clinical outcomes of SETS transfer in patients with advanced CuTS and to determine the time course of functional recovery. This prospective study included 11 patients with severe, non-traumatic CuTS (modified McGowan grade IIB or III) who underwent ulnar nerve decompression, subcutaneous anterior transposition, and SETS transfer. Electrodiagnostic studies were performed preoperatively and at 3, 6, and 12 months postoperatively, assessing compound muscle action potentials (CMAPs) of the abductor digiti minimi (ADM) and first dorsal interosseous muscles, sensory nerve action potentials (SNAPs) of the ulnar and dorsal ulnar cutaneous (DUC) nerves, and detection of nascent motor unit action potentials (MUAPs). Grip and key-pinch strength and Disabilities of the Arm, Shoulder, and Hand (DASH) scores were assessed preoperatively and at 12 months. The CMAP amplitude of the ADM significantly improved at the 12-month follow-up compared to the preoperative assessment ( = 0.004). Postoperative nascent MUAPs were observed in 8 patients, all of which appeared within 6 months. In contrast, among patients with no preoperative SNAP who had a postoperative response, most recorded their first SNAP at 12 months after surgery (5 of 6 for ulnar SNAP and 5 of 7 for DUC SNAP). Key-pinch strength and DASH scores improved significantly ( = 0.014 and = 0.003, respectively), while grip strength showed no significant change ( = 0.142). SETS transfer may promote early reinnervation and improve intrinsic muscle function in patients with severe CuTS. Serial electrodiagnostic studies suggest that SETS transfer may contribute to motor recovery within the first 6 months postoperatively.
-
8. Early Structural Healing and 12-Month Clinical Outcomes of Atelocollagen Patch Augmentation for Achilles Tendon Repair: A Prospective Cohort Comparison.
8. 跟腱修复中去端肽胶原补片增强的早期结构性愈合及12个月临床结局:一项前瞻性队列比较研究PMID:日期:2026-05-15[中文摘要] 跟腱断裂(ATR)是一种常见损伤,尽管有多种手术技术,但实现最佳的生物学愈合仍是一项挑战。本研究旨在探讨去端肽胶原补片增强对跟腱断裂修复的影响。我们假设去端肽胶原补片增强在结构和临床结局方面优于标准修复组。在这项前瞻性队列比较中,17例患者接受去端肽胶原补片增强的跟腱修复,18例接受标准开放性跟腱断裂修复的患者作为对照组。对两组之间的结局进行了比较。术后1、3、6和12个月通过超声检查和临床指标评估结局,包括跟腱总断裂评分(ATRS)、疼痛视觉模拟量表(VAS)和等速肌力。超声评估侧重于修复肌腱的横截面积(CSA)和肌腱内形态。超声评估显示,去端肽胶原补片组在术后1个月和3个月时CSA比值显著更高(分别为= 0.026和= 0.043),但在6个月和12个月时该差异无统计学意义。补片组在3个月和6个月时的形态学评分也更高(分别为= 0.009和= 0.027)。临床结局,包括ATRS、VAS疼痛评分和等速肌力,在所有随访时间点两组间均无显著差异。两组均未观察到再断裂、感染或过敏反应等并发症。去端肽胶原补片增强在跟腱断裂修复后的肌腱愈合中提供了早期结构学益处;然而,这些益处在12个月随访期内并未转化为更优的临床功能结局。尚需进一步的大规模研究来证实该技术的长期临床疗效和安全性。
[英文摘要] Achilles tendon rupture (ATR) is a common injury, yet achieving optimal biological healing remains a challenge despite various surgical techniques. This study aimed to investigate the effect of atelocollagen patch augmentation on ATR repair. We hypothesized that atelocollagen patch augmentation would show superior structural and clinical outcomes compared with the standard repair group. In this prospective cohort comparison, 17 patients were enrolled to undergo Achilles tendon repair with atelocollagen patch augmentation, while 18 patients receiving standard open ATR repair served as the control group. A comparison of outcomes between the 2 groups was performed. Outcomes were assessed at 1, 3, 6, and 12 months postoperatively via ultrasonography and clinical measures, including the Achilles Tendon Total Rupture Score (ATRS), visual analog scale (VAS) for pain, and isokinetic muscle strength. Ultrasonographic evaluation focused on the cross-sectional area (CSA) and intratendinous morphology of the repaired tendon. Ultrasonographic evaluation revealed that the atelocollagen patch group had a significantly higher CSA ratio at 1 and 3 months postoperatively ( = 0.026 and = 0.043, respectively), though this difference was not significant at 6 and 12 months. Morphology scores were also higher in the patch group at 3 and 6 months ( = 0.009 and = 0.027, respectively). Clinical outcomes, including ATRS, VAS pain scores, and isokinetic muscle strength, showed no significant differences between groups at all follow-up points. No complications, such as rerupture, infection, or allergic reactions, were observed in either group. Atelocollagen patch augmentation provides early structural benefits in tendon healing after ATR repair; however, these benefits did not translate into superior clinical functional outcomes within the 12-month follow-up period. Further large-scale studies are warranted to confirm the long-term clinical efficacy and safety of this technique.
-
9. Proximal Tibial Resection Alone Leads to a Significant Increase in Flexion Gap Size in Tibia-First Robotic-Assisted Posterior-Stabilized Total Knee Arthroplasty.
PMID:日期:2026-05-15Alignment philosophies in total knee arthroplasty (TKA) have shifted from universal mechanical alignment to patient-specific strategies aiming to optimize soft-tissue balance and improve satisfaction. Robotic-assisted TKAs have enhanced preoperative planning and intraoperative assessments, but the effects of sequential bone cuts on joint gaps remain unclear. This study evaluates whether flexion and extension gaps change after the tibial resection in tibia-first (TF) robotic-assisted posterior-stabilized (PS) TKA. A prospective observational study included 82 knees (78 patients) undergoing robotic-assisted TKA with a TF workflow. Gap assessments were recorded pre- and post-proximal tibial bone resection, both after posterior cruciate ligament (PCL) excision, using the Velys robotic system software. Changes in medial and lateral flexion and extension gaps were analyzed as paired measurements and correlated with femoral component modifications. Removal of the proximal tibial bone cut in isolation led to significant changes in the measured gaps, disproportionately more for the flexion than extension space. Medial and lateral flexion gaps increased by a mean of 2.57 mm and 2.30 mm, respectively, compared to minor changes in mean extension gaps (0.26 mm medially and -0.31 mm laterally) ( < 0.001). These changes influenced component sizing and positioning, with femoral component upsizing or component flexion performed in 70% of cases to balance the flexion and extension gaps. Proximal tibial bone resection, independent of PCL excision, significantly affects flexion gap size in PS-TKA, often necessitating intraoperative adjustments to femoral component size and position. The TF approach allows surgeons a second chance to optimize ligament balance through femoral component positioning, to achieve their desired balance target. While the clinical benefits of this intraoperative flexibility are intuitive, further research is warranted to establish whether this improves patient clinical outcome and satisfaction.
-
10. Accuracy of the Schöttle Technique for Femoral Medial Patellofemoral Ligament Footprint Localization in Trochlear Dysplasia: A Fluoroscopic Case-Control Study on 3-Dimensional-Printed Femurs.
10. Schöttle技术在滑车发育不良中股骨内侧髌股韧带足印区定位的准确性:一项基于3D打印股骨的透视病例对照研究PMID:日期:2026-05-15[中文摘要] 本研究旨在利用三维打印骨模型和标准化透视成像,评估Schöttle技术在伴有及不伴有滑车发育不良的股骨上定位内侧髌股韧带(MPFL)股骨止点的准确性。研究假设滑车发育不良,尤其是其较严重的形式,会对该放射学方法的准确性产生负面影响。分析共纳入44个三维打印股骨模型,这些模型基于滑车发育不良患者(n=21)和滑车形态正常者(n=23)的计算机断层扫描图像生成。解剖学MPFL止点以鞍状沟确定,并用不透射线标记物标记。获取膝关节标准侧位透视图像,并依据标准放射学标准确定Schöttle点。测量Schöttle点与解剖止点之间的距离。偏差>5 mm和>7 mm被定义为临床不可接受。根据Dejour分型进行亚组分析。发育不良组Schöttle点与解剖止点之间的平均距离为4.4±2.0 mm,对照组为4.2±2.4 mm(=0.862)。在5 mm阈值(66.7% vs. 60.9%,=0.467)或7 mm阈值(85.7% vs. 82.6%,=0.553)下,临床可接受置入比例无显著差异。不同发育不良分级间的准确性也相似(=0.477)。在这项实验建模研究中,Schöttle技术在伴有和不伴有滑车发育不良的股骨上定位MPFL股骨止点时表现出相似的平均准确性。然而,无论滑车形态如何,约三分之一的病例中观察到大于5 mm的临床相关偏差。在获得体内验证之前,Schöttle技术可作为术中估计而非确定性目标。外科医生应保持谨慎,并考虑辅助方法以优化股骨隧道置入。
[英文摘要] The objective of this experimental study was to assess the accuracy of the Schöttle technique in localizing the femoral footprint of the medial patellofemoral ligament (MPFL) in femora with and without trochlear dysplasia, utilizing 3-dimensional (3D)-printed bone models and standardized fluoroscopic imaging. It was hypothesized that trochlear dysplasia, particularly in its more severe forms, would negatively influence the accuracy of this radiographic method. A total of forty-four 3D-printed femoral models, generated from computed tomography scans of patients with trochlear dysplasia (n = 21) and those with normal trochlear morphology (n = 23), were included in the analysis. The anatomic MPFL insertion was defined using the saddle sulcus and marked with a radiopaque reference. True lateral knee fluoroscopic images were obtained, and the Schöttle point was identified using standard radiographic criteria. The distance between the Schöttle point and the anatomic footprint was measured. Deviations > 5 mm and > 7 mm were defined as clinically unacceptable. Subgroup analysis was performed according to Dejour classification. The mean distance between the Schöttle point and the anatomic footprint was 4.4 ± 2.0 mm in the dysplasia group and 4.2 ± 2.4 mm in the control group ( = 0.862). The proportion of clinically acceptable placements did not differ significantly at the 5 mm (66.7% vs. 60.9%, = 0.467) or 7 mm (85.7% vs. 82.6%, = 0.553) thresholds. Accuracy was also similar across dysplasia grades ( = 0.477). In this experimental modeling study, the Schöttle technique demonstrated similar average accuracy in localizing the femoral MPFL footprint in femora with and without trochlear dysplasia. However, clinically relevant deviations greater than 5 mm were observed in approximately one-third of cases, regardless of trochlear morphology. The Schöttle technique may serve as an intraoperative estimate rather than a definitive target, pending in-vivo validation. Surgeons should be cautious and consider complementary methods to optimize femoral tunnel placement.