Journal of Neural Engineering神经工程杂志
Journal of Neural Engineering(英文缩写 J NEURAL ENG),ISSN 1741-2560,eISSN 1741-2552,中文译名:神经工程杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 5.043 | Q2 |
| 2022 | 4.000 | Q2 |
| 2023 | 3.700 | Q2 |
| 2024 | 3.800 | Q2 |
| 2025 | 4.000 | Q2 |
Journal of Neural Engineering 最新收录文献
-
1. A statistical mixture-of-experts framework for EMG artifact removal in EEG: empirical insights and a proof-of-concept application.
PMID:日期:2026-10-01Effective control of neural interfaces is limited by poor signal quality. While neural network-based electroencephalography (EEG) denoising methods for electromyogenic (EMG) artifacts have gained traction in recent years, existing models perform suboptimally in settings with high noise. Since neural interfaces rely almost universally on some form of signal processing, uncovering effective algorithmic insights into EEG denoising is crucial for future success.To address the shortcomings of current machine learning (ML)-based denoising algorithms, we present a single-channel signal filtration algorithm driven by a new mixture-of-experts (MoEs) framework. Our algorithm leverages three new statistical insights into the EEG-EMG denoising problem: (1) EMG artifacts can be partitioned into quantifiable types to aid downstream MoE classification, (2) local experts trained on narrower signal-to-noise ratio ranges can achieve performance increases through specialization, and (3) correlation-based objective functions, in conjunction with rescaling algorithms, can enable faster convergence in a neural network-based denoising context.We empirically demonstrate these three insights into EMG artifact removal and use our findings to create a new downstream MoE denoising algorithm consisting of convolutional and recurrent neural networks. We tested all results on a major benchmark dataset (EEGdenoiseNet) collected from 67 subjects. We found that our MoE denoising model achieved competitive overall performance with contemporary ML denoising algorithms and strong lower bound performance in high noise settings. We further validated the framework on the SEED EEG corpus, observing statistically significant downstream classification gains under high-noise contamination.These preliminary results highlight the promise of our MoE framework for enabling advances in EMG artifact removal in EEG, especially in high noise settings. Further experimentation will be necessary to assess our MoE framework on a wider range of test cases and explore its downstream potential to unlock more effective neural interfaces.
-
2. Influences of design aspects on recording functionality of cuff-type peripheral nerve interfaces.
2. 设计方面对袖套式周围神经接口记录功能的影响PMID:日期:2026-09-29High-quality recording of peripheral nerve signals is a critical requirement for implantable neural interfaces, yet the influence of contact configuration and electrical insulation on cuff electrode recording quality remains poorly understood.Using a physical nerve model, the transfer function (TF) of commercially available split-cylinder and spiral cuff electrodes was measured for systematically varied contact configurations, including contact size, spacing, and size ratio of cathode to anode, as well as degree of electrical insulation. To derive single-fiber and compound action potentials, the TF was convolved with modeled action currents, enabling direct comparison of recording quality across designs.Contact edge spacing was found to be more decisive than contact surface area for recording amplitude, regardless of contact segmentation. In quasi-tripolar configurations, common mode suppression additionally reduced sensitivity to geometric variations. Both the length of the longitudinal insulation and the integrity of the electrode seal were found to strongly influence recording amplitude, with complete removal of the seal reducing amplitude by approximately 50%, outweighing all geometric design parameters combined.These findings establish electrical insulation integrity as the primary design criterion for cuff electrode recording performance, shifting focus away from contact geometry alone, and provide a practical framework for the development of next-generation peripheral nerve interfaces.
-
3. Chronic subthreshold rTMS transiently disrupts learning but enhances memory and flexibility in healthy rats.
3. 慢性阈下rTMS会短暂干扰健康大鼠的学习,但能增强其记忆和灵活性PMID:日期:2026-09-25Repetitive transcranial magnetic stimulation (rTMS) is an emerging non-invasive neuromodulation technique with therapeutic potential for the treatment of cognitive disorders. However, its effects on fundamental learning and memory processes in the healthy brain remain poorly understood. We have previously shown that subthreshold rTMS delivered with a miniaturized coil modulates neuronal activities and evoked potentials, but whether these physiological effects translate into cognitive changes remains unknown. Here, we systematically characterize the effects of subthreshold rTMS on learning and memory in healthy rats.We examined both chronic and acute effects of high-frequency (10 Hz) subthreshold rTMS on spatial learning, memory, and cognitive flexibility in healthy rats performing the Barnes maze task. The stimulation was delivered to the prefrontal cortex using the miniaturized coil, whose focal design operates at subthreshold intensity.We found that chronic rTMS transiently disrupted early spatial learning during the acquisition phase but did not impair overall task performance. In contrast, rTMS was associated with enhanced cognitive flexibility during the first reversal-learning phase and strengthened spatial memory of prior target locations during acquisition and reversal probe trials. These effects were not detected in the exploratory second reversal phase, and no acute cognitive effects were detected under alternating rTMS and sham stimulation. Together, these findings suggest complex, phase-specific effects of subthreshold rTMS on rodent cognition: transiently hindering early learning while promoting memory retention and flexibility.This work highlights both the opportunities and challenges of rTMS for cognitive modulation and provides a translational framework for optimizing stimulation protocols in neuropsychiatric and neurodegenerative disorders.
-
4. Selective activation of nerve fiber subpopulations with intrafascicular stimulation.
4. 使用束内刺激选择性激活神经纤维亚群PMID:日期:2026-09-24Peripheral nerve stimulation (PNS) is most effective when specific nerve fiber subpopulations are activated, while minimizing off-target activation, which may cause undesirable side effects. This selectivity depends primarily on electrode design and charge delivery, but it remains unclear how selectivity depends on electrode location within a fascicle and whether intrafascicular field steering can shape recruitment of different nerve fibers. Our objective was to test the hypothesis that selective PNS could be achieved through electrode placement and intrafascicular electric field steering using longitudinal intrafascicular electrodes (LIFEs).LIFEs were implanted into the tibial fascicle of the sciatic nerve of 17 anesthetized adult rats. We tested whether electrodes positioned at different cross-sectional and longitudinal locations within the same fascicle, together with different electric field-steering approaches produced distinct activation patterns in the gastrocnemius lateralis muscle. Muscle responses were measured using high-density epimysial electromyography (HD-eEMG).Electrodes placed at different locations within the same fascicle activated distinct muscle regions, demonstrating intrafascicular selectivity. Bipolar stimulation recruited nerve fibers differently than monopolar stimulation, showing that electric field steering can further shape the selective recruitment. In both configurations, increasing the stimulation amplitude produced a graded increase in muscle activation. Furthermore, our findings demonstrated that HD-eEMG is an effective tool for evaluating intrafascicular selectivity.These findings suggest that improving on-target selectivity may support next-generation bioelectronic therapies with better outcomes and fewer side effects, potentially enabling more precise, organ-specific neuromodulation. Using multiple intrafascicular electrodes may provide two complementary strategies for enhancing selectivity: strategic intrafascicular placement to access different fiber subpopulations and bipolar configurations to steer recruitment beyond what a single electrode can achieve.
-
5. Axonal theta oscillations evoke bursting in target hippocampal subregions.
5. 轴突θ振荡在目标海马亚区引发爆发性放电PMID:日期:2026-09-24Local field potentials (LFPs) measured in the extracellular matrix of the brain are postulated to arise from the integration of synaptic ionic currents and spread by volume conduction. However, there is a lack of consensus on whether these spatiotemporal voltage gradients are just an epiphenomenon of spiking or if the LFPs play a functional role in information processing.To examine a potential functional role of LFPs in information processing, we developed a microfluidic device that allows neurons from the hippocampal formation to self-wire through microfluidic channels, effectively isolating the activity of single axons between subregions of the network.We recorded spontaneous theta-band activity (4-10 Hz) in these axons whose power spectra were independent of simultaneous spiking activity. The highest theta amplitudes above noise were seen intermittently in a sparse set of axons from the CA3 into the CA1. Source neurons for the axonal theta were identified through cross correlation. Functionally, sparse axonal theta phase and amplitude correlated with target subregional spiking and more strongly with burst length.These results suggest that theta voltage oscillations in axons may contribute to activation of slow voltage-gated calcium channels to drive stronger synaptic release of transmitter to coordinate hippocampal activity between subregions. We propose that theta oscillations are controlled by specific ion channels distinct from those that generate spikes, a multiplex coding mechanism for inter-regional communication with implications for routing, executive control, electroencephalogram, disease states, and artificial neural networks.
-
6. A hierarchical graph learning framework for VR-based motor imagery decoding driven by MVMD and feature optimization.
6. 一种由MVMD和特征优化驱动的、基于虚拟现实的运动想象解码分层图学习框架PMID:日期:2026-09-23While virtual reality (VR) combined with action observation (AO) provides enriched visual guidance for motor imagery (MI), the decoding stability of MI Brain-Computer Interface (BCI) remains a challenge due to the inherent non-stationarity and low signal-to-noise ratio of Electroencephalography (EEG) signals in dynamic environments. Enhancing decoding accuracy and understanding neural representations in VR-based AO+MI tasks remain important challenges in neural engineering. This study proposes a hierarchical graph learning framework tailored for VR-based MI decoding, leveraging multivariate variational mode decomposition (MVMD) to decouple complex EEG signals into rhythmic components for enhanced multi-domain feature analysis, hybrid feature selection for compact representation, and functional brain network modeling based on phase locking value. Each EEG trial is represented as a sparsified graph, and a hierarchical graph convolutional network is designed to capture multi-scale spatial dependencies and high-order interactions for classification. Experimental evaluations on a lab-acquired VR-MI dataset demonstrate that the proposed framework achieves competitive three-class decoding accuracy. This performance surpasses baseline models such as EEGNet, as observed under VR-based motor imagery conditions. In addition to enhanced decoding performance, the study enables neurophysiological interpretation by characterizing VR-induced modulations in brain network organization. VR-based AO+MI paradigm is found to enhance sensorimotor connectivity and promote large-scale network integration, indicating more coordinated neural dynamics during MI tasks. These findings suggest that the proposed framework effectively improves VR-based AO+MI decoding while providing interpretable insights into neural mechanisms, supporting its potential for advanced BCI applications.
-
7. The effect of different observation modalities in motor imagery: Immersive virtual reality produces stronger desynchronization than video and real-world presentations.
7. 运动想象中不同观察模态的影响:沉浸式虚拟现实比视频和真实世界呈现产生更强的去同步化PMID:日期:2026-09-23The combination of action observation and motor imagery (AO+MI) has emerged as a promising neurorehabilitation strategy to promote sensorimotor plasticity without real movement, making it particularly valuable for individuals whose motor capacity is limited or absent. Improving AO+MI protocols requires understanding whether different observation stimuli engage the sensorimotor system to varying degrees, as the quality of cortical activation during each training trial may directly influence cumulative neuroplastic outcomes. The present study aimed to determine how the observation modality influences the activation of the sensorimotor cortex during synchronous AO+MI. Here, we investigated the effects of three observation modalities: immersive virtual reality (iVR), two-dimensional video and real-world observation of a robotic agent, on sensorimotor cortical engagement, using Event-Related Desynchronization (ERD) as a neurophysiological marker. Electroencephalographic (EEG) signals were recorded from fifteen healthy participants across three sessions, one per modality, while they observed a humanoid robot performing arm elevation movements and simultaneously engaged in motor imagery of the same movements. ERD was computed for alpha and beta frequency bands over eight electrodes covering frontocentral, central, and centroparietal regions. Statistical analyses revealed significant modality-dependent differences in sensorimotor cortical engagement across multiple frequency bands, electrode locations, and movement types. Immersive virtual reality consistently elicited the strongest desynchronization, with robust effects in the beta band over frontocentral and right centroparietal regions, and in the alpha band over the right central motor cortex. These results demonstrate that the modality of action observation significantly shapes sensorimotor cortical engagement during AO+MI. Our findings also support the integration of immersive virtual reality as a neurophysiological grounded tool for optimizing AO+MI-based neurorehabilitation protocols and brain-computer interface applications.
-
8. Diff-ADN: A diffusion-guided artifact denoising network with deterministic residual refinement for EEG.
8. Diff-ADN:一种用于脑电图的扩散引导伪影去噪网络及确定性残差精炼PMID:日期:2026-09-22Physiological artifacts degrade electroencephalographic (EEG) recordings and can affect downstream brain-computer interface (BCI) analysis. This study develops a compact single-channel framework for ocular, muscular, cardiac, and mixed-artifact removal.
Approach: The Diffusion-Guided Artifact Denoising Network (Diff-ADN) employs a two-stage framework comprising severity-conditioned Stage-I reconstruction followed by diffusion-guided Stage-II residual refinement. During training, forward noising and velocity prediction supervise the Stage-II encoder, whereas inference requires only a single deterministic residual correction, without iterative reverse-diffusion sampling. The framework was evaluated under contamination levels ranging from -7 to +2 dB, using independently recorded artifact sources and motor-imagery decoding across four public EEG datasets.
Main results: Diff-ADN achieved mean Pearson correlations of 0.936, 0.839, 0.886, and 0.844 for EOG, EMG, ECG, and mixed EOG+EMG artifacts, respectively. When tested with independently recorded artifact sources, performance varied by artifact type: larger reductions were observed for EOG and EMG, while PTB and INCART ECG differed from the MIT-BIH reference by 0.026 and 0.014, respectively. Across the four motor-imagery datasets, ECG denoising recovered 4.88-5.59 percentage points (pp) in decoding accuracy compared with artifact-corrupted EEG. The largest recovery was 21.90 pp for PTB ECG artifacts on BCI IV-2a at -6 dB.
Significance: The proposed framework combines artifact-aware EEG reconstruction with efficient deterministic inference, processing 2-s segments in 12.52-17.08 ms on the tested CPU. Results across independent artifact sources and multiple motor-imagery datasets further show that improvements in waveform reconstruction do not necessarily translate into uniform recovery of BCI decoding accuracy.
-
9. Identifying shared and personalized brain functional connectivity subspace across neuropsychiatric disorders.
9. 识别跨神经精神疾病的共享与个性化脑功能连接子空间PMID:日期:2026-09-22Neuropsychiatric disorders exhibit complex functional connectivity (FC) alterations, yet disentangling transdiagnostic mechanisms from disorder-specific network perturbations remains challenging due to clinical heterogeneity and multisite data confounds.We aggregated large-scale resting-state fMRI data from 1923 patients with major depressive disorder (MDD), autism spectrum disorder (ASD), or attention-deficit/hyperactivity disorder (ADHD), and site-matched controls from the REST-meta-MDD, ABIDE, and ADHD-200 consortia. We applied the established common orthogonal basis extraction algorithm to decompose individual FC matrices into shared and personalized subspaces following site-level normalization.We validated that shared subspaces captured robust pathological signatures capable of distinguishing patients from independent healthy controls from the human connectome project. A hierarchical analysis of these shared subspaces revealed a transdiagnostic core defined by widespread default mode network decoupling alongside divergent subcortical connectivity patterns: hyper-connectivity in MDD but hypo-connectivity in ASD and ADHD. Despite these conserved commonalities, we demonstrated a functional dissociation in clinical utility: personalized subspaces exhibited significantly higher utility for precision characterization, achieving superior performance in predicting individual symptom severity and in discriminating between diagnostic groups (macro-1: 77.6%)- tasks where shared features lacked sufficient specificity.These findings provide evidence consistent with a hierarchical neurobiological architecture wherein shared subspaces map conserved vulnerabilities, while personalized subspaces capture the heterogeneity underlying diagnostic distinctions and individual symptom expression. This work supports the value of modeling personalized neural signatures to advance precision psychiatry.
-
10. Perceptual characteristics of scotomas modulate visual performance under simulated prosthetic vision.
10. 暗点的知觉特征在模拟假体视觉下调节视觉表现PMID:日期:2026-09-22Retinal prostheses aim to restore vision in patients blinded by photoreceptor degeneration, yet functional outcomes vary substantially across individuals. Scotomas-regions of reduced or absent visual sensitivity-are a defining feature of retinal degenerative diseases, but their perceptual status is often underappreciated in the design and evaluation of prosthetic vision. Here, we investigated how differences in scotoma perception influence perceptual visual task performance and perceptual representations.Psychophysical experiments were conducted using a virtual reality platform that simulated visual field deficits characteristic of retinal degeneration, including age-related macular degeneration. Two different scotoma conditions, perceptually filled-in (invisible) and solid black, were implemented in a head-mounted display environment developed in Unity 3D Game Engine. Participants performed visual tasks while behavioral measures, including accuracy, response time (RT), and eye-tracking metrics, were recorded and analyzed.Despite identical visual inputs, task performance showed statistically significant differences depending on the perceptual characteristics (i.e. background-matching vs black) of the simulated scotoma. Critically, the spatial-frequency performance cost on RT was abolished selectively under the black-scotoma-with-phosphene condition ((3) = 8.72,= 0.033), whereas it remained significant under all invisible scotoma conditions, indicating that a perceptually distinct scotoma background enhances the detectability of phosphene signals. These differences were reflected corroborated by systematic divergences in gaze trajectory length and terminal fixation location across conditions.Our findings suggest that variability in scotoma perception constitutes an important, yet underexplored, factor contributing to inter-individual differences in the effectiveness of retinal prosthetic stimulation. Accounting for perceptual properties of scotomas may provide a framework for optimizing stimulation strategies and improving functional outcomes of future retinal prostheses.