JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY心血管电生理学杂志
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY(英文缩写 J CARDIOVASC ELECTR),ISSN 1045-3873,eISSN 1540-8167,中文译名:心血管电生理学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.942 | Q3 |
| 2022 | 2.700 | Q3 |
| 2023 | 2.300 | Q2 |
| 2024 | 2.600 | Q2 |
| 2025 | 2.400 | Q2 |
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY 最新收录文献
-
2. Safety and Efficacy of Right- Versus Left-Sided Transvenous Lead Extraction.
PMID:日期:2026-09-19Transvenous lead extraction (TLE) is increasingly performed for malfunction or infection of cardiac implantable electronic devices. Because of anatomic differences, TLE for right-sided (RS) electrodes may differ in outcome. This study aimed to evaluate whether RS TLE differs in patient characteristics and outcomes compared to left-sided TLE. We retrospectively analyzed patients who underwent TLE at the University Hospital Zurich from 2013 until 2023 regarding clinical and radiological success and complications. A total of 556 patients underwent 568 TLE from January 2013 until December 2023. Patients with RS TLE procedures (n = 147, 25.9%) were older, more often PM-dependent, had longer lead dwell time, more leads with passive fixation and were more often extracted for infection. RS TLE procedures had a longer procedure duration (130 vs. 108 min, p = 0.002), more often needed a snare-bailout strategy (22% vs. 10%, p = 0.0.45), resulted in lower radiological success rates (88.4% vs. 93.8%, p = 0.045) and more major as well as minor complication rates. In our retrospective single-center analysis, RS TLE Procedures were more challenging concerning patient characteristics and resulted in lower TLE success as well as higher complication rates.
-
3. Sensor-Driven Pacemaker Tachycardia During Chest Physiotherapy: The Hidden Accelerometer Sensor Response in a Leadless Pacemaker in the VDD Mode.
PMID:日期:2026-09-15Leadless pacemakers (LPM) provide ventricular pacing, atrio-ventricular (AV) synchrony and rate response. In the VDD mode, the single-chamber LPM is capable of atrial sensing with additional accelerometer activity sensing rate response. An 85-year-old man with tachy-bradycardia received a Micra AV2 (Medtronic Inc). During chest physiotherapy, pulse rate increased to over 100 bpm during chest percussion when performed on the left side. This was due to VDD mode switching to VVIR pacing when the accelerometer sensor rate exceeded the atrial rate. Inactivation of mode switching prevented rate acceleration. Chest physiotherapy caused unexpected rate increase in LPM even in VDD mode.
-
4. Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States.
PMID:日期:2026-09-15Pulsed field ablation (PFA) is an emerging non-thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real-world US registry. This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter-defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Twenty-six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [n = 1] and vascular complications [n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre-existing valve disease. After a median follow-up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence-free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. PFA for VA appears feasible and acutely effective, with a low rate of procedure-related complications. While acute success was high, long-term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy-delivery strategies. Larger prospective studies are warranted.
-
5. Ablation of AV Nodal Reentrant Tachycardia in Octogenarians: Safety and Efficacy in a Large Comprehensive Single-Center Analysis.
PMID:日期:2026-09-13Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia and is generally considered benign, with excellent outcomes following catheter ablation. However, data on procedural safety and efficacy in very elderly patients (≥ 80 years), who often present with multiple comorbidities and increased procedural risk, remain limited. This study aimed to evaluate acute efficacy and complication rates of slow pathway ablation or modulation (SPA/SPM) in octogenarians treated at a high-volume electrophysiology center. We retrospectively analyzed all consecutive octogenarian patients undergoing first-time SPA/SPM for AVNRT between 2001 and 2024. The primary efficacy endpoint was non-inducibility of AVNRT at the end of the procedure. Safety endpoints included atrioventricular block (AVB), pericardial effusion, and vascular access complications. Clinical outcomes were compared with a large institutional cohort of 6,020 patients undergoing SPA/SPM across all age groups. A total of 106 octogenarian patients (mean age 83.6 years) were included. Acute procedural success was achieved in 104 patients (98.1%). Two procedures were terminated prematurely due to transient AV conduction disturbances. Post-procedural AVB occurred in two patients, requiring permanent pacemaker implantation in one case. Pericardial effusion requiring pericardiocentesis occurred in two patients. Four patients developed significant bleeding or vascular access complications, with one requiring surgical intervention. Mean hospital stay was 1.3 days. Compared with the overall cohort, complication rates were higher in octogenarians (AVB: 1.9% vs. 0.12%; pericardial effusion: 1.9% vs. 0.08%; bleeding: 3.8% vs. 0.37%), while procedural success remained similarly high. SPA/SPM for AVNRT in octogenarians is highly effective with excellent acute success rates comparable to younger populations. However, complication rates are increased compared with a large institutional cohort and previously reported data. These findings highlight the need for careful patient selection, thorough risk-benefit assessment, and tailored procedural strategies when considering catheter ablation in this growing and vulnerable patient population.
-
6. First United States Experience With Focal Pulsed-Field Ablation Using the FARAPOINT Catheter for Refractory Ventricular Tachycardia.
6. 美国首次应用FARAPOINT导管进行局灶性脉冲场消融治疗难治性室性心动过速的经验PMID:日期:2026-09-13Drug-refractory ventricular tachycardia (VT) after failed radiofrequency (RF) ablation remains a clinical challenge. Pulsed-field ablation (PFA) is expanding to ventricular applications, but United States experience with focal pulsed-field-only catheters in VT is sparse, and pulsed-field platforms are not equivalent across manufacturers. Here we describe the first United States experience of FARAPOINT focal PFA in patients with refractory VT. We retrospectively reviewed ten consecutive patients who underwent VT ablation with the FARAPOINT (Boston Scientific) focal PFA catheter at a single VA Health Care System between July 2025 and May 2026. All patients had drug-refractory sustained monomorphic VT. Median age was 77 years with a mix of ischemic and nonischemic cardiomyopathy. Six of ten had at least one prior failed catheter ablation. Acute non-inducibility was achieved in all nine patients who underwent formal post-ablation stimulation testing. No procedural complications occurred. Over a median follow-up of 95.5 days, sustained VT recurred in four of ten patients. No patient underwent repeat ablation, required mechanical circulatory support, or died. In this initial United States experience, FARAPOINT was safe and acutely effective in patients with ischemic cardiomyopathy within a high-risk cohort with refractory VT and prior failed ablations, including challenging substrates. Prospective multicenter studies are warranted to expand these observations.
-
7. Localization of Non-Pulmonary Vein Trigger of Atrial Fibrillation in Relation to Atrial Low Voltage Area.
PMID:日期:2026-09-13We previously reported that non-pulmonary vein (PV) triggers of atrial fibrillation (AF) often arise from low-voltage areas (LVAs) in the left atrium (LA). However, the specific spatial relationship between trigger sites and distribution of LVAs has not been fully elucidated. This study aimed to analyze the relationship on a site-specific basis. Out of 1428 patients with AF undergoing catheter ablation, 187 (13.1%) who tested positive for non-PV triggers were enrolled. The spatial relationship between each trigger site and left atrial LVAs was evaluated. The study population included 121 men (66%), 110 patients with non-paroxysmal AF (59%), and 93 undergoing re-do sessions (50%). Mean age, eGFR, BNP, BMI, LAD, and LVEF were 68 ± 11 years, 59.9 ± 18.5 mL/min/1.73m, 116.6 ± 281.4 pg/mL, 23.3 ± 3.6 kg/m, 41.7 ± 6.5 mm, and 59 ± 7.8%, respectively. Non-PV trigger sites could not be identified in 18 cases due to lack of reproducibility. In the remaining 169 cases, single non-PV triggers were identified in 140 cases (82.8%), while 29 cases (17.2%) exhibited multiple triggers. Of the 99 LA non-PV triggers evaluated, 61 (61.6%) originated within an LVA. Half of the remaining non-PV triggers from intact areas were from the vicinity of LVAs. Specifically, more than half of the posterior/septal/inferior triggers arose from LVAs, whereas all anterior/roof triggers originated from LVAs. Patients were categorized into six groups based on trigger location: thoracic vein (superior vena cava, coronary sinus, and patent left superior vena cava), right atrium (RA), septum, LA, multiple triggers, and unidentified triggers. At the 24-month follow-up, the atrial tachyarrhythmia-free rate was significantly lower in the unidentified and multiple trigger groups (p < 0.05). LA non-PV triggers are closely associated with LVAs, particularly in the LA roof and anterior walls, though this association is less consistent in the posterior, septal, and inferior walls. Voltage mapping patterns may facilitate localization and detection of non-PV trigger sites in the LA.
-
8. Deciphering an Unexpectedly Small Change in VA Interval With Parahisian Pacing.
PMID:日期:2026-09-13该文献暂无摘要。
-
9. Anatomical Determinants of the Left Atrial Electrograms: Wall Thickness and Myocardial Fat Infiltration.
PMID:日期:2026-09-13Electrogram peak-to-peak voltage depends on atrial wall structure and mapping configuration. We evaluated the relationship between computed tomography-derived atrial wall thickness, intramyocardial fat, myocardial muscle thickness, and electrogram voltage obtained with omnipolar, bipolar, and unipolar mapping. Consecutive patients undergoing left atrial mapping during atrial fibrillation or atypical atrial flutter ablation were retrospectively included. Pre-procedural contrast-enhanced CT was processed with ADAS 3D to quantify left atrial wall thickness and intramyocardial fat infiltration, from which myocardial muscle thickness was derived. High-density electroanatomical maps were spatially co-registered with CT. Associations between anatomical parameters and peak-to-peak voltage were assessed, stratifying by rhythm stability. Twenty patients were included. In stable rhythms, left atrial wall thickness correlated positively with voltage for all configurations, strongest for unipolar (β = 0.38) and omnipolar (β = 0.23) vs. bipolar mapping (β = 0.13) (BP-UP p < 0.0001; BP-OT p < 0.01). Intramyocardial fat showed the strongest inverse association with omnipolar (β = -0.39), compared with bipolar (β = -0.14) and unipolar (β = -0.01; p ≤ 0.02). After excluding fat, muscle thickness correlated positively with OT (β = 0.30) and UP (β = 0.30), exceeding BP (β = 0.14; p < 0.0001). In unstable rhythms, associations were attenuated but OT remained most responsive to fat (β = -0.20) and muscle thickness (β = 0.11) (both p < 0.01). Myocardial muscle thickness is the main determinant of local atrial voltage, while intramyocardial fat contributes to voltage attenuation. OT provides the most consistent assessment of atrial wall composition, particularly under rhythm instability.
-
10. The Pear Strategy for Two-Ring Pulmonary Vein Isolation: Antral and Sleeve Ablation Using a Balloon-in-Basket Pulsed Field Ablation Catheter.
10. 双环肺静脉隔离的Pear策略:使用篮中球囊脉冲场消融导管进行窦和套管消融PMID:日期:2026-09-06Pulsed field ablation (PFA) has emerged as a promising energy source for atrial fibrillation (AF) catheter ablation. This study aimed to describe the adoption and workflow optimization of a novel balloon-in-basket PFA catheter using a two rings balloon and pear strategy for pulmonary vein isolation (PVI), the pear workflow. Consecutive all-comer patients with AF underwent PFA using the balloon-in-basket PFA catheter under deep sedation. The pear workflow comprised a two-step PVI protocol: (1) four antral PFA applications guided by initial PV angiography to confirm PV occlusion and lesion overlap through rotational deployment, followed by (2) two distal, pear-shaped balloon applications targeting the PV sleeves. Three-dimensional electroanatomic mapping with impedance-based contact assessment was utilized. Procedural parameters, acute efficacy, and safety were analyzed. Fifty patients (62% paroxysmal AF, 42% female, mean age 68 ± 10 years) were enrolled. All PVs were successfully isolated. Median procedural and fluoroscopy times were 50 min (IQR 41-50) and 7.2 min (IQR 5.8-11.4), respectively, without significant change over the study course (50 vs. 47 min for patients 1-25 and 26-50, respectively, p = 0.26). Additional ablation was performed in four patients, and concomitant left atrial appendage closure was performed in three. No major or minor complications occurred. Transient phrenic nerve stunning was observed in two patients, resolving before procedure completion. The pear two-step strategy enables rapid, efficient, and safe PVI using a balloon-in-basket PFA catheter, which, despite its anatomically based design, offers procedural versatility through integrated mapping with a minimal learning curve.