JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE心血管磁共振杂志
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE(英文缩写 J CARDIOVASC MAGN R),ISSN 1097-6647,eISSN 1532-429X,中文译名:心血管磁共振杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 6.903 | Q1 |
| 2022 | 6.400 | Q1 |
| 2023 | 4.200 | Q1 |
| 2024 | 6.100 | Q1 |
| 2025 | 5.000 | Q1 |
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE 最新收录文献
-
1. Comparison of Deep Learning-Based Free Breathing with Conventional Breath Holding CMR for Quantifying Degenerative Mitral Regurgitation.
PMID:期刊:日期:2026-10-03Cardiovascular magnetic resonance (CMR) imaging acquisition frequently relies on breath-holding, which poses challenges in patients with certain underlying comorbidities. A new technique consisting of deep learning-based accelerated 2D steady-state free precession (SSFP) cine imaging (Sonic DL Cine, GE HealthCare) allows for 1 heart beat free-breathing SSFP acquisition. This study aimed to demonstrate the accuracy of free-breathing acquisition SSFP using Sonic DL Cine and free-breathing phase contrast imaging versus standard breath holding for mitral regurgitation (MR) quantification in patients with degenerative MR. Patients with degenerative MR were prospectively enrolled and underwent both breath-holding and free-breathing CMR. Short axis SSFP images and phase contrast images in the ascending aorta and proximal pulmonary artery were acquired using breath hold and free-breathing techniques to quantify ventricular volumes and blood flow in the ascending aorta and proximal pulmonary artery. MR volume and fraction were calculated for each patient using both techniques. Pearson's correlation and Bland-Altman plots were utilized to compare the two groups. A total of 27 patients (64 ± 9 years; 67% male) underwent 33 CMR studies. There was no statistically significant difference in left ventricular end-diastolic volume (LVEDV), LV stroke volume (SV), aortic phase contrast, pulmonary artery phase contrast, MR volume or MR fraction between breath-holding and free-breathing CMR. Pearson's correlation and Bland-Altman plots demonstrated excellent correlation and good agreement for LVEDV (r = 0.96; mean difference 0.7mL; p<0.001), LVESV (r = 0.93; mean difference 2mL; p<0.001), LVSV (r = 0.96; mean difference -1 mL; p<0.001), MR volume (r = 0.96; mean difference -1mL; p<0.001), and MR fraction (r = 0.93; mean difference -0.4mL; p<0.001). Compared to conventional breath-holding, free-breathing CMR is feasible and comparable in the evaluation of ventricular parameters and MR quantification in patients with degenerative MR. This CMR technique would allow clinicians to accurately quantify MR in patients who are unable to perform conventional breath hold CMR.
-
3. Feasibility of Continuous Ventricular Volumetric Quantification in Arrhythmias using Real-Time 3D CMR-MOTUS.
PMID:期刊:日期:2026-09-26Conventional cardiovascular magnetic resonance (CMR) cine sequences rely on binning reconstructions that average multiple heartbeats, an assumption that breaks down in arrhythmic patients where beat-to-beat variations lead to motion artifacts and loss of clinically relevant functional information. While two-dimensional (2D) real-time imaging can capture individual heartbeats, a stack of 2D slices is sub-optimal to map the full complexity of incoherent cardiac dynamics during arrhythmia. We investigated the feasibility of three-dimensional (3D) real-time motion field reconstruction for continuous beat-to-beat volumetric quantification in patients with premature ventricular contractions (PVC) using a free-running CMR protocol. We extended CMR-MOTUS to jointly reconstruct real-time 3D motion fields and a motion-corrected reference image from continuously acquired data without breath-holds or electrocardiogram (ECG) gating. A variable-density Cartesian sampling trajectory (OPRA) was used with a 3D spoiled gradient echo or balanced steady-state free precession sequence. The real-time volumetric beat-to-beat changes were quantified by propagating a single manual segmentation on the reference image, through all time frames using the reconstructed motion fields. The method was evaluated on a cardiac motion phantom with ground-truth static acquisitions and in 10 healthy volunteers and 10 patients with PVC. All in vivo datasets were acquired post contrast enhancement. The ejection fraction (EF) was compared to ground-truth values for the phantom and to standard 2D real-time cine EF measurement techniques for the in vivo subjects. Reconstructed mean EF values of the phantom experiment were close to the ground-truth (Mean EF = 17.86 ± 0.33% versus 17.27%). In healthy volunteers, narrow beat-to-beat EF distributions reflected normal physiological consistency. In PVC patients, the method revealed broader, sometimes bimodal EF distributions. Simultaneously acquired ECG signals supported the temporal correspondence between volume irregularities and PVC episodes. 3D real-time joint motion field and image reconstruction from a free-running CMR protocol enables continuous beat-to-beat volumetric quantification in arrhythmic patients, revealing functional heterogeneity that conventional single-beat and averaging measurements (binning and gating) can obscure. Larger studies are needed before claims of clinical validation or replacement of standard 2D cine analysis.
-
4. Growth of Cardiac Fibromas During Infancy.
PMID:期刊:日期:2026-09-24Cardiac fibromas commonly present in childhood as large intramyocardial tumors that are frequently associated with arrhythmias, hemodynamic compromise, sudden cardiac death, and/or associated cardiac or lung compression. Although unoperated cardiac fibromas were historically thought to remain stable in size throughout life, their natural history has not been studied. In this retrospective single-center study, we identified all patients with cardiac fibromas and serial cardiovascular magnetic resonance (CMR) and/or cardiac computed tomography (CT) before or after surgical intervention to characterize fibroma growth. A total of 36 infants and children with at least 2 serial imaging studies were identified. Younger age at first imaging study was associated with faster cardiac fibroma growth, with infants (<12 months) demonstrating a body surface area (BSA)-indexed growth rate of 11 ± 2mL/m/month; whereas children older than 2.5 years demonstrated no growth (p=0.005). In one child, the tumor's unadjusted volume increased by 933% and the BSA-adjusted volume increased by 334% between CMR examinations obtained in the first week of life and at age 1.5 years. A higher T2 tumor:myocardium intensity ratio was associated with both younger age at initial examination and faster growth rate (p=0.001). A higher tumor growth rate was associated with the development of hemodynamic impact of the tumor, in particular pulmonary vein compression and/or lung compression. No significant tumor growth was observed after tumor resection. Cardiac fibromas may exhibit rapid growth in infancy, and tumor growth is associated with the development of hemodynamic compromise. Based on this observation, consideration should be given to frequent monitoring of tumor size and clinical status during the first years of life.
-
5. CPU-based fast cardiac cine MRI segmentation using lightweight CNNs and knowledge distillation.
PMID:期刊:日期:2026-09-07Cardiac cine MRI segmentation is essential for quantifying ventricular function, but current deep learning methods typically require GPU hardware for inference, limiting deployment in clinical settings with constrained computational resources. This study develops and evaluates lightweight CNN architectures trained via knowledge distillation for fast and accurate cardiac cine segmentation on CPU devices, including deployment in web browsers. A residual-encoder U-Net teacher (9.22M parameters) was distilled into three lightweight student networks - MobileUNetV2 (2.09M), MobileUNetV3 (4.52M, with squeeze-and-excitation attention), and EfficientLiteUNet (5.08M, fused mobile convolutions) - trained with deep supervision at four output scales. Distillation matched softened teacher and student probabilities via Kullback-Leibler divergence, with a grid search over temperature T ∈ {1.0, 3.0, 5.0} and KD loss weight W ∈ {0.5, 0.99}, giving 6 KD configurations per architecture. Models were trained on 560 image series from the combined ACDC and M&Ms datasets, evaluated on 280 held-out series, and on a 29-patient external cohort (UVA). Paired t-tests on per-case mean Dice with Holm-Bonferroni correction (m = 6) compared each KD configuration with its baseline. Inference was benchmarked on CPU using PyTorch, native ONNX Runtime (C++), and ONNX Runtime Web - the latter running entirely inside the user's web browser with no images sent to any server. The teacher reached a mean Dice of 0.894 across the three structures (LV cavity, LV myocardium, RV cavity). The best KD students reached 0.883 (MobileUNetV2), 0.883 (MobileUNetV3), and 0.888 (EfficientLiteUNet) at T=3.0, W=0.99, versus baselines of 0.871, 0.871, and 0.876. KD improved every architecture (Holm-adjusted p ≤ 5 × 10⁻⁷ at the best configuration), the top configurations forming a plateau rather than a unique optimum. Students tracked the teacher on the external cohort (0.903 versus 0.891 - 0.895) and on segmentation-derived ejection fraction in both cohorts, where no student's error differed from the teacher's (internal LV_EF bias -0.2 to +0.8%). On CPU, EfficientLiteUNet ran at 11 ms per frame natively (ONNX Runtime, 4 threads) while MobileUNetV2 was smallest (8.3 MB) and second-fastest in the browser (183 ms per frame), behind MobileUNetV3 (159 ms). Lightweight CNNs trained with knowledge distillation come within 0.006 - 0.011 Dice of the teacher and match its downstream clinical measurements, while running on CPUs and inside ordinary web browsers. The browser deployment performs every step locally on the user's device, so no patient images leave the local environment - a practical path to clinical use without GPU infrastructure or outbound transfer of imaging data. A reference instance is at https://cmrsegmentation.org and the code is at https://github.com/xf4j/cmrsegmentation. Cardiac MRI is the reference standard for measuring how well the heart pumps, but it requires a clinician or technologist to draw outlines around the heart's chambers and walls on dozens of images per scan - a slow and subjective task. Computers can do this automatically using artificial intelligence (AI), but most modern AI segmentation tools require expensive graphics hardware (GPUs) and often involve sending the patient's images to an external server, which raises both cost and data-privacy concerns. In this study we trained smaller, faster AI models that match the accuracy of a much larger reference model (within about one percentage point on standard accuracy benchmarks) while running on an ordinary computer's main processor in a fraction of a second per image - about a hundredth of a second natively, under a fifth of a second inside a web browser. We compared three different small-model designs and a grid of training settings, and found a range of settings that worked equally well across all three - useful guidance for other groups doing similar work. We then packaged the trained AI directly into a web page so that anyone with a modern web browser can drop in a cardiac MRI scan and see the segmentation result in seconds. Crucially, the web page does not send any images to a server; the AI runs entirely on the user's own computer, so patient data never leaves the local device. A live demonstration is available at https://cmrsegmentation.org and the source code is open-source. This makes accurate, automated cardiac MRI segmentation accessible to clinical sites that lack specialised hardware or that cannot share imaging data with external services.
-
6. Vasodilator stress perfusion CMR for outcome prediction in patients under 45 years with suspected CAD.
PMID:期刊:日期:2026-09-03Although the prognostic value of vasodilator stress cardiovascular magnetic resonance (CMR) is established, it has never been assessed in patients <45 years with suspected coronary artery disease. The aim was to assess the long-term prognostic value of stress CMR to predict mortality in a multicenter cohort of patients <45 years-old. Between December 2008 and December 2024, a prospective multicenter registry enrolled all consecutive patients undergoing vasodilator stress CMR at three French centers. For the present retrospective analysis, all patients aged <45 years were included. The primary endpoint was all-cause mortality, assessed through the French National Death Registry. Cox regression analyses were performed to determine the prognostic value of inducible ischemia and late gadolinium enhancement (LGE). Of the 3,671 patients (mean age 38±6 years, 65% males), 102 (2.8%) died after a median follow-up of 6.8 years (interquartile range: 3-11 years). Annualized mortality rates increased gradually with the number of segments of ischemia and LGE (both p-trend<0.001). The extent of ischemia (hazard ratio [HR]: 1.45; 95% confidence interval [CI]: 1.24-1.70) and LGE (HR: 1.56; 95% CI: 1.39-1.75) were both associated with mortality (both p<0.001). After adjustment for traditional prognostic factors, both the extent of ischemia (adjusted HR: 1.26, per 1-segment increase; 95% CI: 1.06-1.51, p=0.011) and LGE (adjusted HR: 1.50, per 1-segment increase; 95% CI: 1.25-1.80, p<0.001) remained independent predictors of mortality. In patients <45 years undergoing stress CMR, the extent of both inducible ischemia and LGE provide strong and independent prognostic value for predicting all-cause mortality.
-
7. Accelerated Cardiac MRI Using Deep Learning Cine Imaging: Validation in Pediatric Patients both with and without Congenital Heart Disease.
PMID:期刊:日期:2026-08-31Conventional breath-held 2D bSSFP cine CMR requires multiple breath holds and prolonged acquisition time, posing challenges for children and patients with congenital heart disease (CHD). Deep-learning (DL)-based reconstruction enables undersampled data acquisition with rapid image completion, offering the potential for substantial time savings while preserving diagnostic accuracy. Fifty pediatric patients (median age 16.1 years [14.7, 17.5], 56% CHD) with two-ventricle physiology were prospectively recruited, and underwent conventional breath-held bSSFP cine imaging and DL-accelerated cine imaging at three acceleration levels: with breath-held acquisitions over 3-RR intervals, 1-RR interval, and 1-RR interval with free-breathing. Acquisition time, image quality, and quantitative ventricular measurements were compared across sequences. Median short-axis cine stack acquisition time was reduced by 66%, 83%, and 89% for the 3-RR, 1-RR, and 1-RR free-breathing sequences, respectively, compared with conventional cine (all p<0.001). Image quality remained diagnostic in 96%, 88%, and 88% of cases, respectively with no statistical difference in image quality score between conventional cine and 3-RR acquisition. Quantitative assessment of myocardial thickening via radial strain demonstrated excellent agreement (ICC = 0.92, 95% CI 0.82-0.96, p < 0.001) between conventional cine and 3-RR acquisition, with only slightly higher measurements. on 3-RR sequences (29.7 ± 6.5% vs. 28.5 ± 6.1%, p<0.001). LV and RV volumes differed by <5 and <10mL/m² across all acceleration levels, LV mass by <3g/m², and LVEF/RVEF by ≤2%. Among CHD patients, a 2% overestimation of RVEF was observed. DL Cine enables rapid and diagnostically robust quantification of biventricular size and function in pediatric patients, including those with CHD. Image acceleration with 3-RR acquisitions optimally balances efficiency and image quality, supporting integration of DL cine imaging into routine pediatric and congenital CMR workflows.
-
8. Volumetric real-time MRI for the guidance of cardiac catheterization at 0.55T.
PMID:期刊:日期:2026-08-24Interventional cardiovascular MRI (iCMR) uses rapid high-contrast images to guide invasive procedures, such as right-heart catheterization (RHC), an important diagnostic tool for characterizing pulmonary hypertension and heart failure. Current iCMR uses interleaved multi-planar 2D acquisitions (1-3 planes) with balanced steady-state free precession (bSSFP) contrast. A common challenge is tracking devices as they move out of plane and the operational burden of updating views in real-time. We propose a volumetric method that images the heart and great vessels in their entirety, and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring. Volumetric real-time MRI (3DRT) was implemented at 0.55T using a stack-of-spirals bSSFP acquisition paired with a low-latency online spatiotemporally constrained image reconstruction, to achieve 3.5 mm isotropic spatial resolution and ~500 ms/volume temporal resolution. Numerical simulations were performed to evaluate tracking capability of gadolinium balloons as a function of device speed, and to verify image quality. Six healthy volunteers were imaged without catheterization to test performance on human subjects. Six naïve pigs were imaged during RHC, with gadolinium-filled polymer balloon wedge end-hole catheters. Simulation experiments demonstrated that 3DRT imaging with low-latency spatiotemporally constrained reconstruction can resolve moving catheters at ~2.0cm/s. 3DRT with bSSFP contrast was successfully demonstrated for right-heart catheterization procedures in porcine models, providing adequate blood-myocardium contrast, and balloon-blood contrast to track the catheter tip. 3DRT images provided adequate image quality and resolved respiratory motion in healthy volunteers. Volumes were re-sliced live and re-sliced planes could be flexibly manipulated during the scan in real-time before the next volume was acquired. Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T. 3DRT imaging has been demonstrated in model pig experiments with ~500 ms temporal resolution and 3.5 mm isotropic spatial resolution, providing improved balloon tracking.
-
9. 4D flow cardiac magnetic resonance postprocessing in congenital heart disease: SCMR FLIICR workgroup recommendations.
PMID:期刊:日期:2026-08-18The large majority of patients with congenital heart disease (CHD) survive into adulthood in the modern era of surgical advancements. However, patients require life-long follow-up and non-invasive imaging is crucial for diagnostic and therapeutic purposes. Cardiovascular magnetic resonance (CMR) plays a major role in patients with CHD as it is a non-invasive and ionizing radiation free imaging tool which overcomes the technical limitations of echocardiography. 4D flow is an evolving technique for flow quantification allowing improved CMR exam quality and reduced scan time. However, comprehensive postprocessing of hemodynamics in CHD may be demanding. This document addresses the needs for an "ideal" post-processing software for 4D flow in patients with CHD. It provides information on general requirements, velocity encoding, offset and aliasing correction, visualization, segmentation and reconstruction as well as output data. This document aims to support stakeholders in the field to develop solutions for improved 4D flow post-processing and visualization in CHD patients and thus improve the accuracy and efficiency of patient care.
-
10. Assessment of Coronary Plaque Burden using Non-Contrast T1-weighted Cardiovascular MR: Comparison with Coronary CT Angiography.
10. 使用非对比T1加权心血管MR评估冠状动脉斑块负荷:与冠状动脉CT血管造影的比较PMID:期刊:日期:2026-08-17[中文摘要] 非对比增强T1加权心血管磁共振(CMR)通过利用高危斑块成分内信号强度升高来评估冠状动脉粥样硬化斑块。新型iT2prep-BOOST序列可提供冠状动脉管腔与血管壁的全心配准成像,有望促进斑块评估。然而,iT2prep-BOOST与冠状动脉计算机断层扫描血管造影(CCTA,斑块评估的无创标准)之间定量斑块指标的直接比较仍然有限。本研究旨在比较iT2prep-BOOST测量的冠状动脉斑块负荷和斑块信号强度与CCTA得出的斑块负荷和斑块衰减特征。在这项前瞻性观察性研究中,招募了经诊断性CCTA确诊的稳定性冠状动脉疾病患者,随后使用iT2prep-BOOST序列进行CMR检查。使用半自动化软件,在CCTA上量化每个病灶的总斑块、钙化斑块、非钙化斑块和低密度非钙化斑块(≤30 Hounsfield单位)的横截面积,以及斑块负荷指标(血管粥样硬化百分比)。在T1加权黑血iT2prep-BOOST CMR上分析相应的冠状动脉粥样硬化病灶,以评估横截面斑块面积、负荷以及斑块与心肌信号强度比(PMR)。共分析85例患者的188个病灶,并在iT2prep-BOOST与CCTA之间进行比较。iT2prep-BOOST得出的斑块负荷估计值与CCTA得出的总斑块负荷(r = 0.58)和非钙化斑块负荷(r = 0.54)呈中度相关。然而,两种模态之间的一致性有限。对于总斑块负荷,平均差异为-4%(95% CI:-7%至-2%),一致性界限范围为-38%至29%。对于非钙化斑块负荷,平均差异为3%(95% CI:0%至5%),一致性界限范围为-34%至39%。在单变量回归分析中,PMR与总斑块、非钙化斑块和低密度非钙化斑块面积增加以及CT衰减值降低相关。iT2prep-BOOST评估的冠状动脉斑块负荷与CCTA得出的斑块负荷呈中等相关且一致性有限,表明这两种模态在斑块负荷量化方面不能直接互换。尽管如此,观察到的PMR与不良CCTA斑块特征之间的关联支持T1加权CMR作为冠状动脉斑块表征的补充性无创工具的潜在作用。
[英文摘要] Non-contrast T1-weighted cardiovascular MR (CMR) enables assessment of coronary atherosclerotic plaques by exploiting elevated signal intensity within high-risk plaque components. The novel iT2prep-BOOST sequence provides co-registered coronary lumen and vessel wall whole-heart imaging, potentially facilitating plaque assessment. However, direct comparison of quantitative plaque measures between iT2prep-BOOST and coronary computed tomography angiography (CCTA), the non-invasive standard for plaque assessment, remains limited. This study aimed to compare coronary plaque burden and plaque signal intensity measured by iT2prep-BOOST with plaque burden and plaque attenuation characteristics derived from CCTA. In this prospective, observational study, patients with stable coronary artery disease confirmed by diagnostic CCTA were recruited and subsequently underwent CMR using the iT2prep-BOOST sequence. Using semi-automated software, per-lesion cross-sectional areas of total, calcified, non-calcified, and low-density non-calcified plaque (≤30 Hounsfield unit) together with measures of plaque burden (percentage vessel atheroma) were quantified on CCTA. The corresponding coronary atherosclerotic lesion was analysed on T1-weighted black-blood iT2prep-BOOST CMR to assess cross-sectional plaque area, burden, and plaque-to-myocardial signal intensity ratio (PMR). A total of 188 lesions in 85 patients were analysed and compared between iT2prep-BOOST and CCTA. Plaque burden estimates derived from iT2prep-BOOST demonstrated moderate correlation with CCTA-derived total plaque burden (r = 0.58) and non-calcified plaque burden (r = 0.54). However, agreement between modalities was limited. For total plaque burden, the mean difference was -4% (95% CI: -7% to -2%) with limits of agreement ranging from -38% to 29%. For non-calcified plaque burden, the mean difference was 3% (95% CI: 0% to 5%) with limits of agreement from -34% to 39%. In univariate regression analyses, PMR was associated with increasing total, non-calcified, and low-density non-calcified plaque areas and decreasing CT attenuation values. Coronary plaque burden assessed by iT2prep-BOOST demonstrated modest correlation and limited agreement with CCTA-derived plaque burden, indicating that the two modalities are not directly interchangeable for plaque burden quantification. Nevertheless, the observed associations between PMR and adverse CCTA plaque characteristics support the potential role of T1-weighted CMR as a complementary, non-invasive tool for coronary plaque characterization.