CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES加拿大放射科医师协会杂志
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES(英文缩写 CAN ASSOC RADIOL J),ISSN 0846-5371,eISSN 1488-2361,中文译名:加拿大放射科医师协会杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.186 | Q2 |
| 2022 | 3.100 | Q2 |
| 2023 | 2.900 | Q2 |
| 2024 | 3.700 | Q1 |
| 2025 | 4.000 | Q1 |
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES 最新收录文献
-
1. Intracranial Arteriopathy and Ischemic Brain Injury in Adults With Sickle Cell Disease.
PMID:期刊:日期:2026-09-24Cerebrovascular injury is a complication of sickle cell disease (SCD), but the spectrum of MRI/MRA abnormalities in adults remains incompletely characterized. We described imaging abnormalities in a consecutive adult SCD clinic cohort undergoing MRI/MRA and examined clinical risk factors and intracranial arteriopathy features associated with parenchymal abnormalities. We retrospectively studied 527 consecutive adults with confirmed SCD who underwent brain MRI/MRA as part of routine follow-up at a tertiary SCD clinic, not restricted to patients with a history of stroke or TIA. Parenchymal outcomes included cortical, lacunar, watershed, and large-vessel territorial infarcts, Fazekas score >1, and global cortical atrophy. For each ischemic or atrophy-related outcome, Model A examined associations with predefined clinical and laboratory factors. Model B added steno-occlusive arteriopathy (SOA) and dilative intracranial arteriopathy (DIA) to evaluate whether vascular imaging features were associated with parenchymal abnormalities beyond clinical factors alone. Mean age was 33.0 ± 12.6 years; 55.6% were female. Ischemic abnormalities included cortical infarcts (13.1%), lacunar infarcts (9.7%), watershed infarcts (5.3%), and large-vessel territorial infarcts (3.4%). SOA was present in 9.3% and was associated with Fazekas score >1, lacunar infarcts, and global cortical atrophy in multivariable models. In targeted analyses, SOA was also associated with watershed and large-vessel territorial infarcts. In a consecutive adult SCD cohort undergoing routine MRI/MRA, ischemic and atrophy-related abnormalities were frequent and heterogeneous overall. SOA, but not DIA, was associated with several parenchymal injury patterns, supporting the potential role of intracranial vascular imaging in refining cerebrovascular phenotyping in adults with SCD.
-
8. Outcomes of Single-View Asymmetries Recalled From Screening Mammography and Exploratory Analysis of AI Detection.
PMID:期刊:日期:2026-08-20To evaluate the diagnostic outcomes of single-view asymmetries (SVAs) recalled from screening mammography and to explore the association between artificial intelligence (AI) detection and malignancy. This REB-approved retrospective single-center study included women recalled for SVAs from screening mammography performed at The Ottawa Hospital between March 1, 2024 and March 31, 2025. SVAs were defined as asymmetries identified on a single mammographic projection. Screening performance metrics were obtained from the EPIC Mammography Quality Standards Act module, and imaging outcomes were reviewed in PACS. Primary outcomes included cancer detection rate (CDR), positive predictive value for recall (PPV1), and positive predictive value for biopsy (PPV3). Following implementation of AI software (Transpara) in September/October 2024, exploratory analyses evaluated associations between AI flag status and malignancy. Among 32 412 screening examinations, 2455 patients (7.6%) were recalled, including 410 patients with 464 SVAs. Five cancers were identified, corresponding to a CDR of 0.16 per 1000 screened patients, significantly lower than the overall screening CDR of 6.08 per 1000 ( < .0001). PPV1 for SVAs was 1.22% (5/410), significantly lower than the overall PPV1 of 8.02% (197/2455) ( < .0001). Twenty-five patients (5.4%) underwent biopsy, yielding a PPV3 of 20%. Overall, 98.8% of recalled SVAs were non-malignant. Following AI implementation, malignancy rates were 0.6% (1/154) among non-flagged SVAs and 2.9% (2/68) among AI-flagged SVAs ( = .17). All malignancies were Stage I at diagnosis. SVAs were a common but very low-yield cause of recall in screening mammography. Although exploratory, the low malignancy yield among non-AI-flagged SVAs suggests a potential role for AI as a supportive adjunct in risk stratification and recall decision-making.
-
9. Effect of Deep Learning Training Policy on Greenhouse Gas Emissions and Carbon Efficiency for Chest Radiograph Classification.
PMID:期刊:日期:2026-08-12Environmental sustainability is an emerging priority in radiology, yet the impact of deep learning training policies on greenhouse gas emissions remains poorly characterized. This study quantified the effect of training policy on carbon dioxide equivalent (COeq) emissions and model performance for chest radiograph classification. Anteroposterior chest radiographs (128 907 training, 24 570 validation, 8282 test) were used to train 3 ImageNet-pretrained convolutional neural networks (ResNet-50, DenseNet-121, EfficientNet-B0) for 20 epochs. Three policies were evaluated: (1) retrospective optimal checkpoint selection at the validation loss minimum; (2) prospective early stopping (patience 10 epochs); and (3) fixed 20-epoch training without checkpoint selection. Per-epoch COeq emissions, energy, macro-averaged area under the curve (AUC), and carbon efficiency were evaluated. Validation loss reached its minimum at median epoch 2 for ResNet-50 and DenseNet-121 and epoch 4 for EfficientNet-B0. At the retrospective optimum, macro-AUCs ranged from 0.793 to 0.800 and generated 6.2 to 7.9 g COeq (37-46 Wh) at the deployed checkpoint. However, producing this model required the full run, generating 30.8 to 49.4 g COeq (181-291 Wh) with 78% to 84% of training emissions accruing after the deployed checkpoint. Prospective early stopping had macro-AUCs equivalent to the retrospective optimum (0.793-0.800), with 31% to 38% lower total emissions (21.1-30.9 vs 30.8-49.4 g COeq) and 57% to 76% higher carbon efficiency (25.9-37.6 vs 14.7-24.0 AUC/kg COeq) compared to fixed-epoch training. Up to 84% of total training emissions accrued after the optimal checkpoint, with relative savings dependent on the comparator. Prospective early stopping preserved performance, reduced emissions by up to 38%, and improved carbon efficiency by up to 76% versus fixed 20-epoch training.
-
10. Global Health in Radiology: Evolution, Challenges, and a Framework for the Future.
PMID:期刊:日期:2026-08-11Global health in radiology has expanded substantially over the past 2 decades. However, much of the field continues to be described through the language of outreach, volunteerism, and bilateral partnerships. While these concepts reflect an important part of how global radiology work has developed, they do not fully capture the wider systems issues that determine whether radiology services can function effectively over time. In practice, radiology services are shaped by workforce training, equipment procurement and maintenance, digital infrastructure, governance, financing, quality improvement, and evaluation. These factors influence whether imaging services are available, reliable, and able to support equitable care. This narrative review examines the development of global health radiology, distinguishes it from related concepts such as public health and international outreach, and synthesises the literature across major areas, including education partnerships, service development, teleradiology, point-of-care ultrasound, low-field magnetic resonance imaging, artificial intelligence, and interventional radiology capacity building. Particular challenges with radiology in global health settings include high equipment and infrastructure requirements, dependence on maintenance and technical support, and the need for sustained training, oversight, and long-term investment. The literature also demonstrates several ongoing limitations, including fragmented initiatives, limited evaluation frameworks, little attention to patient-centred outcome measurement, inequitable partnership models, and insufficient focus on implementation and financing. This review outlines future directions for global health radiology with relevance to equitable partnership design, sustainable funding, implementation, and alignment with broader health-system priorities.