OPTICAL ENGINEERING光学工程
OPTICAL ENGINEERING(英文缩写 OPT ENG),ISSN 0091-3286,eISSN 1560-2303,中文译名:光学工程 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.352 | Q4 |
| 2022 | 1.300 | Q4 |
| 2023 | 1.100 | Q4 |
| 2024 | 1.200 | Q4 |
| 2025 | 1.200 | Q4 |
OPTICAL ENGINEERING 最新收录文献
-
1. Mid-infrared spectroscopy on a fiber tip for molecular monitoring.
PMID:日期:2025-07-08Mid-infrared (mid-IR) fiber sensors offer highly specific and sensitive detection and analysis of various chemical species due to many molecular vibrations and fundamental absorption bands in this range. In this paper, we present a compact transflection-based mid-IR fiber probe, designed to be potentially suitable for sensing, with an optical pathlength that can be controlled during fabrication. The optical fiber probe was fabricated using a silver halide polycrystalline fiber positioned in front of a gold-coated short fiber to act as a mirror, and a connector to hold the two parts facing each other at a predetermined distance. The optical fiber probe was tested with a quantum cascade laser (QCL) in the mid-IR region. To investigate the impact of optical pathlength, the reflected signal was recorded at various distances between the cleaved fiber and the mirror in air and water. The influence of gold layer thickness was also examined to optimize the optical fiber probe's performance. To validate its sensing capability, the probe was employed to detect glucose solutions at physiological concentrations, achieving a detection limit of 8.91 mmol/L. The results highlight the potential of the proposed optical fiber probe sensor for molecular detection and analysis, offering a promising platform for monitoring for chemical and biomedical applications.
-
2. Sensitivity of radiometric results for a Lambertian source to simple changes of geometry.
PMID:日期:2025-02-02This work considers the effects of changes in distance, centering and tilting of optical elements on radiometric throughput. Analytical formulas for leading-order effects are compared to numerical calculations for validation purposes.
-
3. Acousto-optic-based time domain electric field sensor for magnetic resonance imaging applications.
PMID:日期:2024-01-20An acousto-optic (AO)-based electric field sensor is presented for time domain measurement under magnetic resonance imaging (MRI). A fully MR-compatible sensor is designed and fabricated using a phase-shifted fiber Bragg grating mechanically coupled to a piezoelectric transducer. Mechanical resonance of the piezoelectric transducer is matched to the operating frequencies of commonly used MRI systems to increase the sensitivity of the sensor. Sensitivity of the sensor is measured as 1.27 mV/V/m, with a minimum detectable electric field of 4.4 mV/m/√/Hz. Directivity of the sensor is measured with a 18 dB orthogonal component rejection. The dynamic range of the sensor is calculated as 117 dB/Hz, which allows the measurement of electric fields up to 3.2 kV/m. In MRI studies, the AO sensor was able detect local hot spots around a reference implant accurately with high signal-to-noise ratio. AO sensor exhibited similar or better performance when compared with commercially available MRI compatible electric field sensors. Furthermore, the small size of the sensor with the flexible fiber optic link could allow measurements of electric fields during critical interventional procedures such as pacemaker lead or deep brain stimulator placement as an MRI dosimeter during diagnostic scans.
-
4. Comparison of fiber-optic linear beam shaping designs for laparoscopic laser sealing of vascular tissues.
PMID:日期:2022-02-26Infrared lasers may provide faster and more precise sealing of blood vessels and with lower device jaw temperatures than ultrasonic and electrosurgical devices during surgery. Our study explores three beam shaping methods using optical fibers for transformation of a circular laser beam into a linear beam, necessary for integration into a standard 5-mm-diameter laparoscopic device, and for uniform irradiation perpendicular to the vessel length. In the first design, a servo motor connected to a side-firing, 550-m-core fiber, provided linear translation of a 2.0-mm-diameter circular beam, back, and forth, over either 5 or 11 mm scan lengths for sealing of small or large vessels. The second design used external beam splitters to divide laser power equally into three side-firing fibers, stacked side-by-side, producing a linear beam of 4 × 2 mm. The third design used external beam splitters with three forward-firing fibers and a slanted jaw surface, to produce a linear beam of 5 × 1.5 mm. Laser seals were performed, , on 41 porcine renal arteries of 1- to 6-mm diameter ( ≥ 10 samples for each design). Each vessel was compressed to a fixed 0.4-mm-thickness, matching the optical penetration depth at 1470 nm. Vessels were irradiated with fluences of 636 to 800 J/cm, which, based on previous studies, is sufficient for sealing, but not cutting. A burst pressure setup was used to evaluate vessel seal strength. Reciprocating fiber and fiber bundles produced mean burst pressures of 554 ± 142, 524 ± 132, 429 ± 99, and 390 ± 140 mmHg, respectively. All designs consistently sealed blood vessels, with burst pressures above hypertensive (180 mmHg) blood pressures. The reciprocating fiber produced the most uniform linear beam profile and aspect ratio but will require integration of the servo motor into a handpiece. Fiber bundle designs produced shorter, less uniform beams, but enable optical components to be assembled outside the handpiece.
-
5. Design, calibration, and application of a cryogenic low-background infrared radiometer for spectral irradiance and radiance measurements from 4 μm to 20 μm wavelength.
PMID:日期:2021We have constructed, calibrated, and tested a cryogenic low-background infrared radiometer for both spectral radiance and irradiance measurements over the 4 μm to 20 μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic infrared test chamber sources using a photoconductive Si:As Blocked Impurity Band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, while the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (< 1 mrad) infrared beams from 10 W/μm/cm to 10 W/μm/cm within the combined relative uncertainties of 2.6 % (coverage factor = 1.) We have also calibrated the radiometer for radiance measurements by using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer as well as its maintenance and stability are discussed.
-
6. Determining the thermomechanical image shift for the MIGHTI instrument on the NASA-ICON satellite.
PMID:日期:2020-01-11The Michelson Interferometer for Global High-Resolution Thermospheric Imaging (MIGHTI) instrument on NASA's Ionospheric Connection Explorer's mission will measure neutral winds in the Earth's thermosphere. We investigate how thermal changes to the instrument's optical bench affect the relative position of the image recorded by the camera. The thermal shift is measured by fitting the image of a series of reference notches and determining their current position on the camera with subpixel precision. Analyzing ground-based calibration data, we find that the image position is not affected within the uncertainty of the analysis for the applied thermal changes. We also address the question of the analysis uncertainty with signal-to-noise ratio.
-
7. Robust structured-light depth mapping via recursive decomposition of binary codes.
PMID:日期:2019-06-05Structured-light depth cameras rely on projecting and resolving coded patterns on a three-dimensional scene with high contrast. The front-end optics of such depth cameras impose a fundamental restriction on the depth-sensing range and accuracy: the patterns only remain sharp within the depth of field jointly determined by the camera and projector. We present here a robust method to improve the depth-sensing range and accuracy for a structured-light depth camera without changing the underlying optical design. Moreover, it shows the unique advantage in macrophotography of highly light-scattering objects. We analyze the proposed method theoretically and validate it in experiments.
-
8. Calibration lamp design, characterization, and implementation for the Michelson Interferometer for Global High-Resolution Thermospheric Imaging instrument on the Ionospheric Connection satellite.
PMID:日期:2019-05-31We describe the design and ground-based performance of the two-color calibration lamp for the Michelson Interferometer for Global High-Resolution Thermospheric Imaging (MIGHTI) instrument on the NASA Ionospheric Connection (ICON) satellite. The calibration lamp assembly contains radio frequency excited krypton and neon lamps, which generate emission lines at 557 and 630 nm, respectively, and which are used to monitor thermal drifts in the two MIGHTI Doppler asymmetric spatial heterodyne interferometers. The lamps are coupled to two mixed optical fiber bundles that deliver the calibration signals to the two MIGHTI optical units. The assembly starts reliably, consumes <8 W, and has passed environmental testing for the ICON satellite. The total mass of the lamp assembly is 1.8 kg. Special features of the assembly and its implementation are described along with results of life tests.
-
9. Evaluation of Lateral Resolution of Light Field Cameras.
PMID:日期:2018-09Light field cameras are an emerging imaging device for acquiring 3-D information of a scene by capturing a field of light rays traveling in space. As light field cameras become portable, hand-held, and affordable, their potential as a 3-D measurement instrument is growing in many applications, including 3-D evidence imaging in crime scene investigations. We evaluated the lateral resolution of commercially available light field cameras, which is one of the fundamental specifications of imaging instruments. For the evaluation of the camera's lateral resolution, we imaged Siemens stars under various imaging configurations and experimental conditions, including changes in distance between the camera and the resolution target plate, illumination, zoom level, location of the Siemens star in the camera's field-of-view, and cameras of the same model. The analysis results from a full factorial experiment showed that (i) when a lower zoom level of the camera was used, the lateral resolution tended not to be affected by distance; however, when a higher zoom level was used, it tended to decrease significantly with respect to the distance, (ii) the center region of the camera's field-of-view provided a better lateral resolution than the peripheral regions, (iii) a higher zoom level yielded a higher lateral resolution, (iv) the two cameras of the same model used in the study did not show a significant difference in the lateral resolution, and (v) changes in illumination did not affect the lateral resolution of the cameras.
-
10. In situ process monitoring in selective laser sintering using optical coherence tomography.
PMID:日期:2018-03-01Selective laser sintering (SLS) is an efficient process in additive manufacturing that enables rapid part production from computer-based designs. However, SLS is limited by its notable lack of in-situ process monitoring when compared to other manufacturing processes. We report the incorporation of optical coherence tomography into an SLS system in detail and demonstrate access to surface and sub-surface features. Video frame rate cross-sectional imaging reveals areas of sintering uniformity and areas of excessive heat error with high temporal resolution. We propose a set of image processing techniques for SLS process monitoring with OCT and report the limitations and obstacles for further OCT integration with SLS systems.