INVESTIGATIVE RADIOLOGY
INVESTIGATIVE RADIOLOGY(英文缩写 INVEST RADIOL),ISSN 0020-9996,eISSN 1536-0210 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 10.065 | Q1 |
| 2022 | 6.700 | Q1 |
| 2023 | 7.000 | Q1 |
| 2024 | 8.000 | Q1 |
| 2025 | 7.900 | Q1 |
INVESTIGATIVE RADIOLOGY 最新收录文献
-
2. Optimizing Brachial Plexus Diffusion Tensor Imaging: The Impact of Deep Learning Reconstruction and Simultaneous Multislice Acceleration on Single-shot Echo-planar Imaging.
2. 优化臂丛神经扩散张量成像:深度学习重建与同时多层加速对单次激发回波平面成像的影响PMID:日期:2026-11-01This study aimed (1) to quantify the differential impact of deep learning (DL) reconstruction on brachial plexus (BP) diffusion tensor imaging (DTI) image quality and quantitative metrics compared with conventional single-shot echo-planar imaging (EPI), (2) to clarify the clinical utility and limitations of integrating simultaneous multislice (SMS) acceleration with DL DTI in the challenging BP anatomy, and (3) to determine the optimal, time-efficient DTI protocol for robust BP tractography. Twenty-seven healthy volunteers were prospectively enrolled (stage 1: n = 14; stage 2: n = 13). All DTI acquisitions used a single-shot EPI sequence. In the first stage, DTI with DL reconstruction was compared with a conventional non-DL DTI. In the second stage, the integration of SMS acceleration into DL DTI protocols was assessed across 5 protocol sets. Fiber tract number, tract length, tract-based DTI metrics, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), image consistency, and interreader agreement were assessed in the BP postganglionic nerve roots and spinal cord. In the first stage, DL DTI demonstrated significantly higher tractography success rates, fiber numbers, and fiber lengths in the BP ( P < 0.05). DL substantially improved interreader agreement and image consistency, with the Dice similarity coefficient (DSC) increasing from 0.537 to 0.740 ( P = 0.006). DL reconstruction resulted in changes in anatomy-specific fractional anisotropy, with a significant decrease in BP fractional anisotropy but an increase in spinal cord fractional anisotropy. In the second stage, SMS-integrated protocols produced significantly lower tractography success and degraded image quality compared with non-SMS DL protocols ( P < 0.05). SMS integration resulted in lower SNR and CNR ( P < 0.05), and reduced image consistency (DSC decreased from 0.727 to 0.486, P = 0.015). The DL12-2 protocol (12 diffusion directions and two b800 acquisitions) was identified as the optimal time-efficient solution. DL reconstruction significantly improves the feasibility and reliability of BP DTI and affects quantitative metrics in an anatomy-specific manner. In contrast, the integration of SMS acceleration with single-shot EPI remains technically challenging in the high-susceptibility BP region. Our findings underscore that anatomy-specific optimization is essential for successful clinical integration of DL-enhanced DTI.
-
3. EPR-based Assessment of Gadolinium-based Contrast Agent Retention and Gadolinium Transchelation in Inflamed Murine Brain.
3. 基于EPR的钆基对比剂滞留及炎症小鼠脑内钆转螯合评估PMID:日期:2026-11-01In view of the mounting evidence for markedly increased cerebellar Gd retention under neuroinflammatory conditions after repeated linear GBCA administration in vivo , we aimed to discriminate between Gd retained within the GBCA complex and forms dissociated from the complex within the CNS and to characterize the chemical environment of the released Gd³⁺. For this purpose, we used electron paramagnetic resonance (EPR) spectroscopy, which enables direct detection of Gd³⁺ release and evaluation of its molecular surroundings in intact cerebellar tissue from inflamed and noninflamed brain sections exposed to either linear or macrocyclic GBCAs. We performed EPR and electron-nuclear double resonance (ENDOR) experiments on sub-mm brain samples taken after administration of linear gadopentetate-dimeglumine and macrocyclic gadobutrol in vivo in a murine multiple sclerosis model and ex vivo in organotypic hippocampal slice cultures under inflammatory conditions. Complementary mass spectrometry (MS) and MRI calibration experiments on Gd-spiked homogenized mouse brain tissue were used to identify potential Gd bindings and assess the relaxation-active fraction of retained Gd. EPR detected µM range Gd levels in intact cerebellar biopsies and slices and distinguished between complex-bound and released Gd following linear GBCA administration in vivo . In biopsies, we detected by ENDOR phosphorus-containing molecules in the microenvironment of released Gd. Binding to inorganic ligands was evidenced using MS and MRI calibration experiments in homogenized mouse brain tissue. EPR and ENDOR proved to be sensitive methods for detecting Gd³⁺ release and characterizing retained Gd species within intact brain tissue. Our findings demonstrate inflammation-promoted Gd retention, underscore the importance of integrating in vivo and ex vivo analyses to unravel mechanisms of long-term Gd retention, and suggest that conventional MRI may underestimate the true extent of Gd accumulation, especially under neuroinflammatory conditions.
-
4. It Is All About Energy-the Changing Role of X-ray Photons in Photon-counting Detector Computed Tomography: What the Radiologist Needs to Know About kV and keV.
PMID:日期:2026-11-01CT image quality is strongly influenced by the energy of the x-ray beam. The tube voltage (kV) determines a polyenergetic x-ray spectrum, which affects both image contrast and noise in conventional energy-integrating detector CT (EID-CT) imaging. In photon-counting detector CT (PCD-CT), spectral data sets are always available by default, and virtual monoenergetic images (VMI) can be reconstructed at any specific photon energy (keV). This enables radiologists to tailor energy selection to dedicated clinical tasks, achieving an optimal balance between contrast, noise, and radiation dose, and ultimately enhancing diagnostic confidence. This article educates the reader on the differences between polyenergetic and monoenergetic images to provide radiologists with practical insights into optimizing spectral imaging protocols and leveraging keV differences in routine clinical practice. Using an anthropomorphic phantom with iodine rods, differences in image quality, specifically image contrast and noise, are demonstrated between polyenergetic EID-CT and PCD-CT VMIs.
-
5. Photon-counting Detector CT Spectral Reconstructions for Radiomics-based Liver Lesion Classification: A Multicenter Study.
5. 光子计数探测器CT光谱重建用于基于放射组学的肝脏病变分类:一项多中心研究PMID:日期:2026-10-01Accurate noninvasive classification of hepatic lesions remains a diagnostic challenge, particularly on conventional CT. Photon Counting Detector CT (PCD-CT) offers spectral imaging capabilities that may enhance tissue characterization. This study aimed to evaluate the performance of radiomics-based machine learning for differentiating benign and malignant liver lesions using multispectral virtual monochromatic and material decomposition images derived from contrast-enhanced PCD-CT. This multicenter study included patients with focal hepatic lesions, scanned on PCD-CT at 2 separate institutions. Lesions were automatically segmented by a nnU-Net model and confirmed by an abdominal radiologist. Volumetric segmentations were used to extract radiomic features from 9 spectral datasets: 40, 50, 70, 90, 110, 140, and 180 keV, virtual non-contrast (VNC), and iodine density maps (IDM). A patient-based classification analysis was conducted by training multiple machine-learning models, with lesion-level predictions aggregated per patient. A Random Forest model further evaluated classification performancef across all train-test reconstruction combinations. The cohort comprised 378 patients (median age: 62; 59.5% female) from 2 centers, including 190 benign (n=227 lesions) and 188 with malignant (n=2681 lesions) hepatic findings. Random forest model trained on VNC achieved highest performance [AUC: 0.899; 95% CI (0.840-0.951); Accuracy 83.5%). In the cross-domain analysis, all training reconstructions achieved similar mean AUCs (0.75 to 0.83). Evaluation performance varied across test levels. Models tested on 110, 140, and 180 keV, and VNC showed the highest stability (median AUC ≥ 0.83), while 40 keV, 50 keV, and IDM resulted in lower and more variable AUCs (median AUC ≤ 0.71). Radiomics-based machine learning enables reliable differentiation between malignant and benign hepatic lesions on PCD-CT. The choice of test reconstruction influenced performance: higher energy levels and VNC images yielded more stable results. Incorporating high-energy reconstructions and VNC images into radiomic workflows for liver lesion risk stratification may enable noninvasive triage and reduce the need for invasive diagnostics.
-
6. Gadopiclenol for Cardiac MRI: Comparison of Myocardial T1 Relaxation Times and Subjective Image Quality at Different Doses in Patients With Anderson-Fabry Disease.
6. 加多匹仑醇用于心脏MRI:安德森-法布里病患者不同剂量下心肌T1弛豫时间与主观图像质量的比较PMID:日期:2026-09-25Due to its high relaxivity, the second-generation gadolinium-based contrast agent gadopiclenol has been shown to provide equally high image quality with reduced gadolinium dose. Gadopiclenol has not yet been approved for cardiac magnetic resonance imaging (CMR). The aim of this observational feasibility study was to assess late gadolinium enhancement (LGE) image quality and myocardial T1 shortening after application of gadopiclenol at 2 dose levels in patients with Anderson-Fabry disease (AFD) undergoing 3 T CMR. In this retrospective single-center study, 133 CMR examinations were screened, and 32 patients met the eligibility criteria of AFD, gadopiclenol administration, documented contrast dose, and complete precontrast and postcontrast T1 mapping. Patients were grouped by dose (0.05 mmol/kg group, ranging from 0.04 to 0.07 mmol/kg vs. 0.1 mmol/kg group, ranging from 0.08 to 0.11 mmol/kg; n=16 each). Three readers independently rated LGE image quality using a 5-point Likert scale. Quantitative analysis included precontrast and postcontrast myocardial T1, ΔT1, and the relaxation rate ΔR1. Segment-level postcontrast effects were analyzed using a mixed-effects model adjusting for acquisition delay. Both dose levels, the 0.05 mmol/kg and the 0.1 mmol/kg gadopiclenol, resulted in diagnostic examinations with high subjective LGE image quality. The 0.1 mmol/kg group showed slightly higher ratings for overall image quality and bloodpool-to-myocardium contrast, although absolute differences were small and most examinations in the 0.05 mmol/kg group were still rated good to excellent. Native myocardial T1 did not differ between groups (1132.39±61.91 ms vs. 1132.84±53.39 ms; P=0.98). Postcontrast T1 shortening was greater at 0.1 mmol/kg. In segment-level analysis, the higher dose showed greater ΔR1 in all segments, which was statistically significant in unaffected segments (Δ=-0.37 1/s; P=0.003), but not in affected segments (Δ=-0.18 1/s; P=0.48). In this retrospective 3 T AFD cohort, gadopiclenol provided high LGE image quality at both dose levels. While 0.1 mmol/kg produced slightly stronger qualitative and quantitative contrast effects, 0.05 mmol/kg remained technically feasible. These preliminary findings support that dose reduction to 0.05 mmol/kg gadopiclenol may be feasible in CMR. However, validation through prospective studies is needed before recommending lower-dose gadopiclenol broadly in routine CMR.
-
7. Gadolinium-based Contrast Agents Trigger Gadolinium Accumulation Within the Hippocampus In Vivo and Mitochondrial Alterations in Organotypic Hippocampal Tissue Cultures Ex Vivo.
PMID:日期:2026-09-21In multiple sclerosis (MS), mitochondrial dysfunction contributes to disease progression and may impair cognitive function, particularly in vulnerable regions such as the hippocampus. Gadolinium-based contrast agents (GBCAs) are widely used for imaging-based diagnosis of MS; however, evidence indicates that gadolinium (Gd) can be released from low-stability agents and retained in the brain. Whether retained Gd affects neuronal mitochondria, particularly under inflammatory conditions, remains unclear. We investigated hippocampal Gd retention following in vivo GBCA exposure and assessed associated mitochondrial effects in hippocampal slice cultures. Mice with experimental autoimmune encephalomyelitis (EAE) and healthy controls received repeated injections of linear gadopentetate-dimeglumine (gadopentetate) or macrocyclic gadobutrol (cumulative dose: 20 mmol/kg body weight). Hippocampal Gd distribution and retention kinetics were analyzed 1, 10, and 40 days post-final injection (p.f.i.) using laser ablation inductively coupled plasma-time-of-flight mass spectrometry (LA-ICP-ToF-MS). Ex vivo, organotypic hippocampal slice cultures from B6.Cg-Tg(Thy1-CFP/COX8A)S2Lich/J mice expressing fluorescently labeled neuronal mitochondria were exposed to TNF-alpha (paradigm of inflammation)±gadopentetate or gadobutrol for 48 hours (0.1, 1, 10, 50 mM). Mitochondrial dynamics were quantified using semi-automated and manual analyses of confocal microscopy images, and Gd slice content was determined by ICP-MS. In vivo, neuroinflammation increased hippocampal Gd accumulation following administration of both GBCAs in EAE mice. However, long-term retention up to 40 days p.f.i. was observed exclusively for gadopentetate, particularly in EAE mice. Ex vivo, prolonged exposure to both GBCAs at low-to-intermediate concentrations (0.1 to 10 mM) reduced mitochondrial length and area, particularly under inflammatory conditions, and altered mitochondrial motility relative to untreated controls. At these concentrations, intratissue Gd levels, quantified by ICP-MS under representative conditions, were within a biologically relevant, sub-cytotoxic range. Marked motility impairment and mitochondrial rounding occurred only at the highest gadopentetate concentration (50 mM). Interestingly, although inflammation did not alter Gd concentrations within the ex vivo slices, mitochondrial alterations were more pronounced under inflammatory conditions. In the hippocampus, long-term Gd retention in vivo appears to be restricted to linear GBCAs, whereas ex vivo, exposure to both linear and macrocyclic GBCAs at biologically relevant concentrations alters neuronal mitochondrial morphology and dynamics. Inflammation further amplifies these effects, highlighting the importance of considering GBCA-associated mitochondrial damage when evaluating their potential neurotoxic risks, particularly in neuroinflammatory diseases.
-
8. Influence of X-ray Tube Voltage on Computed Tomography Values and Contrast-Noise Ratios in Virtual Monoenergetic Images in routine clinical Photon Counting Detector Computed Tomography: Does kV Still Matter?
8. X射线管电压对常规临床光子计数探测器计算机断层扫描中虚拟单能图像计算机断层扫描值和对比噪声比的影响:kV还重要吗?PMID:日期:2026-09-15Conventional energy integrating detector (EID) CT provides polyenergetic images where CT values depend on the tube voltage (kV), hampering quantitative analysis across different CT scans. To mitigate this problem, spectral CT such as photon-counting detector (PCD) CT offers virtual monoenergetic images (VMI) where CT values depend only on the keV level but, ideally, not on the tube voltage. The purpose of this study was to investigate the kV dependence of VMI CT values in PCD-CT across a wide range of tissue types, keV levels, and kV settings for various phantom sizes, and to determine which kV settings yield the optimal contrast-to-noise ratio (CNR) for a given VMI energy and phantom size. The phantom study was complemented with an exploratory patient study. A spectral abdomen phantom (QSA-543; QRM) with 2 optional fat rings was scanned on a PCD-CT (NAEOTOM Alpha; Siemens Healthineers). The phantom contained rods with 2/5/10/15 mg/mL iodine (QRM); muscle/fat/liver equivalent tissue; and 400 mg/mL calcium (Gammex Sun Nuclear). A standard abdomen protocol was used at tube voltages of 70/90/120/140 kV. Polyenergetic images and VMIs (range: 40 to 100 keV in 5 keV increments) were reconstructed. For each VMI energy (keV), the percentage deviation ΔCT(%) of the mean CT value across the different kV settings was determined for each rod using region-of-interest (ROI) analysis. A ΔCT of 10% was considered the clinically acceptable upper limit. For each kV setting, the iodine CNR was calculated and normalized to the radiation dose (CTDIvol) to obtain CNRD. Higher CNRD indicated higher radiation dose efficiency. Edge spread functions (EFS) and noise power spectra (NPS) were evaluated for various kV settings. In the retrospective patient study, a standard cerebral CT angiography (CTA) protocol was applied at either 140 kV (n = 42) or 90 kV (n = 25), with VMI reconstructed at 55 keV. Both the ΔCT(%) and the CNRD relative to the ventricles were determined for various cerebral arteries. The 2 groups were compared using unpaired t tests. For all iodine and calcium rods and all phantom sizes, CT values remained stable within the predefined 10% tolerance across all kV settings in the VMI energy range of 40 to 70 keV, with ΔCT ≤8.4%. At 100 keV, ΔCT increased for low iodine concentration, reaching up to 36%, corresponding to a deviation of 19 HU from the mean CT value of 54 HU for 5 mg/mL iodine. Adipose tissue and liver exhibited ΔCT ≤10% at 45 to 70 keV. At 40 keV, deviations were larger but remained small in absolute terms (11.0 HU for liver and 19.6 HU for adipose tissue in the large phantom). For the small phantom and 40-60 keV, CNRD was 10% to 13% higher for 70/90 kV compared with 120/140 kV. EFS and NPS were consistent across kV settings. This advantage was lost at higher keV and larger phantoms. In patient VMIs at 55 keV, CNRD was 17% to 29% higher at 90 kV than at 140 kV, albeit generally not statistically significant. In VMIs acquired with PCD-CT, CT values were stable within the predefined 10% tolerance for all phantom sizes and tube voltages in the energy range of 45 to 70 keV, which is relevant for contrast-enhanced CT. This represents a significant step towards the meaningful comparison of CT values across different CT scans. At low keV and small phantom sizes, scans at 70 or 90 kV demonstrated greater radiation dose efficiency compared with scans at 120 or 140 kV. Therefore, for routine contrast-enhanced CT examinations of small patients or small body parts (eg, CTA of the head), scanning at low tube voltage may be considered if no spectral results other than VMIs are required.
-
9. The Challenge of Rendering Abnormalities Accurately Using Deep Learning-Based Reconstruction in Accelerated Brain MRI: A Disproportionate Loss of Clinically Relevant Image Information at Higher Rates of Acceleration.
9. 在加速脑部MRI中使用基于深度学习的重建技术准确呈现异常表现的挑战:加速倍率越高,临床相关图像信息的丢失越不成比例PMID:日期:2026-09-14Deep learning (DL)-based reconstruction methods can substantially accelerate MRI acquisition while preserving image quality relative to traditional techniques. However, concerns remain regarding their ability to accurately reconstruct abnormalities at higher acceleration factors. This study quantitatively assesses the impact of higher-order acceleration on image quality in DL-reconstructed brain MRI in normal and abnormal cases, emphasizing the utmost need to render abnormal findings accurately. Raw k-space image data from 5847 brain MRI examinations (fastMRI) were used. A radiologist-annotated subset of 1001 examinations (fastMRI+) served as the test set; the remainder were split into training (n=3715) and validation (n=1131) sets. Images were retrospectively undersampled (acceleration factors 2 to 12) and reconstructed using an end-to-end variational network. Image quality metrics, including normalized mean squared error (NMSE), structural similarity index measure (SSIM), and peak signal-to-noise ratio (PSNR), were computed within bounding-box annotations containing abnormalities and in size-matched normal control regions, and at the slice-level. The region-by-acceleration interaction was tested using linear mixed-effects models with a subject-level random intercept. All metrics demonstrated progressive degradation with increasing acceleration across slice-level and bounding-box-level analyses. At lower acceleration rates, bounding boxes with and without abnormalities showed comparable image quality. However, above 4-fold acceleration, NMSE within abnormal regions exhibited a notably sharper increase with rising acceleration compared to normal regions, while abnormal regions demonstrated a significantly faster decline in PSNR and SSIM. This nonsymmetric information loss was particularly evident for NMSE at higher acceleration rates. The region-by-acceleration interaction was statistically significant for all 3 metrics at both levels (all adjusted P<0.001), with the effect largest and most consistent for NMSE. Our findings demonstrate a disproportionate, pathology-localized degradation of reconstruction quality as acceleration increases. This emphasizes the importance of rigorous clinical assessment of image quality in DL-MRI reconstruction, particularly at higher undersampling rates, highlighting the need for reconstruction strategies tailored to maintaining diagnostically critical features.
-
10. Accelerated Body Composition Analysis in Whole-body MRI Using CycleGAN-based T2-HASTE Synthesis From Fast Whole-body Localizers.
10. 基于快速全身定位像的CycleGAN T2-HASTE合成在全身MRI中加速身体成分分析PMID:日期:2026-09-07To evaluate whether CycleGAN-based synthesis of T2-HASTE images from routinely acquired fast whole-body localizer (FWBL) can support accelerated body composition analysis (BCA) by preserving sufficient information for an established T2-HASTE-based BCA pipeline to generate measurements comparable to those derived from reference T2-HASTE images. This retrospective single-center proof-of-concept study included 468 patients (53% female, mean age 51±18 y) who underwent WB-MRI with FWBL and T2-HASTE between March 2012 and December 2025, 431 (92%) of whom were examined from 2023 onward. A CycleGAN model was trained to generate synthetic T2-HASTE images from registered FWBL and T2-HASTE images. Fully automated MRI-based BCA was conducted on synthetic and reference T2-HASTE images using a fixed pretrained BCA model, focusing on 5 key segmentation compartments: subcutaneous adipose tissue (SAT), muscle, abdominal cavity, thoracic cavity, and bone, with subsequent region-specific volumetric analyses of SAT, muscle, and bone in the thoracic, abdominal, and whole-body regions. Derived BCA markers included the Sarcopenia Index (muscle-to-bone ratio) and the muscle-to-SAT ratio. Agreement was assessed using Bland-Altman analysis, including mean bias expressed in absolute units and as a percentage of the mean reference volume, median absolute percentage error, Pearson correlation, and weighted Cohen kappa for tertile-based stratification. Segmentation overlap was evaluated using Sørensen-Dice similarity coefficients. In addition, a qualitative reader evaluation was performed by 4 radiologists across 30 cases. Mean percentage bias across the thoracic, abdominal, and whole-body regions was -0.05%, 3.51%, and 2.91% for muscle, -0.19%, -1.21%, and 0.71% for SAT, and -7.10%, -8.86%, and -6.30% for bone, respectively. Median absolute percentage error remained low for muscle (2.96% to 3.52%) and SAT (2.03% to 3.71%), whereas bone showed the highest relative error (5.93% to 8.26%). Tertile-based stratification agreement was high, particularly for the muscle-to-SAT ratio, with unchanged tertile assignment in 89.4% of thoracic, 93.6% of abdominal, and 95.7% of whole-body analyses (κ=0.92, 0.95, and 0.97, respectively). For the Sarcopenia Index, unchanged tertile assignment was 68.1%, 80.9%, and 87.2%, respectively (κ=0.76, 0.86, and 0.90). Segmentation overlap was high across the main compartments, with mean Sørensen-Dice coefficients of 0.90 for SAT, 0.87 for muscle, 0.94 for the abdominal cavity, and 0.91 for the thoracic cavity, whereas bone showed lower overlap (0.76). Qualitative evaluation showed positive ratings for both synthetic image utility and segmentation plausibility, with the synthetic T2 representation rated as providing added value over FWBL for coarse body composition assessment on a 5-point Likert scale, where 1 indicated strong disagreement, and 5 indicated strong agreement (mean: 4.52, median: 5). Combining FWBL MRI with CycleGAN-based image synthesis yielded BCA measurements that closely matched those from reference T2-HASTE images and largely preserved body composition stratification. These findings demonstrate the feasibility of deriving quantitative BCA information from routinely acquired WB-MRI localizer data and support further investigation of accelerated MRI-based BCA approaches using simplified acquisitions.