通过微流控易位事件计数进行超灵敏沙门氏菌检测的人工智能辅助微球免疫测定

Artificial intelligence-assisted microsphere immunoassay for ultrasensitive Salmonella detection through microfluidic translocation event counting.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

沙门氏菌对公共卫生构成重大威胁,因此需要快速、灵敏的检测策略以实现有效的食品安全监测。在此,我们提出一种人工智能辅助微球免疫分析(AIMI)方法,通过基于微球的微流控分析将病原体识别转化为超灵敏的事件水平定量读数。在该系统中,抗体包被的磁性纳米颗粒(MNPs)与聚苯乙烯微球(PS)同沙门氏菌形成三明治免疫复合物。这些复合物通过磁分离被选择性去除,留下未结合的残余PS微球,其数量与目标浓度呈负相关。当这些检测微球被引入微流控通道时,会产生流动调控信号,该信号可在事件水平上被解析,并通过微球数量和移位动力学进行表征。在AIMI中,脉冲低速传输是指在预设流速1.5 μL/min下短暂激活注射泵1秒所产生的瞬态微球运动。基于运动的校正进一步补偿了流动引起的位移变化,校正了运动相关的计数偏差,并提高了定量准确性。经位移信息校正后,检测线性度从0.983提高至0.99。该检测方法实现了10-10 CFU/mL的宽线性检测范围,检出限为2.51 CFU/mL。因此,该AIMI平台实现了单微球水平的精确移位事件计数,为沙门氏菌污染的超灵敏检测提供了有效策略。

Abstract

Salmonella pose significant threats to public health, necessitating rapid and sensitive detection strategies for effective food safety monitoring. Here, we present an artificial intelligence-assisted microsphere immunoassay (AIMI) that converts pathogen recognition into an ultrasensitive event level quantitative readout through microsphere-based microfluidic analysis. In this system, antibody-coated magnetic nanoparticles (MNPs) and polystyrene beads (PS) form sandwich immunocomplexes with Salmonella. These complexes are selectively depleted by magnetic separation, leaving residual unbound PS beads whose number inversely correlates with target concentration. When introduced into a microfluidic channel, these detection microspheres generate flow regulated signals that can be resolved at the event level and characterized by microsphere number and translocation dynamics. In AIMI, pulsed low-velocity transport refers to transient microsphere movement generated by briefly activating the syringe pump for 1 s under a preset flow rate of 1.5 μL min. Motion based correction further compensates for flow induced displacement variations, corrects motion related counting bias, and improves quantitative accuracy. With displacement informed correction, the linearity of detection improves from 0.983 to 0.99. The assay achieves a broad linear detection range of 10-10 CFU mL and a limit of detection of 2.51 CFU mL. As a result, this AIMI platform achieves accurate translocation event counting at the single microsphere level, providing an effective strategy for ultrasensitive detection of Salmonella contamination.

如何引用

AMA

Dingyang Xie, Xuewen Peng, Yiping Chen. Artificial intelligence-assisted microsphere immunoassay for ultrasensitive Salmonella detection through microfluidic translocation event counting.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.118944.

APA

Dingyang Xie, Xuewen Peng, Yiping Chen (2026). Artificial intelligence-assisted microsphere immunoassay for ultrasensitive Salmonella detection through microfluidic translocation event counting.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.118944

GB/T 7714

Dingyang Xie, Xuewen Peng, Yiping Chen. Artificial intelligence-assisted microsphere immunoassay for ultrasensitive Salmonella detection through microfluidic translocation event counting.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.118944.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biosensors & bioelectronics 的其他文献