Rhodanese实现了信号转换和纳米多孔金电传导,用于环境水中氰化物和亚硫酸盐的双重传感

Rhodanese-enabled signal conversion and nanoporous gold electrotransduction for dual sensing of cyanide and sulfite in environmental waters.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

氰化物和亚硫酸盐是环境中相关的污染物,由于其毒性、工业用途以及在受污染水体中可能共存,需要进行可靠的监测。然而,传统方法通常涉及繁琐的前处理、昂贵的仪器和基质干扰,限制了快速环境分析。在此,我们报道了一种硫氰酸酶偶联纳米多孔金(NPG)电化学平台,利用NPG修饰的玻碳电极(NPG/GCE)实现对氰化物和亚硫酸盐的双重检测。NPG界面能够实现灵敏的亚硫酸盐氧化,在+0.14 V处出现明显的氧化峰,而氰化物则通过Rdl2催化的氰化物与硫代硫酸盐之间的化学计量反应进行间接定量。该反应以1:1的比例生成硫氰酸盐和亚硫酸盐,选择生成的亚硫酸盐而非硫氰酸盐作为电活性报告分子。该信号转换策略将电活性较差的氰化物转化为易于检测的物质。该平台对直接亚硫酸盐检测的线性范围为0.1-2000 μM,基于生成的亚硫酸盐氧化信号对间接Rdl2辅助氰化物检测的线性范围为0.1-1000 μM,相应的检测限分别为50.44 nM和48.42 nM。该平台还表现出良好的操作稳定性和Rdl2储存稳定性、可接受的抗干扰性能,以及在实际环境水样中令人满意的加标回收结果,亚硫酸盐的回收率为97.63%-110.09%,氰化物的回收率为96.90%-108.20%。该系统将Rdl2的特异性与基于NPG的信号放大相结合,为电活性较差污染物的电化学监测提供了一种简单的酶信号转换策略。

Abstract

Cyanide and sulfite are environmentally relevant pollutants that require reliable monitoring because of their toxicity, industrial use, and potential co-occurrence in contaminated waters. However, conventional methods often involve laborious pretreatment, expensive instrumentation, and matrix interference, limiting rapid environmental analysis. Here, we report a rhodanese-coupled nanoporous gold (NPG) electrochemical platform for dual detection of cyanide and sulfite using an NPG-modified glassy carbon electrode (NPG/GCE). The NPG interface enabled sensitive sulfite oxidation with a distinct peak at +0.14 V, whereas cyanide was indirectly quantified through the Rdl2-catalyzed stoichiometric reaction between cyanide and thiosulfate. This reaction produces thiocyanate and sulfite in a 1:1 ratio, and the generated sulfite, rather than thiocyanate, was selected as the electroactive reporter. This signal-conversion strategy converted poorly electroactive cyanide into a readily detectable species. The platform showed a linear range of 0.1-2000 μM for direct sulfite detection and 0.1-1000 μM for indirect Rdl2-assisted cyanide detection based on the generated sulfite oxidation signal, with corresponding detection limits of 50.44 nM and 48.42 nM, respectively. It also exhibited good operational and Rdl2 storage stability, acceptable anti-interference performance, and satisfactory spike-recovery results in environmental water samples, with recoveries of 97.63%-110.09% for sulfite and 96.90%-108.20% for cyanide. This system integrates Rdl2 specificity with NPG-based signal amplification, offering a simple enzymatic signal-conversion strategy for electrochemical monitoring of poorly electroactive pollutants.

如何引用

AMA

Huiyuan Yu, Zihan Huang, Zhigang Chen, Jun Li, Min Kang, Yongzhen Xia, et al. Rhodanese-enabled signal conversion and nanoporous gold electrotransduction for dual sensing of cyanide and sulfite in environmental waters.. Biosensors & bioelectronics. 2026; doi:10.1016/j.bios.2026.118967.

APA

Huiyuan Yu, Zihan Huang, Zhigang Chen, Jun Li, Min Kang, Yongzhen Xia, et al (2026). Rhodanese-enabled signal conversion and nanoporous gold electrotransduction for dual sensing of cyanide and sulfite in environmental waters.. Biosensors & bioelectronics. https://doi.org/10.1016/j.bios.2026.118967

GB/T 7714

Huiyuan Yu, Zihan Huang, Zhigang Chen, Jun Li, Min Kang, Yongzhen Xia, et al. Rhodanese-enabled signal conversion and nanoporous gold electrotransduction for dual sensing of cyanide and sulfite in environmental waters.[J]. Biosensors & bioelectronics, 2026 doi:10.1016/j.bios.2026.118967.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biosensors & bioelectronics 的其他文献