MEDICAL PHYSICS 最新收录文献
-
1. Deep learning-based CNN method for fiducial marker detection in kilovoltage X-ray images for liver tumor motion monitoring.
PMID:DOI:日期:2026-10During radiation therapy, liver tumor motion can reduce dose delivery accuracy and increase irradiation of adjacent healthy tissues. Because liver tumors are difficult to visualize directly on kilovoltage (kV) X-ray images, fiducial markers are commonly implanted as surrogates for tumor position during treatment. Conventional marker-segmentation approaches such as template matching can lose accuracy when markers are obscured by bone, surgical clips, or stents. Although Convolutional Neural Network (CNN)-based approaches have shown strong performance for image analysis, their application has been constrained to more static organs such as the prostate or has used single-center and vendor-specific datasets, limiting assessment of model transportability across different institutions and anatomic sites. The aim of this study was to develop, integrate, and evaluate a CNN-based method for fiducial marker detection in kV X-ray images to support real-time image-guided radiation therapy (IGRT) during liver radiotherapy using a multi-institutional, multi-platform dataset spanning both large and fast free-breathing motion and slow and small breath-hold motion. A compact Convolutional Neural Network (CNN) was trained on 314,625 kilovoltage (kV) X-ray images encompassing 28 patients from the multi-institutional TROG 17.03 LARK clinical trial (NCT02984566). The model was validated using a hold-out set of 31,463 images (10%) from the same cohort of 12 patients and 55 treatment fractions, spanning three centers and three respiratory motion-management techniques. The CNN was tested on 4184 images from 16 patients and 55 fractions across three centers and three motion-management techniques. The ground truth for testing was manually segmented marker positions from every 10 degrees of gantry rotation for each fraction of each test patient. Based on AAPM guidelines (TG147 and TGB135.B), feasibility for clinical implementation was predefined as > 95% of marker positions being within 2 mm of the ground truth position in each dimension, and processing time less than 150 ms per image using a simulated real-time Kilovoltage Intrafraction Monitoring (KIM) framework. Additional evaluation metrics included sensitivity, specificity, and the area under the precision-recall curve (AUC). For the unseen test patient data, the marker position was segmented by the CNN within 2 mm in 95.4% of frames on the X axis and 97.6% of frames on the Y axis, meeting AAPM criteria. Sensitivity reached 97.76%, specificity was 99.94%, and the AUC was 0.9964. No statistically significant difference in localization error was observed between breath-hold and free-breathing treatments, although this comparison was limited by the small number of free-breathing patients. Localization error differed significantly between Varian and Elekta linacs due to imbalance within the dataset. The processing time for each image was 50-60 ms using a NVIDIA GeForce RTX 3070 GPU. A CNN-based method for fiducial marker detection in the liver was developed and evaluated on multi-institutional kV X-ray images spanning free-breathing and breath-hold motion, as well as Varian and Elekta linac platforms. The method satisfied the predefined feasibility criteria for positional accuracy and computation time, supporting future translation toward clinical implementation.
-
2. Direct spatial convolution for pencil beam dose calculation and feasibility of dij-free IMRT optimization on GPU.
PMID:DOI:日期:2026-10In pencil beam dose calculation, the convolution is usually performed in the frequency domain via FFT. The dose is assembled into a sparse dose-influence matrix (dij) for optimization. We propose to perform the convolution directly in the spatial domain with a deep-learning operator (Conv2d), and investigate the feasibility of a dij-free optimization. A 6 MV photon kernel (1 Gaussian penumbra and 3 singular value decomposition (SVD) scatter components, 0.5 mm resolution) was adopted. The Conv2d operator was validated against FFT on head-and-neck (HN), prostate and liver cases, with 7, 5, and 4 beams and corresponding 7503, 2649, and 845 bixels. The cost of building dij was investigated to identify the bottleneck. A one-layer network optimization framework was implemented to investigate the feasibility of the dij-free optimization (workflow A). Workflow A recomputes the dose with Conv2D at each iteration, with no pre-calculated dij. The traditional dij-based workflow (B) was implemented for comparison. Across all 16 beams Conv2d reproduced FFT at machine precision (maximum absolute dose difference 1.35 × 10; Pearson correlation 1.0). The computational time of FFT versus Conv2d was 0.995s versus 0.502s (HN), 0.650s versus 0.199s (prostate), and 0.370s versus 0.082s (liver). Dij construction time was 132.9s, 76.4s, and 31.9s, with assembly accounting for ∼89%. Workflow A performs no build but a full forward and backward convolution (2.166s, 0.832s, 0.368s) per-iteration; workflow B performs the one-time dij build (130.2s, 76.0s, 31.5s), then a sparse matrix-vector product (0.25s, 0.18s, 0.15s). The break-even points were 69, 116, and 145 iterations. Pencil beam kernel convolution can be formulated as Conv2d spatial convolution with machine-precision equivalence to FFT and competitive speed. The spatial-domain formulation enables a differentiable, dij-free optimization workflow that recomputes dose without storing a dose-influence matrix and that, for short optimization runs, is competitive with the traditional FFT-built sparse dij pipeline.
-
3. Fast and robust T1 mapping based on a 3D dual-echo UTE sequence (PETALUTE) for superparamagnetic iron oxide nanoparticle (SPION) biodistribution assessment.
3. 基于3D双回波UTE序列(PETALUTE)的快速稳健T1映射用于超顺磁性氧化铁纳米颗粒(SPION)生物分布评估PMID:DOI:日期:2026-09-24Superparamagnetic iron oxide nanoparticles (SPIONs), such as ferumoxytol, are promising theranostic agents that can be assessed with MRI. Relaxation time mapping can provide reproducible and quantitative biomarkers of SPION distribution, suitable for longitudinal and cross-individual studies. However, conventional approaches suffer from strong susceptibility artifacts, long echo times (TE), and prolonged scan times, which limit the accurate quantification of SPION biodistribution. To address the limitations of conventional approaches, this study aimed to develop a fast, B -corrected mapping protocol based on PETALUTE (a 3D dual-echo ultrashort echo time MRI sequence with a petal-like rosette k-space trajectory) using a variable flip-angle (VFA) acquisition for T mapping to assess ferumoxytol distribution. Agarose phantoms containing 0-5000 µg/mL ferumoxytol were scanned on a preclinical 7T MRI system using PETALUTE and RARE-VTR (rapid acquisition with relaxation enhancement and variable repetition time). PETALUTE T maps were computed from two VFA acquisitions (4° and 20°). Mean R values were correlated with ferumoxytol concentration to assess the method's reliability. For in vivo feasibility testing, mice bearing 4T1 mammary tumors and flank tumors were assigned to the control (n = 1) or ferumoxytol-injected group (n = 2; 40 mg/kg i.v.). Abdominal MRI scans were performed 24 h post-injection with both PETALUTE and RARE-VTR. Regions of interest in the thigh muscle, mammary tumors, and flank tumors were analyzed to compare the estimated T and R values obtained with both methods. In the phantom study, PETALUTE preserved positive contrast for ferumoxytol at all concentrations, whereas the conventional RARE-VTR sequence exhibited signal loss and hypointensity. For PETALUTE, there was a significant linear correlation between R and ferumoxytol concentration (R = 0.975, p < 0.01), while RARE-VTR showed no significant correlation (R = 0.672, p = 0.144). In vivo, PETALUTE provided high-resolution, non-gated, whole-abdominal images with short acquisition times (4 min 19 s). In ferumoxytol-injected mice, flank tumors exhibited T shortening, consistent with the expected iron accumulation. The dual-echo capabilities of PETALUTE facilitated observation of elevated T with preserved T*-weighted signal in one of the mammary tumors. The proposed PETALUTE-based T mapping enables fast and positive-contrast ferumoxytol imaging with higher spatial coverage and more stable measurements across a wider concentration range than conventional RARE-VTR T mapping.
-
4. Measurement-anchored Monte Carlo prediction of diagnostic x-ray air kerma using HVL-matched spectra and per-electron normalization.
PMID:DOI:日期:2026-09-18Quantitative Monte Carlo (MC) prediction of diagnostic x-ray air kerma is limited by mismatch between theoretical spectra and measured beam quality and by the lack of a reproducible normalization from source-photon tallies to mAs-based exposures. To test whether HVL-matched spectra combined with measurement-anchored per-electron normalization can predict free-in-air and transmitted air kerma under selected radiographic exposure settings and to evaluate the framework in PHITS and EGS5. Birch-Marshall spectra at 50, 80, and 120 kV were adjusted by tuning the Al-equivalent filtration parameter so that the theoretical HVL agreed with the measured HVL. The matched spectra were used as common input for PHITS and EGS5. Free-in-air air kerma was measured for 102 exposure conditions, and transmitted air kerma was measured after 2.0-cm PMMA or 0.5-cm Al for seven conditions at each tube voltage. From measured air kerma and MC air-kerma tallies expressed per source photon, we defined the normalization constant , the per-electron correction factor , and the tube-voltage-averaged coefficient . Predictions based on were compared with measurements using percentage error. Performance on the full free-in-air dataset was interpreted as agreement within the calibration dataset, whereas held-out-condition performance was assessed by leave-one-out cross-validation (LOOCV) on seven selected radiographic exposure settings at each tube voltage. Combined standard uncertainty was also summarized. After HVL matching, the free-in-air MC air-kerma tallies expressed per source photon differed between PHITS and EGS5, a finding interpreted primarily in relation to differences in source definition and source normalization. After measurement-based normalization with , predicted air kerma was generally consistent with measurements under both free-in-air and transmitted conditions. The largest mean percentage error was 7.8%, slightly exceeding the predefined ± 7.5% operational benchmark. The representative combined standard uncertainty was 5.6%; when the nominal tube-voltage setting was used directly as a simulation input, inclusion of the tube-voltage accuracy term increased it to 7.3%. Within the tested radiographic system and slab-transmission geometries, HVL-matched spectra combined with measurement-anchored per-electron normalization enabled prediction of air kerma under actual exposure conditions. Despite differences in the MC air-kerma tallies expressed per source photon, the final predicted values were generally consistent with measurements in both codes under the tested conditions.
-
5. A novel integrated circular radiography (ICRAD) phantom for evaluating non-uniform image quality metrics in radiography.
5. 一种用于评估放射摄影中非均匀图像质量指标的新型一体化环形放射摄影(ICRAD)模体PMID:DOI:日期:2026-09-18Anode heel effects have been shown to cause a non-uniform distribution of X-ray photon fluence, and anode angle could cause focal spot size variations across field. However, no previous study has investigated their effects on image quality metrics in radiography. The present study aimed to propose an integrated circular radiography (ICRAD) phantom for assessing non-uniform image quality metrics in digital radiography. The phantom was fabricated using multi-layer circular acrylic plates with various sized details and an outer ring of tungsten. It was exposed ten times at different tube voltage and current-time product settings using a digital radiographic system. The visible ratio (VR), normalized mutual information (nMI), and modulation transfer function at 10% (MTF) and 50% contrast (MTF) were calculated from different orientations to evaluate the non-uniform image quality in radiography. For comparison, a conventional contrast-detail radiography (CDRAD) phantom was also exposed ten times at the same tube voltage and tube current-time product, and rotated at angles of 0, 90, 180, and 270 degrees to understand the effect of anode angle on image quality evaluation using the inverse image quality figure (IQF). Statistical comparisons and correlation analysis were performed and the results were considered significant if P < 0.05. The results demonstrated that the VR, nMI, MTF, and IQF increased with tube voltage and tube current-time product, and all metrics were significantly correlated with each other. The VR, nMI, and MTF metrics were significantly higher in the cathode direction than in the anode direction, while the IQF metric was significantly greater when small details were placed toward the cathode direction compared to the anode direction. Moreover, the MTF metric was significantly lower in the cathode direction than in the anode direction. The proposed ICRAD phantom is a suitable tool for assessing non-uniform image quality and spatial resolution caused by the anode heel effect in digital radiography.
-
6. Comment on "Resilience-depletion hypothesis: Unifying BED from conventional to ablative radiotherapy".
PMID:DOI:日期:2026-09-18该文献暂无摘要。
-
7. Contour-regulated registration framework for Liver CT perfusion images.
PMID:DOI:日期:2026-09Liver computed tomography perfusion (CTp) imaging enables quantitative assessment of vascular dynamics but is highly susceptible to motion-induced artifacts arising from breath-hold variability and involuntary patient motion. These effects cause different portions of the liver to fall within the imaging field of view across time frames and introduce in-plane deformation, creating substantial challenges for image registration. Misregistration between distinct regions of interest disrupts temporal signal consistency and perfusion estimation, underscoring the need for robust registration strategies tailored for Liver CTp. To develop and evaluate a contour-regulated automated registration framework for correcting motion artifacts and aligning time-resolved images in Liver CTp series. Forty-six CTp datasets from 23 patients were analyzed; each dataset consisted of a pre-contrast static scan, a post-contrast high temporal resolution cine scan (59-79 time frames), and a post-contrast low temporal resolution helical scan (8-10 time frames). A 2D liver auto-segmentation nnU-Net model was trained on 23 whole liver contours that had been manually delineated on pre-contrast static images and applied to all 46 cine and helical series. The auto-segmented contours were used to regulate a two-stage registration pipeline consisting of affine registration followed by TransMorph-based deformable registration. The models with different parameters were trained by using intensity-corrected images on 36 randomly selected cases and tested on the remaining 10 cases. Performance of multiple registration model variants were evaluated against the unregistered series by using mean surface distance (MSD) and 95th percentile Hausdorff distance (HD95) on simplified 3D surfaces reconstructed from manually placed anchor points. Liver auto-segmentation achieved mean Dice similarity coefficients of 0.92 for helical scans and 0.89 for cine scans. Structure alignment was improved significantly compared with raw data after registration. The best-performing model had an auto-determined contour regularization weighting factor ( of 0 or 0.8, reduced the MSD from 5.1 mm in the unregistered data to 1.0 mm and HD95 from 9.7 mm to 3.0 mm in cine scans. In helical scans, MSD decreased from 3.2 mm to 1.0 mm and HD95 from 6.6 mm to 2.9 mm. The proposed contour-regulated, two-stage registration framework improved temporal alignment in dynamic Liver CTp images, providing a robust foundation for subsequent analysis and clinical assessment.
-
8. A correction to the bandwidth difference method for assessment of magnetic resonance static field homogeneity.
PMID:DOI:日期:2026-09Published guidance offers four methods of static field inhomogeneity measurement, including a bandwidth difference method. However, an error exists in the implementation of this method, which we demonstrate analytically and experimentally. To propose and validate a correction to the bandwidth difference method for quantifying . We outline a correction in the method for quantifying local by measuring spatial translations rather than diameter measurements between MRI images with different receive bandwidths. To validate the approach, we acquired images of a cylindrical phantom containing a fixed array of fluid-filled pins. We adjusted static field shims to create approximately linear and quadratic field perturbations and acquired high- and low-bandwidth spoiled gradient echo sequences with anterior-posterior (AP) and left-right (LR) frequency-encoding. We then measured translations of centroid pin locations between low- and high-bandwidth images. Finally, we propose and validate an implementation strategy using a spherical phantom. In both cases, a vendor-provided field mapping sequence provided reference homogeneity measurements. Under manually adjusted shim settings, root-mean-square (RMS) and peak-to-peak (PP) were 2.46 and 6.29 parts per million (PPM) respectively, measured with the field mapping technique. Results of the proposed bandwidth difference method showed strong agreement; RMS and PP were 2.38 and 6.22 PPM respectively for AP frequency-encoding and 2.38 and 6.08 PPM respectively for LR frequency-encoding. In a spherical phantom, the proposed method agreed with reference measurements to within 0.25 PPM (< 7%). However, PP was underestimated using the diameter-based method-in a spherical phantom, measured was 0.74 PPM compared to 3.52 and 3.76 PPM using the reference and revised methods, respectively. This work experimentally validates a revised bandwidth difference approach for quantification, showing that it remains sensitive under spatially nonlinear ; the diameter-based method is shown to be inaccurate for such cases.
-
9. Context-informed personalized segmentation from radiology reports: A fully automated framework for long-term liver tumor follow-up.
PMID:DOI:日期:2026-09Personalized segmentation has been shown to improve performance over generalized models in follow-up imaging; however, its robustness across large temporal gaps remains unclear. We propose a fully automated, context-informed personalization framework that integrates radiology report-derived clinical context with imaging features to improve longitudinal liver tumor segmentation. This retrospective study included 171 patients for generalized model training and 41 longitudinal patients with follow-up CT scans acquired 3-15 months after baseline for personalization and evaluation. We developed a U-Net-based vision-language segmentation framework that automatically summarizes free-text radiology reports, encodes them into language embeddings, and integrates them into intermediate image features to provide clinical context. A generalized model was trained using paired CT-report data. For each longitudinal patient, personalization was performed at the 3-month follow-up using either image-only input (vision-only personalization) or paired image-report input (context-informed personalization). Models were then evaluated on subsequent 6-15-month follow-up scans without further adaptation. Patients were stratified into Stable and Dynamic cohorts based on relative GTV volume variability. Performance was assessed using the Dice similarity coefficient (DSC) and LogPenalty Score (LPS), with additional ablation studies examining language models and report components. In the Dynamic cohort, vision-only personalization exhibited diminishing gains at later follow-up, whereas context-informed personalization maintained statistically significant improvements in ΔLPS at 9-15 months (p < 0.05). In the Stable cohort, both personalization strategies showed sustained performance with comparable segmentation accuracy, indicating that incorporating report-derived clinical context did not degrade performance in cases with limited anatomical variability. Ablation studies demonstrated that domain-specific encoder-based language models (BioClinicalBERT) outperformed larger generative models and that effective context integration did not require complex architectural modifications. Incorporating report-derived clinical context improves the longitudinal robustness of personalized liver tumor segmentation, particularly in patients with dynamic tumor evolution. These findings suggest that clinically grounded language representations can stabilize personalization across extended follow-up while enabling fully automated and scalable deployment.
-
10. Experimental investigation of metal artifact reduction using one-step spectral CT reconstruction.
PMID:DOI:日期:2026-09The constrained one-step spectral CT image reconstruction algorithm (cOSSCIR) is a model-based approach that iteratively estimates basis material maps directly from a set of transmission measurements. By incorporating a model of the imaging system's x-ray beam and detector response, the method can be applied to both dual-kV and photon-counting problems. Since the polyenergetic composition of the x-ray beam is incorporated into the reconstruction, cOSSCIR has the potential to address beam hardening metal artifacts using accurate spectral estimation for both modalities. Furthermore, the use of convex constraints in the inversion procedure can be leveraged to address photon starvation caused by metal using a masking technique. The purpose of this study was to experimentally investigate metal artifact reduction performance within a one-step framework for spectral CT reconstruction. Dual-kV and photon-counting transmission measurements were taken through a step-wedge phantom and were used to form spectral models for an energy-integrating and photon-counting detector for our benchtop micro-CT imaging system. Then experiments were performed using an electron-density rod phantom with and without metal to evaluate the effect of spectral modeling and masking on the cOSSCIR reconstructions for both imaging modalities. Further experiments were performed using a biological specimen to demonstrate cOSSCIR and the artifact reduction techniques on a phantom with more complicated structure. Finally, cOSSCIR was demonstrated on head CT data with dental hardware obtained from a first-generation silicon PCCT clinical prototype. The cOSSCIR reconstructions demonstrated a reduction in metal artifacts for both dual-kV and photon counting data. For a region between the metal inserts of the electron-density phantom, the mean absolute errors in the 60 keV dual-kV virtual mono-energetic images were 115 HU for FBP, compared to 87 HU and 41 HU using cOSSCIR and cOSSCIR with a mask, respectively. Likewise, the mean absolute errors in the 60 keV virtual mono-energetic images were 217 HU for FBP, 71 HU using cOSSCIR, and 22 HU using cOSSCIR with a mask in the 60 keV photon-counting virtual mono-energetic images. In a region adjacent to the metal, the dual-kV images had mean absolute errors of 100 HU for FBP, 53 HU for cOSSCIR, and 41 HU for cOSSCIR+Mask and the photon-counting images had errors of 74 HU for FBP, 27 HU for cOSSCIR, and 63 HU for cOSSCIR+Mask. The additional spectral information available from the photon-counting detector further reduced beam hardening and metal artifacts compared to the dual-kV images. cOSSCIR reduced metal artifacts in both dual-kV and photon-counting x-ray CT. When combined with a masking technique, the cOSSCIR reconstructions demonstrated further artifact reduction, although masking introduced new artifacts in some cases. In general, our results show that the cOSSCIR photon-counting reconstructions compare favorably to dual-kV and filtered backprojection, and when using a mask, can fully resolve regions in between two metal inserts for the objects scanned in this study.