JOURNAL OF PHYSICS D-APPLIED PHYSICS物理学D辑:应用物理学杂志
JOURNAL OF PHYSICS D-APPLIED PHYSICS(英文缩写 J PHYS D APPL PHYS),ISSN 0022-3727,eISSN 1361-6463,中文译名:物理学D辑:应用物理学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 3.409 | Q2 |
| 2022 | 3.400 | Q2 |
| 2023 | 3.100 | Q2 |
| 2024 | 3.200 | Q2 |
| 2025 | 3.200 | Q2 |
JOURNAL OF PHYSICS D-APPLIED PHYSICS 最新收录文献
-
1. Reassessing magnetic tunnel junction detectability for ultrasensitive sensing using small-field sensitivity and Jiles-Atherton modeling.
1. 利用小场灵敏度和Jiles-Atherton模型重新评估磁性隧道结用于超灵敏传感的可检测性PMID:日期:2026-07-02Magnetic tunnel junction (MTJ) sensors are attractive for detecting extremely small magnetic fields, yet their performance is often quantified using sensitivities derived from major loops or larger-field minor loops which inherently include hysteretic contributions. As a result, these conventional metrics significantly overestimate detectability by including irreversible processes that vanish in the small-field limit. Here, we systematically measure the low-field response of uniaxial MTJs under both ac and dc magnetic excitation and demonstrate a distinct transition from hysteretic to fully reversible behavior as the field amplitude is reduced. By adapting the Jiles-Atherton model to analyze MTJ conductance, we establish a unified framework that captures magnetization processes down to nanotesla range, yielding quantitative parameters that resolve reversible and irreversible dynamics with excellent fidelity. In the reversible regime, the sensitivity converges to a constant value of 0.55%Oe , defining an intrinsic, history-independent response of the MTJ. Importantly, this is less than half of the 1.2%Oe obtained from higher-field minor loop estimates but is physically representative of the sensing response in low-field operation. The constant and intrinsic sensitivity corresponds to the true value of detectability, confirmed by noise spectral density measurements under low-field ac excitation. These results establish a quantitative framework for MTJ evaluation that emphasizes intrinsic, hysteresis-free performance, providing both a realistic basis for calculating field detectability and a general methodology for probing magnetization in micron- and nano-scale ferromagnets.
-
2. The 2026 guided acoustic waves roadmap.
2. 2026年导声波路线图PMID:日期:2026-03-02Guided elastic waves are a truly cross-disciplinary key enabling technology. For more than five decades, surface acoustic wave (SAW) and bulk acoustic wave devices find widespread applications. Nowadays, different types of guided elastic waves cover the wide spectrum of applications spanning from quantum technologies to the life sciences, from controlling single excitations to macroscopic collective states in condensed matter. Six years after the first 2019 SAW roadmap, we believe it is time to make a step back and take a fresh look at the status of the field and its future challenges. Since the first roadmap in 2019, the spectrum clearly expanded and this new edition presents a current snapshot of the status of this vibrant field and prospects for potential future developments.
-
3. Emerging strategies in radiation therapy: promises and challenges of spatial fractionation, ultra-high dose rates, and nanoparticles.
3. 放射治疗中的新兴策略:空间分割、超高剂量率和纳米粒子的前景与挑战PMID:日期:2025-10-13Radiation therapy (RT) employs ionizing radiation to kill cancerous cells. However, delivering radiation to tumors, typically embedded within normal tissues, inevitably exposes healthy organs to radiation, leading to collateral damage. This creates a tradeoff between the tumor control probability and normal tissue complication probability, ultimately limiting the dose that can be safely administered. While highly conformal RT techniques have improved tumor targeting and treatment efficacy, they remain inadequate for treating large and radioresistant tumors, pointing out the need for alternative strategies. Spatially fractionated RT, ultra-high dose rate RT, and nanoparticle-enhanced RT are emerging techniques with promise in enhancing tumor control while minimizing normal tissue toxicity. Successful clinical translation of these advanced techniques requires cross-disciplinary efforts aimed at technological innovation, a deeper understanding of the underlying radiobiological mechanisms, and the development of early-phase clinical trials. This paper provides an overview of these techniques and their associated challenges and opportunities.
-
4. On the applicability of x-ray strain imaging using the edge illumination technique in biomedical applications.
4. 关于边缘照明技术X射线应变成像在生物医学应用中的适用性PMID:日期:2025-08-04Strain imaging using conventional x-ray tomography is a widely established technique for investigating the mechanical deformation of materials, including cement and batteries. However, its biomedical applications are primarily restricted to bone tissue due to the low contrast of soft tissues. X-ray phase contrast imaging, offering superior contrast-to-noise ratios in soft tissues, can in principle overcome this limitation. This study explores the feasibility of x-ray strain imaging for soft tissues using edge illumination (EI), a laboratory-based x-ray phase contrast technique. A phantom mimicking the mechanical properties of healthy and tumorous soft tissues, with a stiff inclusion invisible to conventional x-ray imaging, was tested alongside chicken soft tissue fixed in ethanol. While our study confirmed that EI phase contrast imaging provides improved contrast for such samples compared to absorption imaging, it also revealed a reduction in strain retrieval precision. Artefacts caused by absorbing bridges in the mask design and errors arising from differential phase signal integration, which vary spatially between scans, were identified as key limiting factors. Consequently, EI phase contrast strain imaging was unable to locate phantom inclusions based on mechanical contrast. However, EI's capability to increase spatial sampling frequency without compromising the field of view improved strain retrieval precision using its absorption contrast beyond that achieved with conventional x-ray strain imaging. These findings highlight the potential and challenges of applying EI to strain analysis in soft tissues, providing insights into its limitations and opportunities for further improvement.
-
5. Effects of excitation field amplitude on magnetic particle imaging performance: a modeling study.
5. 激励场幅度对磁粒子成像性能的影响:一项建模研究PMID:日期:2025-07-22Magnetic particle imaging (MPI) is a new tomographic imaging technique that can quantitatively correlate MPI signal intensity to the spatial distribution of magnetic nanoparticle (MNP) tracers. Due to its non-ionizing nature, low background signal from biological matrices, high contrast, and relatively good spatial and temporal resolution, MPI has been actively studied and applied to biomedical imaging and is expected to reach the clinical stage soon. To further improve the spatial resolution limit in MPI, researchers have been working towards optimizing the image reconstruction algorithms, magnetic field profiles, tracer designs, circuitry, etc. Recent studies reported that lower excitation field amplitudes can improve spatial resolution, though this comes at the expense of lower MPI signal and tracer sensitivity. Different excitation field profiles directly affect the collective dynamic magnetizations of tracers recorded by the receiver coil in MPI. However, there is a gap between understanding the relaxation dynamics of MNP tracers, the signal-to-noise ratio (SNR) of MPI signals, and the MPI spatial resolution. In this work, we used a stochastic Langevin equation with coupled Brownian and Néel relaxations to model the magnetic dynamics of different MNP tracers subjected to varying excitation fields. We analyzed the collective time-domain dynamic magnetizations (- curves), magnetic-field hysteresis loops ( curves), point spread functions (PSFs), higher harmonics, and SNR of the third harmonic to understand how the excitation field affects MPI performance. We employed Full Width at Half Maximum and SNR as evaluation metrics for imaging resolution and signal quality, respectively. Our study supports previous findings on the impact of excitation field amplitude on MPI performance while offering more profound insights into the interplay of nonequilibrium Néel and Brownian relaxation, tracer core size, and SNR.
-
6. Phase-restoring subpixel image registration: enhancing motion detection performance in Fourier-domain optical coherence tomography.
6. 相位恢复亚像素图像配准:增强傅里叶域光学相干层析成像中的运动检测性能PMID:日期:2025-02-21Phase-sensitive Fourier-domain optical coherence tomography (FD-OCT) enables , label-free imaging of cellular movements with detection sensitivity down to the nanometer scale, and it is widely employed in emerging functional imaging modalities, such as optoretinography (ORG), Doppler OCT, and optical coherence elastography. However, when imaging tissue dynamics , inter-frame displacement introduces decorrelation noise that compromises motion detection performance, particularly in terms of sensitivity and accuracy. Here, we demonstrate that the displacement-related decorrelation noise in FD-OCT can be accurately corrected by restoring the initial sampling points using our proposed Phase-Restoring Subpixel Image Registration (PRESIR) method. Derived from a general FD-OCT model, the PRESIR method enables translational shifting of complex-valued OCT images over arbitrary displacements with subpixel precision, while accurately restoring phase components. Unlike conventional approaches that shift OCT images either in the spatial domain at the pixel level or in the spatial frequency domain for subpixel correction, our method reconstructs OCT images by correcting axial displacement in the spectral domain (k domain) and lateral displacement in the spatial frequency domain. We validated the PRESIR method through simulations, phantom experiments, and ORG in both rodents and human subjects. Our approach significantly reduced decorrelation noise during the imaging of moving samples, achieving phase sensitivity close to the fundamental limit determined by the signal-to-noise ratio.
-
7. {"_":"Capillary-based, multifunctional manipulation of particles and fluids focused surface acoustic waves.","i":["via"]}
7. 基于毛细管的多功能粒子与流体操控聚焦表面声波PMID:日期:2024-05-07Surface acoustic wave (SAW)-enabled acoustofluidic technologies have recently atttracted increasing attention for applications in biology, chemistry, biophysics, and medicine. Most SAW acoustofluidic devices generate acoustic energy which is then transmitted into custom microfabricated polymer-based channels. There are limited studies on delivering this acoustic energy into convenient commercially-available glass tubes for manipulating particles and fluids. Herein, we have constructed a capillary-based SAW acoustofluidic device for multifunctional fluidic and particle manipulation. This device integrates a converging interdigitated transducer to generate focused SAWs on a piezoelectric chip, as well as a glass capillary that transports particles and fluids. To understand the actuation mechanisms underlying this device, we performed finite element simulations by considering piezoelectric, solid mechanic, and pressure acoustic physics. This experimental study shows that the capillary-based SAW acoustofluidic device can perform multiple functions including enriching particles, patterning particles, transporting particles and fluids, as well as generating droplets with controlled sizes. Given the usefulness of these functions, we expect that this acoustofluidic device can be useful in applications such as pharmaceutical manufacturing, biofabrication, and bioanalysis.
-
8. On the equivalence of the X-ray scattering retrieval with beam tracking and analyser-based imaging using a synchrotron source.
8. 关于利用同步辐射源的X射线散射反演与束流追踪及分析晶体成像的等价性PMID:日期:2023-08-18X-ray phase contrast imaging (XPCI) methods give access to contrast mechanisms that are based on the refractive properties of matter on top of the absorption coefficient in conventional x-ray imaging. Ultra small angle x-ray scattering (USAXS) is a phase contrast mechanism that arises due to multiple refraction events caused by physical features of a scale below the physical resolution of the used imaging system. USAXS contrast can therefore give insight into subresolution structural information, which is an ongoing research topic in the vast field of different XPCI techniques. In this study, we quantitatively compare the USAXS signal retrieved by the beam tracking XPCI technique with the gold standard of the analyzer based imaging XPCI technique using a synchrotron x-ray source. We find that, provided certain conditions are met, the two methods measure the same quantity.
-
9. One-Sided Multidimensional Statistical Significance Testing: A New Method of Calculating the Statistical Significance of Spectra Used to Demonstrate Magnetic Nanoparticle Sensitivity.
9. 单侧多维统计显著性检验:一种计算用于证明磁性纳米粒子灵敏度的光谱统计显著性的新方法PMID:日期:2022-05-26Estimating statistical significance of the difference between two spectra or series is a fundamental statistical problem. Multivariate significance tests exist but the limitations preclude their use in many common cases; e.g., one-sided testing, unequal variance and when few repetitions are acquired all of which are required in magnetic spectroscopy of nanoparticle Brownian motion (MSB). We introduce a test, termed the T-S test, that is powerful and exact (exact type I error). It is flexible enough to be one- or two-sided and the one-sided version can specify arbitrary regions where each spectrum should be larger. The T-S test takes the-one or two-sided p-value at each frequency and combines them using Stouffer's method. We evaluated it using simulated spectra and measured MSB spectra. For the single-sided version, mean of the spectrum, A-T, was used as a reference; the T-S test is as powerful when the variance at each frequency is uniform and outperforms when the noise power is not uniform. For the two-sided version, the Hotelling T2 two-sided multivariate test was used as a reference; the two-sided T-S test is only slightly less powerful for large numbers of repetitions and outperforms rather dramatically for small numbers of repetitions. The T-S test was used to estimate the sensitivity of our current MSB spectrometer showing 1 nanogram sensitivity. Using eight repetitions the T-S test allowed 15 pM concentrations of mouse IL-6 to be identified while the mean of the spectra only identified 76 pM.
-
10. {"_":"Production and loss of O(Δ ) at atmospheric pressure using microwave-driven microplasmas.","sub":["2",{"i":["g"]}],"sup":["1"]}
10. 利用微波驱动微等离子体在大气压下产生和损失O(Δ)PMID:日期:2021-12-29We have used arrays of microwave-generated microplasmas operating at atmospheric pressure to generate high concentrations of singlet molecular oxygen, O(Δ ), which is of interest for biomedical applications. The discharge is sustained by a pair of microstrip-based microwave resonator arrays which force helium/oxygen gas mixtures through a narrow plasma channel. We have demonstrated the efficacy of both NO and less-hazardous NO additives for suppression of ozone and associated enhancement of the O(Δ ) yield. Quenching of O(Δ ) by ozone is sufficiently suppressed such that quenching by ground state molecular oxygen becomes the dominant loss mechanism in the post-discharge outflow. We verified the absence of other significant gas-phase quenching mechanisms by measuring the O(Δ ) decay along a quartz flow tube. These measurements indicated a first-order rate constant of (1.2 ± 0.3) × 10 m s, slightly slower than but consistent with prior measurements of singlet oxygen quenching on ground state oxygen. The discharge-initiated reaction mechanisms and data analysis are discussed in terms of a chemical kinetics model of the system.