Forensic Science International法医学国际
Forensic Science International(英文缩写 FORENSIC SCI INT),ISSN 0379-0738,eISSN 1872-6283,中文译名:法医学国际 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.676 | Q2 |
| 2022 | 2.200 | Q1 |
| 2023 | 2.200 | Q1 |
| 2024 | 2.500 | Q1 |
| 2025 | 2.600 | Q1 |
Forensic Science International 最新收录文献
-
1. Infrared spectroscopy combined with interpretable machine learning for forensic identification and weathering time estimation of empty blow fly puparia.
PMID:日期:2026-09-29In this work, spectral data was used to identify the species and weathering time of blow fly puparia, which helps with the estimation of the minimum post-mortem interval (PMI) in forensic science. After a preliminary model selection stage, the two best-performing modeling approaches were compared: a classical Logistic Regression (LR) model and a more complex Convolutional Neural Network (CNN). By evaluating both models on these two tasks, we aim to assess the performance trade-offs between competitive traditional machine learning approaches and modern deep learning techniques. Moreover, beyond comparative performance results, an interpretability analysis was conducted to investigate which regions of the spectrum were most informative for weathering time estimation and species classification. These insights may guide future research in forensic entomology using IR spectroscopy by highlighting spectral regions associated with key biological changes related to ageing and species differentiation.
-
2. Rapid and cost-effective presumptive screening of firearm discharge-consistent metals via bromopyrogallol red colorimetry and machine learning.
PMID:日期:2026-09-25The identification of gunshot residues (GSR) is pivotal in forensic chemistry; however, standard confirmatory techniques, such as Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy (SEM/EDS), are often costly, time-consuming, and centralized in major urban facilities. This study proposes a rapid and cost-effective presumptive screening framework for firearm discharge-consistent metals (Pb and Sb), integrating Bromopyrogallol Red (BPR) colorimetry, digital image processing, multivariate chemometrics, and machine learning algorithms. One hundred samples were evaluated, including real hand swabs from shooters firing pistols, revolvers, and rifles, negative control samples ("non-shot"), and inorganic metallic standards. Digital images obtained in a standardized lighting environment were processed to extract quantitative chromatic descriptors across RGB and HSV/HSI color spaces. Exploratory analyses via Principal Component Analysis (PCA) and Non-Metric Multidimensional Scaling (NMDS) demonstrated robust class separation (PC1 + PC2 = 83.1%; NMDS stress = 0.027), with luminosity and intensity variables (V, I, R, and L) acting as primary discriminants. Supervised machine learning classifiers were developed to differentiate "shot" from "non-shot" samples, where tree-based algorithms-specifically Random Forest and XGBoost-achieved exceptional discriminatory performance, both yielding an Area Under the ROC Curve (AUC) of 0.998. Notably, the Random Forest model exhibited a minimal false-negative rate and superior probabilistic calibration, critical attributes for forensic decision-making. Executed in under 10 min per sample, this methodology provides a reliable, decentralized triaging solution to filter negative cases locally and prioritize high-probability samples for confirmatory SEM/EDS analysis.
-
3. A complex military repatriation cold case assisted by craniofacial superimposition.
PMID:日期:2026-09-25In 1950, partially skeletonized remains of a U.S. serviceman were recovered near the Pusan Perimeter, South Korea during the Korean War. Following initial analysis (no identification), the remains were returned to the U.S.A. and interred at the National Memorial Cemetery of the Pacific, Hawaii. In 2011, an exhumation was conducted for renewed accounting/repatriation analysis. Historical loss information indicated the skeleton may belong to one of 29 individuals. Twenty-eight of these individuals were excluded by DNA, dental records, induction chest radiographs, and/or biological profiles. DNA, dental records, and chest radiographs could offer no progress, however, for the last historically consistent individual-no DNA reference samples on file, all teeth present without restorations, and no induction chest X-ray(s). Identification via exclusion (and without biological indicators) was considered inadequate due to the possibility of inaccuracies in the loss information account. In 2024, a craniofacial superimposition (CFS) was undertaken using a photograph of the subject in an open-mouth smile and updated CFS technology. A military dress hat, similar to that worn by the subject served as a reference to set the focus distance for skull photography. Skull alignment included all boundaries within the face, eyes and nose in anatomically feasible positions, corresponding nasal bridge shape and alignment of a prominent canine on the subject's right side. This case illustrates the utility of engaging multiple analytical methods in complex cases and underscores CFS utility when a biological link from the skeleton to an individual cannot be provided by other means.
-
4. Stability of 3-chloromethcathinone and 4-chloromethcathinone during synthesis and storage.
PMID:日期:2026-09-23Synthetic cathinones have been among the most commonly identified substances in forensic analyses for several years. The most frequently detected representatives of this group include 4-CMC and 3-CMC. These substances are synthesized in clandestine laboratories across Europe, mainly in Poland and the Netherlands. The study was inspired by real casework involving samples from clandestine laboratories, in which concentrations of cathinone derivatives decreased or these compounds became undetectable during storage. To support the interpretation of analytical results from such samples - particularly in cases involving delayed analysis, long-term storage of seized materials, or re-analysis of archived samples - the stability of 3-CMC and 4-CMC dissolved in reagents used at various steps of their illicit production was studied, including environments with different pH values. Different storage temperatures were tested, and the stability of these compounds in single- and biphasic liquid systems was evaluated. The obtained results demonstrated that both compounds exhibit high stability in acidic and neutral solutions, especially at low temperatures (4°C and -20°C), where no significant changes in concentration were observed even after one year of storage. At room temperature (25°C) in less acidic environments (pH 5), slow degradation was observed. In alkaline conditions, rapid decomposition of both substances was noted, depending on their initial concentration and storage temperature, with 3-CMC degrading faster than 4-CMC. Additionally, in biphasic liquid systems, contact between the organic phase containing the cathinone and an alkaline aqueous phase significantly increased degradation over time, with this effect being more pronounced for 3-CMC than for 4-CMC.
-
5. Transcriptome-based postmortem interval prediction in the human dorsolateral prefrontal cortex using covariate-aware machine learning.
PMID:日期:2026-09-22Accurate estimation of the postmortem interval (PMI) remains a persistent challenge in forensic medicine, as it provides essential temporal evidence for death investigations and judicial proceedings. While messenger RNA (mRNA) degradation kinetics represents a promising molecular strategy for PMI prediction, most prior studies have been confined to small candidate gene sets and a limited range of human tissues. Here, we developed a covariate-aware transcriptomic framework for PMI estimation using RNA-seq data from 270 human dorsolateral prefrontal cortex (DLPFC) samples. Following expression filtering and trimmed mean of M-values (TMM) normalization, we prioritized candidate genes via covariate-adjusted gene-PMI association analysis and bootstrap elastic-net stability ranking within a repeated cross-validation framework. Panel-size and feature-set optimization identified a parsimonious 400-gene "Gene-only" configuration for downstream model comparison. Among all evaluated supervised learning models, the XGBoost algorithm achieved the best predictive performance, with a mean absolute error (MAE) of 9.48 h, root mean squared error (RMSE) of 12.57 h, Pearson correlation coefficient (r = 0.535), and predictive R (0.282). This model outperformed both null and covariate-only baseline models, although prediction errors varied across PMI intervals. Functional enrichment analysis of the final 400-gene signature revealed significant over-representation of immune effector processes, antigen processing and presentation, MHC class II-related pathways, and phagocytosis-associated biological processes.These findings demonstrate that postmortem brain transcriptomes contain reproducible PMI-associated signals and provide a candidate marker resource and standardized analytical framework for transcriptomic PMI prediction in forensic practice.
-
6. Medical and non‑medical gabapentinoid use in fatal drug poisonings in Norway: Linked postmortem toxicology and prescription data.
PMID:日期:2026-09-19Increasing prescribing and postmortem detection of gabapentinoids have raised concerns about their contribution to fatal poisonings, but information on medical and non-medical use remains limited. Forensic toxicology findings from fatal drug poisonings in Norway from 2005 to 2021 were linked to prescription data. Medical use was defined as ≥ 1 dispensing of the detected gabapentinoid during the two calendar months preceding death. Among 5075 fatal drug poisonings, gabapentinoids were detected in 668 cases (13%). Nearly one-quarter (24%) were not captured by the standard European Union Drugs Agency (EUDA) definition of drug-induced deaths. Pregabalin detections increased from 0.7% in 2006 to 18% in 2021, while gabapentin detections increased from 0.3% in 2008 to 11% in 2021. The median number of detected substances was five, with opioids and benzodiazepines co-detected in 87% and 82% of cases, respectively. Medical use was identified in 69% of gabapentin cases and 55% of pregabalin cases. Non-medical use increased over time, particularly for pregabalin, and was associated with illicit substance use. Median postmortem concentrations were 16 mg/L for gabapentin and 8.3 mg/L for pregabalin, with concentrations reaching 1400 mg/L and 320 mg/L, respectively. Higher concentrations were associated with medical use for both substances and with suicide for pregabalin. Gabapentinoids were increasingly detected in fatal drug poisonings in Norway. Non-medical use became more common over time, particularly for pregabalin. Because 24% of cases were not captured by the standard EUDA definition, the contribution of gabapentinoids to drug-related mortality may be underestimated.
-
7. Millimeter‑segmental analysis of individual equine mane hairs by LC/HRMS for revealing chronological drug distribution in anti‑doping investigations.
PMID:日期:2026-09-19Millimeter‑segmental analysis offers substantially improved temporal resolution over conventional bulk hair testing, yet no validated workflow has been established for equine mane hair. This proof‑of‑concept study presents the first liquid chromatography/high‑resolution mass spectrometry (LC/HRMS)‑based millimeter‑segmental workflow optimized for equine anti‑doping investigations. Mane hairs collected up to six months after a single 50‑mg oral administration of osilodrostat were cut into 2‑mm segments, extracted under standard conditions, and quantified using a fully-validated LC/HRMS method. The assay exhibited excellent linearity (r ≥ 0.999), negligible matrix effects, and high extraction recovery. Accuracy and precision consistently satisfied all predefined in-house acceptance criteria. Segmental concentration profiles revealed sharply localized osilodrostat incorporation peaks that migrated distally over time, yielding Average Highest‑Concentration Positions (AHCPs) of 6, 28, 56, and 118 mm at 1, 2, 3, and 6 months respectively. A literature-based mane hair growth rate of approximately 25 mm/month was used solely as a reference for temporal interpretation. The narrow peak widths indicate rapid follicular uptake during a short systemic exposure window and minimal post‑incorporation diffusion. In silico physicochemical predictions, in which osilodrostat exhibits low molecular weight, moderate lipophilicity, weak basicity, and high permeability, support passive follicular uptake and stable retention, consistent with established biochemical models of drug incorporation into hair. This validated workflow enables high‑resolution reconstruction of drug exposure timing and represents a significant methodological advancement for equine anti‑doping analysis, with potential applicability to other compounds exhibiting suitable physicochemical properties.
-
8. A novel four-teeth model for dental age estimation: Reliability, validity, and comparative accuracy with a seven-teeth approach.
PMID:日期:2026-09-18Dental age estimation plays a critical role in forensic identification and legal age determination, particularly in children and adolescents. Although multi-tooth regression models demonstrate high predictive accuracy, their application may be restricted in situations involving incomplete dentition or suboptimal radiographic visualization. The present study aimed to develop and validate a simplified four-teeth model for dental age estimation and to compare its performance with established seven-teeth models. A cross-sectional study was conducted using 2000 panoramic radiographs of Indian children aged 5-16 yrs. Dental maturity was assessed using the normalized open apices method. A regression equation based on four mandibular posterior teeth (34, 35, 36, 37) was derived using stepwise multiple linear regression and validated on an test dataset (n = 500). Model performance was evaluated using coefficient of determination (R²), Root Mean Square Error (RMSE), and Mean Absolute Error (MAE), and compared with Prabhu's population-specific and Cameriere's seven-teeth models. The four-teeth model demonstrated good predictive ability (R² = 69.6%, p < 0.0001), with an overall RMSE of 1.15 yrs and MAE of 0.95 yrs. The highest accuracy was observed in the 9-13 yrs age group (RMSE = 0.98 yrs), where performance was comparable to the seven-teeth models. Prediction error increased in the 13-16-yrs group (RMSE = 1.50 yrs), reflecting reduced discriminatory information following completion of root development. The model may therefore be useful as a simplified adjunct for dental age estimation primarily during the 5-13-yrs developmental period, in cases of incomplete dentition or compromised radiographic quality while external validation is required before broader forensic application.
-
9. A closer look at thin sections: White light profilometry applied for thickness estimation of embedded paint fragments.
9. 细看薄片:白光轮廓仪用于估计嵌入涂料碎片的厚度PMID:日期:2026-09-18Detailed analysis of multilayer paint such as automotive paints often involves thin sectioning of the paint fragments through cross-sectional or in-plane cuts. Thin sectioning of monolayer paint such as tool paints is less common but useful for instance as a sample preparation method for Microspectrophotometric (MSP) analysis. Based on an internal validation, the current procedure for tool paint cuts in our laboratory describes the use of 5 µm thin sections as opposed to the ASTM E2808-21a standard recommending a section thickness of approximately 3 µm. However, further microscopic examination of these 5 µm tool paint thin sections has raised questions as strong variations in colour intensities were observed. During this process concerns related to the reliability of the microtome's 5 µm setting were also raised. The current study focuses on a new method application to accurately assess the thickness of thin sections. Thin sections from 20 tool paint samples were prepared using cured Technovit 2000 LC resin and a rotary microtome. These thin sections were mounted on a glass slide and height differences were measured using white light profilometry. Generated heatmaps and in-depth data analysis allowed for average thickness calculations and yielded some unexpected observations. The results reveal substantial variation in thin section thicknesses with a clear tendency towards thinner sections (< 5 µm) than the microtome's setting (5 µm), as well as frequent vertical dislocations of the embedded paint fragments compared to the surface height of the thin section. Complementarily, IR peak absorbance values (band integration) of some of the main thin sections' resin IR peaks were plotted against the thicknesses estimated with profilometry, revealing for most measurements a linear correlation. These findings give confidence to the applied methodology and provide a calibration curve for future thin section thickness estimations using FTIR spectroscopy.
-
10. Detection of trace fentanyl in latent and developed fingermarks using atmospheric solids analysis probe (ASAP) mass spectrometry.
10. 利用常压固体分析探头(ASAP)质谱法检测潜在指纹和显现指纹中的痕量芬太尼PMID:日期:2026-09-18Latent fingermarks are vital evidence for identifying criminals using the unique ridge pattern and mass spectrometry can identify relevant chemical information from contact or exposure. Ambient ionisation mass spectrometry has many advantages that make it suitable for forensic workflows such as being user-friendly, low cost and having a small footprint. This work is concerned with detection of fentanyl, a highly potent synthetic opioid that has recently caused a significant number of overdoses, in latent fingermarks. A protocol was developed to produce fentanyl spiked fingermarks that were subsequently sampled using a liquid extraction method and analysed on a Waters RADIAN ASAP-MS. Initial results showed most fentanyl was recovered from a spiked fingermark and the detection limit was determined to be less than a nanogram. Latent fingermarks are typically visualised using an appropriate development technique before additional chemical information is recovered. Therefore, further studies assessed the ability to detect fentanyl in spiked fingermarks following three development techniques: cyanoacrylate (CyanoBloom), cyanoacrylate with UV dye (PolyCyano UV), and cyanoacrylate followed by staining with Basic Yellow 40 (BY40). Fentanyl was still detected after all three development methods tested, with detection limits reaching 10 ng or less present on the surface. This highlights that trace chemicals can be retained in fingermarks and recovered after development, the success of a simple liquid extraction method to recover analytes of interest and demonstrates how ambient ionisation methods are capable of reliably detecting analytes such as synthetic opioids from a complex matrix. This further exemplifies ambient ionisation as a solution to forensic testing backlogs by providing valuable information to criminal investigations quickly and effectively.