OPERATIVE DENTISTRY牙体修复学
OPERATIVE DENTISTRY(英文缩写 OPER DENT),ISSN 0361-7734,eISSN 1559-2863,中文译名:牙体修复学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.937 | Q2 |
| 2022 | 2.200 | Q3 |
| 2023 | 1.400 | Q3 |
| 2024 | 2.200 | Q2 |
| 2025 | 2.300 | Q2 |
OPERATIVE DENTISTRY 最新收录文献
-
1. Effects of Light Curing on the Mechanical Properties and Shade Stability of a Dual-Cure Bulk-Fill Resin Composite.
1. 光固化对双固化块状填充树脂复合材料的机械性能和遮光稳定性的影响PMID:DOI:日期:2026-07-06[中文摘要] 尽管双固化大块填充树脂复合材料(RCs)的使用日益增多,但光固化方案对其聚合及材料性能的影响仍不明确。了解这些影响对于优化临床结果至关重要。本研究比较了双固化大块填充树脂复合材料Bulk-EZ Plus(BZ)与光固化大块填充树脂复合材料Filtek-One Bulk-Fill(FB)的转化度、弯曲强度、弯曲模量、吸水性与溶解性以及颜色稳定性。试样被随机分为五组:BZ自固化组(BZ-SC)、BZ光照10秒组(BZ-10)、BZ光照20秒组(BZ-20)、FB光照20秒组(FB-20)和FB光照40秒组(FB-40)。采用傅里叶变换红外光谱法评估转化度,并依据ISO 4049:2019测定弯曲强度、弯曲模量以及吸水性和溶解性。使用分光光度计在24小时、7天和21天后测量试样在咖啡和蒸馏水中的颜色稳定性。采用双因素方差分析评估树脂复合材料类型和固化方案的影响。颜色稳定性采用重复测量和三因素方差分析(α = 0.05)。光照激活提高了BZ的弯曲模量(BZ-SC与BZ-10比较p = 0.012,BZ-SC与BZ-20比较p = 0.001)和弯曲强度(BZ-SC与BZ-20比较p = 0.018),并降低了吸水性(均p < 0.001)和溶解性(BZ-SC与BZ-10比较p = 0.028,BZ-SC与BZ-20比较p = 0.001)。将光照时间从20秒延长至40秒并未改变FB的弯曲强度和模量,也未改变其吸水性和溶解性(均p > 0.05)。光照激活改善了双固化大块填充树脂复合材料(Bulk-EZ Plus)的物理和力学性能,但延长光照时间并未改善光固化大块填充材料(Filtek-One Bulk-Fill)的性能。
[英文摘要] Despite the growing use of dual-cure bulk-fill resin composites (RCs), the influence of light-curing protocols on their polymerization and material behavior remains unclear. Understanding these effects is critical for optimizing clinical outcomes. This study investigated degree of conversion, flexural strength, flexural modulus, water sorption and solubility, and shade stability of a dual-cure bulk-fill RC, Bulk-EZ Plus (BZ), compared to a light-cured bulk-fill RC, Filtek-One Bulk-Fill (FB). Specimens were randomized into five groups: BZ self-cured (BZ-SC), BZ light-cured for 10-seconds (BZ-10), BZ light-cured for 20-seconds (BZ-20), FB light-cured for 20-seconds (FB-20), and FB light-cured for 40 seconds (FB-40). Degree of conversion was evaluated using FTIR spectroscopy, flexural strength and modulus, and water sorption and solubility were determined following ISO 4049:2019. Shade stability in coffee and distilled water was measured using a spectrophotometer after 24 hours, seven days, and 21 days. Two-way ANOVA assessed the effects of RC type and curing protocol. Shade stability was analyzed using repeated measures and three-way ANOVA (α = 0.05). Light activation increased the flexural modulus of BZ (p = 0.012 and p = 0.001 for BZ-SC vs. BZ-10 and BZ-20, respectively) and flexural strength (p = 0.018 for BZ-SC vs BZ-20), and reduced water sorption (both p < 0.001) and solubility (p = 0.028 for BZ-SC vs. BZ-10 and p = 0.001 for BZ-SC vs BZ-20). Extending light exposure from 20 seconds to 40 seconds did not change the flexural strength and modulus, or water sorption and solubility of FB (all p > 0.05). Light activation improved the physical and mechanical properties of the dual-cure bulk-fill resin composite (Bulk-EZ Plus), but increasing the light exposure time did not improve the properties of the light-cured bulk-fill material (Filtek-One Bulk-Fill).
-
2. Vital Pulp Preservation and Restorative Treatment for Young Permanent Incisors with Complicated Crown-Root Fractures: A Case Report.
2. 年轻恒切牙复杂冠根折的活髓保存与修复治疗:一例病例报告PMID:DOI:日期:2026-07-06[中文摘要] 本研究报道一例10岁男孩上颌中切牙(8、9号牙)复杂冠根折的病例。采用活髓切断术及iRoot BP Plus覆盖以保护牙髓,利用折断的冠部碎片恢复牙齿形态,成功恢复了双侧中切牙的美观与功能,患牙牙根继续正常发育。初次治疗后25个月,患者再次遭受外伤,导致左侧上颌中切牙折断冠再次脱落。鉴于折断冠结构完整,再次行断冠再接术以重塑患牙,最大程度恢复其外观。经40个月随访,8、9号牙的美观与功能保持满意,前牙正常咬合建立,治疗效果受到患者及其父母的高度认可。本病例为年轻恒牙因多次外伤所致复杂冠根折的处理提供了临床参考,强调了牙髓保存、保守修复及预防措施的重要性。
[英文摘要] This study reports a case of complicated crown-root fractures of the maxillary central incisors (teeth 8 and 9) in a 10-year-old boy. Vital pulpotomy and iRoot BP Plus capping were performed to protect the pulp. The fractured crown fragments were used to restore the tooth morphology, and the esthetics and function of both central incisors were restored. The roots of the affected teeth continued to develop normally. Twenty-five months after the initial treatment, the patient suffered another trauma, resulting in a second dislodgement of the fractured crown of the left maxillary central incisor. Given the structural integrity of the fractured crown, reattachment was performed again to reshape the tooth, thereby restoring its appearance to the greatest extent possible. After a 40-month follow-up, the esthetics and function of teeth 8 and 9 remained satisfactory. Normal anterior occlusion was established, and the treatment outcome was highly appreciated by the patient and his parents. This case provides clinical detail useful for managing complex crown and root fractures caused by multiple traumas in young permanent teeth, emphasizing the importance of pulp preservation, conservative restoration, and preventive measures.
-
3. Bonding Performance of a Bisphenol A-Free Universal Adhesive to Sound and Caries-Affected Dentin.
3. 无双酚A通用粘接剂对健康及龋影响牙本质的粘接性能PMID:DOI:日期:2026-07-06[中文摘要] 当前通用型粘接剂对龋影响牙本质的粘接性能不可靠,并会释放双酚A(BPA)。本研究比较了一种无BPA通用型粘接剂与其前代产品(含双酚类)在健康牙本质和龋影响牙本质上的粘接性能及界面特征。本研究使用240颗人磨牙:120颗为健康牙本质,120颗为龋影响牙本质(CAD)。制备牙本质表面后,分别使用Scotchbond Universal Plus(SBUP/无BPA)或Scotchbond Universal(SBU/含BPA),采用酸蚀-冲洗(ER)或自酸蚀(SE)模式进行粘接。树脂-牙本质粘接试件(1 mm²)于水中储存24小时和1年后进行微拉伸粘接强度(μTBS)测试。通过扫描电子显微镜(SEM)分析断裂面图像。数据采用三因素方差分析和Bonferroni事后检验(α < 0.05)。每组另制备3颗牙齿,将粘接剂用荧光染料(罗丹明B)染色,以评估粘接剂向牙本质的扩散情况。纵向切片后,制备的界面储存24小时和1年,浸入荧光素染料中,在共聚焦激光扫描显微镜(CLSM)和SEM下检查(n = 3)。24小时时,CAD在所有组中的μTBS平均值均显著低于健康牙本质(p < 0.0001)。健康牙本质上的SE模式未显示降解或荧光素渗透迹象。ER模式下的SBU(CAD)在两个储存期均显示最低的μTBS平均值。两种粘接剂的ER模式在健康牙本质和CAD的混合层下方随时间推移均显示暴露的胶原纤维和荧光素渗透。尽管SBUP在CAD中显示出更深的粘接剂扩散,但水储存一年后,SBUP(ER和SE)与SBUSE之间的μTBS无显著差异。无BPA和含BPA粘接剂对健康牙本质均产生相似的短期和长期μTBS。对CAD的粘接强度因材料和处理模式而异。SEM图像的定性表现提示,无BPA粘接剂在24小时时可能增强CAD中的界面扩散。然而,两种粘接剂在水储存一年后均表现出降解。
[英文摘要] Current universal adhesives exhibit unreliable bonding to caries-affected dentin and release bisphenol A (BPA). This study compares a BPA-free universal adhesive with its predecessor (bisphenol-based) to assess bonding performance and interfacial characteristics on sound and caries-affected dentin. Two hundred forty human molars were used in this study: 120 with sound dentin and 120 with caries-affected dentin (CAD). The dentin surfaces were prepared and bonded with Scotchbond Universal Plus (SBUP/BPA-free) or Scotchbond Universal (SBU/BPA-containing) using etch-and-rinse (ER) or self-etching (SE) modes. Resin-dentin bonded specimens (1 mm2) were stored in water for 24 hours and one year and tested for microtensile bond strength (μTBS). The failure images were analyzed through scanning electron microscopy (SEM). Data were submitted to three-way ANOVA and Bonferroni post hoc tests (α < 0.05). Three additional teeth were prepared for each group for evaluation of adhesive diffusion into dentin by dyeing the adhesives with a fluorochrome (Rhodamine B). After longitudinal sectioning, the generated interfaces were stored for 24 hours and one year, immersed in fluorescein dye and examined under confocal laser scanning microscopy (CLSM) and SEM (n = 3). CAD showed μTBS mean values significantly lower (p < 0.0001) than those of sound dentin for all groups at 24 hours. The SE mode on sound dentin showed no signs of degradation or fluorescein infiltration. SBU in the ER mode (CAD) showed the lowest mean μTBS in both storage periods. The ER mode for both adhesives showed exposed collagen fibrils and fluorescein infiltration underneath the hybrid layer of the sound and CAD over time. Although SBUP showed deeper adhesive diffusion into the CAD, no significant difference in μTBS was found between SBUP (ER and SE) and SBUSE after a year of water storage. Both the BPA-free and BPA-containing adhesives produced similar short- and long-term μTBS to sound dentin. Bond strengths to CAD varied by material and conditioning mode. Qualitative appearance of SEM images suggests that interfacial diffusion in CAD at 24 hours may be enhanced for the BPA-free adhesive. However, both adhesives exhibited degradation after one year of water storage.
-
4. Rate of Initial Proximal Caries Lesion Progression in High Caries-Risk Adults.
4. 高龋风险成人邻面初始龋损的进展率PMID:DOI:日期:2026-07-06In adults, caries lesions develop predominantly on proximal surfaces; however, evidence regarding the rate of proximal caries progression in this population remains limited. A clearer understanding of the progression rate of proximal caries in adults is essential for establishing appropriate radiographic examination intervals and optimizing the timing of operative interventions. To evaluate the rate of radiographic progression of initial proximal caries lesions and the factors associated with it. Serial bitewing radiographs from 105 patients, aged 18-61 years, were retrospectively analyzed for the progression of 364 enamel and outer dentin proximal caries lesions. The interval between baseline and follow-up radiographs ranged from six to 72 months. Lesion progression across study variables was summarized using descriptive statistics. A multivariable generalized estimating equation (GEE)-based Poisson regression model with robust variance estimation was performed to identify factors associated with proximal caries progression, including patient-level variables (age, gender, fluoride varnish exposure, plaque score, BOP score, DMFT, and DMFS) and tooth-level variables (jaw, tooth type, surface, and initial lesion depth), while accounting for clustering of lesions within patients and variable follow-up duration (p < 0.05; 95% CI). The mean interval between the initial and follow-up radiographs was 19.9 ± 12.6 months (median = 18 months). Caries progression was observed in approximately one-third of the initial proximal lesions (112 lesions; 30.8%). No lesions progressed from enamel to inner dentin, and only 12 of 43 outer dentin lesions advanced to inner dentin. According to multivariable GEE Poisson regression analysis, maxillary lesions exhibited a higher rate of progression than mandibular lesions (IRR 1.52; 95% CI 1.07 - 2.16), and lesions on distal surfaces demonstrated a higher progression rate than those on mesial surfaces (IRR 1.37; 95% CI 1.01 - 1.85). The rate of proximal caries progression was relatively low. Tooth location (maxillary arch) and distal surfaces were the only significant predictors of lesion progression.
-
5. Effect of Intracoronal Barrier Location on Bleaching Efficacy and Peroxide Diffusion.
5. 冠内屏障位置对漂白效果和过氧化物扩散的影响PMID:DOI:日期:2026-07-06[中文摘要] 牙髓腔内屏障位置对不同牙区漂白效果及过氧化氢扩散的影响尚不明确。本研究分析了颈屏障位置对牛牙内漂白过程中不同牙区颜色变化及过氧化氢扩散的影响。将80颗牛切牙于牙根处截断,截断位置位于釉牙骨质界(CEJ)根方5 mm处。使用树脂改性玻璃离子水门汀制作2 mm厚的颈部漂白屏障。根据颈屏障相对于CEJ的位置将牙齿分为两组(n = 40):CEJ冠方或根方。第一阶段,将40颗牙齿(每组颈屏障各20颗)用马血染色。使用60 μL 35% H₂O₂进行内漂白,共三个疗程,间隔七天。使用便携式分光光度计评估根区、颈区和切区的颜色变化及白度指数(三因素方差分析,Tukey事后检验)。第二阶段,剩余40颗牙齿接受45分钟漂白疗程,采用白细胞晶体酶与过氧化物酶之间的酶反应法分析H₂O₂扩散(单因素方差分析,Tukey事后检验)。置于CEJ根方的屏障在21天时,根区(ΔE00 = 19.79,p = 0.02;ΔWID = 19.69,p < 0.001)和颈区(ΔE00 = 10.05,p = 0.03;ΔWID = 16.08,p = 0.02)的颜色差异和白度指数均显著大于置于CEJ冠方的屏障;切区未见显著差异(ΔE00 = 8.17,p = 0.07;ΔWID = 19.09,p = 0.08)。根方屏障的过氧化氢扩散显著高于冠方屏障(2.2 μL vs 1.2 μL,p = 0.001)。根区和颈区的颜色变化取决于颈屏障位置。置于CEJ根方的屏障在这些区域提供了更好的漂白效果。然而,当屏障置于根方时,过氧化氢扩散也增加。
[英文摘要] The influence of intracoronal barrier positioning on bleaching effectiveness in different tooth regions and on hydrogen peroxide diffusion remains unclear. This study analyzed how the positioning of the cervical barrier affects chromatic changes in different dental regions and the diffusion of hydrogen peroxide in bovine teeth undergoing internal bleaching. Eighty bovine incisors were sectioned at the root, at a position 5 mm apical to the cementoenamel junction (CEJ). A 2-mm-thick cervical bleaching barrier was fabricated using resin-modified glass ionomer cement. The teeth were divided into two groups (n = 40) based on the positioning of the cervical barrier: coronal or apical to the CEJ. In the first phase, 40 teeth (n = 20 of each cervical barrier group) were stained with equine blood. Internal bleaching was performed with 60 μL of 35% H2O2 over three sessions at seven-day intervals. Chromatic change and whiteness index were assessed in root, cervical, and incisal regions using a portable spectrophotometer (three-way ANOVA, Tukey post hoc test). In the second phase, the remaining 40 teeth underwent a 45-minute whitening session and were analyzed for H2O2 diffusion using an enzymatic reaction method between the leucocrystal enzyme and peroxidase. (one-way ANOVA, Tukey post hoc test). The barrier placed apical to the CEJ showed significantly greater chromatic differences and whitening index than the coronally placed barrier in the root (ΔE00 = 19.79, p = 0.02; ΔWID = 19.69, p < 0.001) and cervical (ΔE00 = 10.05, p = 0.03; ΔWID = 16.08, p = 0.02) regions at 21 days; no significant differences were observed in the incisal region (ΔE00 = 8.17, p = 0.07; ΔWID = 19.09, p = 0.08). Hydrogen peroxide diffusion was significantly higher for the apical barrier than the coronal barrier (2.2 μL vs 1.2 μL, p = 0.001). Chromatic differences in the root and cervical regions depended on cervical barrier position. A barrier apical to the CEJ provided greater bleaching effectiveness in these regions. However, hydrogen peroxide diffusion was also increased when the barrier was positioned apically.
-
6. Surface, Colorimetric, and Optical Properties of New-Generation Lithium Disilicate Ceramics.
6. 新一代二硅酸锂陶瓷的表面、比色和光学性能PMID:DOI:日期:2026-07-06[中文摘要] 二硅酸锂基玻璃陶瓷(LDC)广泛用于美学修复,但其表面和光学行为可能因组成和表面处理程序而异。本研究的目的是比较不同组成的LDC材料在经抛光或上釉处理后的表面、比色和光学性能。通过切割四种组成的LDC CAD/CAM块材(IPS e.max CAD [IPS]、Amber Mill [AM]、Amber Mill Direct [AMD]、Initial LiSi [ILS])制备矩形试件。记录基线表面粗糙度(Ra)、颜色、半透明参数(TP)、对比度(CR)、乳光参数(OP)和光泽度(GU)值。每组根据表面处理分为两个亚组,一组进行上釉,另一组进行抛光,随后进行处理后测量(n = 10)。根据CIEDE2000公式计算每组的颜色变化(ΔE00)。除基线和最终Ra、TP、CR、OP和GU测量外,还通过从抛光或上釉后获得的最终值中减去基线值来计算这些参数的变化(ΔRa、ΔTP、ΔCR、ΔOP和ΔGU)。每组额外制备一个试件用于扫描电子显微镜(SEM)分析。采用Mann-Whitney U检验、Kruskal-Wallis H检验和Wilcoxon符号秩检验进行统计分析(α = 0.05)。表面、比色和光学性能因LDC材料类型和表面处理方法的不同而存在显著差异。与抛光相比,IPS、AMD和ILS上釉后的Ra值显著降低(p = 0.016),SEM分析证实了这一点。在所有材料组中,两种表面处理均较基线显著降低了Ra值(均p ≤ 0.013)。IPS(p = 0.011)和ILS(p = 0.0001)上釉后的平均ΔE00值高于抛光。对于IPS,上釉试件的TP值低于抛光试件(p = 0.001),而CR值则呈现相反趋势(p = 0.001)。无论LDC材料类型如何,上釉产生的OP值均显著低于抛光(均p ≤ 0.041),GU值均显著高于抛光(均p ≤ 0.023)。LDC材料的表面、比色和光学性能因表面处理方法和材料组成而异。虽然两种表面处理均有效降低了表面粗糙度,但上釉更显著地增强了表面光泽度和乳光性,但引起了材料特异性的颜色变化。与其他LDC材料相比,上釉还增强了IPS e.max CAD的半透明性。
[英文摘要] Lithium disilicate-based glass-ceramics (LDC) are widely used for esthetic restorations, yet their surface and optical behavior can vary depending on the composition and surface treatment procedure. The purpose of this study was to compare the surface, colorimetric, and optical properties of LDC materials with different compositions after being subjected to polishing or glazing. Rectangular specimens were prepared by sectioning four compositions of LDC CAD/CAM blocks (IPS e.max CAD [IPS], Amber Mill [AM], Amber Mill Direct [AMD], Initial LiSi [ILS]). Baseline surface roughness (Ra), color, translucency parameter (TP), contrast ratio (CR), opalescence parameter (OP) and gloss (GU) values were recorded. Each group was divided into two subgroups according to surface treatments, one undergoing glazing and the other polishing, followed by post-treatment measurements (n = 10). Color change (ΔE00) for each group was calculated based on the CIEDE2000 formula. In addition to baseline and final Ra, TP, CR, OP, and GU measurements, the changes in these parameters (ΔRa, ΔTP, ΔCR, ΔOP, and ΔGU) were calculated by subtracting the baseline values from the final values obtained after polishing or glazing. One extra specimen from each group was prepared for scanning electron microscopy (SEM) analysis. Mann-Whitney U, Kruskal-Wallis H, and Wilcoxon signed-rank tests were used for statistical analysis (α = 0.05). The surface, colorimetric, and optical properties differed significantly based on the type of LDC material and the surface treatment method. The Ra values of IPS, AMD, and ILS decreased significantly after glazing compared to polishing (p = 0.016), which was confirmed by SEM analysis. Both surface treatments significantly reduced Ra values compared with baseline across all material groups (all p ≤ 0.013). Glazing resulted in higher mean ΔE00 values than polishing for IPS (p = 0.011) and ILS (p = 0.0001). For IPS, TP values were lower in the glazed specimens than those that were polished (p = 0.001), whereas the opposite trend was observed for CR values (p = 0.001). Regardless of the LDC material type, glazing produced significantly lower OP values (all p ≤ 0.041) and higher GU values (all p ≤ 0.023) than polishing. Surface, colorimetric, and optical properties of LDC materials varied depending on the surface treatment method and material composition. While both surface treatments effectively reduced surface roughness, glazing enhanced surface gloss and opalescence more prominently, but induced material-specific color changes. Glazing also enhanced the translucency of IPS e.max CAD compared to other LDC materials.
-
8. Effects of Charcoal-Based Mouthwashes on Color Change and Surface Roughness of a Stained Resin Composite.
PMID:DOI:日期:2026-06-08Charcoal-based mouthwashes have recently gained popularity, but current evidence on their effects on the color change (ΔE00) and surface properties of resin composites is limited. This study aimed to evaluate the effects of five charcoal-based mouthwashes on the color change and surface roughness (Ra) of a stained resin composite. Seventy disc-shaped resin composite specimens (Filtek Z250) were prepared and immersed in coffee for 12 days. The specimens were then randomly distributed into seven groups (n = 10), based on mouthwash used: five charcoal-based mouthwashes (Hello Activated Charcoal Extra Freshening Mouthwash, My Magic Mud Activated Charcoal Alcohol-Free Oral Rinse, Dr. Jones' Naturals Activated Charcoal Mouthwash, The Humble Co. Natural Mouthwash Charcoal, and Colgate Plax White + Charcoal), one hydrogen peroxide-based mouthwash (Crest 3D White), and artificial saliva. Each specimen was immersed in the relevant mouthwash for 60 seconds, rinsed with water for 30 seconds, and then immersed again in a fresh mouthwash solution for 60 seconds to simulate daily mouthwash use. This cycle was repeated to represent 1, 2, 3, 4, and 12 weeks of use. Color measurements were performed at baseline, after staining, and after 1, 2, 3, 4, and 12 weeks. Surface roughness was evaluated after staining and after 1, 2, 3, 4, and 12 weeks of immersion. The surface morphology of the specimens was examined using a scanning electron microscope. The data were analyzed using repeated measures ANOVA and Tukey's test (α = 0.05). After immersion in coffee, the resin composite exhibited discoloration above the 50:50% acceptability threshold (AT) (ΔE00: 1.8). After 12 weeks of use, only one charcoal-based mouthwash, Colgate Plax White + Charcoal, and Crest 3D White reduced the ΔE00 of the resin composite below the AT, but both showed a significant increase in Ra (p < 0.001) and caused changes in surface morphology of the resin composite. The other charcoal-based mouthwashes did not cause an increase in Ra (p > 0.05) but failed to reduce the ΔE00 of the material below this threshold. All charcoal-based mouthwashes, except Colgate Plax White + Charcoal, maintained surface integrity but failed to reduce the color change below the AT. The hydrogen peroxide-based mouthwash provided color improvement on the resin composite but led to increased surface roughness.
-
9. Influence of Endodontic Access and Thermocycling on the Fracture Resistance of CAD/CAM Lithium Disilicate Anterior Crowns.
9. 根管入路和热循环对CAD/CAM二硅酸锂前冠抗折性能的影响PMID:DOI:日期:2026-06-08Catastrophic failures in lithium disilicate single-unit prostheses in the mandibular anterior region, particularly when subjected to endodontic access for root canal treatment, represent a significant clinical concern. This in vitro study evaluated the fracture resistance of CAD/CAM-fabricated lithium disilicate intact and endodontically accessed crowns, with and without aging through thermocycling. A mandibular right central incisor typodont was prepared and scanned for CAD/CAM fabrication of a lithium disilicate crown. Eighty crowns were milled, treated, etched, primed, and cemented to printed resin dies. The crowns were divided into eight groups based on endodontic access location (facial, incisal, or lingual) and thermocycling condition (presence or absence). All groups underwent vertical loading until fracture, and fracture resistance was measured. Fractured crowns were analyzed for crack patterns and failure modes using scanning electron microscopy. Two-way ANOVA assessed the effects of access type on fracture resistance, while one-way ANOVAs with Tukey's HSD post hoc tests analyzed fracture resistance across aging conditions. Fracture resistance was significantly affected by endodontic access type and thermocycling (p < 0.001). Non-thermocycled, intact crowns had the highest fracture resistance (1218.0 ± 174.8 N), while thermocycled crowns with incisal access demonstrated the lowest resistance (720.9 ± 98.3 N). Lingual access crowns displayed higher fracture resistance than facial and incisal access crowns, although resistance significantly decreased with thermocycling (p = 0.008). SEM analysis revealed that lingual access crowns visually appeared to exhibit less irregular crack patterns compared to facial and incisal access crowns, which displayed more numerous and irregular crack lines. Endodontic access reduced fracture resistance; however, thermocycling had a statistically significant effect only in the lingual access group. A conservative lingual access preserved integrity similarly to intact crowns, making it preferable for mandibular restorations. All crowns met minimum clinical fracture resistance standards, suggesting that crown replacement may not be necessary with conservative access designs. Variations between aged and non-aged specimens should be considered when interpreting in vitro data.
-
10. Color Match of Single-Shade and Group-Shade Resin Composites: A Visual and Instrumental Analysis.
10. 单色与分组色树脂复合材料的颜色匹配:视觉与仪器分析PMID:DOI:日期:2026-06-08Single-shade materials are favored for simplifying clinical workflows without compromising the esthetics of restorations, although evidence supporting their use remains limited. Therefore, this laboratory evaluated color match of single-shade versus group-shade resin composites. Sixty sound human molars were divided into three subgroups (n = 20), based on the tooth-shade correspondence for the tested group-shade resin composite: L (light) including A1, B1, B2, C1 and D2; M (medium) including A2, A3, C2, D3 and D4, and D (dark) including A3.5, A4, B3, B4, C3 and C4 shaded teeth. Standardized class V cavities (4 × 4 × 2 mm) were prepared. Half of the specimens within each subgroup were restored with single-shade (Omnichroma), while the other half was restored with group-shade resin composite (SimpliShade). Tooth/restoration ΔE00 color differences were calculated at 24 hours (T1), and after seven days (T2) by a spectrophotometer (VITA Easyshade V). A visual analysis was performed after 14 days (T3). Also, a novel computer vision algorithm (CVA) analysis, was employed to evaluate color match at three weeks (T4). Student's t-test was used to compare the two groups within each subgroup and time point and one-way ANOVA was used to compare the values between subgroups, within each group and time point. Instrumental analysis at T1 showed higher mean ΔE00 for single-shade compared to group-shade resin composites (p < 0.05), within each subgroup. Within single-shade specimens, significantly higher mean ΔE00 differences were found at T2 between D (8.24 ± 1.85) vs L (5.65 ± 2.24) (p = 0.007) and M (6.49 ± 2.5) (p = 0.03). Within group-shade specimens, a significant difference was found between L (4.16 ± 2.19) and M (2.17 ± 1.05) at T1 (p = 0.034). Visual analysis reported a significant difference (p = 0.0153) between L-group shade (1.03 ± 1.04) and L-single shade (1.97 ± 0.78) restorations (p = 0.0153). No significant differences were detected when CVA analysis was employed. Overall, group-shade showed better color match than single-shade resin composites, especially when spectrophotometric and visual evaluation were employed.