MAGNETIC RESONANCE IN MEDICINE 最新收录文献
-
1. {"_":"Simultaneous T and T Mapping in the Brain With QuantoRAGE: An MP2RAGE Variant Using T-Prepared Inversion.","sub":["1","2","2"]}
PMID:日期:2026-10-04To develop and validate a repeatable and reproducible approach, QuantoRAGE, for simultaneous whole-brain T and T mapping using adiabatic magnetization preparation. QuantoRAGE is a 3D FLASH-based sequence using an adiabatic T-prepared inversion followed by two readout blocks. Sequence repetitions with different preparation durations and inversion times provide T- and T-weighted images. Quantitative parameters are voxel-wise estimated by matching signal evolutions to a dictionary generated from extended phase graph simulations. To accelerate the method, the protocol was optimized using Cramér-Rao lower bound analysis, and a neural-network was trained on sequence-specific dictionaries for fast matching. The optimized protocol was evaluated in phantom and healthy volunteers at 3 T and compared against reference MP2RAGE T and multi-echo spin-echo T measurements. In vivo repeatability and reproducibility were quantified using scan-rescan experiments. Feasibility of QuantoRAGE at 7 T was tested in vivo. At 3 T, T and T phantom quantification agreed with nominal values (T: r = 0.98, T: r = 0.99). In eight healthy volunteers, high repeatability (bias ± SD, T: 14.1 ± 30.2 ms, T: 1.2 ± 1.7 ms) and reproducibility (T: 18.9 ± 32.6 ms, T: 1.1 ± 2.1 ms) were observed across brain regions, with T estimates comparable to reference methods (r = 0.96, slope = 0.74), and T underestimated (r = 0.79, slope = 0.44). Fast matching produced results consistent with dictionary-matching and significantly reduced parameter estimation time. At 7 T, the adiabatic preparation resulted in homogeneous T and T maps at 0.8-mm isotropic resolution. QuantoRAGE enabled reproducible simultaneous T and T mapping at 3 T, providing an efficient framework for longitudinal and cross-sectional quantitative MRI studies and showed feasibility at 7 T.
-
2. Non-Rigid Motion-Compensated MR Multitasking for Free-Breathing Low-Dose Dynamic Contrast-Enhanced MRI in the Abdomen.
2. 用于腹部自由呼吸低剂量动态对比增强MRI的非刚性运动补偿MR多任务成像PMID:日期:2026-10-04To improve free-breathing low-dose quantitative dynamic contrast-enhanced (DCE) MRI for imaging pancreatic ductal adenocarcinoma. We introduced non-rigid (NR) motion compensation (MoCo) into MR Multitasking using a novel "in-subspace" formulation that directly applies motion fields to spatial feature maps (eigenimages), reducing computational cost relative to warping in the spatiotemporal domain. We evaluated NR-MoCo DCE Multitasking in n = 11 healthy volunteers scanned using 20% (0.02 mmol/kg) of the standard Gd dose; 10 of these volunteers underwent a repeat 20%-dose scan after exiting and re-entering the scanner. Data were reconstructed without MoCo (No-MoCo), translation MoCo (Tr-MoCo), and NR-MoCo Multitasking. We assessed motion by measuring respiratory motion energy ratio and liver dome position across time within the end-expiration respiratory bin. We estimated pharmacokinetic parameters from all reconstruction frameworks, evaluating the test-retest repeatability of parameters in the head, body, and tail of the pancreas. Non-rigid MoCo of eigenimages was compatible with MR Multitasking, using > 3000× fewer Fourier transforms and motion deformations. Compared with Tr-MoCo and No-MoCo, NR-MoCo showed the best performance in reducing artifactual intra-bin motion along DCE dimension, indicated by the smallest liver-dome position variation (p = 0.026). NR-MoCo lowered the effective tensor rank and improved repeatability of quantitative kinetic vascular properties across healthy volunteers as compared to No-MoCo. The Bland-Altman analysis indicated that NR-MoCo narrowed K limits of agreement by 2.1× relative to No-MoCo and Tr-MoCo. Non-rigid motion compensation reduces respiratory motion and improves K repeatability in low-dose free-breathing, whole-abdomen quantitative dynamic contrast enhanced (DCE) MR Multitasking.
-
3. From Breath-Hold to Free-Breathing: Possibilities in High-Resolution Quantitative Susceptibility Mapping (QSM) of the Kidney With Respiratory Gating.
PMID:日期:2026-10-02This study aimed to assess the feasibility of QSM in the human kidney during free-breathing using respiratory gating for motion compensation. Renal imaging of 15 healthy volunteers was performed using an axial multi-echo GRE sequence on a 3 T MRI scanner. Each subject was scanned once during breath-hold and once during free-breathing with respiratory gating based on a respiratory cushion. Five subjects were repositioned and scanned again to test for reproducibility. Additionally, one subject was measured in axial and coronal direction maximizing the feasible resolution during free-breathing. All phase data was unwrapped, the background field removed, and the inverse problem solved to create susceptibility maps. For statistical analysis, the mean susceptibility values of one kidney were analyzed across three consecutive slices and referenced to the susceptibility of the paravertebral muscle. The investigation revealed no statistically significant differences between the breath-hold and respiratory gated sequence. The mean susceptibility values recorded in the right kidney were for the breath-hold and for the free-breathing. Bland-Altman analysis demonstrated good reproducibility for both methods. The high-resolution measurements enabled by gated breathing showed renal detail previously unseen in QSM. Free-breathing QSM protocols in the human kidney using respiratory gating show equal susceptibility results compared to breath-hold acquisition while increasing clinical feasibility. A free-breathing protocol allows for the measurement of a larger subject pool and enables an increase in critical sequence parameters, such as echo-time and resolution. This could improve the accuracy of susceptibility calculations in the human abdomen.
-
4. {"_":"Self-Correction of B Drift and Trajectory Error in Alternating Unbalanced SSFP-FID and SSFP-ECHO (AUSFIDE)-Based 3D Transverse Relaxometry of the Human Brain.","sub":["0"]}
PMID:日期:2026-10-02The alternating unbalanced SSFP (AUSFIDE) pulse sequence, which consists of multi-echo trains of SSFP-FID and SSFP-ECHO modules, enables rapid estimation of R and R', but is prone to errors from temporal drift of the main magnetic field (B) and k-space trajectory mismatch. Here, we propose a self-correcting AUSFIDE method for joint correction of these two sources of error without requiring additional scans. AUSFIDE signals were modeled in the presence of B drift and k-space shifts. To estimate and correct for B drift over the entire scan, phase navigators without spatial encoding were inserted before and after each multi-echo train. In addition, the intrinsic phase symmetry between SSFP-FID and SSFP-ECHO signals was exploited, enabling self-calibration of the k-space sampling trajectory. Numerical simulations and phantom experiments were performed for proof-of-concept validation, followed by in vivo brain imaging of 10 healthy subjects on two 3 T scanners. Measured parameters were analyzed in six brain regions, and test-retest reproducibility was evaluated on the two MRI platforms. Simulations and phantom imaging consistently demonstrated that B drift and trajectory errors resulted in image distortions and heavily overestimated R'. Experiments further revealed that these artifacts and quantification errors were substantially reduced by the proposed self-correction method. Inter-scan agreement of the quantified parameters was also improved after correction on both scanners. The self-corrected AUSFIDE method is able to compensate for errors from B drift and k-space trajectory mismatch, and thus is a potentially practical and reliable means for 3D transverse relaxometry.
-
5. An Adaptive Metasurface for Adjustable Magnetic Resonance Imaging Enhancement at 3 T and 7 T: A Feasibility Study.
PMID:日期:2026-10-02Ultra-high field (≥ 7 T) and 3 T MRI suffer from B inhomogeneity and signal loss. Conventional metasurfaces that mitigate B inhomogeneity and improve image SNR are "fixed" in nature and designed for a single Larmor frequency. This study demonstrates the feasibility of an adaptive metasurface utilizing voltage-controlled capacitors to dynamically adjust electromagnetic properties for adjustable image enhancement at both 3 T and 7 T H Larmor frequencies. A 3 × 3 unit-cell prototype was developed using voltage adjustable capacitors (33.0-16.5 pF) controlled by a 0-3 V DC source. Bench characterization and numerical simulations were performed to evaluate frequency characteristics and B distributions. Empirical data was acquired via GRE imaging and B mapping on 3 T and 7 T scanners. Multiple devices were also evaluated in tandem at 7 T to assess interference and spatial degrees of freedom. Simulations and phantom imaging confirmed voltage-dependent behavior. At 7 T, decreasing capacitance to 16.5 pF (3 V) yielded a 4.30× local SNR increase and a 60.0% boost in transmit efficiency. At 3 T, maximum enhancement (1.65× local SNR) occurred at 33.0 pF (0 V), demonstrating the ability of the device to adjust the optimal impedance between 128 and 300 MHz. Multiple metasurfaces successfully operated simultaneously without mutual interference, enabling multiregion enhancement. This work establishes the feasibility of an adaptive, low-power metasurface for remote subject-specific image enhancement. While the current enhancement was limited by the prototype's small size and capacitance range, the design provides a scalable foundation for future design iterations adaptable across different field strengths and potentially for multiple nuclei.
-
6. Cross-Platform Demonstration of an Autonomous MRI Field Camera.
PMID:日期:2026-10-02Recent work has proposed self-synchronization, self-calibration, and means of sequence parsing to enhance the versatility of field cameras. The purpose of this paper is to expand this approach to more complex sequences and verify feasibility across distinct scanner platforms. A field camera was formed from six field probes in a rigid-body arrangement and deployed in two commercial MRI scanners. Epoch folding for synchronization and the formation of sequence diagrams were expanded to nested sequences. Autonomous camera operation was used to record advanced sequences involving gradient-echo trains, spin-echo trains, and diffusion-tensor encoding. Autonomous camera operation was successful in both scanners, yielding sequence diagrams for all sequences explored. Autonomy of field cameras permits use across different MRI systems and degrees of sequence complexity. Potential applications range from method development and validation to sequence harmonization, multi-center studies, and quality assurance.
-
7. Optimization of Gradient Pulse Shape Prediction Using Temporal Convolutional Networks.
PMID:日期:2026-10-02To improve TCN-based gradient-waveform prediction with respect to acquisition efficiency and inference speed, and to evaluate its use for radial imaging. Gradient waveforms were measured using a thin-slice method on a preclinical MRI system. Separate TCN models were trained for each physical gradient axis to predict both gradient and terms. The framework was evaluated using phantom and in vivo radial acquisitions across a range of receiver bandwidths and compared with measured trajectories and gradient impulse response function (GIRF)-based trajectory predictions. The proposed workflow reduced model complexity and substantially improved prediction speed. In phantom and in vivo radial imaging, model-based trajectories provided better image quality over a wider range of receiver bandwidths than GIRF-based trajectories. term estimation provided limited additional visual benefit after scanner preemphasis adjustment. TCN-based prediction of gradient-waveform distortions can be made more efficient while remaining effective for radial MRI trajectory estimation on the studied preclinical system, particularly in demanding high-bandwidth acquisitions.
-
8. Optimized Gradient Waveforms for Tensor-Valued Diffusion MRI Under Time-Dependent Diffusion Using Double-Isotropic Matched Encoding (DIME).
PMID:日期:2026-09-24Spherical and linear b-tensor encoding (STE and LTE) enables quantification of microscopic diffusion anisotropy and diffusional variance. However, such waveforms are often variably sensitive to time-dependent diffusion, causing rotational variance and spectral mismatch. We propose double-isotropic matched encoding (DIME), which enforces isotropy in diffusion- and restriction-weighting tensors ( and ) and STE/LTE pairs matched in restriction sensitivity. DIME uses trapezoidal pulses, optimized to yield isotropic and while generating a spectrally matched LTE. The design ensures concomitant gradient balance and constrains peripheral and cardiac nerve stimulation. Rotational invariance and spectral matching were assessed by simulations in ideal and realistic substrates at 80 and 200 mT/m via CV across rotations and STE/LTE mean diffusivity (MD). DIME was compared to numerically optimized waveforms (NOWs). DIME had the lowest rotational variance and best spectral matching. In cylinders, the median (IQR) CV was 2.0% (1.5%-3.3%) and 1.7% (1.2%-2.7%) at 80 and 200 mT/m, versus 2.5% (1.8%-4.1%) and 2.0% (1.4%-3.5%) for NOW. In spheres, the maximum MD mismatch ( MD) was 0.08 versus for NOW. In realistic substrates, DIME was superior ( MD = ) compared to NOW ( ). DIME increased encoding duration by 13-22 ms. By controlling both and , DIME improves STE rotational invariance and reduces spectral mismatch under time-dependent diffusion, enabling more reliable tensor-valued encoding tailored to hardware and nerve stimulation constraints.
-
9. Strain Rate Angle Distribution as an Indicator of Post-Infarct Myocardial Remodeling: Proof-of-Concept of a Novel Application of the MRI Derived Strain Rate Tensor Field.
PMID:日期:2026-09-24Left ventricular (LV) strain is an early indicator of myocardial dysfunction. However, conventional strain metrics do not fully account for the multidirectional nature of myocardial deformation. The strain rate tensor, derived from velocity-encoded MRI, represents the time-resolved magnitude and direction of strain rate without the geometrical limitations of conventional methods. The purpose of this study was to demonstrate practical uses of strain rate tensor imaging for in vivo assessment of LV remodeling in a rat model of myocardial infarction (MI). A post-processing framework was developed to convert tissue phase mapping (TPM) MRI velocity data into strain rate tensor fields. TPM was performed at 1, 3, 10, ≈21, and ≈42 days post-MI in six rats. Six sham-operated rats served as controls. Global and regional strain rate and strain, as well as the strain rate angle distribution, were assessed. The dispersion in systolic and early diastolic strain rate angles was approximately 50% higher in MI hearts compared with sham (p = 0.001 and p = 0.014). Increased dispersion showed intra-individual correlation with decreased circumferential and radial strain rate magnitude in early diastole (p = 0.010 and p = 0.005). Global and regional strain rate and strain measurements were comparable with literature. Inter-study variability of the method was assessed and reported. Strain rate tensor field imaging based on TPM MRI can be utilized to quantify myocardial dysfunction in vivo. Analysis of strain rate angle dispersion indicates that the loss of uniformity in the direction of deformation is a key component of reduced myocardial contractility after remodeling.
-
10. Optimal Transmission Performance of Quadrature Wireless Resonators at 3 T.
PMID:日期:2026-09-24To demonstrate a method for optimizing the efficiency of wireless resonators using tailored excitation from a dual-transmit birdcage coil (BC), and to present the design and experimental investigation of a quadrature resonator for 3 T breast MRI application. A double-mode quadrature resonator was designed to enhance both orthogonal components of the field in a 3 T BC. Flip-angle maps measurements were performed on phantom to validate the predicted transmit efficiency gains. Numerical simulations were performed on a human voxel model to demonstrate the ability to optimize the field and SAR metrics. Experiments confirmed that each linear polarization was enhanced by the resonator, yielding a 4.5-fold improvement in the transmit efficiency compared with the reference BC under conventional circularly polarized (CP) excitation. The optimal excitation was derived and validated experimentally, leading to an additional 2% increase in transmit efficiency. Simulations revealed that the resonator provided a 5.9-fold (left breast) and 5.2-fold (right breast) improvement in SAR efficiency under conventional CP excitation. Tailored excitations further increased SAR efficiency by 15% (left breast) and 31% (right breast), approaching a 7-fold improvement compared to the reference BC. A double-mode quadrature resonator was demonstrated for 3 T MRI. Combined with dual-transmit BC, it enabled focusing and significantly improved transmit and SAR efficiency. Our analytical model allowed the derivation of tailored BC excitation to approach the theoretical performance limit of wireless resonators.