PHYSICS IN MEDICINE AND BIOLOGY医学与生物学中的物理学
PHYSICS IN MEDICINE AND BIOLOGY(英文缩写 PHYS MED BIOL),ISSN 0031-9155,eISSN 1361-6560,中文译名:医学与生物学中的物理学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.174 | Q2 |
| 2022 | 3.500 | Q2 |
| 2023 | 3.300 | Q1 |
| 2024 | 3.400 | Q1 |
| 2025 | 3.100 | Q2 |
PHYSICS IN MEDICINE AND BIOLOGY 最新收录文献
-
1. GeoCM-Pose: geometry-aware monocular dental 2D/3D registration benchmarked against reference-assisted methods.
1. GeoCM-Pose:几何感知的单眼牙科2D/3D配准,以参考辅助方法为基准进行评测PMID:日期:2026-10-05To develop GeoCM-Pose, a geometry-aware monocular dental 2D/3D registration method that predicts metric model-to-camera 6DoF pose from one image under weak texture, repetitive anatomy and partial visibility.GeoCM-Pose comprises cross-modal adaptation (CMA) and geometry-aware pose regression (GAPR). CMA uses fixed-Gaussian frequency separation and a high-frequency structure-preservation module with multi-scale edge extraction, spatial-channel gating and cross-resolution refinement. GAPR uses a ResNet-50/U-Net to predict dense object-coordinate maps; hierarchical geometric feature aggregation and geometry-aware channel refinement feed decoupled unit-quaternion and translation heads. Joint 20-point pose-matching and dense-coordinate losses train the network. The study comprised 30training cases, fivevalidation cases, fiveinternal-test cases, 10 fully held-out Teeth3DS+ dental surface models and a 200-frame benchmark generated from a single three-dimensional dental model.GAPR/V0 generated pose estimates for all 200 query frames, with median reprojection, rotation and translation-vector errors of 2.156 px, 1.252° and 0.653 mm, respectively, and a <5 px pass rate of 91.5% across all attempts. It used no inference-time reference-image bank. At R01, scale-invariant feature transform and ORB generated 85/200 and 89/200 valid estimates, with <5 px all-attempt pass rates of 40.5% and 40.0%; at R20, each generated 197/200 valid estimates, with pass rates of 98.0% and 95.5%. Thus, conventional performance increased with the available reference bank, whereas GAPR/V0 provided complete query coverage from a single image without inference-time reference images. Median GAPR/V0 inference latency, including image I/O, was 11.459 ms.GeoCM-Pose integrates CMA, dense object-coordinate supervision and metric pose regression for monocular dental 2D/3D registration. Further case-level evaluation using intraoral endoscopic images acquired from independent patient cases and additional image domains, together with robot-integrated experiments, is required to assess generalisation and system-level performance.
-
2. {"_":"modelling of radiobiological effects using tumor spheroids.","i":["In Silico"]}
PMID:日期:2026-10-02Radiotherapy remains one of the most widely used cancer treatments. However, optimizing its effectiveness requires a deeper understanding of the tumor architecture and its influence on radiation response. Three-dimensional spheroid cultures offer a more physiologically relevant model than traditional 2D assays, and their integration with in silico techniques enable the simulation of both growth dynamics and radiobiological response across multiple scales. In this study, we developed a multi-scale in silico framework capable of simulating tumor spheroid growth, using a Cellular Potts Model, and transferring that information to OpenTOPAS to simulate irradiation with any given particle type. The dose deposited at each cell was used to determine cell fate via a Two-Lesion Kinetic Model (TLKM), which accounts for cellular oxygen concentration, the number of radiation-induced double-strand breaks, their type (simple or complex), and their origin (direct or indirect). The model was applied to two rectal cancer cell lines (SW837 and SW1463) subjected to a short-course radiotherapy regimen of 5 Gy/fraction over 5 consecutive days, mimicking the treatment protocol used in rectal cancer patients. The model successfully captured key biological phenomena, including reoxygenation of hypoxic cells following each fraction and the persistence of necrotic cells due to limited clearance mechanisms. To our knowledge, this is also the first practical application of the oxygen fixation parameter within the TLKM. This framework provides a flexible platform for investigating alternative treatment regimens, combination therapies, and particle-based modalities. Expanding the experimental dataset, particularly with spatially resolved measurements of proliferative, hypoxic, and necrotic zones, will be essential to further constrain and validate the model. Incorporating subcellular damage mechanisms and explicit dose-rate effects into the TLKM formulation represents key directions for future development.
-
3. Radiolytic yields and peroxyl-radical kinetics predict the LET and oxygenation dependence of FLASH radiotherapy normal-tissue sparing.
3. 放射分解产额和过氧自由基动力学预测了FLASH放疗正常组织保护中的LET和氧合依赖性PMID:日期:2026-10-02FLASH radiotherapy spares normal tissue at ultra-high dose rates, but the dependence of this protection on linear energy transfer (LET) and tissue oxygenation is not mechanistically understood. We developed a model coupling Geant4-DNA track-structure G-values to the Labarbe peroxyl-radical (ROO•) kinetic framework to predict FLASH normal-tissue sparing as a joint function of LET and oxygenation.

Approach. G-values for •OH, e⁻aq, H• and H₂O₂ were computed with Geant4-DNA chem6 for electrons (0.16-8.70 keV µm⁻¹) and protons (0.69-9.5 keV µm⁻¹), with 500 primary events per LET point, and taken from published Monte Carlo data for carbon ions (10-200 keV µm⁻¹). These were supplied to the Labarbe ordinary differential equation system using the published rate constants without adjustment, and integrated across dose rates of 0.03-10⁵ Gy s⁻¹, doses of 5-30 Gy and oxygen concentrations of 2-200 µM. FLASH sparing was quantified as the fractional reduction in time-integrated ROO• exposure. The mechanism was tested by removing individual reactions from the kinetic system, and predictions were compared with three independent preclinical datasets.

Main results. Using the NTCP parameters published by Labarbe et al (2020), with no quantity fitted in the present work, the model gives a dose-modifying factor of 1.42; with the parameters refitted here it gives 1.44, against experimentally reported values of 1.30-1.40. Sparing decreases monotonically with LET, from 32.3% at 0.16 keV µm⁻¹ to 11.2% at 200 keV µm⁻¹. At matched LET, proton and electron yields converge below 2 keV µm⁻¹ but diverge by up to 19% in G(e⁻aq) at 8.7 keV µm⁻¹, setting a validity limit on LET-only parameterisation. Removing the ROO•-ROO• recombination term collapses sparing from 32.3% to 2.4%, identifying second-order peroxyl recombination as the operative mechanism. The oxygen dependence is dose- and dose-rate-gated, with the sparing difference across 2-200 µM ranging from below 1 to approximately 40 percentage points; at 30 Gy and 100 Gy s⁻¹ the model predicts 8.2 percentage points less sparing in bone osteocytes (15 µM) than in normoxic tissue, consistent with the absence of FLASH bone sparing reported in canine mandible.

Significance. Peroxyl-radical bimolecular recombination, driven by LET-dependent track-structure yields, provides a parameter-free chemical basis for the modality dependence of the FLASH effect. The predicted dose-, dose-rate- and oxygen-gating of sparing gives testable criteria for where FLASH protection should and should not occur.
-
4. Impact of depth-of-interaction and spatially-variant point-spread-function model on the performance of ultra-high resolution brain PET.
PMID:日期:2026-10-02To implement a spatially-variant point spread function (VarPSF) model for the NeuroEXPLORER (NX) brain positron emission tomography (PET) scanner in the open-source Yale Reconstruction Toolkit for PET (YRT-PET), and investigate the interplay between depth-of-interaction (DOI) resolution and resolution modeling.
Approach. PSF parameters were estimated from simulated and physically measured point sources. Three primary DOI configurations were evaluated: eight-layer DOI (8DOI), two-layer DOI (2DOI), and no DOI (noDOI), with an additional 4DOI comparison in the off-center simulated Derenzo study. Reconstructions using VarPSF, a spatially-invariant PSF measured at the field-of-view (FOV) center (SinglePSF), and no PSF modeling (noPSF) were assessed using simulated Derenzo and brain phantoms, a physical Derenzo phantom, and one non-human primate (NHP) scan.
Main results. In simulated and physical Derenzo studies, VarPSF yielded higher peak-to-valley ratios (PVRs) than SinglePSF and noPSF at the final evaluated iterations, with pronounced gains at large radial offsets. In the simulated brain phantom, VarPSF reduced the estimated transverse blur by 0.3 mm relative to SinglePSF and 0.5 mm relative to noPSF in 2DOI, and by 0.6 mm and 0.8 mm, respectively, in noDOI. In the NHP study, VarPSF improved contrast and structural delineation with reduced DOI encoding at approximately matched white-matter coefficient of variation, while its incremental benefit over SinglePSF was small with 8DOI at clinically relevant iteration settings.
Significance. Spatially-variant PSF modeling can partially compensate for limited DOI information. The findings motivate combining modest DOI capability with accurate resolution modeling, while further validation is required for redesigned detectors and fully corrected acquisitions. The open-source implementation enables controlled investigation of the complementary roles of DOI encoding and resolution modeling.
-
5. {"_":"Humidity effects in GafChromicEBT4 films for postal audits: characterization, reversibility and exploration of correction methods.","sup":["TM"]}
5. 湿度对GafChromicEBT4胶片在邮寄审计中的影响:特性表征、可逆性及校正方法探索PMID:日期:2026-10-02No harmonized methodology exists that enables traceable reference dosimetry with EBT4-film. The influence of humidity on EBT4 films is often overlooked and currently under-documented. This study quantified humidity effects for postal-audit reference dosimetry and explored the feasibility of empirical correction methods.
Approach. EBT4 films mounted in slide-frames were stored in humidity-controlled environments between 0 %RH and 100 %RH and scanned using a slide-scanner. Optical density (OD) was evaluated as a function of dose and humidity. Humidity darkening, changes in dose response and post irradiation growth were quantified. A humidity response factor, HOD, was introduced to describe the humidity dependent changes in dose-response. Two film intrinsic proxies were evaluated as possible proxies for the film humidity state.
Main results. Humidity was shown to affect OD and the humidity response factor, HOD. If not accounted for, this can lead to significant dosimetric errors. Between 12 %RH and 68 %RH, HOD exhibited linear behaviour as did the two film intrinsic proxies. Both humidity darkening and HOD showed to be reversible within the experimental uncertainty after re-acclimatization at 56 %RH. Exposure to 0 %RH and 100 %RH resulted in behaviour outside the practical operating range. The use of 0-Gy control films substantially reduced humidity-dependent offsets. The film-intrinsic humidity proxies showed relationships with HOD within the present single-sheet experiment, but their practical use requires further validation across film-lots and scanners.
Significance. This study demonstrates that humidity is a relevant influence quantity for EBT4-based reference dosimetry and should be controlled during film transport and storage. For the VSL postal audit service, humidity is regulated using BOVEDA-49 packages and monitored during transport as a practical mitigation strategy. The proposed correction formalism provides a method to investigate humidity-response behaviour for a specific film-sheet and scanner combination but does not yet constitute a generally validated correction method.
-
6. Scatter-induced non-linear signal compression and SDNR loss in triple-energy photon-counting iodine imaging.
PMID:日期:2026-10-02Triple-energy x-ray imaging with photon-counting detectors (PCDs) enables material decomposition, but energy-dependent scatter introduces bin-specific distortions that propagate nonlinearly through triple-energy subtraction and degrade image quality. The purpose of this work is to quantify how bin-dependent scatter alters triple-energy iodine signal formation and to determine its impact on signal-difference-to-noise ratio (SDNR). Analytical expressions for iodine signal difference, noise, and SDNR were derived incorporating energy-bin-specific scatter fractions (SF) and their nonlinear coupling with iodine areal density. Measurements were performed using a CdTe-based PCD and an image-quality phantom, with scatter varied via field of view (FOV) and quantified using the air-gap method. SDNR was evaluated over iodine areal densities of 33-140 mg/cm², SF values of ~0.2-0.8, tube voltages of 60-100 kV, and phantom thicknesses of 10-20 cm. A physics-informed empirical model was fit to the data. Simulations including charge sharing and beam hardening were used to support interpretation. Scatter fractions differed across energy bins, with the lowest-energy bin exhibiting the highest SF. Increasing scatter introduced curvature in energy-bin iodine signals as a function of areal density. When combined through triple-energy subtraction, these unequal responses produced pronounced signal compression in the triple-energy image. The model accurately predicted energy-bin and combined signal differences (R{{}^2} > 0.92) but showed reduced agreement for SDNR (R{{}^2} = 0.82-0.94), reflecting additional coupling between signal, noise, and scatter in the triple-energy combination. SDNR degradation exceeded that expected from first-order scatter scaling: for 52 mg/cm² iodine, SDNR decreased by ~20% at SF ≈ 0.2 and ~70% at SF ≈ 0.8. Simulations reproduced both linear contrast loss and the additional nonlinear compression observed experimentally. Bin-dependent scatter induces nonlinear signal compression in triple-energy imaging that directly amplifies SDNR loss with increasing iodine thickness. Because this behavior arises from the structure of triple-energy subtraction, first-order scatter scaling systematically underestimates performance degradation.
-
7. DiscoTSNet: a phase-guided temporal-spatial network for discontinuous respiratory motion prediction.
PMID:日期:2026-10-01Respiratory motion introduces positional uncertainties in radiotherapy for thoracic and abdominal tumors, and system latencies between respiratory signal acquisition and
 beam adjustment further increase targeting errors. This study aims to develop a precise real-time prediction method for discontinuous respiratory motion under prolonged latency
 conditions.

 Approach. We propose DiscoTSNet, a phase-guided temporal-spatial network for discontinuous respiratory motion prediction. The model combines a Phase-Guided Respiratory Decomposition
 module for separating respiratory signals into aperiodic, inhalation, and exhalation components; a Disco2D mechanism for organizing historical sequences according to known system
 latency; and a Spatial Feature Extraction module for modeling relationships among the coordinate channels of the surface markers.

 Main results. DiscoTSNet was evaluated on a publicly available CyberKnife respiratory motion dataset and achieved the lowest mean absolute error (MAE) and mean squared error (MSE)
 and the highest coefficient of determination (R^2) and correlation coefficient (CORR) among the compared models across the evaluated latency conditions from 200 ms to 1000 ms. At
 1000 ms latency, its MAE, MSE, R^2, and CORR were 0.186, 0.107, 0.688, and 0.831, respectively.

 Significance. The proposed latency-guided discontinuous respiratory motion prediction method is tailored to radiotherapy motion compensation and has potential to improve real-time
 tumor tracking and enhance radiotherapy precision.
-
8. Efficient Chebyshev reconstruction for the anisotropic equilibrium model in magnetic particle imaging.
8. 磁粒子成像中各向异性平衡模型的高效切比雪夫重构PMID:日期:2026-10-01
Magnetic Particle Imaging (MPI) is a tomographic imaging modality capable of real-time, high-sensitivity mapping of superparamagnetic iron oxide nanoparticles. Model-based image reconstruction provides an alternative to conventional methods that rely on a measured system matrix, eliminating the need for laborious calibration measurements. Nevertheless, model-based approaches must account for the complexities of the imaging chain to maintain high image quality. This work investigates and accelerates an adapted direct Chebyshev reconstruction (DCR) method that accounts for the physical effect of magnetic nanoparticle anisotropy.
Approach:
The adapted DCR method employs weighted Chebyshev polynomials in the frequency domain and incorporates a spatially variant deconvolution step to compensate for magnetic anisotropy effects. The method is evaluated on five experimental phantoms and compared with model-based and measured system matrix reconstructions. In addition, an efficient approximation of the spatially variant deconvolution is introduced to reduce computational runtime and memory consumption while maintaining reconstruction accuracy. The proposed approach is further investigated on simulated three-dimensional data to assess its scalability to volumetric MPI.
Main results:
The adapted DCR method significantly improves reconstruction quality in real measurements and achieves image fidelity comparable to that of the measured system matrix reconstruction and superior to that of the model-based system matrix reconstruction. The proposed approximation of the spatially variant deconvolution preserves the reconstruction accuracy while reducing computational and memory requirements. Its computational complexity is reduced to $\mathcal{O}(N \log N)$. The method also successfully reconstructs simulated 3D data, demonstrating its applicability to volumetric MPI.
Significance:
The results demonstrate the potential of the adapted DCR approach to improve model-based MPI reconstruction while avoiding the need for a system matrix. The efficient deconvolution approximation makes the method particularly attractive for high-resolution and three-dimensional imaging by substantially improving its computational efficiency and scalability.
-
9. Ultrafast proton delivery with pin ridge filters (pRFs): repurposing single-energy delivery for motion management in proton therapy.
PMID:日期:2026-10-01Highly conformal proton stereotactic body radiation therapy (SBRT) remains vulnerable to respiratory interplay, and standard mitigation techniques are either patient-dependent or enlarge the irradiated volume. Long delivery times dominated by energy-layer switching (ELS) limit the use of breath-hold (BH). We propose using pin-ridge filters (pRF) to eliminate ELS, shorten beam-on time, and reduce margins. A monoenergetic pRF plan was constructed, with the highest clinical energy (Emax) obtained from the reference internal target volume (ITV)-based intensity modulated proton therapy (IMPT) plan. To avoid per-patient commissioning, we used a bank of pre-commissioned monoenergetic beams spanning 110-200 MeV. Each beam model enables the development of a gross tumor volume (GTV)-based downstream IMPT (IMPT-DS) plan (reduced margins in the BH setting). Next, a nested pencil-beam-direction (PBD) spot-reduction process iteratively removed low-weighted spots from each PBD and, finally, generated pRFs with coarser resolution using a single-energy. This method was validated on five liver and one lung SBRT cases (10 Gy ×5) by comparing the relative total volume receiving the prescription dose (conformity index CI(GTV+5mm) =VRx/VGTV+5mm) and the mean lung-GTV and liver-GTV doses between the conventional IMPT and pRF plans. Across five liver SBRT cases, the average CI(GTV+5mm) improves from 2.64 (IMPT) to 1.16 (IMPT-pRF). The reduced dose cloud results in ~26% reduction in Dmean to liver-GTV. The mean beam-on time per field dropped from 43.02 s (IMPT) to 7.14 s (IMPT-pRF), i.e., an average saving of 35.88 s per beam (83.4% shorter). Lung SBRT follows a similar trend for CI(GTV+5mm) (3.22 to 1.58), lung-GTV Dmean (10.3 to 6.9 Gy), and average beam-on time (decreased from 47.2 to 9.5s per beam). These dosimetric improvements are primarily due to change in the planning approach (free-breathing ITV to BH GTV), whereas the key contribution of the pRF is shortening of beam-on time, which makes BH delivery feasible and thereby allows this margin reduction. This proposed method significantly reduces delivery time and organ-at-risk dose. Future work should focus on planning quality assurance (QA) and clinical implementation in patients with limited breath-hold capacity.
-
10. Decay-time correction for dual-panel in-beam PET monitoring of carbon-ion SOBP irradiation.
PMID:日期:2026-10-01In-beam positron emission tomography (PET) is a promising technique for monitoring beam range and activity distribution in carbon-ion radiotherapy. However, spread-out Bragg peak (SOBP) delivery introduces a challenge because sequentially delivered energy layers experience different decay times in in-beam and off-beam PET acquisitions. This study developed a decay-time correction method to reduce temporal bias in measured PET activity distributions under SOBP irradiation.
Approach: A dual-panel LYSO-SiPM PET system in a 4 × 1 module arrangement, with an effective detection area of 21.28 × 5.32 cm², was used to acquire in-beam and off-beam PET images during homogeneous solid-water phantom irradiation. The beam was delivered in scanning mode using sequential high-to-low energy layers, with up to 11 layers ranging from 216.50 to 263.23 MeV/u. Four irradiation schemes were evaluated: physical-dose, RBE-weighted dose (RWD), full-opposing-field RWD, and half-opposing-field RWD SOBP. A Monte Carlo-based decay-time correction framework was established by incorporating beam delivery timing, radionuclide decay characteristics, and activity accumulation. Corrected PET images were compared with Monte Carlo-simulated activity distributions generated using a platform consistent with the experimental setup.
Main Results: Sequential energy-layer delivery and radionuclide decay affected measured PET activity distributions under SOBP irradiation. After correction, experimental PET profiles showed improved agreement with corresponding Monte Carlo profiles across all four SOBP schemes. Depending on the irradiation scheme and acquisition mode, the correction reduced root-mean-square error by approximately 7.7%-53.7%, reduced SOBP-region mean absolute deviation by approximately 20.8%-71.4%, and increased the Pearson correlation coefficient from 0.860-0.973 before correction to 0.941-0.978 after correction.
Significance: This study addressed temporal bias in PET activity distributions caused by decay-time differences among sequentially delivered energy layers during carbon-ion SOBP irradiation. The proposed correction improved the reliability and interpretability of dual-panel in-beam PET under sequential multi-energy carbon-ion irradiation, extending planar PET monitoring toward more treatment-relevant verification scenarios.