ANALYTICAL BIOCHEMISTRY分析生物化学
ANALYTICAL BIOCHEMISTRY(英文缩写 ANAL BIOCHEM),ISSN 0003-2697,eISSN 1096-0309,中文译名:分析生物化学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 3.191 | Q3 |
| 2022 | 2.900 | Q2 |
| 2023 | 2.600 | Q2 |
| 2024 | 2.500 | Q3 |
| 2025 | 3.100 | Q2 |
ANALYTICAL BIOCHEMISTRY 最新收录文献
-
1. Iron Oxide-GO Nanocomposite to develop a High-Performance Electrochemical Sensor for Simultaneous Detection of Drugs.
PMID:日期:2026-10-04In this study, iron oxide nanoparticles were synthesized through a simple, cost-effective, and environmentally friendly green synthesis route using aqueous rose extract as a natural reducing and stabilizing agent. The synthesized nanoparticles were combined with graphene oxide (GO) and employed to modify a carbon paste electrode (CPE) for the simultaneous electrochemical detection of dopamine (DOP) and tryptophan (TRP). The fabricated FeO/FeO-GO/CPE sensor was characterized using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry. The modified electrode exhibited significantly enhanced electrocatalytic activity, sensitivity, and electron transfer capability compared with the bare electrode. Under optimized conditions, the sensor demonstrated wide linear dynamic ranges of 0.5-300 μM for dopamine and 1-300 μM for tryptophan, with low detection limits of 0.32 μM and 0.47 μM, respectively. The proposed sensor also showed excellent repeatability, good stability, high selectivity against common interfering species, and enhanced electroactive surface area due to the synergistic effect of iron oxide nanoparticles and graphene oxide. These results indicate that the developed nanocomposite-modified electrode is a promising, sensitive, and low-cost electrochemical platform for the simultaneous determination of biologically important analytes in pharmaceutical and biomedical applications. Future studies may focus on applying the proposed sensor to real biological and pharmaceutical samples and further improving its performance for portable and point-of-care electrochemical sensing applications.
-
2. Carboxymethylated Laminarin-Decorated ZIF-8 Enables Macrophage-Targeted Quercetin Delivery with Superior Anti-Inflammatory Efficacy.
2. 羧甲基化昆布多糖修饰的ZIF-8实现巨噬细胞靶向槲皮素递送,具有优越的抗炎功效PMID:日期:2026-10-03To address the limitations of quercetin (Qu), including low bioavailability, limited targeting, and insufficient synergistic enhancement, we developed a ZIF-8-based nanodelivery system (Qu-ZIF-8-CMLA) coated with a carboxymethyl laminarin (CMLA) layer. The platform was designed for macrophage-targeted delivery with potential for oral administration. Qu-ZIF-8-CMLA exhibited a hydrodynamic diameter of 151.5 nm, a drug loading capacity of 15.2%, and colloidal stability. Characterization confirmed CMLA coating of the Qu-ZIF-8 surface through electrostatic interactions and hydrogen bonding. The resulting nanoparticles maintained structural integrity and exhibited pH-responsive, controlled-release properties. In simulated gastric fluid, Qu-ZIF-8-CMLA released 23.54% of the Qu, whereas release reached 70.08% under simulated intestinal conditions, indicating a more sustained release profile than free Qu. Release kinetic analysis suggested a non-Fickian mechanism involving polysaccharide erosion and drug diffusion. In RAW264.7 macrophages, CMLA modification increased uptake by 6.35-fold, while competitive inhibition with free CMLA significantly attenuated this enhancement, supporting the involvement of CMLA-sensitive receptor-associated recognition in macrophage uptake. At high concentrations, Qu-ZIF-8-CMLA maintained higher RAW264.7 cell viability than Qu-ZIF-8 under the tested conditions. Anti-inflammatory activity was evaluated in LPS-stimulated RAW264.7 macrophages by measuring TNF-α, IL-1β, and IL-6 secretion using ELISA. Qu-ZIF-8-CMLA significantly reduced three pro-inflammatory cytokines compared with the LPS model group, and no statistically significant differences were detected between the Qu-ZIF-8-CMLA and untreated control groups (p > 0.05). Qu-ZIF-8-CMLA showed significantly greater anti-inflammatory activity than free Qu and Qu-ZIF-8. Collectively, these findings provide in vitro proof of concept for CMLA-modified, macrophage-targeted Qu delivery and support further investigation of this platform for oral anti-inflammatory applications.
-
3. Adaptation of a synthesis method for acetyl phosphate to related substrates.
3. 将乙酰磷酸的合成方法应用于相关底物PMID:日期:2026-09-30Acyl phosphate substrate availability is critical for applicable biochemical studies. Accordingly, various synthesis methods have been developed over the years typically focused on acetyl phosphate. One of these synthesis methods was proven versatile, capable of producing assorted primary and secondary acyl phosphates with high purity as measured by NMR spectroscopy, total carbon analysis and hydroxamate assays. Biochemical activity assays using synthesized acyl phosphate substrates generate results consistent with previously published kinetic constant data for Methanosarcina thermophila acetate kinase, while kinetic constant results for new substrates are reported for both M. thermophila acetate kinase and Desulfovibrio vulgaris str. Hildenborough butyrate kinase.
-
4. GOx@ZIF-90@CuCo-MOF paper-based nanozyme sensor for rapid and noninvasive glucose detection in saliva.
4. GOx@ZIF-90@CuCo-MOF纸基纳米酶传感器用于唾液中葡萄糖的快速无创检测PMID:日期:2026-09-30Glucose biosensors are pivotal to diabetes management; however, traditional fingerstick blood collection methods are often challenging due to their invasiveness, pain, high cost, and inability to provide continuous monitoring. Here, we constructed a paper-based colorimetric sensing platform using a multifunctional metal-organic framework (MOF) composite system to enable rapid, noninvasive detection of glucose in saliva. This platform utilized a CuCo-MOF framework, loaded with glucose oxidase (GOx) and ZIF-90 via a synergistic self-assembly mechanism, to catalyze the colorimetric reaction of HO and tetramethylbenzidine (TMB). The synergistic effect of the composite significantly enhanced the overall catalytic efficiency, enabling a sensitive response to glucose levels in saliva. Using ImageJ, color images captured with a smartphone were analyzed using RGB color channels to quantitatively determine glucose levels in saliva. The detection time was 20 min, with a detection limit (LOD) of 13.5 μM and a linear range of 50-2000 μM. This platform offered advantages with the absence of blood sample collection, ease of operation, and visual response. It provided new material strategies and design ideas for developing portable, non-invasive blood glucose monitoring technology.
-
6. CRISPR-dCas13a-based electrochemical biosensor for sensitive detection of miR-331-5p as a potential biomarker of Parkinson's disease.
PMID:日期:2026-09-26This study aimed to develop a CRISPR-dCas13a-based electrochemical biosensor as a proof-of-concept analytical platform for the sensitive and selective detection of miR-331-5p, which has been reported to be associated with Parkinson's disease. The biosensor was prepared by sequentially forming a self-assembled monolayer with 11-mercaptoundecanoic acid (MUA) on a gold electrode, functionalizing the surface with a generation-4 polyamidoamine (PAMAM-G4) dendrimer, immobilizing dCas13a, and assembling the target-specific sgRNA recognition complex. The electrode-modification steps were evaluated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). The impedance response increased linearly with miR-331-5p concentration over the experimentally evaluated range of 5-400 pM. The limit of detection and limit of quantification were 7.82 and 23.71 pM, respectively. Responses to the non-target miRNAs miR-146a-5p, miR-19 b-3p, miR-24-3p, and miR-7-5p were substantially lower than the response to miR-331-5p. Triplicate spike-recovery measurements in healthy human serum and storage-stability studies supported the analytical applicability and reproducibility of the platform. These findings demonstrate a CRISPR-dCas13a/EIS-based proof-of-concept analytical platform for miR-331-5p detection. Validation in well-characterized clinical cohorts will be required before any diagnostic application can be established.
-
7. Fe-Co bimetallic nanozyme-amplified lateral-flow immunoassay for the sensitive detection of porcine rotavirus.
7. 铁-钴双金属纳米酶增强侧向层析免疫分析法用于猪轮状病毒的灵敏检测PMID:日期:2026-09-17Porcine rotavirus (PoRV) causes severe viral diarrhea in piglets. Owing to the lack of specific antiviral therapies, rapid on-site detection is urgently required for swine disease control. Herein, a lateral-flow immunoassay (LFIA) amplified by Fe-Co bimetallic nanozyme was established for PoRV detection using two screened high-affinity anti-PoRV monoclonal antibodies. The peroxidase-like catalytic activity of Fe-Co nanozyme was employed for signal amplification on the immunochromatographic strip. The limit of detection of this LFIA was 100 TCID/mL, which was two-fold more sensitive than conventional commercial colloidal-gold-based test strips. No cross-reactivity was observed against other common porcine pathogens, including porcine epidemic diarrhea virus (PEDV), porcine deltacoronavirus (PDCoV), porcine sapelovirus (PSV), transmissible gastroenteritis virus (TGEV), porcine parvovirus (PPV), porcine reproductive and respiratory syndrome virus (PRRSV), and porcine pseudorabies virus (PRV). The intra-batch and inter-batch coefficients of variation were both below 10%, demonstrating favorable repeatability. The strip remained stable for at least 9 months under 4°C and ambient-temperature storage. When evaluated with 72 clinical pig fecal samples using RT-qPCR as the reference, the LFIA showed a sensitivity of 95.45%, specificity of 100%, and a total agreement rate of 98.61%, with a kappa value of 0.97 (95% CI: 0.891-1.000), indicating excellent agreement between the two methods. This Fe-Co nanozyme-amplified LFIA possesses high sensitivity, outstanding specificity, reliable stability and easy-to-operate characteristics. It can be applied for on-site PoRV screening in pig farms and facilitates early epidemic intervention of PoRV-associated diarrhea.
-
8. Erratum to "Development and malidation of a mechanism-based Ba/F3-hGHR bioassay for the potency assessment of recombinant human growth hormone" [Anal. Biochem. 720 116237].
8. 对“用于重组人生长激素效价评估的基于机制的Ba/F3-hGHR生物分析方法的开发与验证”一文的勘误 [Anal. Biochem. 720 116237]PMID:日期:2026-09-17该文献暂无摘要。
-
9. Integrated sustainability evaluation of electrochemical quantification of flibanserin and caffeine in various matrices.
PMID:日期:2026-09-14Sustainable chemistry is increasingly used in pharmaceutical analysis to reduce environmental impact while improving laboratory personnel safety. This study describes the first sustainable electrochemical method for determining flibanserin (FLB) and caffeine (CAF) in various matrices, including bulk powder, pharmaceutical dosage form, and human plasma samples. FLB is used for the treatment of Hypoactive sexual desire disorder, while CAF may be co-administered with FLB as part of the therapeutic regimen, highlighting the need for reliable methods for their simultaneous determination. The experimental parameters were optimized using a zinc oxide nanoparticle polyethylene glycol -modified carbon paste electrode as working electrode at scan rate of 100 mV s, and Britton-Robinson buffer (pH 7) as the supporting electrolyte using square wave voltammetry. Both analytes showed linear responses from 5.00 × 10 M to 100.00 × 10 M. The limits of detection for FLB and CAF were 1.617 × 10 M and 1.265 × 10 M, respectively. The limits of quantification were 4.851 × 10 M for FLB and 3.795 × 10 M for CAF. The method demonstrated satisfactory analytical performance and was validated in accordance with ICH guidelines. Student's t-test and F-test showed no significant differences between the proposed and reported methods. Sustainability was comprehensively evaluated using the Carbon Footprint Reduction Index, Multi-Color Assessment Tool, Analytical Green Star Area, and Click Analytical Chemistry Index. Overall, the proposed method provides a rapid, sensitive, and sustainable alternative for the simultaneous determination of FLB and CAF.
-
10. A NanoBiT-based high-throughput assay system for monitoring osteoclast fusion.
10. 一种基于NanoBiT的用于监测破骨细胞融合的高通量检测系统PMID:日期:2026-09-11Osteoclast fusion is an essential step in the acquisition of bone-resorbing activity; however, the molecular mechanisms underlying this process remain incompletely understood. In this study, we developed a novel quantitative monitoring system for osteoclast fusion using NanoBiT, a split-luciferase technology. This system enabled sensitive detection of receptor activator of NF-κB ligand (RANKL)-dependent osteoclast fusion in RAW264 cells and bone marrow-derived macrophages, as well as interleukin-4 (IL-4)-induced foreign body giant cell fusion. The time-course analysis of luciferase activity during osteoclast differentiation was closely correlated with osteoclast fusion observed by conventional microscopic analysis. In addition, luciferase activity was inhibited by cyclosporin A in a dose-dependent manner and completely abolished by Dcstamp knockout, demonstrating its validity for chemical screening and for evaluating genes involved in osteoclast fusion. Using this platform, we screened approximately 2300 known bioactive compounds and identified THZ-P1-2, a phosphatidylinositol-5-phosphate 4-kinase type 2 inhibitor, and Brequinar, a dihydroorotate dehydrogenase inhibitor, as novel modulators of osteoclast fusion. Compared with fluorescence-based assays, this luminescence-based system minimizes false-positive signals caused by cellular or compound autofluorescence and provides superior sensitivity and quantifiability. Furthermore, the assay is rapid, simple, and highly compatible with high-throughput screening, making it a useful platform for studying osteoclast fusion and for screening compounds that modulate this process.