BIOELECTROMAGNETICS生物电磁学
BIOELECTROMAGNETICS(英文缩写 BIOELECTROMAGNETICS),ISSN 0197-8462,eISSN 1521-186X,中文译名:生物电磁学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.848 | Q3 |
| 2022 | 1.900 | Q3 |
| 2023 | 1.800 | Q3 |
| 2024 | 1.200 | Q3 |
| 2025 | 1.600 | Q3 |
BIOELECTROMAGNETICS 最新收录文献
-
1. The Effect of Pulsed Electromagnetic Field on Pain and Foot Function Index in Patients With Plantar Fasciitis.
1. 脉冲电磁场对足底筋膜炎患者疼痛和足部功能指数的影响PMID:日期:2026-09The plantar fascia is a thick band of connective tissue that originates from the heel, and its inflammation is the most common cause of heel pain in adults. The Pulsed Electromagnetic Field (PEMF) is a non-invasive modality in the field of physiotherapy. This study aimed to determine the effects of PEMF on pain scores and the Foot Function Index (FFI) in patients with plantar fasciitis (PF). In this clinical trial study, 40 patients with PF, aged between 20 and 68 years, were randomly assigned in a block design into two groups: the Conventional Physiotherapy (CP) group and the CP plus PEMF (CPP) group. The Numerical Pain Rating Scale (NPRS) and the FFI questionnaire were used to assess the pain score (morning and evening pain) and foot function, respectively. Assessments were conducted before the study, at the tenth session of the CP and CPP groups, and 4 weeks later. The study variables in both the CP and CPP groups changed significantly (p < 0.05). In comparing the results between the two groups, the reduction in evening pain scores in the CPP group was significant compared to the CP group (p < 0.05). In comparison, there was no significant difference in morning pain scores between the two groups. The FFI score in the CPP group significantly decreased compared to the CP group. Both CP and CPP are effective in reducing pain and the FFI in patients with PF. The addition of PEMF to CP demonstrates a more significant effect on reducing evening pain and somewhat on reducing the FFI in patients compared to CP alone. However, it did not have an additional effect on reducing morning pain. Bioelectromagnetics. 00:00-00, 2026. © 2026 Bioelectromagnetics Society.
-
2. Evaluating Human Perception Thresholds in Magnetic Stimulation Using Experimental Measurements and Modelling.
PMID:日期:2026-07-27This preregistered study investigated whether induced electric fields alone could predict human perception thresholds in magnetic stimulation. Using a figure-of-eight magnetic coil placed on the forearm, perception thresholds were collected from 24 healthy participants using the method of adjustment in 12 stimulation conditions. Subject-fitted, anatomically realistic forearm models were constructed from a set of 10 MRI-based models. Induced electric fields were computed using the finite element method with probabilistic tissue conductivities and post-processed using spatial averaging and percentiles. Linear mixed-effects modelling showed that the perception threshold was 32.2 V/m (SD between subjects 5.2 V/m) for a damped sinusoidal magnetic pulse with 83 s phase duration. This threshold value was determined by spatial averaging over a cube with a side length of 2 mm and taking the 99th percentile of the electric field within the modelled forearms. However, the induced electric field did not fully explain the perception threshold (adjusted = 0.48; permutation testing, p 0.001). We also conducted a supplementary modelling study, retrospectively analysing previous literature results to allow for direct comparison with our findings. These results showed that simplified calculations of the threshold electric field, obtained by modelling the forearm as a uniform cylinder, need to be scaled by a factor of 1.4 to align with the 99th percentile electric field calculated with anatomically realistic models. Both our experimental results and the modelling provide data to inform the refinement of safety guidelines.
-
3. Effects of Pulsed Electromagnetic Field Application on Glucose Metabolism in Rats.
PMID:日期:2026-07-27The present study aimed to evaluate the effects of pulsed electromagnetic field (PEMF) exposure on glucose metabolism-related hormonal and oxidative stress markers. Twenty-three male Wistar albino rats were randomly assigned to three groups: sham-control (n = 7), PEMF (n = 8), and PEMF + vitamin C (n = 8). The PEMF and PEMF + vitamin C groups were exposed to a pulsed magnetic field at 50 Hz and 1.5 mT for 4 h daily over 4 weeks. Vitamin C (250 mg/kg/day) was administered orally to the PEMF + vitamin C group. Serum and tissue levels of insulin, glucagon, glucagon-like peptide-1 (GLP-1), sirtuin 1 (SIRT1), total antioxidant capacity (TAC), and total oxidant capacity (TOC) were measured. Histopathological evaluations of brain, liver, and pancreatic tissues were also performed. Serum glucose, insulin, glucagon, GLP-1, SIRT1, TAC, and TOC levels did not differ significantly among the experimental groups. Gastric TAC levels were significantly higher in the PEMF + vitamin C group. In renal tissue, insulin levels were significantly elevated only in the PEMF + vitamin C group. PEMF exposure did not induce systemic biochemical changes in healthy rats but elicited tissue-specific biochemical responses, particularly in gastric tissue. These findings suggest that PEMF may modulate glucose-related endocrine and redox pathways at the gastrointestinal level without causing structural tissue damage. Bioelectromagnetics. 00:00-00, 2026. © 2026 Bioelectromagnetics Society.
-
4. Correction to "A Ten-Country Study on Public Perceptions of 5G EMF Emissions: Who Feels Exposed, and Why?"
PMID:日期:2026-07该文献暂无摘要。
-
5. Computational Simulation and Experimental Validation of Electric Field Distribution Patterns in TTFields Therapy for Lung Cancer.
PMID:日期:2026-06-26Tumor treating fields (TTFields) is a non-invasive therapeutic technology that disrupts mitotic division via intermediate-frequency alternating electric fields. For non-small cell lung cancer (NSCLC) at 150 kHz, complex thoracic anatomy and heterogeneous tissue properties often hinder the attainment of the therapeutic threshold (≥ 1 V/cm). To overcome this, high-fidelity Duke (male) and Ella (female) anatomical models were employed for full-wave simulations. The coordinated deployment of orthogonal transducer arrays (AP-20, LR-20, LR-13) with sex-specific tuning substantially enhanced electric-field coverage in the lower and lateral lung regions. Furthermore, modifying lung dielectric parameters by 20% demonstrated that these configurations maintain stable therapeutic coverage, exhibiting robustness against potential physiological or pathological variations. To provide an experimental foundation, in vivo murine measurements were conducted. Rather than attempting to replicate deep spatial complexities of the human body, these experiments served as a translational bridge to validate macroscopic voltage transfer efficiency and system-level losses. By introducing a physically derived correction factor (Roi) to account for voltage delivery drops, statistical analyses confirmed a high agreement between simulated and in vivo datasets, verifying the reliability of the computational framework. Regarding safety, the computed electrode-skin current density remained strictly below 31 mA/cm, which, alongside built-in clinical hardware temperature limits, effectively mitigates the risk of thermal and stimulation-induced injuries. Ultimately, this optimized strategy provides a complementary, independent physical modality that integrates bioelectromagnetic modeling with preclinical validation, offering a reliable theoretical reference to facilitate individualized NSCLC treatment planning.
-
6. Effect of Magnetic Field on the Ability of Vibrational Iterations to Enhance ROS Production by Neutrophils.
PMID:日期:2026-06-26When studying high dilutions, we concluded that the main role in their activity is played by the vibrational effect accompanying the dilution of the initial substance during their preparation. This concept served as the basis for developing a novel "crossing" technology, in which the initial substance and a neutral carrier (water or lactose), placed in separate, closely spaced vials, are subjected to joint vibrational processing. Consequently, the neutral carrier acquires the capacity of exerting a modifying effect on the initial substance or its target, thereby altering its physicochemical and biological properties, with the resulting product termed a vibrational iteration. In this work, the influence of vibrational iterations obtained from a neutrophil suspension as the initial substance on reactive oxygen species (ROS) production by neutrophils was studied using a cellular chemiluminescence assay. The role of the magnetic characteristics of the fields under which the vibrational iterations were prepared was also investigated. It was shown that vibrational iterations prepared under geomagnetic field conditions exerted only a minor effect on ROS production by neutrophils. At the same time, vibrational iterations prepared under a combined magnetic field comparable to the geomagnetic background and supplemented with a low-amplitude variable component (50 nT with a frequency of 12.6 Hz) increased the ability of neutrophils to produce ROS by 44% ± 12%. These findings demonstrate the possibility of preparing vibrational iterations from various initial substances, including biological material. The modulating effect of combined magnetic fields on their activity was also demonstrated.
-
7. Measurements of Radio-Frequency Electromagnetic Field Levels in EXPO2025 Osaka, Kansai, Japan.
PMID:日期:2026-06-26In this study, we investigated radio‑frequency electromagnetic field (RF‑EMF) levels at the Expo 2025 Osaka, Kansai, Japan, a large‑scale international event that attracted approximately 26 million visitors during the event period. Spot and portable measurements were conducted for broadcast, 4G, 5G, and ISM bands in both indoor and outdoor environments. The observed E‑field strengths remained below the reference levels specified in the Japanese Radio Radiation Protection Guidelines, with the maximum E-field strength corresponding to 0.4% of the guideline limits. The RF‑EMF levels measured at the venue were comparable to those measured in typical urban areas and consistent with findings from similar studies conducted overseas. These results confirm that the level of RF‑EMF exposure during high‑density public events in Japan remains below regulatory limits and exhibits behavior trends similar to those observed in ordinary urban environments.
-
8. Monitoring Lipid Oxidation in Different Lipid Matrices by Dielectric Spectroscopy Using an Open-Ended Coaxial Probe.
PMID:日期:2026-06-15Lipids undergo oxidative degradation during storage, leading to quality deterioration and potential health risks; therefore, rapid and reliable monitoring methods are needed. This study evaluated dielectric measurements as an alternative approach to determine the oxidative status of different lipid systems (bulk oil, emulsion, and fatty acid methyl esters, FAMEs) during auto-oxidation. Samples were analyzed simultaneously by conventional chemical methods (peroxide value, p-anisidine value, and induction time) and microwave dielectric measurements in the 2-20 GHz frequency range using a coaxial probe. Strong correlations were observed between dielectric parameters and peroxide values as well as induction time in all lipid systems. Good correlations were also found between dielectric data and p-anisidine values in bulk oil and FAMEs, whereas correlations were moderate in emulsions. The results demonstrate that dielectric measurements show strong potential as a rapid, non-destructive, and environmentally friendly approach for assessing lipid oxidation.
-
9. Exposure to 5G Radiofrequency and Physiological Effects in Healthy Young Adults: Insights Into Heart Rate Variability and Salivary Stress Biomarkers.
PMID:日期:2026-06-05This study investigated the potential impact of fifth-generation (5 G) radiofrequency (RF) on the autonomic nervous system (ANS). Electrocardiograms (n = 43) and salivary samples (n = 33) were collected from healthy young volunteers before, during, and after exposure to a 3.5 GHz frequency (electrical field intensity ~1-2 V/m) emitted by an antenna while participants were seated at rest. Heart-rate (HR) and heart rate variability (HRV) indices, including time and frequency domain measures, were analyzed from short-term epochs during both "real" and "sham" exposure sessions, under eyes-open (EO) and eyes-closed (EC) conditions. Initial variations in RR intervals and HR were observed during 5 G exposure; however, these effects were not confirmed by post-hoc analyses after correction for multiple comparisons, suggesting the absence of consistent exposure-related modulation. The only statistically significant result was a time-by-exposure interaction for the RMSSD parameter during the final exposure period. This effect was small in magnitude, limited to a single time point, and not supported by other parasympathetic indices, and should therefore be interpreted cautiously as it may reflect normal physiological variability or a statistical artifact. No consistent exposure-related effects were detected in salivary stress biomarkers, including cortisol, alpha-amylase, and chromogranin A. Although minor variations were observed in some measures, all values remained within normal physiological ranges, and their clinical relevance remains uncertain. These findings are restricted to the specific experimental conditions examined, namely short-term far-field exposure (25.5 min) at low specific absorption rate (SAR) levels (0.008 mW/kg in the brain). Overall, the results provide preliminary baseline human data at 3.5 GHz rather than confirmatory evidence of biological effects. Further studies involving larger cohorts and longer exposure durations are required to determine whether subtle or cumulative autonomic effects of 5 G exposure can be reliably detected. Bioelectromagnetics. 00:00-00, 2026. © 2026 Bioelectromagnetics Society.
-
10. A Ten-Country Study on Public Perceptions of 5G EMF Emissions: Who Feels Exposed, and Why?
PMID:日期:2026-06-05Formal risk assessment considers characteristics such as proximity, dose, and vulnerability. However, public risk perception may also be influenced by other-possibly less relevant-factors such as visibility and novelty. The introduction of 5G and its associated infrastructure and radiofrequency electromagnetic fields (RF-EMF) may therefore change perceptions of RF-EMF from mobile communications in general. To explore this, we conducted an online survey in 10 European countries (n = 10,358) using a picture-based approach. Respondents perceived daily RF-EMF exposures as moderate but expected them to increase with 5G. A mobile phone at the ear was generally associated with higher perceived exposure than multiple base stations. Overall, distance to the RF-EMF source most strongly influenced perceived exposure, followed by the number of sources. 5G reception was linked to higher exposure perception than 4G or Wi-Fi reception. These patterns were consistent across most countries. We conclude that when assessing RF-EMF exposure, people rely on heuristics (e.g., more sources imply more exposure) that often guide them correctly. Understanding when and why people feel particularly exposed can help develop more effective communication about true levels of exposure and risk.