Computer Methods and Programs in Biomedicine计算机方法与程序在生物医学中的应用
Computer Methods and Programs in Biomedicine(英文缩写 COMPUT METH PROG BIO),ISSN 0169-2607,eISSN 1872-7565,中文译名:计算机方法与程序在生物医学中的应用 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 7.027 | Q1 |
| 2022 | 6.100 | Q1 |
| 2023 | 4.900 | Q1 |
| 2024 | 4.800 | Q1 |
| 2025 | 6.400 | Q1 |
Computer Methods and Programs in Biomedicine 最新收录文献
-
1. A radiomics-based machine learning framework for full-reference ultrasound image quality assessment across varying acquisition settings.
1. 一种基于影像组学的机器学习框架,用于在不同采集设置下进行全参考超声图像质量评估PMID:日期:2026-09-29Ultrasound image quality depends on acquisition conditions, while conventional full-reference image quality assessment (FR-IQA) metrics may not fully capture perceptually relevant intensity and texture changes. Radiomics has been explored for image-quality characterization in other medical modalities. This study developed a radiomics-based machine-learning framework for FR-IQA under controlled acquisition-setting variations. Rabbit cadaver ultrasound data included two anatomies and two probe-scanner configurations, defining four reference groups. Varying frequency, gain, power, and dynamic range yielded 192 reference-test pairs. Four sonographers rated pairs. B-mode and wavelet radiomic descriptors formed six full-reference representations evaluated by reference-grouped nested model development. Performance was compared with eight classical FR-IQA methods and two learned perceptual metrics, with robustness and acquisition-setting analyses. Average-measure inter-observer agreement was high, with ICC(A,k) = 0.9602. Out-of-reference predictions achieved SROCC = 0.8930, PLCC = 0.8702, RMSE = 0.1462, and R = 0.7196. On the primary region of interest (ROI), the framework showed higher observed aggregate performance than all classical FR-IQA methods, while learned perceptual metrics showed higher observed performance. No reference-aware pairwise comparison was significant after Holm correction. Predictions were stable under modest ROI and discretization perturbations. Gain had the largest median radiomic effect and was the dominant factor for subjective quality and predictions across reference groups, enabling feature- and prediction-level assessment of acquisition-setting sensitivity. Radiomic full-reference representations provide an interpretable approach for characterizing acquisition-dependent ultrasound image quality, with potential utility for system evaluation and protocol optimization. Larger multi-system, in vivo studies with repeated acquisitions and independently defined references are needed to establish generalizability.
-
2. A computational framework for EMG simulation and coherence-based biomarker analysis on neural crosstalk in bimanual coordination.
PMID:日期:2026-09-25This study presents a computationally and physiologically grounded framework for electromyography (EMG) simulation to examine how assumed cortical and subcortical inputs shape bilateral EMG and intermuscular coherence during bimanual coordination. Simulated first dorsal interosseous (FDI) EMG was generated for a 1:2 force coordination task (approximately 40% maximum voluntary contraction) using motor unit models incorporating (i) variable cortical and subcortical drive weighting, (ii) narrowband versus broadband cortical drive (13-30 vs. 13-60 Hz), and (iii) asymmetric bilateral coupling. Intermuscular EMG-EMG wavelet coherence was computed across α, β, low-γ, and high-γ bands. Model outputs were validated against experimental human EMG at the signal level, comparing simulated and recorded bipolar first dorsal interosseous traces across eight amplitude and frequency-domain signal features. Coherence magnitude increased with greater modeled neural crosstalk and cortical weighting. The frequency band most sensitive to drive weighting depended on cortical bandwidth: β-band coherence (13-30 Hz) best differentiated cortical and subcortical influences under narrowband drive, whereas low-γ (30-60 Hz) was most informative under broadband conditions. α-band coherence showed minimal sensitivity to subcortical modulation in this context. Within this simulation framework, intermuscular coherence was sensitive to modeled bilateral coupling and cortical-subcortical weighting, with diagnostic sensitivity depending on the spectral bandwidth of cortical drive. Thus, the model should be interpreted as a hypothesis generating, signal level framework rather than a direct neural measurement. This open-source framework bridges computational modeling and biomarker signal analysis, supporting reproducible, hypothesis driven biomarker development for neuromotor disorders such as Parkinson's disease, spinal cord injury, and stroke.
-
3. Microbubble dynamics simulation reveals the effects of microbubble distance from the clot on the outcome of sonothrombolysis.
PMID:日期:2026-09-23Sonothrombolysis employs ultrasound waves to induce inertial cavitation of microbubbles, generating high-speed microjets that mechanically erode blood clots. While clot lysis efficacy is closely linked to the proximity of microbubbles to the clot surface, experimental quantification remains challenging due to blood opacity and small timescales. This study utilises a computational modelling strategy to evaluate the impact of microbubble standoff distance (10-70μm) at ultrasound pressure amplitudes (600-1500 kPa) on sonothrombolysis efficacy, as quantified by flow-induced shear stress and drug penetration caused by microjet impingement. Results demonstrated that at long standoff distance of 50 and 70μm, sonothrombolysis efficacy deteriorated as microjets dissipated into the surrounding blood before clot impingement. Although increasing insonation pressure compensated for this loss, shear loading and drug penetration remained inferior to shorter standoff distances. A short standoff distance of 10μm produced the highest shear loading, while the maximum drug penetration was achieved at a moderate standoff distance of 30μm. These simulation results reveal that sonothrombolytic mechanisms can be selectively tuned by adjusting microbubble proximity, providing a quantitative framework for optimising sonothrombolysis protocols with either mechanical erosion or thrombolytic drug penetration.
-
4. SDFStent: Real-time interactive virtual stenting via SDF deformation fields.
PMID:日期:2026-09-21Stenting is among the most common transcatheter interventions for congenital heart disease (CHD). Patient-specific computational fluid dynamics (CFD) simulations can predict hemodynamic outcomes of intervention scenarios but require post-operative vascular geometries that reflect stent-induced shape changes, which existing tools either model inadequately or require extensive time or manual effort to generate. We present SDFStent, a signed distance function (SDF) based mesh deformation method for virtual stenting that operates in real time, maintains mesh integrity, and preserves junction geometry. The stent is modeled as a pipe surface composed of piecewise-capsule SDFs joined by a smooth-minimum operator. Mesh vertices near the expanding SDF surface are displaced along the SDF gradient with a compactly supported fall-off function and an alpha blending mask. SDFStent was benchmarked against three existing approaches and validated on a proof-of-concept cohort of three tetralogy of Fallot (ToF) and three coarctation of the aorta (CoA) patients using rigid-wall steady-state CFD simulations against clinical catheterization measurements. Against a prescribed diameter of 6.0 mm, the method produced a mean stented diameter of 5.92 ± 0.08 mm in 1.5 s, over 100× faster than the best stenting-specific comparator. All output meshes were watertight and self-intersection-free. CFD-simulated post-operative pressure drops agreed with clinical measurements within 4 mmHg (mean error 2 mmHg). SDFStent produces simulation-ready post-stent models that match prescribed stent dimensions at interactive speeds, from pre-operative anatomy and catheterization data alone. The implementation is open-source and available in 3D Slicer. Its scriptable architecture enables automated generation of large synthetic cohorts for data-driven surrogate modeling.
-
5. MTT assay analyzer: an open-source smartphone-based web application for semi-quantitative colorimetric analysis of 96-well plates.
PMID:日期:2026-09-20The MTT assay is usually used to evaluate cell viability and metabolic activity, typically quantified via spectrophotometric absorbance. Conventional plate readers are reliable but costly and inaccessible in many educational and resource-limited laboratories. Consumer smartphones offer a low-cost alternative, but existing methods require dedicated hardware or manual processing. MTT assay analyzer is an open-source, mobile-optimized web application for semi-quantitative analysis of MTT assay photographs taken with smartphones, tested on iPhone Air, processed directly in a standard browser without installation. The workflow includes manual alignment to two reference points, RGB colour sampling with spatial averaging, grayscale pseudo-absorbance estimation, and gamma-green channel corrected absorbance via power-law linearization. Optional 2-4-point linear calibration uses spectrophotometer references. Validation was performed in five independent experiments using Pearson correlation, Bland-Altman analysis, and root mean square error (RMSE) against a spectrophotometer. A total of 372 paired measurements were analysed across five independent experiments (absorbance range 0.01-1.78 AU). Across all experiments, the grayscale method with two-point calibration (GS + Cal) achieved the highest agreement with spectrophotometric reference values (pooled: r = 0.991, R² = 0.983, RMSE = 0.057 AU, 95% LoA [-0.124, +0.090]). The uncalibrated grayscale method showed systematic underestimation (pooled mean bias -0.052 AU), which was substantially reduced by calibration (mean bias -0.017 AU). Per-experiment RMSE for GS + Cal ranged from 0.035 to 0.078 AU. Pearson r ranged from 0.924 to 0.999 across all methods and experiments, with the lowest values observed in experiments with a restricted dynamic range (maximum absorbance ≤ 0.95 AU) rather than reflecting measurement failure. Two-point calibration reduced RMSE in all five experiments. MTT assay analyzer delivers a low-cost tool for smartphone-based semi-quantitative MTT analysis, ideal for trend detection, screening, and education where spectrophotometers are unavailable.
-
6. Flexible framework for generating synthetic electrocardiograms and photoplethysmograms using a parametrized model.
6. 使用参数化模型生成合成心电图和光电容积脉搏波的灵活框架PMID:日期:2026-09-19By generating synthetic biosignals, the quantity and variety of health data can be increased. This is especially useful when training machine learning models by enabling data augmentation and introduction of more physiologically plausible variation to the data. For these purposes, we have developed a synthetic biosignal model for two signal modalities, electrocardiography (ECG) and photoplethysmography (PPG). The model produces realistic signals that account for physiological effects such as respiratory modulation and changes in heart rate due to physical stress. Arrhythmic signals can be generated with beat intervals extracted from real measurements. The model also includes a flexible approach to adding different kinds of noise and signal artifacts. The noise is generated from power spectral densities extracted from both measured noisy signals and from modeled power spectra. Importantly, the model also automatically produces labels for noise, segmentation (e.g. P and T waves, QRS complex, for electrocardiograms), and artifacts. We assessed how this comprehensive model can be used in practice to improve the performance of models trained on ECG or PPG data. For example, we trained a convolutional neural network to detect ECG R-peaks using either real ECG signals or synthetic signals from our new generator. The F1 score of the peak detection was 0.87 using real data, in comparison to 0.98 using our generator. In addition, the synthetic biosignal model can be used for example in signal segmentation, quality detection and bench-marking detection algorithms. We developed a fully-annotated multi-modal framework for synthetic ECG and PPG generation. The code for the framework with a tutorial demonstrating its use has been released in https://github.com/UTU-Health-Research/framework_for_synthetic_biosignals.
-
7. A new computational phenotyping framework for the clinical characterization of pediatric celiac disease.
7. 用于儿童乳糜泻临床特征描述的新计算表型分析框架PMID:日期:2026-09-17Pediatric celiac disease (CD) is characterized by marked clinical and immunological heterogeneity that is not fully captured by the current symptom-based Oslo classification. Data-driven computational phenotyping may enable the identification of more homogeneous patient subgroups by integrating multimodal clinical information. This study proposes a topological data analysis (TDA)-based computational framework (pheTDA) to identify and characterize novel sub-phenotypes of pediatric CD from multicentric clinical data. A retrospective multicentric cohort of 2,922 pediatric CD patients described by 34 demographic, clinical, serological, genetic, and histological variables was analyzed. Mixed-type data were processed using Gower distance and mapped through a semi-supervised TDA Mapper pipeline, followed by Louvain community detection. The resulting communities were characterized through statistical testing and supervised machine learning. pheTDA was benchmarked against t-SNE followed by DBSCAN and agglomerative hierarchical clustering (AHC), and sensitivity analyses repeated pheTDA using clinical variables only and diagnostic-test variables only. pheTDA identified seven relatively balanced sub-phenotypes with distinct combinations of symptoms, serological profiles, histological damage, growth delay, and autoimmune comorbidities. Compared with pheTDA, DBSCAN generated a markedly imbalanced nine-cluster partition, whereas the four-cluster AHC solution was dominated by sex. pheTDA showed a clinically broader effect-size profile, with its leading discriminators spanning clinical, serological, genetic, and histological domains. Clinical-only pheTDA communities were strongly aligned with the symptom-based Oslo categories, whereas diagnostic-test-only communities were more fragmented and reflected specific test combinations. Random Forest classifiers achieved a higher mean AUC for pheTDA communities than for Oslo classes (0.94 vs. 0.88). Multimodal pheTDA provides an exploratory and reproducible framework for identifying clinically interpretable pediatric CD sub-phenotypes. Benchmarking and feature-domain sensitivity analyses support the value of integrating clinical and diagnostic information while emphasizing that the resulting communities are data-dependent computational representations rather than definitive disease classes.
-
8. Material characterization of heterogenous atherosclerotic arteries with the Virtual Fields Method.
8. 基于虚拟场法的异质性动脉粥样硬化动脉材料表征PMID:日期:2026-09-12[中文摘要] 动脉中动脉粥样硬化斑块的破裂是危及生命的心血管事件的主要原因。斑块破裂与斑块内机械应力升高密切相关。由于斑块具有多组分构成导致的结构异质性,对斑块进行应力分析在改进斑块破裂风险评估、指导临床决策和手术规划方面具有重要潜力。然而,一个主要挑战在于高效且准确地表征斑块特定的力学属性。在本研究中,我们引入了一种基于虚拟场方法(VFM)的新框架,用于识别动脉粥样硬化斑块的异质材料属性。我们进一步提出了一种系统性策略,用于生成适用于受压管状结构(如动脉这一特定应用)的虚拟位移场(VDFs),并确定来自超声测量数据的颈动脉斑块所需的最佳VDF数量。所提出的框架在估计单个斑块组分的力学属性方面实现了高精度,即使在考虑超声数据中现实水平噪声的情况下也是如此。计算时间在临床前超声分辨率下为11 ± 2.5 s,在临床超声分辨率下为8.6 ± 2.3 s。这项工作首次实现了将VFM用于异质动脉粥样硬化斑块的材料表征。该框架的鲁棒性和计算效率为未来面向在体斑块表征的研究提供了方法学基础。
[英文摘要] Rupture of an atherosclerotic plaque in an artery is the primary cause of life-threatening cardiovascular events. Plaque rupture is closely associated with elevated mechanical stresses within the plaque. Stress analysis of plaques, which are structurally heterogeneous due to their multi-component composition, holds significant potential to improve the rupture risk assessment of plaques, guiding clinical decision making and surgical planning. A major challenge, however, lies in the efficient and accurate characterization of plaque-specific mechanical properties. In this study, we introduce a novel framework based on the Virtual Fields Method (VFM) to identify the heterogeneous material properties of atherosclerotic plaques. We further propose a systematic strategy to generate virtual displacement fields (VDFs) tailored for pressurized tubular structures, such as the specific application of arteries, and determine the optimal number of VDFs for carotid artery plaques from ultrasound-derived measurements. The proposed framework achieved high accuracy in estimating the mechanical properties of individual plaque components, even when realistic levels of noise in the ultrasound data were considered. The computation time was 11 ± 2.5 s for pre-clinical ultrasound resolution and 8.6 ± 2.3 s for clinical ultrasound resolution. This work presents the first implementation of VFM for the material characterization of heterogeneous atherosclerotic plaques. The robustness and computational efficiency of the framework provide a methodological basis for future studies toward in vivo plaque characterization.
-
9. Computational screening of alginate biomaterials for intervertebral disc repair via agent-based simulation.
9. 基于智能体模拟的藻酸盐生物材料用于椎间盘修复的计算筛选PMID:日期:2026-09-10Low back pain, driven largely by intervertebral disc (IVD) degeneration within the central nucleus pulposus (NP) region, affects over 600 million people globally. Although hydrogels are promising biomaterials for NP repair, optimizing their interdependent design parameters through traditional experimentation is resource intensive. This study developed an IVD-hydrogel agent-based model (IVDH-ABM) for computational screening of alginate biomaterial formulations. The IVDH-ABM was implemented in C++ with OpenMP and CUDA. This lattice-based model simulated 27,000 NP cell agents at 10 µm spatial resolution, with local physical and chemical cues of proliferation, apoptosis, migration, and extracellular matrix secretion over 21 simulated days. Unknown parameters were calibrated with the Nelder-Mead algorithm against empirical data from four alginate hydrogel conditions. Predictions were validated against withheld experimental data for aggrecan accumulation and NP cell viability and against independent literature data for cell fold change, collagen, and cytokine secretion, with agreement quantified by root mean squared error, normalized RMSE, and coverage probability. The IVDH-ABM predicted NP cell proliferation of 8.3- to 9.2-fold by day 16, aggrecan stabilizing at 2700 to 2800 µg/mL in the low molecular weight conditions, and collagen-to-aggrecan ratios within the physiological range of 0.18 to 0.42. Cytokine dynamics tracked the reported literature ranges (normalized RMSE 0.25 to 0.40 for IL-1β and TGF-β). Late cell fold change was over-predicted relative to experimental values. Multi-objective screening identified an optimal formulation of 200 kDa alginate at 1.95% (w/v) crosslinked with 0.02 M calcium. Its predicted elasticity of 3.66 kPa was within the mechanical range of mature, non-degenerate NP tissue. The IVDH-ABM provides a computational framework for the in-silico screening of hydrogel biomaterials. This New Approach Methodology aligns with the growing emphasis on alternative non-animal methods for regenerative medicine research.
-
10. Integrating radiomic and perfusion kinetics from DCE-MRI for accurate prediction of pathological response to neoadjuvant chemotherapy.
PMID:日期:2026-09-10The prediction of pathological response outcome following neoadjuvant chemotherapy (NAC) in breast cancer is an important clinical task that aids treatment planning and personalized therapeutic strategies. Traditional prediction strategies require expert knowledge and are sometimes influenced by False Positive and False Negative outcomes. In this study, we propose a new multi-modal machine learning framework that combines the structural, textural and functional imaging biomarkers obtained from Dynamic Contrast-Enhanced MRI (DCE-MRI) for non-invasive classification of complete response (CR) and partial response (PR). The clinical dataset used in our study was collected at Annunziata Hospital, Cosenza, Italy (33 breast cancer patients total with confirmed response labels). The method investigates three complementary feature spaces: (i) quantitative perfusion and geometry parameters obtained from time-intensity curves capturing tumor vascular dynamics, (ii) radiomic features encoding intra-tumoral structural and textural heterogeneity, and finally (iii) a modal-aware late fusion using a Bayesian meta-learner integrating both descriptors. To prevent overfitting on medical imaging datasets, a stringent validation approach based on Nested Leave-One-Out Cross-Validation (Nested LOOCV) in conjunction with repeated Stratified 5 × 20 cross-validation was implemented. Accuracy was as high as 0.8955 with perfusion-based models, and a radiomic model yielded an accuracy score of 0.8982 using Mann-Whitney feature selection under Nested LOOCV. Overall, the multi-modal fusion approach achieved superior performance (0.9115 accuracy, 0.9054 F1-score, and 0.9488 ROC-AUC) using Random Forest classifier, which indicates that combining perfusion dynamics with radiomics enables a more clinically-relevant prediction of NAC response. This shows that the combination of perfusion dynamics with radiomic descriptors from DCE-MRI allows for better and more reliable prediction of NAC response. This proposed multimodal framework also emphasizes the promising role of imaging biomarkers in facilitating tailored treatment approaches for breast cancer.