JAPANESE JOURNAL OF APPLIED PHYSICS日本应用物理学杂志
JAPANESE JOURNAL OF APPLIED PHYSICS(英文缩写 JPN J APPL PHYS),ISSN 0021-4922,eISSN 1347-4065,中文译名:日本应用物理学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.491 | Q4 |
| 2022 | 1.500 | Q4 |
| 2023 | 1.500 | Q3 |
| 2024 | 1.800 | Q3 |
| 2025 | 1.700 | Q4 |
JAPANESE JOURNAL OF APPLIED PHYSICS 最新收录文献
-
1. Relationship between transmission/reception conditions of high-frequency plane wave compounding and evaluation accuracy of extended amplitude envelope statistics.
1. 高频平面波复合的发射/接收条件与扩展振幅包络统计量评估精度之间的关系PMID:日期:2024-04-25The double-Nakagami (DN) model provides a method for analyzing the amplitude envelope statistics of quantitative ultrasound (QUS). In this study, the relationship between the sound field characteristics and the robustness of QUS evaluation was evaluated using five HF linear array probes and tissue-mimicking phantoms. Compound plane-wave imaging (CPWI) was used to acquire echo data. Five phantoms containing two types of scatterers were used to mimic fatty liver tissue. After clarifying the relationship between the sound field characteristics of the probes and QUS parameters, DN QUS parameters in 10 rat livers with different lipidification were evaluated using one HF linear array probe. For both phantom and in situ liver analyses, correlations between fat content and multiple QUS parameters were confirmed, suggesting that the combination of CPWI using a HF linear array probe with the DN model is a robust method for quantifying fatty liver and has potential clinical diagnostic applications.
-
2. Backscatter properties of two-layer phantoms using a high-frequency ultrasound annular array.
PMID:日期:2022-05-30In a previous study, an annular-array transducer was employed to characterize homogeneous scattering phantoms and excised rat livers using backscatter envelope statistics and frequency domain analysis. A sound field correction method was also applied to take into account the average attenuation of the entire scattering medium. Here, we further generalized the evaluation of backscatter coefficient (BSC) using the annular array in order to study skin tissues with a complicated structure. In layered phantoms composed of two types of media with different scattering characteristics, the BSC was evaluated by the usual attenuation correction method, which revealed an expected large difference from the predicted BSC. In order to improve the BSC estimate, a correction method that applied the attenuation of each layer as a reference combined with a method that corrects based on the attenuation of the analysis position were applied. It was found that the method using the average attenuation of each layer is the most effective. This correction method is well adapted to the extended depth of field provided by an annular array.
-
3. Improved evaluation of backscatter characteristics of soft tissue using high-frequency annular array.
PMID:日期:2020-05-07Clinical ultrasound is widely used for quantitative diagnosis. To clarify the relationship between anatomical and acoustic properties, high resolution imaging using high-frequency ultrasound (HFU) is required. However, when tissue properties are evaluated using HFU, the depth of field (DOF) is limited. To overcome this problem, an annular array transducer, which has a simple structure and produces high-quality images, is applied to HFU measurement. In previous phantom experiments, we demonstrated that the HFU annular array extends the DOF compared to that of a single-element transducer for quantitative ultrasound (QUS) analysis. Here, we extend that work by applying QUS methods to an ex vivo rat liver. The present study demonstrates that an annular array extends the region and improves the resolution for tissue characterization for an excised healthy rat liver. Amplitude envelope statistics and spectral-based analysis are used as QUS methods.
-
4. Comprehensive backscattering characteristics analysis for quantitative ultrasound with an annular array: a basic study on homogeneous scattering phantom.
4. 环形阵列定量超声的全散射特性综合分析:均匀散射体模的基础研究PMID:日期:2019-06-13High-frequency ultrasound (HFU, >20 MHz) and quantitative ultrasound (QUS) methods permit a means to understand the relationship between anatomical and acoustic characteristics. In our previous research, we showed that analyzing the acoustic scattering with HFU was an effective method for noninvasive diagnosis. However, the depth of field (DOF) of HFU transducers was limited, which constrains the range of QUS analysis. In this study, we seek to improve the accuracy of HFU, QUS-based parameters on the envelope statistics and frequency-based analysis by using an annular array that allows for an extended DOF. A 20-MHz annular-array transducer with five elements was employed to obtain signals which were beamformed in post-processing. Two kinds of low concentration scattering phantoms were scanned with 30-m step size. Two QUS analysis techniques were employed: the Nakagami distribution and the reflector method. The results demonstrated that the annular array provides a stable analysis over an extended axial range.
-
5. The role of Si in GaN/AlN/Si(111) plasma assisted molecular beam epitaxy: polarity and inversion.
5. Si在GaN/AlN/Si(111)等离子体辅助分子束外延中的作用:极性与反转PMID:日期:2019-05-22The microstructure, polarity and Si distribution in AlN/GaN layers grown by plasma assisted molecular beam epitaxy (PAMBE) on Si(111) was assessed by scanning transmission electron microscopy (STEM). Samples grown under both metal- and nitrogen-rich conditions contained defects at the AlN/Si interface which suggest formation of an Al-Si eutectic. Correlated with this, interfacial segregation of Si was found in the samples. It is proposed that Si is dissolved in a eutectic layer floating on the AlN surface under metal-rich conditions. This Si is then incorporated into the film if the growth becomes nitrogen-rich, either intentionally or due to plasma source transients. These Si-rich layers appear to induce inversion of the nitride from nitrogen- to metal-polarity, and uncontrolled variations in the Si concentration cause occasional nonuniformity in the resulting inversion.
-
6. Fluid flow measurement for diagnosis of ventricular shunt malfunction using nonlinear responses of microbubbles in the contrast-enhanced ultrasound imaging.
6. 利用超声造影成像中微泡的非线性响应进行流体流动测量以诊断心室分流故障PMID:日期:2017-06-13Contrast-enhanced ultrasound imaging utilizing the nonlinear responses of microbubbles is proposed for identifying ventricular shunt malfunction. The developed method suppresses the signal from walls of a shunt catheter and background tissues, and allows accurate measurements of the cerebrospinal fluid flow within the shunt catheter using a relatively small concentration of microbubbles. The flow rates estimated in the linear mode were significantly underestimated (65% at 0.1 ml/min and 5.0% microbubble concentration) while estimates using the nonlinear mode were not. Overall, the nonlinear responses of microbubbles improve the estimation of flow rates in a shunt catheter at low concentrations of microbubbles.
-
7. Modeling the envelope statistics of three-dimensional high-frequency ultrasound echo signals from dissected human lymph nodes.
7. 离体人淋巴结三维高频超声回声信号包络统计建模PMID:日期:2014This work investigates the statistics of the envelope of three-dimensional (3D) high-frequency ultrasound (HFU) data acquired from dissected human lymph nodes (LNs). Nine distributions were employed, and their parameters were estimated using the method of moments. The Kolmogorov Smirnov (KS) metric was used to quantitatively compare the fit of each candidate distribution to the experimental envelope distribution. The study indicates that the generalized gamma distribution best models the statistics of the envelope data of the three media encountered: LN parenchyma, fat and phosphate-buffered saline (PBS). Furthermore, the envelope statistics of the LN parenchyma satisfy the pre-Rayleigh condition. In terms of high fitting accuracy and computationally efficient parameter estimation, the gamma distribution is the best choice to model the envelope statistics of LN parenchyma, while, the Weibull distribution is the best choice to model the envelope statistics of fat and PBS. These results will contribute to the development of more-accurate and automatic 3D segmentation of LNs for ultrasonic detection of clinically significant LN metastases.
-
8. Investigation of SNARE-Mediated Membrane Fusion Mechanism Using Atomic Force Microscopy.
8. 利用原子力显微镜研究SNARE介导的膜融合机制PMID:日期:2009-08Membrane fusion is driven by specialized proteins that reduce the free energy penalty for the fusion process. In neurons and secretory cells, soluble N-ethylmaleimide-sensitive factor-attachment protein (SNAP) receptors (SNAREs) mediate vesicle fusion with the plasma membrane during vesicular content release. Although, SNAREs have been widely accepted as the minimal machinery for membrane fusion, the specific mechanism for SNARE-mediated membrane fusion remains an active area of research. Here, we summarize recent findings based on force measurements acquired in a novel experimental system that uses atomic force microscope (AFM) force spectroscopy to investigate the mechanism(s) of membrane fusion and the role of SNAREs in facilitating membrane hemifusion during SNARE-mediated fusion. In this system, protein-free and SNARE-reconstituted lipid bilayers are formed on opposite (trans) substrates and the forces required to induce membrane hemifusion and fusion or to unbind single v-/t-SNARE complexes are measured. The obtained results provide evidence for a mechanism by which the pulling force generated by interacting trans-SNAREs provides critical proximity between the membranes and destabilizes the bilayers at fusion sites by broadening the hemifusion energy barrier and consequently making the membranes more prone to fusion.