IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENTIEEE仪器与测量汇刊
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT(英文缩写 IEEE T INSTRUM MEAS),ISSN 0018-9456,eISSN 1557-9662,中文译名:IEEE仪器与测量汇刊 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 5.332 | Q1 |
| 2022 | 5.600 | Q1 |
| 2023 | 5.600 | Q1 |
| 2024 | 5.900 | Q1 |
| 2025 | 7.000 | Q1 |
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 最新收录文献
-
1. High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries.
PMID:日期:2026-02-13Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities ( ) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot-Savart predictions. The OPM achieves an optimal field sensitivity of , demonstrating the system's capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery . These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.
-
2. Wearable Ultrasound Sensing with Dual Arrays and Machine Learning for Real-Time Tremor Characterization and Antagonist Muscle Monitoring.
2. 用于实时震颤表征和拮抗肌监测的双阵列与机器学习可穿戴超声传感PMID:日期:2026-01-16Precise and time-efficient sensing of tremor dynamics is essential for developing personalized, adaptive stimulation strategies for movement disorders such as Parkinson's Disease (PD) and Essential Tremor (ET). Existing modalities-such as inertial measurement units (IMUs) and surface electromyography (EMG)-lack muscle specificity and are prone to stimulation artifacts. To address these limitations, we fabricated and applied a Wearable Ultrasound Sensing (WUS) system, featuring dual flexible 64- element transducer arrays with center frequency of 6 MHz conformed over the flexor carpi radialis (FCR) and extensor carpi radialis (ECR) muscles for simultaneous antagonist muscle monitoring. A machine learning (ML) pipeline was introduced to estimate tissue displacement (TD) from raw ultrasound signals. Across three participants and multiple trials, the WUS system achieved tremor frequency detection within 10 % variation relative to commercial B-mode and IMU sensors, and met statistical equivalence thresholds based on two one-sided test (TOST) analysis. The TD estimation models demonstrated high predictive accuracy, with overall Pearson correlation coefficients between predicted and actual values ranging from 0.88 to 0.97, normalized RMSE values below 10 %, and offline model building times under 800 seconds. Compared to classical B-mode speckle tracking, the proposed WUS-ML pipeline reduced offline model building time by 75 % (from 3095 sec to 792 sec). In real-time performance tests, it reduced frame-level latency from 3700 ms to 17 ms and achieved effective processing rates exceeding 50 Hz, well above the Nyquist threshold for tremor analysis. These results demonstrate the feasibility of dual-array wearable ultrasound for accurate, low-latency tremor tracking and lay the groundwork for future closed-loop afferent stimulation systems in both clinical and at-home environments.
-
4. Cross-Detection for Bubble-free Thermometer Codes and Dual-Side Monitoring for FPGA-Based High-Accuracy and High-Precision Time-to-Digital Converters.
4. 用于无气泡温度计码的交叉检测与基于FPGA的高精度高准确度时间数字转换器的双侧监测PMID:日期:2025-12-11This study presents a novel field-programmable gate array (FPGA)-based time-to-digital converter (TDC) architecture designed for high-resolution timing applications, incorporating two innovative techniques. First, a cross-detection (CD) method modifies the sampling pattern to minimize bubbles in thermometer codes, which are a primary source of inaccuracy in TDC timing measurements. By eliminating these bubbles, the method reduces the average bin size by half. Second, dual-side monitoring (DSM) simultaneously captures both end-of-propagation (EOP) and start-of-propagation (SOP) thermometer codes. Unlike conventional TDCs that rely solely on SOP, DSM leverages EOP to calibrate SOP, thereby enhancing time resolution and improving stability under temperature and location variations. The proposed DSM scheme requires only two additional CARRY4s to capture EOP, offering a resource-efficient alternative to conventional TDC designs. The proposed CD-DSM TDC was implemented on a Xilinx Virtex-7 (XC7VX485T-2FFG1761C) FPGA, achieving an average bin size of 5.6 ps and a root mean square bin distribution of 6.4 ps. It demonstrates superior linearity, with a differential non-linearity (DNL) range of [-0.9, 2.7] least significant bits (LSB) and an integral non-linearity (INL) range of [-2.1, 8.1] LSB. The ultra-high timing resolution of two Cerenkov radiator integrated microchannel plate photomultiplier tubes was successfully measured using two identical CD-DSM TDCs. The full width at half maximum of the measured coincidence timing histogram was 83 ± 3.5 ps, closely matching the 85 ± 4.8 ps timing resolution obtained using a high-precision oscilloscope. A comparison with state-of-the-art TDCs highlights the superior performance of the CD-DSM TDC.
-
5. Pixel Latency Measurements of Event Cameras.
5. 事件摄像机的像素延迟测量PMID:日期:2025-10-21Pixel latency of event cameras is an important parameter to take into account in real-time applications. Currently, pixel latency is insufficiently described in event camera specifications as a "typical latency at a certain light level." This work is motivated by the need to have a well-defined pixel latency measurement since the latency depends on the irradiance of the stimulus, the event camera configuration, and the number of active pixels. The problem lies in defining a hardware setup and a measurement procedure that could be reproduced by event camera vendors to specify pixel latency and then used by event camera consumers for selecting event cameras according to their real-time applications. The challenges of solving the problem involve selecting accessible hardware for all vendors, precisely specifying the hardware configuration and measurement procedure, and defining the pixel latency metrics that are directly related to real-time applications. We describe such a solution and report pixel latency measurements for three event cameras to illustrate the reproducibility aspects and the value added to the deployment of event cameras in practice. The interactive visualization of all latency measurements is available from https://usnistgov.github.io/pixel_latency_eventcameras/.
-
6. Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method.
PMID:日期:2025-05-15Positron emission tomography (PET) is the most sensitive molecular instrumentation. The image quality of PET can be significantly enhanced by incorporating time-of-flight (TOF) and depth-of-interaction (DOI) information. In this study, whole-body TOF-DOI PET detectors based on the dual-ended readout method were developed to simultaneously provide good TOF and DOI information. Each detector consisted of two 8 × 8 Hamamatsu S14161-3050-08 silicon photomultiplier (SiPM) arrays coupled to both ends of an 8 × 8 lutetium-yttrium oxyorthosilicate (LYSO) array with a thickness of 20 mm. Both the LYSO and SiPM arrays had a pitch of 3.2 mm, allowing each LYSO element to be coupled to two SiPM elements, one at each end of the crystal, to achieve the optimal timing resolution. Experimental results demonstrated that the detectors achieved a coincidence timing resolution of 234 ± 7 ps, an energy resolution of 13.7 ± 2.0%, and a DOI resolution of 2.6 ± 0.2 mm. These results suggest that the developed detectors are suitable for constructing whole-body TOF-DOI PET scanners with uniform spatial resolution across the entire field-of-view.
-
7. A Wearable Gait Monitoring System for 17 Gait Parameters Based on Computer Vision.
PMID:日期:2025-04-04We demonstrate a shoe-mounted gait monitoring system capable of tracking up to 17 gait parameters, including step length, step time, stride velocity, among others. The system employs a stereo camera mounted on one shoe to track a marker placed on the opposite shoe, enabling the estimation of spatial gait parameters. Additionally, a force sensitive resistor (FSR) affixed to the heel of the shoe, combined with a custom-designed algorithm, is utilized to measure temporal gait parameters. Through testing on multiple participants and comparison with a gait mat, our gait monitoring system exhibited excellent performance, with all 17 gait parameters exceeding 93.61% in measurement accuracy. The system also demonstrated a low drift of 4.89% during long walking sessions. A gait identification task conducted on participants using a trained transformer model achieved 95.7% accuracy on the dataset collected by our system, indicating the potential of our system to collect long-sequence, varied gait data suitable for training current large language models (LLMs). The system is cost-effective, user-friendly, and well-suited for real-life measurements.
-
8. Measuring Subtle HD Data Representation and Multimodal Imaging Phenotype Embedding for Precision Medicine.
8. 面向精准医学的细微HD数据表征与多模态影像表型嵌入测量PMID:日期:2025-03-03High-dimensional (HD) imaging biomarkers offer enhanced imaging characterization, yet their abundance impedes system performance. The methods that embed HD onto lower dimensional (LD) space address this challenge effectively, particularly for multimodal scenarios. In this study, we proposed different embedding approaches to tackle such a problem. The shortest path algorithm for isometric mapping (Isomap) is modified by an additional constraint using the Parzen-Rosenblatt (PR) density function. This aids in maintaining the uniformity of the graphs through HD to LD projections via Isomap. Then, we proposed Gaussian and Kaniadakis entropy-driven, , Gaussian embedding techniques to interact with multimodal imaging phenotypic biomarkers. We comprehensively tested our methods on a combination of multiple imaging datasets related to various diseases across multiple modalities, i.e., computed tomography (CT), positron emission tomography (PET), X-ray, magnetic resonance imaging (MRI), ultrasound, and thermography, for an overall of 5158 cases. Our findings demonstrate that our embedding methods effectively transform HD to LD attributes comparatively while retaining vital information and performing phenotypic interactions. Our embedding techniques achieved the maximum accuracies of 78.5% (±4.4), 88.4% (±1.4), and 61.4% (±11.4), 80.9% (±5.8), 80.3% (±5.5), 82.9% (±2.3), and 63.2% (±7.7) for three lung cancer data, pneumonia, breast cancer ultrasound, thermography, and glioblastoma (GBM) diseases, respectively. This accuracy improved with -Gaussian and Gaussian embedding yielded 79.7%(±2.7) and 80.4%(±3.7) for lung cancer and 65.01% (±3.7) and 62.6% (±7.8) for GBM, respectively. The results of survival models and Kaplan-Meier survival curve also indicate the notable ability of our embedding approaches to distinguish between patients with different median hazards indicating the preservation of HD multimodal imaging characteristics for precision medicine.
-
9. The Expected Peak-to-Average Power Ratio of White Gaussian Noise in Sampled I/Q Data.
PMID:日期:2025One of the fundamental endeavors in radio frequency (RF) metrology is to measure the power of signals, where a common aim is to estimate the peak-to-average power ratio (PAPR), which quantifies the ratio of the maximum (peak) to the mean value. For a finite number of discrete-time samples of baseband in-phase and quadrature (I/Q) white Gaussian noise (WGN) that are independent and identically distributed with zero mean, we derive a closed-form, exact formula for mean PAPR that is well-approximated by the natural logarithm of the number of samples plus Euler's constant. Additionally, we give related theoretical results for the mean crest factor. After comparing our main result to previously published approximate formulas, we examine how violations of the WGN assumptions in sampled I/Q data result in deviations from the expected value of PAPR. Finally, utilizing a measured RF I/Q acquisition, we illustrate how our formula for mean PAPR can be applied to spectral analysis with spectrograms to verify when measured RF emissions are WGN in a given frequency band.
-
10. Lightweight Retinal Layer Segmentation With Global Reasoning.
10. 基于全局推理的轻量级视网膜层分割PMID:日期:2024-05-21Automatic retinal layer segmentation with medical images, such as optical coherence tomography (OCT) images, serves as an important tool for diagnosing ophthalmic diseases. However, it is challenging to achieve accurate segmentation due to low contrast and blood flow noises presented in the images. In addition, the algorithm should be light-weight to be deployed for practical clinical applications. Therefore, it is desired to design a light-weight network with high performance for retinal layer segmentation. In this paper, we propose LightReSeg for retinal layer segmentation which can be applied to OCT images. Specifically, our approach follows an encoder-decoder structure, where the encoder part employs multi-scale feature extraction and a Transformer block for fully exploiting the semantic information of feature maps at all scales and making the features have better global reasoning capabilities, while the decoder part, we design a multi-scale asymmetric attention (MAA) module for preserving the semantic information at each encoder scale. The experiments show that our approach achieves a better segmentation performance compared to the current state-of-the-art method TransUnet with 105.7M parameters on both our collected dataset and two other public datasets, with only 3.3M parameters.