IEEE JOURNAL OF SOLID-STATE CIRCUITSIEEE固态电路杂志
IEEE JOURNAL OF SOLID-STATE CIRCUITS(英文缩写 IEEE J SOLID-ST CIRC),ISSN 0018-9200,eISSN 1558-173X,中文译名:IEEE固态电路杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 6.126 | Q1 |
| 2022 | 5.400 | Q1 |
| 2023 | 4.600 | Q1 |
| 2024 | 5.600 | Q1 |
| 2025 | 5.600 | Q1 |
IEEE JOURNAL OF SOLID-STATE CIRCUITS 最新收录文献
-
1. A Scalable 1024-Channel Ultra-Low-Power Spike Sorting Chip with Event-Driven Detection and Spatial Clustering.
1. 一种具有事件驱动检测和空间聚类的可扩展1024通道超低功耗尖峰分类芯片PMID:日期:2025-10-01This paper presents a 1024-channel ultra-low-power spike sorting chip featuring event-driven spike detection and spatial clustering for large-scale neural recording. To address power and scalability constraints in brain-computer interfaces, the design integrates a compressive ADC with a two-stage spike detector that significantly reduces memory and processing activity. Spatial features derived from high-density microelectrode array (MEA) enhance cluster separability, enabling robust performance even under neural signal distortion or probe drift, particularly when recordings are obtained using planar MEAs. A modified self-organizing map algorithm clusters spikes in the spatial domain with minimal memory access, supporting on-chip training and real-time operation with low latency. Fabricated in 40 nm CMOS, the chip achieves 0.00029 mm/channel area and 74 nW/channel power consumption, with over 1000× data compression. Performance is validated across synthetic and ex vivo datasets containing up to 500 neurons, demonstrating competitive accuracy and robust drift tracking compared to state-of-the-art solutions with much lower data bandwidth, processing, and power demands.
-
2. A One-Step-Packaged CMOS/Microfluidics Wireless Bio-Analyzer for Point-of-Care Diagnostics.
2. 一种用于即时诊断的一步封装CMOS/微流控无线生物分析仪PMID:日期:2025-09-16Point-of-care (POC) diagnostics can revolutionize current medicine by enabling rapid, at-home molecular testing for early disease detection and treatment monitoring. Though several mainstream POC technologies exist, such as paper-based lateral flow assays (LFAs) and microfluidic cartridges, they either lack quantification capability or require a dedicated reader for electrical readout. Miniaturization enabled by high-performance CMOS integrated circuits (ICs) has been proposed to address these limitations, but complex CMOS/microfluidics packaging due to the need for electrical connections remains a significant challenge. In this work, we present a fully wireless solution based on near-field inductive coupling. By enabling wireless power and data communication through a 1.5-mm on-chip coil operating at 700 MHz, the CMOS chip can be seamlessly embedded into standard microfluidics fabrication flows. The proposed CMOS bio-analyzer supports electrochemical, pH, and temperature sensing. The electrochemical front end performs highly sensitive readout from immunosensors, while the pH and temperature sensors are used to mitigate environmental effects. Implemented in TSMC 180-nm CMOS technology, the system consumes 2 mA from a rectified 2.5-V supply. The electrochemical sensor employs a fully differential capacitive transimpedance amplifier (TIA) and achieves 0.24-pA input-referred current noise and 128.8 dB of extended dynamic range. Immunosensing of C-reactive protein (CRP) and a prototype vacuum-driven microfluidics device are demonstrated.
-
3. {"_":"NeuroFlare: An mm-Scale Wireless Neural Interface Device with Simultaneous Neural Recording and Optical Stimulation.","sup":["3"]}
3. {"_":"NeuroFlare:一种毫米级无线神经接口设备,可同时进行神经记录和光学刺激。","sup":["3"]}PMID:日期:2025-01-29This paper presents the creation of a wireless, miniature implantable opto-electro neural interface device called NeuroFlare, capable of simultaneous neural recording and optical stimulation. NeuroFlare features a low-power, dual-modal application-specific integrated circuit (ASIC) fabricated using the 180 nm CMOS process. To support the power-intensive optical stimulation in NeuroFlare, the ASIC employs a novel linear-charging switched-capacitor stimulation (LC-SCS) structure. The LC-SCS, operating under only a 1.2 V supply voltage, can illuminate the LED with a driving voltage three times the supply voltage and large current pulses of up to 12 mA while maintaining a high charging efficiency of 86.4%. In addition, LC-SCS requires only one off-chip capacitor, greatly facilitating device miniaturization. To accurately record neural signals in the presence of stimulation artifacts, the ASIC employs a delta-sigma modulator ( )-based recording frontend with a wide dynamic range (DR) to directly digitize the neural signals. The features a 2-order loop architecture implemented using a linearized Gm-C integrator followed by an active noise-shaping (NS) successive approximation register (SAR) quantizer. The with power consumption of 9.8 μW provides a peak DR of 83.7 dB, corresponding to a 400 mV linear input range. The 's 173.8 dB Figure-of-Merit ( ) indicates its superior energy efficiency. The ASIC is assembled into a prototype of NeuroFlare measuring 2.8 × 3.5 × 0.7 mm. The recorded light-evoked local field potential (LFP) verified the functionality of NeuroFlare .
-
4. A Nonuniform Sampling Lifetime Estimation Technique for Luminescent Oxygen Measurements for Biomedical Applications.
PMID:日期:2024-12-20This article presents a novel technique that is immune to offset, enabling precise determination of the lifetime of luminescent materials. The technique is specifically applied to measure transcutaneous oxygen, an indicator of oxygen that diffuses through the skin and reflects arterial oxygen levels. Unlike intensity-based measurements, lifetime-based luminescence measurements are superior because they decouple oxygen information from confounding factors. The technique presented in this work involves measuring the time difference between fixed-voltage steps to extract the time constant of a decaying exponential, which represents the lifetime of luminescence. We propose a novel switched-capacitor circuit that enables long integration times and prevents the front-end amplifier from saturating. The analog subsystem was realized in 180-nm CMOS technology via a transimpedance amplifier (TIA) with a gain bandwidth product of 10 MHz, a comparator, and a switched capacitor circuit. The measured mean error is as accurate as 1.9% without postprocessing. During a 130 s measurement period, the readout circuit consumes a maximum of 16 J per calculation with a . Preliminary human subject tests have demonstrated that the sensor can effectively detect changes in transcutaneous oxygen levels resulting from arterial occlusion.
-
5. A 2.5-20 kSps in-pixel direct digitization ECoG front-end with sub-millisecond stimulation artifact recovery.
PMID:日期:2024-12-18Neural stimulation is used routinely to diagnose and treat neurological disorders. However, the stimulation artifacts are problematic for closed-loop neuromodulation therapy, which dynamically adjusts the electrical stimulation parameters based on real-time feedback from recording neural activity, because they can cause saturation or prolonged recovery times in traditional recording front-ends. This paper presents a per-pixel 2-order ADC for direct digitization of neural signals, which addresses the stimulation artifact recovery time in voltage-controlled oscillator (VCO)-based quantizers with a fast-recovery, overrange-detecting phase quantizer. The ADC uses a pseudo-virtual ground feedforwarding (PVG FF) technique and a complementary input filter with per-pixel decimation. It supports four recording modes covering 2.5-20 kSps through a power-efficient, bandwidth-scalable continuous time modulator. Fabricated in a 180-nm CMOS process, this 300×300 μm ADC achieves >250× faster (0.05-0.4 ms) stimulation artifact recovery time, enabling in-stimulation recording. Recording with artifact tolerance was demonstrated through an whisker barrel rat experiment.
-
6. Omnidirectional Wireless Power Transfer for Millimetric Magnetoelectric Biomedical Implants.
6. 用于毫米磁电生物医学植入物的全向无线功率传输PMID:日期:2024-10-11Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in today's devices. Despite successful demonstrations of millimetric battery-free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery. This paper presents an omnidirectional WPT platform for millimetric bioelectronic implants, employing the emerging magnetoelectric (ME) WPT modality, and "magnetic field steering" technique based on multiple transmitter (TX) coils. To accurately sense the weak coupling in a miniature implant and adaptively control the multi-coil TX array in a closed loop, we develop an Active Echo (AE) scheme using a tiny coil on the implant. Our prototype comprises a fully integrated 14.2mm implantable stimulator embedding a custom low-power System-on-Chip (SoC) powered by an ME film, a transmitter with a custom three-channel AE RX chip, and a multi-coil TX array with mutual inductance cancellation. The AE RX achieves -161dBm/Hz input-referred noise with 64dB gain tuning range to reliably sense the AE signal, and offers fast polarity detection for driver control. AE simultaneously enhances the robustness, efficiency, and charging range of ME WPT. Under 90° rotation from the ideal position, our omnidirectional WPT system achieves 6.8× higher power transfer efficiency (PTE) than a single-coil baseline. The tracking error of AE negligibly degrades the PTE by less than 2% from using ideal control.
-
7. A Wireless, Multicolor Fluorescence Image Sensor Implant for Real-Time Monitoring in Cancer Therapy.
7. 一种用于癌症治疗实时监测的无线多色荧光图像传感器植入物PMID:日期:2024-08-08Real-time monitoring of dynamic biological processes in the body is critical to understanding disease progression and treatment response. This data, for instance, can help address the lower than 50% response rates to cancer immunotherapy. However, current clinical imaging modalities lack the molecular contrast, resolution, and chronic usability for rapid and accurate response assessments. Here, we present a fully wireless image sensor featuring a 2.5×5 mm CMOS integrated circuit for multicolor fluorescence imaging deep in tissue. The sensor operates wirelessly via ultrasound (US) at 5 cm depth in oil, harvesting energy with 221 mW/cm incident US power density (31% of FDA limits) and backscattering data at 13 kbps with a bit error rate <10. In-situ fluorescence excitation is provided by microlaser diodes controlled with a programmable on-chip driver. An optical frontend combining a multi-bandpass interference filter and a fiber optic plate provides >6 OD excitation blocking and enables three-color imaging for detecting multiple cell types. A 36×40-pixel array captures images with resolution. We demonstrate wireless, dual-color fluorescence imaging of both effector and suppressor immune cells in mouse tumor samples with and without immunotherapy. These results show promise for providing rapid insight into therapeutic response and resistance, guiding personalized medicine.
-
8. Monolithic Electronic-Biophotonic System-on-Chip for Label-Free Real-Time Molecular Sensing.
PMID:日期:2024-04-09Label-free miniaturized optical sensors can have a tremendous impact on highly sensitive and scalable Point-of-Care (PoC) diagnostics by monitoring in real-time molecular interactions without any labels. However, current biophotonic platforms are limited by complex optical and external readout equipment, precluding their use in a PoC setting. In this work, we address this challenge by developing a first-of-its-kind fully integrated electronic-photonic label-free molecular sensor utilizing micro-ring resonators (MRRs) co-integrated with on-chip electronics in a high-volume advanced electronic process. In particular, we present an arrayed electronic-photonic system-on-chip (EPSoC) in GlobalFoundries (GF) 45-nm RFSOI with sixty 5-um radius MRRs connected to on-chip receivers, approaching an idealized limit of detection (LoD) equivalent to a single 140-nm viral particle. To further enhance the LoD, we propose a dual-ring phase-based sensing architecture, boosting the system's sensitivity by 3.7 compared to our previously reported intensity-based single MRR scheme. An integrated heater embedded in the design of the ring and an on-chip controller lock the ring's resonance at the desired point of operation, eliminating the need for a tunable laser. The inherent intrinsic limitations of MRRs due to ambient temperature variations are addressed with an on-chip differential scheme using sensing and reference rings to cancel common mode errors. We demonstrate the sensing capabilities of the EPSoC by monitoring in real-time binding events of Bovine Serum Albumin (BSA), anti-BSA molecules and streptavidin-coated nanoparticles, unlocking the door towards self-contained fully integrated Lab-on-Chip (LoC) photonic sensors for PoC applications.
-
9. {"_":"A Sub-mm Wireless Neural Stimulator IC for Visual Cortical Prosthesis With Optical Power Harvesting and 7.5-kb/s Data Telemetry.","sup":["3"]}
9. {"_":"一种用于视觉皮层假体的亚毫米级无线神经刺激器集成电路,具有光能收集和PMID:日期:2024-01-30This article proposes StiMote, an untethered, free-floating and individually addressable stimulator mote designed for visual cortex stimulation, aimed at vision restoration. The system is optically powered by a custom photovoltaic (PV) layer. In addition, the photodiode (PD) layer captures the light modulation and forwards it to the optical receiver (ORX) including a tranimpedance amplifier. Translated instructions can assign a unique slot, up to 1024 available, to each mote within the time-division multiple access (TDMA) framework. In this work, we propose an automatic charge balance (CB) technique that monitors the injected charge to balance in bi-phasic switched-capacitor stimulation (SCS). The chip was confirmed fully functional when operated completely wirelessly using harvested light. Measurement results revealed a power consumption of 4.48 W with a 7.5-kb/s optical downlink data rate, corresponding to continuous updates at 2.5 Hz of 1024 motes to their individual 3-b stimulation intensity levels. The dc-dc converter, responsible for providing high voltage for stimulation, demonstrated 4.3-V output voltage when unloaded, with a maximum efficiency of 67.4%. The proposed CB circuit exhibited linear controllability of stimulation charge up to 16 nC, with a charge imbalance of less than 0.2 nC. Furthermore, in vitro testing confirmed the absence of chemical reactions at electrodes, and in vivo experiments conducted on live rats verified the effectiveness of the stimulation through StiMote.
-
10. {"_":"A 1024-Channel 268 nW/pixel 36×36 m/channel Data-Compressive Neural Recording IC for High-Bandwidth Brain-Computer Interfaces.","i":["μ"],"sup":["2"]}
PMID:日期:2023-12-29This paper presents a data-compressive neural recording IC for single-cell resolution high-bandwidth brain-computer interfaces. The IC features wired-OR lossy compression during digitization, thus preventing data deluge and massive data movement. By discarding unwanted baseline samples of the neural signals, the output data rate is reduced by 146× on average while allowing the reconstruction of spike samples. The recording array consists of pulse position modulation-based active digital pixels with a global single-slope analog-to-digital conversion scheme, which enables a low-power and compact pixel design with significantly simple routing and low array readout energy. Fabricated in a 28-nm CMOS process, the neural recording IC features 1024 channels (i.e., 32 × 32 array) with a pixel pitch of 36 m that can be directly matched to a high-density microelectrode array. The pixel achieves 7.4 V input-referred noise with a -3 dB bandwidth of 300-Hz to 5-kHz while consuming only 268 nW from a single 1-V supply. The IC achieves the smallest area per channel (36 × 36 m) and the highest energy efficiency among the state-of-the-art neural recording ICs published to date.