水交换对接受严重主动脉瓣狭窄治疗患者动态对比增强MRI心肌血流量和细胞外容积分数估计的影响

The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast-Enhanced MRI in Patients Treated for Severe Aortic Stenosis.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

探讨细胞内/外水交换(WX)对重度主动脉瓣狭窄(AS)患者定量动态对比增强(DCE)MRI的影响。研究目的是比较低剂量(WX不敏感)和高剂量(WX敏感)DCE-MRI测量结果,并比较主动脉瓣置换术(AVR)前后采集的数据,以检验DCE-MRI能否检测心肌细胞外容积分数(ECV)的变化。对25例重度AS患者在3 T下于AVR前及AVR后6个月进行研究。DCE-MRI在静息状态下进行两次,先使用低对比剂剂量(0.05 mmol/kg钆布醇),随后使用高剂量(0.1 mmol/kg钆布醇)。采用假设瞬时WX(快速交换[FX])的模型和纳入WX的模型(双位点交换[2SX]模型)获得心肌血流量(MBF)和ECV的估计值。还使用对比剂给药前后采集的T1图进行ECV估计,分别采用假设FX和纳入WX的方法。AVR前获得的FX模型MBF和ECV估计值从低剂量到高剂量对比剂均降低,与WX受限的效应一致。这种降低在使用2SX模型后得到部分校正。然而,在24个高剂量数据集中,仅2个数据集的2SX模型拟合优于FX拟合(F检验)。使用DCE-MRI获得的ECV估计值在AVR后升高,与使用T1图所见的变化一致,但ECV估计值较低。使用DCE-MRI获得的MBF估计值对WX的敏感性可忽略不计。基于DCE-MRI的ECV估计值在AVR后发生变化,但系统性地低于使用T1图获得的估计值。

Abstract

To investigate the impact of intra/extracellular water exchange (WX) on quantitative dynamic contrast-enhanced (DCE) MRI in patients with severe aortic stenosis (AS). The aims were to compare low-dose (WX insensitive) and high-dose (WX sensitive) DCE-MRI measurements, and to compare data acquired before and after aortic valve replacement (AVR) to test whether DCE-MRI was able to detect changes in myocardial extracellular volume fraction (ECV). Twenty-five patients with severe AS were studied at 3 T before and 6 months after AVR. DCE-MRI was performed at rest twice using a low contrast agent dose (0.05 mmol/kg gadobutrol) followed by a high-dose (0.1 mmol/kg gadobutrol). Estimates of myocardial blood flow (MBF) and ECV were obtained using models which assume instantaneous WX (fast exchange [FX]) and which incorporate WX (a two-site exchange [2SX] model). ECV estimates were also made using T1 maps acquired before and after contrast administration, both assuming FX and incorporating WX. FX model estimates of MBF and ECV obtained before AVR decreased from low- to high-dose contrast consistent with the effect of limited WX. This decrease was partially corrected using a 2SX model. However, 2SX model fits were preferred over FX fits in only 2 of 24 high-dose data sets (F-test). ECV estimates made using DCE-MRI increased after AVR consistent with changes seen using T1 maps, but the ECV estimates were lower. Estimates of MBF using DCE-MRI showed negligible sensitivity to WX. DCE-MRI-based ECV estimates changed post-AVR but were systematically lower than those made using T1 maps.

如何引用

AMA

Alex Makins, John D Biglands, Noor Sharrack, Peter Kellman, Sven Plein, David L Buckley. The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast-Enhanced MRI in Patients Treated for Severe Aortic Stenosis.. Magnetic resonance in medicine. 2026; doi:10.1002/mrm.70571.

APA

Alex Makins, John D Biglands, Noor Sharrack, Peter Kellman, Sven Plein, David L Buckley (2026). The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast-Enhanced MRI in Patients Treated for Severe Aortic Stenosis.. Magnetic resonance in medicine. https://doi.org/10.1002/mrm.70571

GB/T 7714

Alex Makins, John D Biglands, Noor Sharrack, Peter Kellman, Sven Plein, David L Buckley. The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast-Enhanced MRI in Patients Treated for Severe Aortic Stenosis.[J]. Magnetic resonance in medicine, 2026 doi:10.1002/mrm.70571.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Magnetic resonance in medicine 的其他文献