胎儿脑中bSSFP的年龄特异性对比优化

Age-Specific Contrast Optimization of bSSFP in Fetal Brain.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

平衡稳态自由进动(bSSFP)能够实现胎儿脑的快速采集,但其组织对比度固有偏低。本研究旨在开发一种针对bSSFP的年龄特异性优化策略,以增强发育中胎儿脑的灰质-白质(GM-WM)对比度。研究设计了一套适用于二维和三维bSSFP序列的优化流程,将驱动平衡过渡(TIDE)模型与扩展相位图(EPG)算法相结合。利用从胎儿脑测得的T1和T2弛豫时间,该流程推导出年龄特异性的可变翻转角(VFA)序列,在约束信噪比(SNR)和点扩散函数的前提下最大化GM-WM对比度。以相对对比度和分割准确度为基础,将性能与默认bSSFP及T2加权半傅里叶采集单次激发涡轮自旋回波(HASTE)序列进行基准比较。对比度增强效果在18例24至37孕周的胎儿脑队列中进行了评估。优化后的二维和三维bSSFP序列较默认bSSFP产生了显著更高的相对皮层对比度(二维p < 0.001,三维p < 0.002),平均分别提升4.13倍和4.06倍。此外,在分割任务中,优化图像的分割准确度显著高于HASTE图像(优化二维bSSFP的DICE = 0.93,优化三维bSSFP为0.89,而HASTE为0.79)。所提出的年龄特异性bSSFP优化策略增强了对不同孕周胎儿GM-WM对比度的表征。这种易于转化的方法有望推动胎儿脑的临床评估和神经发育研究。

Abstract

Balanced steady-state free-precession (bSSFP) enables rapid fetal brain acquisition but suffers from inherently low tissue contrast. This study aims to develop an age-specific optimization strategy for bSSFP to enhance gray matter-white matter (GM-WM) contrast in the developing fetal brain. An optimization pipeline was designed for 2D and 3D bSSFP sequences, integrating the Transition Into Driven Equilibrium (TIDE) model with the extended phase graph (EPG) algorithm. Using T1 and T2 relaxation times measured from fetal brains, the pipeline derived age-specific variable flip angle (VFA) trains to maximize GM-WM contrast while constraining signal-to-noise ratio (SNR) and point-spread function. Performance was benchmarked against default bSSFP and T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) sequences based on relative contrast and segmentation accuracy. The contrast enhancement was evaluated in a cohort of 18 fetal brains from 24 to 37 gestational weeks. The optimized 2D and 3D bSSFP sequences yielded significantly higher relative cortical contrast compared with the default bSSFP (p < 0.001 for 2D and p < 0.002 for 3D), achieving average improvements of 4.13-fold and 4.06-fold, respectively. Furthermore, in the segmentation tasks, the optimized images yielded substantially higher segmentation accuracy compared with HASTE images (DICE = 0.93 for optimized 2D bSSFP and 0.89 for optimized 3D bSSFP, vs. 0.79 for HASTE). The proposed age-specific bSSFP optimization strategy enhanced the characterization of GM-WM contrast in fetuses of different gestational ages. This readily translatable method holds potential to advance both clinical assessments and neurodevelopmental studies of the fetal brain.

如何引用

AMA

Qinfeng Zhu, Xin Chen, Haotian Li, Xingwang Yong, Haoan Xu, Xinyi Xu, et al. Age-Specific Contrast Optimization of bSSFP in Fetal Brain.. Magnetic resonance in medicine. 2026; doi:10.1002/mrm.70452.

APA

Qinfeng Zhu, Xin Chen, Haotian Li, Xingwang Yong, Haoan Xu, Xinyi Xu, et al (2026). Age-Specific Contrast Optimization of bSSFP in Fetal Brain.. Magnetic resonance in medicine. https://doi.org/10.1002/mrm.70452

GB/T 7714

Qinfeng Zhu, Xin Chen, Haotian Li, Xingwang Yong, Haoan Xu, Xinyi Xu, et al. Age-Specific Contrast Optimization of bSSFP in Fetal Brain.[J]. Magnetic resonance in medicine, 2026 doi:10.1002/mrm.70452.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Magnetic resonance in medicine 的其他文献