用于三维金属孔测量的单目结构光传感

Monocular Structured-Light Sensing for 3D Metallic Hole Measurement.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

金属圆孔的非接触式计量检测对装配质量控制至关重要,但在反光机加工表面上仍然难以实现,因为在此类表面上深度尺度、条纹辐射度和轮廓几何会同时退化。纯单目二维视觉能够高效定位孔边界,但无法解析度量深度;多相机三维系统消除了这种歧义,但硬件和标定成本更高;而传统结构光流程通常孤立地改进条纹提取或圆拟合,当反射和边缘缺陷同时出现时,整体测量链仍然脆弱。本文提出一种单目结构光框架,将传感几何、辐射条纹可靠性和抗异常值的孔估计视为一个耦合的测量链。将单台经过标定的工业相机与倾斜投影的线激光相结合,融合俯视轮廓观测与光平面约束的深度恢复。多曝光高动态范围(HDR)融合、自适应高斯正则化和距离加权灰度质心细化,在局部饱和和不均匀光照下稳定亚像素条纹中心线;而几何感知的轮廓筛选和概率多阶段RANSAC拟合在圆参数估计过程中抑制毛刺引起的异常值。实验在钢制螺栓孔工件和包含五个标称直径约30–78 mm孔的6061铝合金板上进行。对原始钢制工件评估了其直径和两个与基准相关的中心位置量,而对五孔板通过三次重复光学直径测量和独立的CMM参考进行评估。对于五个铝合金孔,光学与CMM直径差的均值范围为0.006至0.218 mm,平均绝对差为0.096 mm。结果确立了在所测试工件和标定测量体积上的可行性,而非对任意孔几何、材料或表面条件的泛化。

Abstract

Non-contact metric inspection of metallic circular holes is essential for assembly quality control, yet remains difficult on reflective machined surfaces, where depth scale, stripe radiometry, and contour geometry degrade simultaneously. Pure monocular two-dimensional vision localizes hole boundaries efficiently but cannot resolve metric depth; multi-camera three-dimensional systems remove this ambiguity but with a heavier hardware and calibration cost; and conventional structured-light pipelines often improve stripe extraction or circle fitting in isolation, leaving the overall measurement chain fragile when reflection and edge defects co-occur. This paper proposes a monocular structured-light framework that treats sensing geometry, radiometric stripe reliability, and outlier-robust hole estimation as one coupled measurement chain. A single calibrated industrial camera is combined with an obliquely projected line laser to fuse top-view contour observation with light-plane-constrained depth recovery. Multi-exposure high-dynamic-range (HDR) fusion, adaptive Gaussian regularization, and distance-weighted gray-centroid refinement stabilize sub-pixel stripe centerlines under local saturation and uneven illumination, while geometry-aware contour screening and probabilistic multi-stage RANSAC fitting suppress burr-induced outliers during circle-parameter estimation. Experiments were conducted on a steel bolt-hole workpiece and a 6061 aluminum-alloy plate containing five holes with nominal diameters spanning approximately 30-78 mm. The original steel workpiece was evaluated for its diameter and two datum-related center-position quantities, while the five-hole plate was evaluated through three repeated optical diameter measurements and independent CMM references. For the five aluminum-alloy holes, the mean optical-CMM diameter differences ranged from 0.006 to 0.218 mm, with an average absolute difference of 0.096 mm. The results establish feasibility over the tested workpieces and calibrated measurement volume rather than generalization to arbitrary hole geometries, materials, or surface conditions.

如何引用

AMA

Zixuan Lv, Lijie Chen, Yu Tian, Xinyue Zhang, Jinliang Shao, Yinghao Liu, et al. Monocular Structured-Light Sensing for 3D Metallic Hole Measurement.. Sensors (Basel, Switzerland). 2026; doi:10.3390/s26154900.

APA

Zixuan Lv, Lijie Chen, Yu Tian, Xinyue Zhang, Jinliang Shao, Yinghao Liu, et al (2026). Monocular Structured-Light Sensing for 3D Metallic Hole Measurement.. Sensors (Basel, Switzerland). https://doi.org/10.3390/s26154900

GB/T 7714

Zixuan Lv, Lijie Chen, Yu Tian, Xinyue Zhang, Jinliang Shao, Yinghao Liu, et al. Monocular Structured-Light Sensing for 3D Metallic Hole Measurement.[J]. Sensors (Basel, Switzerland), 2026 doi:10.3390/s26154900.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Sensors (Basel, Switzerland) 的其他文献