微磁刺激的高频弱磁场检测和剂量校准:综述

High-Frequency Weak Magnetic-Field Detection and Dose Calibration for Micro-Magnetic Stimulation: A Review.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

亚毫米微线圈产生的高频弱磁场是微磁刺激(μMS)中与刺激剂量相关的关键物理参数。然而,其低幅值、高度局域化的近场分布、频率相关的探头响应以及对耦合变化的敏感性,使精确测量和剂量校准面临挑战。本综述总结了微线圈系统高频弱磁场检测技术的最新进展,讨论了关键测量难题,包括探头寄生效应、阻抗失配、相位失真、空间平均和动态失谐。现有方法分为直接磁场测量、共振增强检测与校准、空间场映射重建以及自适应补偿四类,并从频率范围、灵敏度、空间分辨率、系统复杂度和在线集成能力五个维度对这些方法进行了比较。本综述进一步强调了建立探测器输出、局部磁场与刺激剂量之间可靠且可溯源关系的必要性。未来方向包括宽带自适应测量、在线剂量校准、多通道磁场成像、多通道磁场分量解耦以及物理约束的数据驱动场估计。总体而言,本综述为微线圈磁场测量、刺激剂量标准化以及闭环神经调控微系统的定量框架提供了结构化概述。

Abstract

High-frequency weak magnetic fields generated by submillimeter micro-coils are key physical parameters associated with stimulation dose in micro-magnetic stimulation (μMS). However, their low amplitude, highly localized near-field distribution, frequency-dependent probe response, and sensitivity to coupling variations make accurate measurement and dose calibration challenging. This review summarizes recent advances in high-frequency weak magnetic-field detection techniques for micro-coil systems. It discusses key measurement challenges, including probe parasitics, impedance mismatch, phase distortion, spatial averaging, and dynamic detuning. Existing methods are classified into direct magnetic-field measurement, resonance-enhanced detection and calibration, spatial-field mapping reconstruction, and adaptive compensation. These methods are compared across five dimensions: frequency range, sensitivity, spatial resolution, system complexity, and online integration capability. The review further highlights the need to establish reliable and traceable relationships among detector outputs, local magnetic fields, and stimulation dose. Future directions include broadband adaptive measurement, online dose calibration, multichannel magnetic-field imaging, multichannel magnetic-field component decoupling, and physics-constrained data-driven field estimation. Overall, this review provides a structured overview of micro-coil magnetic-field measurement, stimulation dose standardization, and the quantitative frameworks for closed-loop neuromodulation microsystems.

如何引用

AMA

Lei Tian, Hang Tu, Jiahao Fei, Shuai Cao, Yongxiang Gao, Yameng Zhou, et al. High-Frequency Weak Magnetic-Field Detection and Dose Calibration for Micro-Magnetic Stimulation: A Review.. Sensors (Basel, Switzerland). 2026; doi:10.3390/s26154807.

APA

Lei Tian, Hang Tu, Jiahao Fei, Shuai Cao, Yongxiang Gao, Yameng Zhou, et al (2026). High-Frequency Weak Magnetic-Field Detection and Dose Calibration for Micro-Magnetic Stimulation: A Review.. Sensors (Basel, Switzerland). https://doi.org/10.3390/s26154807

GB/T 7714

Lei Tian, Hang Tu, Jiahao Fei, Shuai Cao, Yongxiang Gao, Yameng Zhou, et al. High-Frequency Weak Magnetic-Field Detection and Dose Calibration for Micro-Magnetic Stimulation: A Review.[J]. Sensors (Basel, Switzerland), 2026 doi:10.3390/s26154807.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Sensors (Basel, Switzerland) 的其他文献