一种用于同时监测红细胞聚集和粘度敏感时间常数的脉动流调制微流体传感器
A Pulsatile Flow-Modulation Microfluidic Sensor for Simultaneous Monitoring of Red Blood Cell Aggregation and Viscosity-Sensitive Time Constant.
A Pulsatile Flow-Modulation Microfluidic Sensor for Simultaneous Monitoring of Red Blood Cell Aggregation and Viscosity-Sensitive Time Constant.
红细胞(RBC)聚集和黏度相关的流动阻力是评估血流异常的重要血液流变学参数,但二者的同步测量通常需要多个泵或间歇性停流。本研究提出一种单注射泵微流体传感方法,用于在连续搏动性供血条件下同步评估RBC聚集和瞬态流动响应。该装置由单一入口、主直通道、分叉测试通道和大出口组成。通过在高流速(= 6 mL/h,持续2 min)与低流速(= 1 mL/h,持续4 min)之间周期性切换,施加优化的搏动性流型,并分析瞬态速度响应以提取时间常数(λ)作为黏度相关指标。经优化后,所选流型可在减少不必要血液消耗的同时,提供λ和RBC聚集指数(AI)的稳定且可重复的测量。λ与黏度呈强相关性,并显著受注射器空气顺应性影响。所提出的AI与传统聚集指数相比呈现一致的趋势。此外,其在连续血流下表现出时间稳定性。最后,该方法被用于检测连续输血过程中血液的时间依赖性变化,表明其作为一种简单、灵敏且实用的微流体传感器用于实时血液流变学监测的潜力。
Red blood cell (RBC) aggregation and viscosity-related flow resistance are important hemorheological parameters for assessing blood flow abnormalities, but their simultaneous measurement often requires multiple pumps or intermittent flow stoppage. In this study, we propose a single syringe pump microfluidic sensing method for simultaneous evaluation of RBC aggregation and transient flow response under continuous pulsatile blood delivery. The device consists of a single inlet, a main straight channel, a bifurcated test channel, and a big outlet. An optimized pulsatile-flow profile was applied by periodically switching the flow rate between high flow rate ( = 6 mL/h for 2 min) and low flow rate ( = 1 mL/h for 4 min), and the transient velocity response was analyzed to extract the time constant (λ) as a viscosity-related indicator. After optimization, the selected flow profile provides stable and reproducible measurements of both λ and the RBC aggregation index (AI) while reducing unnecessary blood consumption. The λ shows a strong correlation with viscosity and is significantly affected by syringe air compliance. The proposed AI exhibits consistent trends when compared with conventional aggregation indices. Furthermore, it exhibits temporal stability under continuous blood flow. Finally, the method is adopted to detect time-dependent changes in blood during continuous blood infusion, which demonstrates its potential as a simple, sensitive, and practical microfluidic sensor for real-time hemorheological monitoring.
Yang Jun Kang. A Pulsatile Flow-Modulation Microfluidic Sensor for Simultaneous Monitoring of Red Blood Cell Aggregation and Viscosity-Sensitive Time Constant.. Sensors (Basel, Switzerland). 2026; doi:10.3390/s26144541.
Yang Jun Kang (2026). A Pulsatile Flow-Modulation Microfluidic Sensor for Simultaneous Monitoring of Red Blood Cell Aggregation and Viscosity-Sensitive Time Constant.. Sensors (Basel, Switzerland). https://doi.org/10.3390/s26144541
Yang Jun Kang. A Pulsatile Flow-Modulation Microfluidic Sensor for Simultaneous Monitoring of Red Blood Cell Aggregation and Viscosity-Sensitive Time Constant.[J]. Sensors (Basel, Switzerland), 2026 doi:10.3390/s26144541.