超高功率短时射频消融损伤的多导管比较

Multicatheter Comparison of Very High-Power Short-Duration Radiofrequency Ablation Lesions.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

极高效短时程(vHPSD)射频消融(RFA)是肺静脉隔离的一种替代策略。然而,温度的快速升高可能导致并发症。QDOT Micro 旨在检测温度升高以自动调节功率和灌注流量。我们比较了三种 RFA 导管在消融电极设计上的差异对 vHPSD 消融灶的影响。vHPSD RFA 在经验证的凝胶槽模型中进行。使用 QDOT、SmartTouch 和 TactiFlex SE 在 60、70、80 和 90 瓦下以稳定的接触力进行 4 秒消融,分别垂直于(90°)、斜交于(45°)和平行于(0°)消融靶点放置,并使用 0.9% 和 0.45%“半正常”盐水(HNS)灌注。SmartTouch 和 TactiFlex 以功率控制模式运行,每种配置重复三次,每秒采集图像以表征消融灶。共实施 216 个 vHPSD 消融灶。在 90 W、90° 和 0.9% 盐水条件下,QDOT 产生的消融灶平均深度为 1.93 mm。TactiFlex 产生的消融灶较浅,平均深度为 1.88 mm(p = 0.02),SmartTouch 产生的消融灶最深,平均深度为 2.37 mm(p < 0.001)。QDOT 消融灶的平均直径为 4.63 mm,与 TactiFlex 消融灶(4.58 mm,p = 0.8)相当,而 SmartTouch 消融灶显著宽于 QDOT 和 TactiFlex(6.04 mm,p < 0.001)。基于消融灶温度的蒸汽爆裂风险以 TactiFlex 最低。在受控条件下,使用 QDOT 产生的 vHPSD 消融灶在尺寸和温度上均大于 TactiFlex 所产生的消融灶,提示消融电极冷却特性的差异。使用 SmartTouch 或 0.45% HNS 进行 vHPSD 可能增加蒸汽爆裂的风险。

Abstract

Very high-power short-duration (vHPSD) radiofrequency ablation (RFA) is an alternative strategy for pulmonary vein isolation. However, rapid temperature rises may cause complications. The QDOT Micro is designed to detect temperature rises for automatic power and irrigation flow adjustments. We compared how differences in ablation electrode design between three RFA catheters impact vHPSD lesions. vHPSD RFA was performed within a validated gel tank model. Four-second ablations were delivered with stable contact force using the QDOT, SmartTouch, and TactiFlex SE at 60, 70, 80, and 90 watts, positioned perpendicular (90°), oblique (45°), and parallel (0°) to the ablation target, utilizing 0.9% and 0.45% "half-normal" saline (HNS) irrigation. The SmartTouch and TactiFlex were operated in power-controlled mode, and each configuration was repeated three times, with images captured every second to characterize lesions. In total, 216 vHPSD lesions were delivered. At 90 W, 90°, and 0.9% saline, the QDOT produced lesions with a mean depth of 1.93 mm. The TactiFlex produced shallower lesions, with a mean depth of 1.88 mm (p = 0.02), and the SmartTouch produced the deepest, with a mean depth of 2.37 mm (p < 0.001). The mean diameter of QDOT lesions, at 4.63 mm, was comparable to TactiFlex lesions (4.58 mm, p = 0.8), whilst the SmartTouch lesions were significantly wider than both the QDOT and TactiFlex (6.04 mm, p < 0.001). Steam-pop risk, based on lesion temperature, was lowest for the TactiFlex. vHPSD lesions produced with the QDOT achieved greater dimensions and temperatures than those with the TactiFlex under controlled conditions, suggesting a difference in the cooling profile of the ablation electrodes. vHPSD with the SmartTouch or 0.45% HNS are likely to increase the risk of steam pops.

如何引用

AMA

Samual Turnbull, Michael A Barry, Timothy G Campbell, Kasun De Silva, Ashwin Bhaskaran, Pierre Qian, et al. Multicatheter Comparison of Very High-Power Short-Duration Radiofrequency Ablation Lesions.. Journal of cardiovascular electrophysiology. 2026; doi:10.1111/jce.70421.

APA

Samual Turnbull, Michael A Barry, Timothy G Campbell, Kasun De Silva, Ashwin Bhaskaran, Pierre Qian, et al (2026). Multicatheter Comparison of Very High-Power Short-Duration Radiofrequency Ablation Lesions.. Journal of cardiovascular electrophysiology. https://doi.org/10.1111/jce.70421

GB/T 7714

Samual Turnbull, Michael A Barry, Timothy G Campbell, Kasun De Silva, Ashwin Bhaskaran, Pierre Qian, et al. Multicatheter Comparison of Very High-Power Short-Duration Radiofrequency Ablation Lesions.[J]. Journal of cardiovascular electrophysiology, 2026 doi:10.1111/jce.70421.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of cardiovascular electrophysiology 的其他文献