使用机器人磁导航导管消融特发性室性早搏:丰富经验与综述

Catheter Ablation of Idiopathic Premature Ventricular Contractions Using Robotic Magnetic Navigation: Extensive Experience and Review.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

这项针对我们丰富经验的回顾性分析聚焦于机器人磁导航(RMN)引导下的特发性室性早搏(PVC)消融,并对急性手术失败的原因及影响进行了批判性评估。本回顾性队列研究纳入824例首次接受RMN引导下PVC消融的患者(平均PVC负荷21.0±6.6%)。急性失败定义为最后一次射频(RF)应用后观察期内临床PVC复发。导航指数计算为射频放电时间与总消融时间的比值。采用多因素logistic回归从患者人口学特征、PVC特征及手术参数中筛选急性失败的影响因素。平均手术时间和透视时间分别为73.8±38.3分钟和2.6±2.9分钟。总体急性手术失败率为11%(90/824)。急性手术失败强烈依赖于PVC起源:右心室流出道最低(2.7%),左心室顶部最高(44%)。主要机制确定为壁内起源(50%,45/90)和邻近高危结构(24%,22/90)。多因素分析确定PVC起源和导航指数(OR=0.1,95%CI 0.05-0.20;p<0.001)为失败的独立预测因素。较高的导航指数反映更高的手术效率,与手术成功相关。未发生重大并发症,0.6%的患者观察到轻微并发症。RMN引导下的特发性PVC消融表现出优异的安全性和相对较低的急性手术失败率。手术结局关键取决于PVC的解剖起源以及由导航指数衡量的手术效率。

Abstract

This retrospective analysis of our extensive experience focuses on idiopathic premature ventricular contractions (PVC) ablation guided by robotic magnetic navigation (RMN). Critical evaluation is given to the causes and impact of acute procedural failure. This retrospective cohort study enrolled 824 patients (mean PVC burden 21.0 ± 6.6%) undergoing first-time RMN-guided PVC ablation. Acute failure was defined as recurrent clinical PVC during the observation period after the last radiofrequency (RF) application. The Navigation Index was calculated as the ratio of RF delivery time to total ablation time. Multivariate logistic regression was used to detect the impact factors of acute failure from patient demographics, PVC characteristics, and procedural parameters. The mean procedure and fluoroscopic times were 73.8 ± 38.3 and 2.6 ± 2.9 min, respectively. The overall acute procedural failure rate was 11% (90/824). Acute procedure failure was strongly dependent on the PVC origin: lowest in the right ventricular outflow tract (2.7%) and highest in the left ventricular summit (44%). The primary mechanisms were determined to be intramural origins (50%, 45/90) and proximity to high-risk structures (24%, 22/90). Multivariate analysis identified PVC origin and Navigation Index (OR = 0.1, 95% CI 0.05-0.20; p < 0.001) as independent predictors of failure. A higher Navigation Index, reflecting greater procedural efficiency, correlated with procedural success. No major complications occurred, and minor complications were observed in 0.6% of patients. RMN-guided idiopathic PVC ablation demonstrated excellent safety and a relatively low acute procedural failure rate. Procedural outcomes are critically determined by the anatomical origin of the PVC and the procedural efficiency measured by the Navigation Index.

如何引用

AMA

Qingzhi Luo, Xiang Li, Peng Zhang, Zhuhui Liu, Yun Xie, Yangyang Bao, et al. Catheter Ablation of Idiopathic Premature Ventricular Contractions Using Robotic Magnetic Navigation: Extensive Experience and Review.. Journal of cardiovascular electrophysiology. 2026; doi:10.1111/jce.70446.

APA

Qingzhi Luo, Xiang Li, Peng Zhang, Zhuhui Liu, Yun Xie, Yangyang Bao, et al (2026). Catheter Ablation of Idiopathic Premature Ventricular Contractions Using Robotic Magnetic Navigation: Extensive Experience and Review.. Journal of cardiovascular electrophysiology. https://doi.org/10.1111/jce.70446

GB/T 7714

Qingzhi Luo, Xiang Li, Peng Zhang, Zhuhui Liu, Yun Xie, Yangyang Bao, et al. Catheter Ablation of Idiopathic Premature Ventricular Contractions Using Robotic Magnetic Navigation: Extensive Experience and Review.[J]. Journal of cardiovascular electrophysiology, 2026 doi:10.1111/jce.70446.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of cardiovascular electrophysiology 的其他文献