胃肠系统肿瘤的深度学习重建双能计算机断层扫描:低千电子伏成像与常规成像

Deep learning reconstruction dual-energy computed tomography for gastrointestinal system tumors: low-kiloelectron volt imaging vs routine imaging.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

本前瞻性观察性研究旨在定性及定量比较深度学习图像重建(DLIR)生成的55 keV双能计算机断层扫描(DECT)虚拟单能图像(VMI)与自适应统计迭代重建(ASiR-V)生成的70 keV VMI在胃肠道系统肿瘤中的应用,并探讨DLIR是否会影响测量的碘参数。研究纳入47例接受DECT检查的胃肠道系统肿瘤患者。对采用ASiR-V40%的70 keV VMI以及采用低强度(DLIR-L)、中强度(DLIR-M)和高强度(DLIR-H)DLIR的55 keV VMI进行定性和定量评估。定量评估包括计算对比噪声比(CNR)和信噪比(SNR)。由2名放射科医师对整体图像质量、病灶清晰度和诊断信心进行定性评估。比较四组算法间肿瘤病灶的碘参数。DLIR-M与ASiR-V40%之间的图像噪声无显著差异,而DLIR-H的图像噪声显著低于ASiR-V40%和DLIR-M(两期均P < 0.001)。在两期中,DLIR-M和DLIR-H的CNR和SNR均显著高于ASiR-V40%(均P ≤ 0.001)。与ASiR-V40%相比,DLIR-M和DLIR-H的定性评估指标相似或有所改善。在这些算法中,DLIR-L的图像噪声最高,整体图像质量评分最低。最后,不同算法间测量的碘参数相当(均P > 0.1)。采用DLIR(-M和-H)的55 keV腹部DECT在胃肠道肿瘤评估中的定性和定量性能与70 keV下ASiR-V 40%相当或更优。

Abstract

To qualitatively and quantitatively compare dual-energy computed tomography (DECT)-derived 55 keV virtual monochromatic images (VMIs) using deep learning image reconstruction (DLIR) with 70 keV VMIs using adaptive statistical iterative reconstruction (ASiR-V) in the Gastrointestinal (GI) system tumors and to investigate whether DLIR can influence the measured iodine parameters. This prospective, observational study included 47 patients with GI system tumors who underwent DECT. Qualitative and quantitative assessment was performed on 70 keV VMIs using ASiR-V40%, and 55 keV VMIs using DLIR at low (DLIR-L), medium (DLIR-M), and high strength (DLIR-H). Quantitative evaluation included calculation of the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR). Overall image quality, lesion conspicuity, and diagnostic confidence were evaluated qualitatively by 2 radiologists. Iodine parameters of tumor lesions were compared among four groups of algorithms. There were no significant differences in the image noise between DLIR-M and ASiR-V40%, whereas image noise was significantly lower in DLIR-H than ASiR-V40% and DLIR-M (both phases, P < 0.001). DLIR-M and DLIR-H had significantly higher CNR and SNR compared with ASiR-V40% on both phases (all P ≤ 0.001). When compared to ASiR-V40%, DLIR-M and DLIR-H had similar or improved qualitative assessment metrics. DLIR-L yielded the highest image noise and the lowest overall image quality score among these algorithms. Lastly, the measured iodine parameters were equivalent among different algorithms (all P > 0.1). Abdominal DECT at 55 keV with DLIR (-M and -H) provided qualitative and quantitative performance for GI tumor evaluation comparable to or exceeding that of ASiR-V 40% at 70 keV.

如何引用

AMA

Y Liu, M Yuan, H Liang, Y You, J Li, L Chen, et al. Deep learning reconstruction dual-energy computed tomography for gastrointestinal system tumors: low-kiloelectron volt imaging vs routine imaging.. Clinical radiology. 2026; doi:10.1016/j.crad.2026.107403.

APA

Y Liu, M Yuan, H Liang, Y You, J Li, L Chen, et al (2026). Deep learning reconstruction dual-energy computed tomography for gastrointestinal system tumors: low-kiloelectron volt imaging vs routine imaging.. Clinical radiology. https://doi.org/10.1016/j.crad.2026.107403

GB/T 7714

Y Liu, M Yuan, H Liang, Y You, J Li, L Chen, et al. Deep learning reconstruction dual-energy computed tomography for gastrointestinal system tumors: low-kiloelectron volt imaging vs routine imaging.[J]. Clinical radiology, 2026 doi:10.1016/j.crad.2026.107403.