优化儿科患者的胸部计算机断层扫描(CT)范围,以减少辐射暴露

Optimising chest computed tomography (CT) scan ranges in paediatric patients to reduce radiation exposure.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

本研究旨在通过明确扫描上下边界范围,为儿科患者无增强胸部计算机断层扫描(CT)精确设定扫描范围,以满足临床需求的同时将辐射风险降至最低。本两队列研究纳入3174名接受无增强胸部CT扫描的儿童(年龄3~14岁)。队列1(n=1894)用于回顾性分析肺边界变异性以确定最佳扫描范围,队列2(n=1280)用于验证与传统方案相比,该方案在界定肺边界和降低辐射剂量方面的准确性。传统方案:上肺边界位于第一肋上缘;下边界位于膈肌下方(取决于技师),覆盖肺尖至肺底。精确方案:上边界与第一肋对齐(偏移0 mm);下边界位于肋膈角下方35 mm(3~6岁)或40 mm(7~14岁)。辐射剂量计算:有效剂量(ED)由剂量长度乘积(DLP)采用年龄特异性转换系数(k=0.018 mSv·mGy·cm)推算得出。扫描范围优化使z轴覆盖范围减少4.7%(3~6岁)和6.1%(7~14岁)。采用优化方案时,上下边界遗漏肺实质的概率均<5%。辐射剂量降低情况如下:3~6岁:ED降低19.2%(0.09 mSv),DLP降低17.7%(4.5 mGycm);7~14岁:ED降低17.0%(0.21 mSv),DLP降低17.0%(11.7 mGycm)。所提出的方案实现了精确的肺覆盖,同时将辐射暴露降低17%~19%。该策略兼顾了诊断质量与患者安全,为儿科无增强胸部CT成像提供了一种可推广的解决方案。未来的多中心验证和人工智能(AI)驱动的自动化可进一步提高临床采用率。

Abstract

The aim of this study was to accurately position the scan range of unenhanced chest computed tomography (CT) scans for paediatric patients by clarifying the upper and lower scan boundary ranges to meet clinical needs while minimising radiation risks. This two-cohort study included 3174 children (aged 3-14 years) undergoing unenhanced chest CT scans. Cohort 1 (n=1894) was used to retrospectively analyse lung boundary variability to determine optimal scan ranges, while cohort 2 (n=1,280) was used to validate the accuracy in delineating lung boundaries and reducing radiation dose compared with traditional protocols. Traditional protocol: upper lung border at the first rib's upper edge; lower border below the diaphragm (technician dependent), covering apex to base. Precise protocol: upper border aligns with the first rib (0 mm offset); lower border 35 mm (3-6 years) or 40 mm (7-14 years) below costophrenic angle. Radiation dose calculation: effective dose (ED) derived from dose-length product (DLP) using age-specific conversion coefficients (k = 0.018 mSv·mGy·cm). Scan range optimisation reduced z-axis coverage by 4.7% (3-6 years) and 6.1% (7-14 years). The probability of missed lung parenchyma was <5% for both upper and lower boundaries using the optimised protocol. Radiation dose reductions were as follows: 3-6 year: ED decreased by 19.2% (0.09 mSv) and DLP by 17.7% (4.5 mGycm); 7-14 years: ED decreased by 17.0% (0.21 mSv) and DLP by 17.0% (11.7 mGycm). The proposed protocol achieves precise lung coverage while reducing radiation exposure by 17-19%. This strategy balances diagnostic quality and patient safety, offering a scalable solution for paediatric unenhanced chest CT imaging. Future multicentre validation and artificial intelligence (AI)-driven automation could further enhance clinical adoption.

如何引用

AMA

F Yang, X Wang, H Cai, H Li, H Liu, Y Zhao. Optimising chest computed tomography (CT) scan ranges in paediatric patients to reduce radiation exposure.. Clinical radiology. 2026; doi:10.1016/j.crad.2026.107420.

APA

F Yang, X Wang, H Cai, H Li, H Liu, Y Zhao (2026). Optimising chest computed tomography (CT) scan ranges in paediatric patients to reduce radiation exposure.. Clinical radiology. https://doi.org/10.1016/j.crad.2026.107420

GB/T 7714

F Yang, X Wang, H Cai, H Li, H Liu, Y Zhao. Optimising chest computed tomography (CT) scan ranges in paediatric patients to reduce radiation exposure.[J]. Clinical radiology, 2026 doi:10.1016/j.crad.2026.107420.