CLINICAL RADIOLOGY临床放射学
CLINICAL RADIOLOGY(英文缩写 CLIN RADIOL),ISSN 0009-9260,eISSN 1365-229X,中文译名:临床放射学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 3.389 | Q2 |
| 2022 | 2.600 | Q3 |
| 2023 | 2.100 | Q2 |
| 2024 | 1.900 | Q3 |
| 2025 | 2.000 | Q3 |
CLINICAL RADIOLOGY 最新收录文献
-
1. Abbreviated magnetic resonance (MR) enterography for Crohn's disease: is intravenous contrast enhancement always necessary?
1. 克罗恩病的简化磁共振小肠造影:是否总是需要静脉对比增强?PMID:日期:2026-09-05The aim of the study is to evaluate the diagnostic performance and noninferiority of an abbreviated, nonintravenous contrast-enhanced magnetic resonance enterography (MRE) protocol compared with a standard gadolinium-enhanced protocol for the assessment of Crohn's disease activity, extent and complications. This retrospective, single-centre study included 50 consecutive patients (mean age 42.7 ± 16.9 years) with suspected or established Crohn's disease who underwent standard MRE. Two radiologists, blinded to clinical data and reference reports, independently evaluated abbreviated protocol sequences (balanced turbo field echo [BTFE], T2-weighted spectral attenuated inversion recovery [SPAIR] and turbo spin echo [TSE], diffusion-weighted imaging [DWI]/apparent diffusion coefficient [ADC]). Diagnostic performance was assessed against the report as the reference standard. Interobserver agreement for categorical variables was analysed using Cohen's and Fleiss' kappa coefficients, while continuous variables were evaluated using intraclass correlation coefficients (ICCs), with 95% confidence intervals. Bland-Altman analysis was performed. Agreement for disease activity was almost perfect (κ = 0.83, 95% confidence interval [CI]: 0.64-0.96). (Reader A: sensitivity 93.5% (95% CI: 78.6-99.2), specificity 84.2% (60.4-96.6); reader B: sensitivity 90.3% (74.2-98.0), specificity 94.7% (74.0-99.9)). Agreement for anatomical location was also almost perfect. Substantial agreement was observed for stenosis detection (κ from 0.66 (95% CI: 0.29-0.89) to 0.73 (0.44-0.92)), whereas agreement for ulceration and penetrating complications was lower and heterogeneous. Quantitative measurements demonstrated excellent reproducibility (ICC > 0.87, 95% CI: 0.79-0.93). The abbreviated, nonintravenous contrast-enhanced MRE protocol demonstrates noninferior diagnostic performance for the evaluation of disease activity, extent and stenosis in Crohn's disease. Its implementation may reduce examination time and contrast exposure, although contrast-enhanced imaging remains indicated for the assessment of ulcerations and penetrating complications.
-
2. Interhemispheric diffusion tensor imaging analysis along the perivascular space (DTI-ALPS) differences and correlations with age.
2. 半球间沿血管周围间隙的扩散张量成像分析(DTI-ALPS)差异及其与年龄的相关性PMID:日期:2026-09-01该文献暂无摘要。
-
4. Imaging diagnostic value of 1-hour delayed Gadolinium-DTPA enhanced three-dimensional (3D) T1 SPACE magnetic resonance images (MRI) in Ramsay Hunt syndrome.
4. 1小时延迟钆-DTPA增强三维(3D)T1 SPACE磁共振成像(MRI)在Ramsay Hunt综合征中的影像诊断价值PMID:日期:2026-08-29This study aimed to evaluate the diagnostic value of 1-hour gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA)-enhanced three-dimensional (3D) T1-weighted sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) magnetic resonance images (MRI) in Ramsay Hunt syndrome (RHS). Patients diagnosed with RHS between January 2021 and January 2023 were retrospectively enrolled. Routine and 1-hour-delayed gadolinium-DTPA-enhanced 3D T1 SPACE MR images were retrospectively analysed. Signal-intensity ratios of the facial nerve to that of the adenohypophysis were calculated. The degree of enhancement of the affected segments of the facial nerve on 1-hour-delayed contrast-enhanced magnetic resonance imaging (MRI) was significantly higher than that on routine contrast-enhanced MRI. Enhancement of the distal facial nerve segments, vestibulocochlear nerve, and cochlea was also observed. Meanwhile, in patients with concurrent meningitis, we observed marked enhancement of the cisternal segment of the facial nerve. The signal-intensity ratio on the affected side was higher than that on the unaffected side in the labyrinthian and geniculate ganglion segments on both routine and 1-hour-delayed contrast-enhanced MRI. Additionally, the signal-intensity ratios of the affected labyrinthine and geniculate ganglion segments were higher on 1-hour-delayed contrast-enhanced MRI than on routine contrast-enhanced MRI. Compared with routine contrast-enhanced MRI, 1-hour-delayed contrast-enhanced MRI provides improved visualisation of facial nerve enhancement. Our findings suggest that 1-hour-delayed contrast-enhanced MRI may facilitate the detection of imaging findings associated with early central nervous system (CNS) involvement in patients with RHS complicated by meningitis.
-
5. Prospective study to evaluate radiation dose and image quality in two-dimensional (2D) lower limb angiographic images acquired with a novel contrast-to-noise ratio (CNR)-driven exposure control protocol.
5. 评估使用新型对比噪声比驱动的曝光控制方案获取的二维下肢血管造影图像的辐射剂量和图像质量的前瞻性研究PMID:日期:2026-08-27Radiation exposure during peripheral vascular intervention poses potential deterministic and stochastic risks in the long run to patients and operators. Thus, it is important to optimise radiation dose without compromising on image quality. OPTIQ, a novel contrast-to-noise ratio (CNR)-driven exposure control, is prospectively evaluated against conventional dose protocol (CDP) to determine differences in radiation dose and image quality. Forty lower limb angioplasty cases between April 2023 and March 2025 were randomly assigned to either CDP or OPTIQ protocol for prospective evaluation. Primary outcomes included radiation dose measured by dose-area product (DAP) and air kerma (AK) for patients and scattered radiation exposure for operators using real-time dosimeters. Secondary outcomes assessed subjective image quality using 5-point Likert scales for contrast, brightness, sharpness, and device visualisation. Patient demographics were comparable between groups. OPTIQ demonstrated significant radiation dose reduction compared to CDP: total DAP (412.8 ± 318.2 vs 1,284.5 ± 841.2 μGym, P<0.001), two-dimensional (2D) angiography DAP (132.0 ± 92.5 vs 1,059.3 ± 640.4 μGym, P<0.001), and total AK (19.9 ± 16.9 vs 55.0 ± 45.3 mGy, P<0.005). Total radiation dose reduced by approximately 60% with OPTIQ. Operator radiation exposure was lower with OPTIQ (0.138 ± 0.135 vs 0.362 ± 0.632 μSv/sec, P=0.288), though not statistically significant. Subjective image quality assessments showed no significant differences between protocols across all parameters (P>0.05), with both protocols providing diagnostically acceptable images. The adoption of OPTIQ protocol can bring about radiation-dose reduction for both patients and healthcare workers during lower limb angioplasty without compromising diagnostic image quality, which is in line with As Low As Reasonably Achievable (ALARA) principles.
-
6. Distinguishing focal nodular hyperplasia from hepatocellular adenoma on contrast-enhanced ultrasound: a systematic review and meta-analysis.
PMID:日期:2026-08-26Single-centre studies with modest sized samples have shown that contrast-enhanced ultrasound (CEUS) can distinguish focal nodular hyperplasia (FNH) from hepatocellular adenomas (HCAs). We performed a systematic review and meta-analysis to evaluate the diagnostic performance of CEUS in distinguishing FNH from HCA. PubMed, Embase, and Web of Science were searched up to January 2026 for studies that evaluated FNHs and HCAs using CEUS, with histopathology or magnetic resonance imaging (MRI) with hepatobiliary contrast agent as the reference standard. The diagnostic performance of CEUS from individual studies was extracted. Pooled sensitivity and specificity with 95% confidence interval (CI) were obtained using a bivariate random-effects model. A summary receiver-operating characteristic curve (SROC) was generated to estimate the area under the curve (AUC) via parametric bootstrapping. Five scientific studies were included, with a total of 228 FNHs and 155 HCAs. Final diagnoses were established by histology alone in one study and by MRI with hepatobiliary contrast in four studies. Three of the five studies were at overall low risk of bias, with concerns mainly related to patient selection. The pooled sensitivity and specificity of CEUS to differentiate FNH from HCA were 84.9% (95% CI, 69.8-93.2%) and 84.1% (95% CI, 74.8-90.4%), respectively. The AUC was 0.90 (95% CI, 0.80-0.93). CEUS showed promising diagnostic performance for distinguishing FNH from HCA. However, given the small number of studies and the predominant use of MRI with hepatobiliary contrast rather than histology as the reference standard, these findings should be considered exploratory.
-
7. Performance of ChatGPT (GPT-4o) in automated Lung-Reporting and Data Systems (RADS) classification: a category-stratified evaluation of prompting strategies.
7. ChatGPT(GPT-4o)在自动化肺部报告和数据系统(RADS)分类中的表现:一种按类别分层的提示策略评估PMID:日期:2026-08-26The aim of this study is to explore the capabilities of large language models (LLMs), such as ChatGPT, in assigning Lung-Reporting and Data Systems (RADS) scores when given radiology report findings, and to explore prompt engineering practices for efficient and effective integration of artificial intelligence (AI) into radiology workflows. A total of 327 de-identified low-dose lung screening computed tomography (CT) reports were evaluated using GPT- 4o, with instructions to assign Lung-RADS scores based on the reports provided. Structured and unstructured zero-shot prompting strategies were tested. Accuracy, overcalls, undercalls, and weighted Cohen's kappa (linear weights) were computed for each prompt type compared with the rater. McNemar's test was used to compare accuracy between structured and unstructured prompts. Agreement between GPT outputs and the rater's reference standard was higher for the structured prompt compared with the unstructured prompt. For the structured prompt, overall accuracy was 68.8% with a weighted Cohen's kappa of 0.758, while the unstructured prompt achieved an accuracy of 58.1% and a weighted Cohen's kappa of 0.695. Structured prompting produced fewer overcalls and more undercalls compared with unstructured prompting. LLMs demonstrate promise in automatically assigning scores to screening imaging studies when provided with findings and can potentially be incorporated into reporting workflows to improve reporting efficiency.
-
8. Development and validation of a model combining bowel ultrasound and inflammatory biomarkers for evaluating disease activity in ulcerative colitis: a dual centre retrospective study.
PMID:日期:2026-08-26This study evaluated the diagnostic accuracy of bowel ultrasound combined with inflammatory biomarkers for assessing ulcerative colitis disease activity. The single-centre derivation cohort retrospectively enrolled 60 patients with ulcerative colitis from our institution who underwent colonoscopy and bowel ultrasound. Patients were stratified into active disease and remission groups. Bowel ultrasound parameters and clinical features were analysed. Diagnostic performance was assessed using receiver operating characteristic curve analysis. The resulting model was externally validated from 35 patients at an independent tertiary hospital retrospectively. A nomogram was plotted for clinical application. In the derivation cohort (31 remission: age 42.6 ± 18.3 years, male 48%; 29 active: age 44.4 ± 14.5 years, male 48%), univariate analysis identified bowel wall thickness (cutoff value 3.95 mm), submucosal index (cutoff value 46.1%), bowel wall flow (cutoff value grade 2), faecal calprotectin (cutoff value ≥ 200 μg/g), and erythrocyte sedimentation rate (cutoff value 26.5 mm/h) as significant predictors of disease activity. Bowel wall thickness and flow were independent risk factors. The combined model demonstrated an area under the curve of 0.908 (95% CI 0.829-0.986). External validation (19 remission and 16 active) provided preliminary evidence supporting the model's discriminative ability, showing an area under the curve of 0.862 (95% CI 0.743-0.981). The nomogram provided individualised risk prediction with acceptable calibration in both cohorts. An integrated model combining bowel ultrasound and inflammatory biomarkers was developed and externally validated for the assessment of ulcerative colitis activity. The model, presented as a clinically practical nomogram, exhibits acceptable calibration, supporting its potential as a valuable noninvasive tool for patient management.
-
9. A formal neuroradiology second opinion service changes management in one in five cases: a retrospective cohort study of discrepancies and types of errors.
PMID:日期:2026-08-25To quantify discrepancy rates between referring reports and subspecialist neuroradiology second-opinion reports in a UK tertiary neuro centre, describe the clinical impact of the service, and classify discrepancies using the Kim-Mansfield modification of the Renfrew error taxonomy. Retrospective review of consecutive formal neuroradiology second opinion reports over 12 months (April 2024 to March 2025) at a tertiary neuro centre. Agreement between referring reports and second-opinion reports was classified into: major discrepancy, minor discrepancy, or complete agreement. Discrepancies were further categorised by error type using the Kim-Mansfield classification. A total of 580 studies were reviewed (magnetic resonance imaging [MRI]: 487/580, 84%; computed tomography [CT]: 93/580, 16%). The overall discrepancy rate was 42.2% (245/580), including 21.4% major discrepancies (124/580) and 20.9% minor discrepancies (121/580). Vascular studies were the commonest major discrepancies (61/124, 49.2%). Error typing across all discrepancies demonstrated predominantly cognitive/interpretive categories: faulty reasoning was the most frequent (109/245, 44.5%), followed by complacency (54/245, 22.0%), underreading (37/245, 15.1%), and satisfaction of search (28/245, 11.4%). In major discrepancies, faulty reasoning remained the most common (53/124, 42.7%), followed by complacency (34/124, 27.4%) and underreading (26/124, 21%). Major discrepancies were associated with high clinical impact, including a change in diagnosis (123/124, 99.2%), a change in treatment (116/124, 93.5%), and a change in investigation change (85/124, 68.5%). Subspecialist neuroradiology second-opinion reporting identified discrepancies in over two-fifths of cases, including management-altering discrepancies in approximately one in five. Faulty reasoning was the dominant error type, supporting targeted quality improvement interventions focused on interpretive/cognitive pitfalls.
-
10. Single-slice quantitative magnetic resonance imaging (MRI) of the thigh for differential assessment of fasting-related body composition changes.
10. 大腿单层定量磁共振成像(MRI)用于空腹相关身体成分变化的鉴别评估PMID:日期:2026-08-22The aim of this study was to assess the ability of single-slice quantitative thigh magnetic resonance imaging (MRI) to estimate whole-body (wb) composition and to detect fasting-related changes, providing potential surrogate markers. This prospective substudy is based on a previously published randomised clinical trial with 66 non-obese participants in three matched intervention groups: control (n=20), alternate-day fasting (n=23), and time-restricted feeding (n=23). Body composition (BC) analysis was performed before and after a month-long intervention with wbMRI, multi-echo Dixon thigh MRI and bioimpedance analysis (BIA). Thigh compartments were manually segmented on a single slice of the fat fraction (FF) map, including muscle area (MA) and intermuscular adipose tissue (IMAT) of extensor and flexor compartments, respectively. Relationships between thigh MRI, wbMRI, and BIA were modelled with simple linear regressions and sandwich estimators. Effects of fasting regimens on thigh measurements compared to the control group were evaluated with analysis of covariance. Extensor more than flexor MA was a strong predictor of wb muscle mass in wbMRI and BIA (R = 0.77 and 0.72, respectively). The ability of thigh FF and IMAT to estimate visceral fat volume was weak to moderate (R = 0.15 to 0.43). Fasting regimens did not demonstrate statistically significant changes of MA, FF, or IMAT in the extensor or flexor thigh compartment, compared to the control group (all P≥0.45). Our results suggest that single-slice thigh MRI can generally predict wb muscle mass and also visceral fat to a lesser degree. No fasting-related changes of tissue composition were detected, although certain trends were observed.