Optics Continuum光学连续体
Optics Continuum(英文缩写 OPT CONTINUUM),ISSN 2770-0208,eISSN 2770-0208,中文译名:光学连续体 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2022 | 未收录 | N/A |
| 2023 | 1.100 | Q4 |
| 2024 | 1.400 | Q3 |
| 2025 | 1.500 | Q3 |
Optics Continuum 最新收录文献
-
1. Size estimation of mixed free-floating sub-resolution spherical scatterers utilizing adaptive scanning optical coherence tomography.
PMID:日期:2026-06-24Optical coherence tomography (OCT) is a volumetric imaging technique that enables real-time assessment of biological tissues with micrometer-scale resolution. This enables OCT to also offer the potential to estimate scatterer size. However, in cases where the axial and lateral resolution of the OCT system are larger than the target scatterer, it is difficult to assess the scatterer size directly within the OCT space domain. This paper presents a workflow to estimate diameters of individual free-floating spherical particles within OCT volumes, leveraging adaptive scanning, spectroscopic OCT, and Mie theory. Using this workflow, we demonstrate the capability to estimate individual microbead diameters ranging from 6 to 10 μm, both in isolation and within mixed solutions with 12 × speed up than the previous method. The results indicate that the proposed Mie backscattering approach yields size estimations that were statistically equivalent to labeled values. In experiments with a mixed solution containing microbeads of 6 μm, 8 μm, and 10 μm diameters, our method successfully differentiated the three bead sizes through histogram analysis.
-
2. High-speed in vivo calcium recording using structured illumination with self-supervised denoising.
PMID:日期:2024-10-31High-speed widefield fluorescence imaging of neural activity in vivo is fundamentally limited by fluctuations in recorded signal due to background contamination and stochastic noise. In this study, we show background and shot noise-reduced imaging of the ultrafast genetically encoded Ca indicator GCaMP8f in CA1 pyramidal neurons using periodic structured illumination (SI) with computational image reconstruction. We implement what we believe to be a novel reconstruction method for data acquired using periodic structured illumination, termed pseudo-HiLo (pHiLo), that combines a pseudo-widefield (pWF) reconstruction with individual SI frames to perform a HiLo reconstruction. We compare this new technique to interleaved optical sectioning structured illumination microscopy (OS-SIM) and pWF reconstruction. We quantify the performance of each reconstruction by evaluating contrast, transient peak-to-noise ratio (PNR), pairwise correlation coefficients between ΔF/F time courses extracted from individual in-focus cells, and correlation coefficients between each cell with surrounding cell-free background pixels. We additionally incorporate a self-supervised deep learning method for real-time noise suppression (DeepCAD-RT) into our data preprocessing pipeline. At 500 Hz frame rates, we demonstrate a 75% increase in PNR using the denoised pHiLo reconstruction compared to pWF. Utilizing DeepCAD-RT, we show significant PNR improvements using both structured illumination (SI) reconstruction methods with OS-SIM showing a 59% increase in PNR after denoising. Both pHiLo and OS-SIM reconstructions result in a ≈65% decrease in the mean correlation coefficient of the ΔF/F time courses between ROIs in comparison with pWF, indicating the potential to remove background fluorescent transients from out-of-focus cells.
-
3. Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings.
PMID:日期:2024-10-31The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination. Remarkably, there was no measurable degradation over a 3-year study. Precise photoluminescence intensity modulation was accomplished with neutral density gel filters (R > 0.9982) and optical apertures (R > 0.9970). A model for photoluminescence intensity as a function of neutral-density filter and optical aperture parameters yielded a mean percentage error (MPE) of 2.79%, indicating high precision. Inter-sample variability was low, with a mean coefficient of variation (CV) of 1.32%. Mean CV across 24 channels decreased from 11.88% to 1.51% following multi-point calibration of multichannel point-of-care (POC) fluorometers. Cost analysis revealed a per-unit cost between $0.49 to $1.80. This work suggests that the proposed calibration standards provide a cost-effective, highly stable solution for reliable fluorometer calibration in low-resource settings.
-
4. Normalized weighted cross correlation for multi-channel image registration.
PMID:日期:2024-04-16The normalized cross-correlation ( ) is widely used for image registration due to its simple geometrical interpretation and being feature-agnostic. Here, after reviewing definitions for images with an arbitrary number of dimensions and channels, we propose a generalization in which each pixel value of each channel can be individually weighted using real non-negative numbers. This generalized normalized weighted cross-correlation ( ) and its zero-mean equivalent ( ) can be used, for example, to prioritize pixels based on signal-to-noise ratio. Like a previously defined with binary weights, the proposed generalizations enable the registration of uniformly, but not necessarily isotropically, sampled images with irregular boundaries and/or sparse sampling. All definitions discussed here are provided with discrete Fourier transform ( ) formulations for fast computation. Practical aspects of computational implementation are briefly discussed, and a convenient function to calculate the overlap of uniformly, but not necessarily isotropically, sampled images with irregular boundaries and/or sparse sampling is introduced, together with its formulation. Finally, examples illustrate the benefit of the proposed normalized cross-correlation functions.
-
5. Photothermal optical coherence tomography for 3D live cell detection and mapping.
PMID:日期:2023-11-27Imaging cells in their 3D environment with molecular specificity is important to cell biology study. Widely used microscopy techniques, such as confocal microscopy, have limited imaging depth when probing cells in optically scattering media. Optical coherence tomography (OCT) can provide millimeter-level depth for imaging of highly scattering media but lacks the contrast to distinguish cells from extracellular matrix or to distinguish between different types of cells. Photothermal OCT (PT-OCT) is a promising technique to obtain molecular contrast at the imaging scale of OCT. Here, we report PT-OCT imaging of live, nanoparticle-labeled cells in 3D. In particular, we demonstrate detection and mapping of single cell in 3D without causing call death, and show the feasibility of 3D cell mapping through optical scattering media. This work presents live cell detection and mapping at an imaging scale that complements the major microscopy techniques, which is potentially useful to study cells in their 3D native or culture environment.
-
6. Complex optically computed phase microscopy for label-free sub-cellular imaging.
PMID:日期:2023-03-27In this study, we investigated a complex optically computed phase microscopy (complex-OCPM) technology. Based on a low coherence interferometer and an innovative optical computation approach, the complex-OCPM imaging system achieves depth resolved quantitative phase measurement. Particularly, the complex-OCPM imaging system directly measures the complex amplitude of the optical field emerging from the sample, extracts the phase as the argument of a complex signal, and achieves a high spatial resolution in phase imaging. We evaluated the performance of complex-OCPM imaging using resolution targets and live cells. Our results show that the complex-OCPM system achieves quantitative phase imaging with sub-cellular resolution on label-free cells.
-
7. Computational microscopy for fast widefield deep-tissue fluorescence imaging using a commercial dual-cannula probe.
PMID:日期:2022-09-15A solid-glass cannula serves as a micro-endoscope that can deliver excitation light deep inside tissue while also collecting emitted fluorescence. Then, we utilize deep neural networks to reconstruct images from the collected intensity distributions. By using a commercially available dual-cannula probe, and training a separate deep neural network for each cannula, we effectively double the field of view compared to prior work. We demonstrated ex vivo imaging of fluorescent beads and brain slices and in vivo imaging from whole brains. We clearly resolved 4 μm beads, with FOV from each cannula of 0.2 mm (diameter), and produced images from a depth of ~1.2 mm in the whole brain, currently limited primarily by the labeling. Since no scanning is required, fast widefield fluorescence imaging limited primarily by the brightness of the fluorophores, collection efficiency of our system, and the frame rate of the camera becomes possible.
-
8. Automated bone cell classification for confocal laser scanning microscopy volumes.
PMID:日期:2022-06-07Manual cell classification in microscopy images is a time-consuming process that heavily relies on the subjective perception of the investigator. Identifying bone cells introduces additional difficulties with irregular geometries, and in some culture conditions, the presence of bone mineral. As fluorescence-based lineage tracing becomes more common, classifying cell types based upon cell color can further increase subjectivity. Our goal is to develop and validate a fully automated cell classification algorithm that can (i) objectively identify cells in flattened volumetric image stacks from three-dimensional (3D) bone cell cultures and (ii) classify the cells (osteoblast-lineage) based on the color of their cell bodies. The algorithm used here was developed in MATLAB 2019a and validated by comparing code outputs to manual labeling for eleven images. The precision, recall, and F1 scores were higher than 0.75 for all cell classifications, with the majority being greater than 0.80. No significant differences were found between the manually labelled and automated cell counts or cell classifications. Analysis time for a single image averaged seventeen seconds compared to more than ten minutes for manual labeling. This demonstrates that the program offers a fast, repeatable, and accurate way to classify bone cells by fluorescence in confocal microscopy image data sets. This process can be expanded to improve investigation of other pre-clinical models and histological sections of pathological tissues where color or fluorescence-based differences are used for cell identification.