Journal for the Measurement of Physical Behaviour身体行为测量杂志
Journal for the Measurement of Physical Behaviour(英文缩写 J MEAS PHYS BEHAV),ISSN 2575-6605,eISSN 2575-6613,中文译名:身体行为测量杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2024 | 1.700 | Q3 |
| 2025 | 1.500 | Q3 |
Journal for the Measurement of Physical Behaviour 最新收录文献
-
1. Real-Time Versus Video-Recorded Step Count Validation Among Young Adults.
PMID:日期:2026-03-16Consumer Technology Association guidelines recommend two independent researchers review video recordings of treadmill bouts to verify accuracy of the number of steps taken. Performing multiple post hoc validation checks requires significant resources for personnel time and costs, but it is unknown if the burden is necessary. The purpose of this study was to evaluate accuracy and efficiency of step counts assessed during direct observation compared with multiple reviews of video recordings. Participants ages 18-20 years (n = 72) completed up to twelve 5-min, zero-incline treadmill bouts, speeds ranging 0.2-2.7 m/s (0.5-6.0 mph). Directly observed steps were counted and hand-tallied in real-time. A sex-age stratified random sample of 30 participants' bouts were selected for analysis. Two independent researchers recounted steps from video recordings, producing three independent counts. Intraclass correlation coefficient determined interrater reliability. Mean average percent deviation computed deviation magnitude among the three counts. Correlation tests determined the relationship between absolute count differences and average counts for each pairwise comparison. Interrater reliability was excellent with intraclass correlation coefficients ≥ .995 (p < .001) across all speeds. Average mean average percent deviation was 0.29% with bout-specific deviations ranging from 0.10% to 0.54%, indicating < 1% difference among the three counts for all bouts. A single real-time step count represents a sufficient and efficient approach to measure steps taken in a controlled treadmill setting, while video recounts serve as back-up to allay potential data loss concerns and/or for random selection verification. These data-driven findings are useful for optimizing personnel time and reducing costs associated with collecting quality data in large-scale treadmill-based step-counting studies.
-
2. The Concurrent Validity of the ActiGraph LEAP Compared to the ActiGraph GT9X Link for Measuring Physical Activity.
PMID:日期:2026-02-05The ActiGraph GT9X Link wearable accelerometer has been widely utilized for physical activity (PA) measurement but is no longer in production. The performance of the ActiGraph LEAP, regarded as its successor and released in 2023, remains unevaluated in comparison to other accelerometers. This study aimed to establish concurrent validity of the ActiGraph LEAP device through PA measurements and comparison with the GT9X Link. A total of 26 young adults (mean age = 21 ± 4 years) wore the ActiGraph LEAP and GT9X Link simultaneously for 7 consecutive days on their nondominant wrist. Monitor Independent Movement Summary units were utilized for calculation of daily sedentary time, light PA, and moderate to vigorous PA across valid days of wear (≥10 hr). Nonwear time was determined using a preexisting algorithm. Intraclass correlation coefficient, mean absolute percent error, equivalence tests (with GT9X Link as reference), and Bland-Altman plots assessed agreement between daily values of sedentary time, light PA, and moderate to vigorous PA recorded by each device across all valid days recorded among participants. A total of 149 days of data were compared between the two devices. Across all PA levels, acceptable-excellent agreement was found (mean absolute percent error = 3.86%-13.86% and intraclass correlation coefficient = .94-.99), and Bland-Altman plots showed that at least 90% of recorded data fell within the 95% limits of agreement. The findings suggest that sedentary time and PA measurements using Monitor Independent Movement Summary units from the ActiGraph LEAP compare well with the GT9X Link, indicating that the LEAP performs similarly to the GT9X Link.
-
3. The Ability of Monitor-Independent Movement Summary Units, Euclidean Norm Minus One, and Mean Amplitude Deviation to Harmonize Accelerometry Data Across Research-Grade and Consumer Wearable Devices During Simulated Free-Living Physical Activity in Children.
PMID:日期:2025-08-19Epoch-level accelerometry summary metrics have the potential to be device-agnostic, meaning that similar estimates should be obtained regardless of the device used. The objective of this study was to identify which metric (ENMO, MAD, MIMS) best harmonizes data across devices in an applied setting measuring children's activity. Children (n=239; 9.3 ± 2.1 years, 47% female, 30% Black) wore ActiGraph GT9X (+/-8g, 50Hz) accelerometers and were randomized to wear two of three consumer wearables including Apple Watch Series 7 (+/-16g, 50Hz), Garmin Vivoactive 4S (+/-8g, 25Hz), and Fitbit Sense (+/-4g, 50Hz) on their non-dominant wrist, while participating in 60 minutes of simulated free-living activities (i.e., walking, running, soccer). The standard deviation (SD) across z-scores for ENMO, MAD and MIMS of each device was calculated at the second-level to quantify variability across devices. Lin's Concordance Correlation Coefficient (LCCC) was calculated for each combination of devices by metric to determine agreement. Multi-level intra-class correlation coefficients (ICC) were additionally used to quantify harmonization. The SD of z-score across devices was the lowest, indicating better harmonization, for MAD (0.13±0.23), followed by ENMO (0.24±0.50), and then MIMS (0.26±0.39). LCCC was strongest for MAD, with coefficients ranging from 0.89 to 0.96. LCCC for MIMS ranged from 0.70 to 0.83, and was lowest for ENMO, ranging from 0.62 to 0.76. Overall ICC was highest for MAD (0.88), followed by MIMS (0.73), and ENMO (0.62). MAD appears to perform best at harmonizing across all the sampled research-grade and consumer devices in children.
-
4. Performance evaluation of algorithms to estimate daily sedentary time using wrist-worn sensors in free-living adults.
PMID:日期:2025-06-10Given the limited real-world testing of algorithms for wrist-worn sensors to estimate sedentary time, we examined the performance of 21 algorithms in free-living adults. Seventy-one adults (35-65 years) wore a GENEActiv (wrist) and an activPAL (thigh) sensor for up to 10 days. activPAL was our reference measure. We estimated sedentary time (hours/day) using 21 classification algorithms, including cut point and machine-learning methods. Valid days from each monitor were matched by date and mean values were calculated. Equivalence testing (±10%) and linear regression were used to compare each algorithm's estimate to the reference, over all participants and by sex and age. activPAL recorded a mean of 9.4 hours/d sedentary. Five of 21 algorithms (24%) estimated sedentary time within 10% (±0.94 hours) of the reference. Two of these methods employed machine-learning algorithms (Trost Extended, OxWearables) and three employed cut points (GGIR ENMO 40mg; Bakrania ENMO 32.6mg; Fraysse ENMOa 62.5mg). Variance explained in linear regression was relatively high for the machine-learning (R=0.44-0.63) and cut point algorithms developed for younger (R=0.30-0.64) and older (R=0.45-0.66) adults. More accurate performance was noted for algorithms developed in studies using posture-based ground truth measures and conducted in free-living settings. Fifteen of 21 (71%) algorithms produced estimates of sedentary time that were moderate-strongly correlated with the reference measure, but only five (24%) were within 10% of the reference. Free-living benchmarking studies like this can identify more accurate and precise algorithms to estimate sedentary time and identify characteristics of algorithm development studies that yield better results.
-
5. Comparing Multiple Approaches to Estimate Physical Activity, Sedentary Behavior, and Sleep in Pregnancy.
PMID:日期:2024-11-19The purpose of this study was to compare estimates of 24-hour activity using the best practice of a thigh accelerometer (activPAL), wrist actigraphy (Actiwatch), and a sleep diary () to estimates from simpler procedures, such as the thigh accelerometer and diary () or thigh monitor alone () during pregnancy. Data collected during the 2 trimester from 40 randomly selected participants in the Pregnancy 24/7 cohort study were included. activPAL data were integrated with sleep time determined by wrist actigraphy () or diary-determined sleep (). In the analysis, average estimates were exported directly from the PAL software. Repeated measures ANOVA and intraclass correlations coefficients compared moderate-vigorous physical activity (MVPA), light physical activity (LPA), sedentary time, sleep, and wear time across measurement approaches. Pairwise comparisons using a Bonferroni correction explored significant differences identified from the omnibus ANOVA. The three approaches arrived at consistent durations of physical activity (intraclass correlations coefficients > .95) but not for estimating sedentary behavior and sleep durations (intraclass correlations coefficients: .73-.82). PAL + diary overestimated MVPA by 2.3 min/day (p < .01) compared with PAL + diary + watch. PAL only overestimated sleep (25.3-29.0 min/day, p < .01) while underestimating MVPA (11.7-14.0 min/day, p < .01) compared with the other approaches. Since the inclusion of the wrist actigraphy provided only slight differences in MVPA estimates, may provide acceptable estimates of 24-hour activity during pregnancy in future research. may be acceptable when exclusively interested in physical activity.
-
6. Identifying Multicomponent Patterns and Correlates of Accelerometry-Assessed Physical Behaviors Among Postmenopausal Women: The Women's Health Accelerometry Collaboration.
PMID:日期:2024-09-10Understanding the simultaneous patterning of accelerometer-measured physical activity and sedentary behavior (physical behaviors) can inform targeted interventions. This cross-sectional study described multi-component patterns and correlates of physical behaviors using accelerometry among diverse postmenopausal women. The Women's Health Accelerometry Collaboration combined two United States-based cohorts of postmenopausal women with similar accelerometry protocols and measures. Women (n=22,612) 62 to 97 years enrolled in the Women's Health Study (n=16,742) and the Women's Health Initiative Objective Physical Activity and Cardiovascular Health Study (n=5870) wore an ActiGraph GT3X+ accelerometer on their hip for one week. Awake-time accelerometry data were summarized using the accelerometer activity index into sedentary behavior, light (low, high), and moderate-to-vigorous physical activity. Latent class analysis was used to classify physical behavior hour-by-hour. Five unique patterns were identified with higher total volume of physical activity and lower sedentary behavior with each successively higher-class number based on percentage of the day in physical activity/sedentary behavior per hour over seven days. The percentage assignment was 16.3% class 1, 33.9% class 2, 20.2% class 3, 18.0% class 4, and 11.7% class 5. Median posterior probabilities ranged from 0.99-1.00. Younger age, higher education and general health, normal weight, never smokers, weekly drinking, and faster self-reported walking speed generally had higher class assignment compared to their counterparts. History of diabetes and cardiovascular disease generally had lower class assignment compared to those without these conditions. These results can inform targeted interventions based on common patterns of physical behaviors by time of day among postmenopausal women.
-
7. {"_":": An R Package to Calculate ActiGraph Activity Counts From Portable Accelerometers.","i":["agcounts"]}
PMID:日期:2024-04-26Portable accelerometers are used to capture physical activity in free-living individuals with the ActiGraph being one of the most widely used device brands in physical activity and health research. Recently, in February 2022, ActiGraph published their activity count algorithm and released a Python package for generating activity counts from raw acceleration data for five generations of ActiGraph devices. The nonproprietary derivation of the ActiGraph count improved the transparency and interpretation of accelerometer device-measured physical activity, but the Python release of the count algorithm does not integrate with packages developed by the physical activity research community using the R Statistical Programming Language. In this technical note, we describe our efforts to create an R-based translation of ActiGraph's Python package with additional extensions to make data processing easier and faster for end users. We call the resulting R package and provide an inside look at its key functionalities and extensions while discussing its prospective impacts on collaborative open-source software development in physical behavior research. We recommend that device manufacturers follow ActiGraph's lead by providing open-source access to their data processing algorithms and encourage physical activity researchers to contribute to the further development and refinement of and other open-source software.
-
8. Measurement Reactivity in Ecological Momentary Assessment Studies of Movement-Related Behaviors.
PMID:日期:2024-04-15Measurement reactivity has implications for behavioral science, as it is crucial to determine whether changes in constructs of interest represent true change or are an artifact of assessment. This study investigated whether measurement reactivity occurs for movement-related behaviors, motivational antecedents of behavior, and associations between them. Data from ecological momentary assessment studies of older adults ( = 195) and women in midlife ( = 75) lasting 8-10 days with 5-6 prompts/day and ambulatory monitoring of movement were used for this secondary data analysis. To examine potential drop-off patterns indicative of measurement reactivity, multilevel models tested whether behavior, antecedents, and associations changed after the first or first 2 prompts compared with remaining prompts and the first, first 2, or first 3 days compared with remaining days. Older adults' sedentary behavior was lower, and time spent upright and intentions and self-efficacy to stand/move were higher on the first 2 and first 3 days compared with remaining days. Associations between intentions and self-efficacy and subsequent sedentary behavior were weaker earlier in the study compared to later. For women in midlife, light physical activity was higher at the first and first 2 prompts compared with remaining prompts, and physical activity motivation was higher across all prompts and days tested. There was a stronger association between intended and observed minutes of moderate to vigorous physical activity on the first 2 days compared with remaining days. Measurement reactivity appeared as expected for movement-related behaviors and motivational antecedents, though changes in between these constructs are likely do not reflect measurement reactivity.
-
10. Convergent validity of time in bed estimates from activPAL and Actiwatch in free-living youth and adults.
PMID:日期:2023-08-30Actiwatch devices are often used to estimate time in bed (TIB), but recently became commercially unavailable. Thigh-worn activPAL devices could be a viable alternative. We tested convergent validity between activPAL (CREA algorithm) and Actiwatch devices. Data were from free-living samples comprising 47 youth (3-16 valid nights/participant) and 42 adults (6-26 valid nights/participant) who wore both devices concurrently. On average, activPAL predicted earlier bedtimes and later risetimes compared to Actiwatch, resulting in longer overnight intervals (by 1.49 hours/night for youth and 0.67 hours/night for adults; both p < 0.001). TIB interruptions were predicted less commonly by activPAL (mean < 2 interruptions/night for both youth and adults) than Actiwatch (mean of 24-26 interruptions/night in both groups; both p < 0.001). Overnight intervals for both devices tended to overlap for lengthy periods (mean of 7.38 hours/night for youth and 7.69 hours/night for adults). Within these overlapping periods, the devices gave matching epoch-level TIB predictions an average of 87.9% of the time for youth and 84.3% of the time for adults. Most remaining epochs (11.8% and 15.1%, respectively) were classified as TIB by activPAL but not Actiwatch. Overall, the devices had fair agreement during the overlapping periods, but limited agreement when predicting interruptions, bedtime, or risetime. Future work should assess the criterion validity of activPAL devices to understand implications for health research. The present findings demonstrate that activPAL is not interchangeable with Actiwatch, which is consistent with their differing foundations (thigh inclination for activPAL versus wrist movement for Actiwatch).