EFORT Open ReviewsEFORT开放综述
EFORT Open Reviews(英文缩写 EFORT OPEN REV),ISSN 2396-7544,eISSN 2058-5241,中文译名:EFORT开放综述 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.775 | Q1 |
| 2022 | 3.400 | Q1 |
| 2023 | 4.300 | Q1 |
| 2024 | 4.000 | Q1 |
| 2025 | 4.600 | Q1 |
EFORT Open Reviews 最新收录文献
-
1. External fixation in severe open tibial shaft fractures: indications, orthoplastic strategy, and infection-aware decision-making.
PMID:日期:2026-10-01Intramedullary nailing remains the preferred definitive fixation for most open tibial shaft fractures once contamination is controlled and soft tissues permit internal implantation. External fixation should be chosen according to intent: damage control, preservation of orthoplastic access, staged bridge to internal fixation, or definitive frame-based reconstruction. Temporary frames are most useful in polytrauma, vascular injury, severe swelling, gross contamination, and wounds needing serial debridement, flap planning, or negative-pressure therapy. Conversion to intramedullary nailing is appropriate only when margins are declared, coverage is complete or reliably scheduled, contamination is controlled, and fracture-related infection (FRI) is not suspected. Definitive circular or hybrid fixation is favored when repeated excision, vascular repair, segmental bone loss, bone transport, uncertain margins, or suspected/established FRI makes buried metal less attractive. Successful frame treatment requires safe pin placement outside flap and implant corridors, restoration of length, axis, and rotation without distraction, timely soft-tissue coverage, and standardized infection and pin-site pathways.
-
2. Arthroscopic versus open repair for triangular fibrocartilage complex foveal tears: a systematic review and meta-analysis.
2. 关节镜与开放式修复治疗三角纤维软骨复合体凹部撕裂:系统评价与荟萃分析PMID:日期:2026-10-01PURPOSE METHODS RESULTS CONCLUSION
-
3. A review of digital orthopedic techniques in pre- and intra-operative management of scaphoid fracture.
PMID:日期:2026-10-01Digital orthopedics integrates artificial intelligence, finite element analysis, virtual surgical planning, intraoperative navigation, robotics, and three-dimensional printing into a precise, individualized workflow for scaphoid fracture management. Artificial intelligence-based algorithms achieve high diagnostic accuracy for scaphoid fractures on plain radiographs, aid in detecting occult fractures, and support treatment decisions. Three-dimensional fracture mapping and finite element analysis enable quantitative assessment of fracture morphology and biomechanical stability, supporting individualized preoperative planning. Computer-assisted navigation reduces radiation exposure and guidewire attempts compared with conventional fluoroscopy but remains limited by registration inaccuracy and dependence on manual execution. Robot-assisted surgery improves procedural consistency and screw accuracy, with a learning curve of approximately 10-20 cases; however, it is constrained by longer setup times, high costs, and predominantly level IV evidence. Virtual surgical planning combined with three-dimensional printing provides patient-specific percutaneous guides, reduction templates, anatomical models, and custom prostheses, improving accuracy, reducing radiation exposure, and enabling motion-preserving salvage for scaphoid nonunions and scaphoid nonunion advanced collapse. Current evidence is largely based on small case series and cadaveric studies, highlighting the need for standardized protocols and high-quality comparative trials to support widespread adoption.
-
4. Periprosthetic fractures of the knee.
4. 膝关节假体周围骨折PMID:日期:2026-10-01Periprosthetic fractures around total knee arthroplasty are an increasingly common and complex problem driven by rising arthroplasty volumes, aging populations, and longer implant survivorship. Successful management requires integration of trauma principles with arthroplasty-specific considerations, particularly implant stability, bone stock, and patient frailty. Implant stability and bone quality are the primary determinants of treatment strategy, outweighing fracture morphology alone. Classification systems are useful frameworks but must be interpreted in the context of component fixation and host factors. Fixation using locked plating, retrograde intramedullary nailing, or combined constructs is appropriate for stable implants with adequate bone stock and achieves high union rates, while preserving bone and future revision options, particularly important in younger or active patients. Revision arthroplasty with stemmed components, cones or sleeves, and appropriate constraint is indicated for loose components or compromised bone stock, offering durable reconstruction but with complication profiles similar to complex revision total knee arthroplasty. Distal femoral replacement serves as an effective salvage option for fractures that cannot be fixed or in frail, low-demand patients, enabling immediate weight-bearing but at the cost of higher complication and re-revision rates. Overall, outcomes depend not only on fracture union but also on restoration of alignment, extensor mechanism function, and early mobilization. High complication rates reflect the combined burden of fragility fracture biology and revision arthroplasty complexity, underscoring the need for individualized, patient-centered decision-making.
-
5. Local hyperthermia therapy for the pain management of knee osteoarthritis: a network meta-analysis of randomized controlled trials.
5. 局部热疗治疗膝骨关节炎疼痛管理:随机对照试验的网络荟萃分析PMID:日期:2026-10-01PURPOSE METHODS RESULTS CONCLUSIONS
-
6. Unilateral biportal endoscopy versus percutaneous transforaminal endoscopic discectomy for far lateral lumbar disc herniation: a systematic review and meta-analysis.
PMID:日期:2026-10-01OBJECTIVE METHODS RESULTS CONCLUSION
-
7. Acetabular revision surgery revisited: do changing indications influence bone defect management? A comprehensive review.
7. 髋臼翻修手术再探讨:适应证的改变是否影响骨缺损的处理?一项综合综述PMID:日期:2026-10-01Modern bearings have changed reasons for revision hip surgery; however, acetabular bone defects are still a challenging condition. Advanced imaging techniques, including newer 3D preoperative planning, have improved the understanding of bone stock. Current acetabular tools reduce the bone loss during implant removal and are reliable to predict the new reconstruction. Although bone allograft is useful in younger patients with a high lifetime risk for revision, some limitations have been reported for segmental large defects and pelvic discontinuity. Encouraging results are obtained with porous metal augments and custom-made implants in combination or not with bone grafts, but long-term results and cost-effectiveness are controversial. In this review, we aimed to address the best rationale to this complex topic 25 years after the introduction of highly cross-linked polyethylene. Furthermore, we sought to identify whether the lower prevalence of osteolysis eases acetabular revision surgery within the increasing number of re-revision surgeries.
-
8. Complication and work-related recovery between ulnar shortening osteotomy and arthroscopic wafer procedure: a combination of frequentist and Bayesian meta-analysis.
8. 尺骨短缩截骨术与关节镜下Wafer手术的并发症及工作相关恢复情况:频率学派与贝叶斯Meta分析的联合应用PMID:日期:2026-10-01PURPOSE METHODS RESULTS CONCLUSION
-
9. Orthopedic implant allergies: a review of current knowledge on metal hypersensitivity and prosthesis failure.
9. 骨科植入物过敏:金属超敏反应与假体失效的现有知识综述PMID:日期:2026-10-01Metal hypersensitivity is an increasingly recognized factor in orthopedic implant failure, particularly in patients undergoing total joint arthroplasty (TJA), and may contribute to persistent pain, aseptic loosening, or early revision. This review synthesizes current evidence on the underlying immune mechanisms of metal hypersensitivity and explores their potential role in implant-related complications such as chronic inflammation, pain, and aseptic loosening. A systematic literature search was conducted using Embase.com and complementary databases; relevant studies involving patients with suspected or confirmed allergic responses to metallic orthopedic implants were identified and integrated into a narrative review of clinical presentations, diagnostic strategies, and outcomes. Diagnostic approaches remain variable and include clinical evaluation, dermatological patch testing, in vitro assays such as the lymphocyte transformation test (LTT), and histopathological examination of periprosthetic tissues, with no current consensus on a gold-standard method. Although metal hypersensitivity is associated with a subset of implant failures, the strength of evidence is limited by heterogeneous study designs, variable diagnostic criteria, and inconsistent reporting of outcomes. Future efforts should focus on standardizing diagnostic protocols, validating predictive tests, and developing patient-specific management algorithms - particularly regarding implant material selection - to improve care for patients with suspected metal allergies in orthopedic surgery.
-
10. Unicompartmental and total knee arthroplasty in the same patient for the treatment of bilateral knee osteoarthritis: a systematic review of literature.
10. 同一患者行单间室与全膝关节置换术治疗双侧膝骨关节炎:文献系统综述PMID:日期:2026-10-01PURPOSE METHODS RESULTS CONCLUSION