ANNALES DE BIOLOGIE CLINIQUE临床生物学年鉴
ANNALES DE BIOLOGIE CLINIQUE(英文缩写 ANN BIOL CLIN-PARIS),ISSN 0003-3898,eISSN 1950-6112,中文译名:临床生物学年鉴 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 0.516 | Q4 |
| 2022 | 0.500 | Q4 |
| 2023 | 0.400 | Q4 |
| 2024 | 0.400 | Q4 |
| 2025 | 0.400 | Q4 |
ANNALES DE BIOLOGIE CLINIQUE 最新收录文献
-
1. [Analytical limitations of potassium measurement in cases of severe leukocytosis: a case report].
1. [严重白细胞增多时钾测定的分析局限性:一例病例报告]PMID:日期:2026-09-10该文献暂无摘要。
-
2. [SFBC/CNBH Working Group on the evaluation of blood glucose measurement in the laboratory: results of a survey conducted in France and French-speaking laboratories].
2. [SFBC/CNBH实验室血糖测量评估工作组:法国及法语实验室调查结果]PMID:日期:2026-09-10Blood glucose is one of the most frequently measured laboratory parameters. This study, conducted by the SFBC and CNBH, aimed to assess current practices and identify areas for improvement. An 82-question online questionnaire covering the pre-analytical, analytical, and post-analytical phases of blood glucose measurement was distributed at the end of 2025 to members of the SFBC (French Society of Clinical Biology) and the CNBH (National College of Hospital Biochemistry). Seventy-two laboratories completed the questionnaire: 57 in metropolitan France, 4 in the French overseas departments and territories (DROM-COM), and 11 in other French-speaking countries. Respondents were mostly hospitals (n = 35) and university hospitals (n = 29). Blood glucose testing is available 24/7 in 95.8% of laboratories. The pre-analytical phase is heterogeneous, particularly regarding the recommended fasting duration for fasting blood glucose measurement and the time elapsed after a meal for postprandial blood glucose measurement. Tubes containing sodium fluoride with potassium oxalate are predominantly used, and no laboratory uses citrate-sodium fluoride-EDTA tubes. The time before centrifugation is less than 30 minutes for fewer than 10 % of laboratories. Regarding the analytical phase, the hexokinase method predominates (86.7%), and very satisfactory analytical performance is observed. For the post-analytical phase, a lack of standardization is noted, particularly concerning reference values range and units of measurement. This survey highlights substantial variability in glucose testing practices, particularly in the pre-analytical phase. Harmonization of procedures is needed to improve result reliability, comparability, and patient safety.
-
3. [SFBC/CNBH Working Group on the evaluation of blood glucose measurement in laboratory: evolution of blood glucose measurement and diagnostic criteria for diabetes].
3. [SFBC/CNBH实验室血糖测量评估工作组:血糖测量的演变与糖尿病诊断标准]PMID:日期:2026-09-10The evolution of blood glucose assays reflects the constant progress in laboratory medicine toward increasing analytical precision, serving both diagnosis and patient management. While pioneering, early chemical methods had significant limitations in terms of specificity and reproducibility. Their gradual replacement by enzymatic techniques, particularly those based on glucose oxidase and later on hexokinase, represented a major advance, improving the reliability, sensitivity, and standardization of assays. These developments led to the establishment of internationally recognized reference values and diagnostic thresholds. However, the question of their comparability with the analytical methods currently used in laboratories remains. In this context, this review aims to trace the historical evolution of blood glucose assays and their associated reference values. This involves addressing, on the one hand, reference values according to sampling conditions (fasting, postprandial, oral glucose tolerance test), and on the other hand, diagnostic thresholds for diabetes mellitus. These values are based on recommendations from international scientific organizations, such as the World Health Organization and the American Diabetes Association.
-
4. [The role of clinical laboratory testing in athlete monitoring: health, performance, and prevention of overtraining].
PMID:日期:2026-09-10Physical activity provides numerous health benefits but may also be associated with biological alterations related to training intensity, nutritional deficiencies, overtraining, or doping practices. This article reviews the main biological parameters used in athlete monitoring and their relevance for assessing health status, adaptation to exercise, and performance. These parameters encompass hematological, biochemical, and endocrine markers. The complete blood count enables the evaluation of blood cell adaptations to exercise and the detection of anemia or abnormalities in erythropoiesis. Biochemical investigations provide information on iron and vitamin status, inflammation, muscle integrity, renal function, fluid and electrolyte balance, and energy metabolism. Assessment of hormonal axes, particularly the corticotropic, gonadotropic, and somatotropic axes, contributes to the evaluation of training adaptation and the identification of conditions such as low energy availability and overtraining. Some biomarkers may also assist in the detection of doping practices. Interpretation of laboratory results requires consideration of the physiological adaptations induced by exercise, the sport discipline, training load, and the time elapsed since the last exercise session. Blood sampling should ideally be performed at least 48 hours after intense exercise. In the absence of universal recommendations, biological monitoring should be individualized. The medical laboratory specialist plays a central role in selecting appropriate tests and interpreting results to help preserve athletes' health.
-
5. [2026 update to the LABAC-SFBC recommendations for the implementation and monitoring of internal quality controls in medical laboratories].
5. [2026年LABAC-SFBC医学实验室内部质量控制实施与监测建议更新]PMID:日期:2026-09-10The recommendations presented in this document are the result of joint work conducted by LABAC and the SFBC. They update the recommendations issued in 2019. The different steps involved in implementing quality controls, based on risk analysis, are described. Reagent lot changes and internal quality control (IQC) lot changes, the actions to be taken in the event of non-conforming IQC, and the maintenance of multi-analyzer comparability are addressed. These recommendations do not claim to cover every possible situation that may arise within a laboratory. The implementation of an alternative strategy, provided that it is justified and objective, should also be considered.
-
6. Diagnosis of ovarian cancer using multiple biomarkers of CA 125, CA153, CA 19-9, CEA, HE4 and ROMA index.
6. 使用CA 125、CA153、CA 19-9、CEA、HE4多种生物标志物及ROMA指数诊断卵巢癌PMID:日期:2026-09-10To investigate the value of tumor biomarkers of CA125, CA153, CA 19-9, CEA, human epididymis protein 4 (HE4) and ROMA index in combination for the diagnosis of epithelial ovarian tumors. Patients with epithelial ovarian tumors were retrospectively enrolled in comparison with healthy controls. The venous blood samples were tested and analyzed. The CA 19-9 value was significantly (P < 0.05) greater in borderline tumors than in ovarian cancers, benign tumors or healthy controls, and significantly (P < 0.05) greater in benign tumors than in healthy controls. Compared with the borderline tumors, the ovarian cancer in stages III and IV had significantly (P < 0.05) greater CA 125, CA 153, HE 4, ROMA 1 and ROMA 2 but significantly (P < 0.05) smaller CA 19-9. Stage-II ovarian cancer also had significantly (p < 0.05) greater CA 153 but smaller CA 19-9 than borderline tumors. The CA 19-9 value was significantly greater in the epithelial mucous cancer (50.15) or the borderline non-mucinous (22.90) or mucinous (47.55) tumor than in the non-mucinous cancer (12.15), benign tumors (14.80), or healthy controls (9.40). CA 125, CA 19-9, HE 4, ROMA 1, ROMA 2 and CA 153 had larger AUC and Youden indexes for diagnosing borderline tumors, and CA 125, CA 153, HE 4, ROMA 1 and ROMA 2 had larger AUC and Youden indexes for diagnosing ovarian cancers. For epithelial borderline tumors, CA 125, HE 4, ROMA 1, and ROMA 2 may have higher diagnostic value, especially ROMA 2 and CA 125. For ovarian cancer, ROMA 2, CA125, ROMA 1, HE4, and CA153 may have the highest clinical application value. CA 19-9 elevation may indicate mucinous ovarian cancer or mucinous borderline tumor. Elevated CA153 also has certain application value.
-
7. [Hemolysis, icterus, and lipemia indices and the post-analytical phase: monitoring laboratory practices].
PMID:日期:2026-09-10该文献暂无摘要。
-
8. [Evaluation of analytical transferability between two methods for measuring serum iron levels using Ferrozine and Ferene S].
PMID:日期:2026-08-27Serum iron is a routinely ordered test for assessing iron metabolism. Among colorimetric assays, Ferrozine- and Ferene S-based methods are widely used; however, analytical differences may compromise result comparability across platforms. This study evaluated the analytical transferability of serum iron results between these two methods performed on different analyzers. In accordance with the CLSI EP09-A3 guideline, 40 serum samples were analyzed in duplicate using two colorimetric methods: Ferrozine on the Roche Cobas Integra 400+ and Ferene S on the DiaSys Respons 920. Method agreement was assessed using Passing-Bablok regression, Bland-Altman analysis, and clinical concordance analysis. Mean serum iron concentrations were slightly higher with the Ferene S method than with the Ferrozine method, with a statistically significant paired difference (p = 0.001) and very high clinical concordance (κ = 0.91). The two methods were strongly correlated (r = 0.992; p < 0.001) and showed a constant bias of -0.845 (95% CI: -1.672 to -0.043). Bland-Altman analysis demonstrated a mean bias of -0.99 μmol/L with narrow limits of agreement (-2.08 to +0.09 μmol/L). The relative bias (-6.15 %) remained well below the predefined analytical tolerance threshold. Ferrozine and Ferene S based assays showed satisfactory analytical transferability and can be used comparably for serum iron measurement under the evaluated conditions.
-
9. [Immunoglobulin D lambda multiple myeloma: diagnosis guided by light chain deposition nephropathy].
PMID:日期:2026-08-27Immunoglobulin D (IgD) multiple myeloma is a rare entity, accounting for 1 to 2% of myelomas, characterized by aggressive progression and frequent renal involvement. Its diagnosis is often delayed due to the low serum concentration of IgD and the absence of a monoclonal peak on serum protein electrophoresis. We report the case of a 56-year-old patient with no significant medical history who was hospitalized for severe renal failure associated with profound anemia. Renal biopsy revealed myelomatous nephropathy with tubular deposits of lambda light chains on immunofluorescence. Serum protein electrophoresis revealed hypogammaglobulinemia with an increase in the beta-2-globulin fraction. Serum immunofixation identified a monoclonal IgD lambda immunoglobulin associated with monoclonal free light chains (FLC) of lambda isotype. Serum FLC measurement confirmed a massive excess of lambda chains. The diagnosis was made in accordance with the 2014 International Myeloma Working Group (IMWG) criteria. This observation illustrates the diagnostic pitfalls of this entity and highlights the major importance of extended immunofixation, serum FLC measurement, and renal biopsy for early identification.