ACADEMIC RADIOLOGY学术放射学
ACADEMIC RADIOLOGY(英文缩写 ACAD RADIOL),ISSN 1076-6332,eISSN 1878-4046,中文译名:学术放射学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 5.482 | Q1 |
| 2022 | 4.800 | Q1 |
| 2023 | 3.800 | Q1 |
| 2024 | 3.900 | Q1 |
| 2025 | 4.700 | Q1 |
ACADEMIC RADIOLOGY 最新收录文献
-
1. Assessment of Pulmonary Vascular Stent Morphology Using Intra-procedural Cone-Beam CT in Fibrosing Mediastinitis: Imaging Agreement and Clinical Implications.
1. 使用术中锥形束CT评估纤维性纵隔炎中肺血管支架形态:影像一致性及临床意义PMID:日期:2026-10-03Percutaneous Pulmonary Vascular Stent Angioplasty (PPVSA) is a key treatment for pulmonary vascular stenosis in Fibrosing Mediastinitis (FM). This study evaluated the added value of intraoperative cone-beam computed tomography (CBCT) beyond conventional angiography for post-stenting assessment during PPVSA. This retrospective single-center study included 54 consecutive FM patients who underwent PPVSA between August 2021 and May 2024, comprising 114 stents (99 arterial and 15 venous). All patients underwent intraoperative CBCT, angiography, and follow-up computed tomography pulmonary angiography (CTPA) for assessment of stent geometry. Agreement between imaging modalities was evaluated using correlation, Bland-Altman, and reproducibility analyses. Associations between CBCT-derived parameters, hemodynamic outcomes, and stent patency were further explored. Among 54 patients (57.26 ± 11.47 years; 17 females [31.48%]), CBCT demonstrated excellent correlation with first follow-up CTPA. For maximum stent diameter, the correlation between CBCT and CTPA was r = 0.99, compared with r = 0.94 for angiography. For minimum stent diameter, the corresponding correlations were r = 0.99 and r = 0.85, respectively (all p < 0.001). Bland-Altman analysis showed smaller measurement bias and narrower limits of agreement for CBCT than for angiography. During a median imaging follow-up of 614.50 days, in-stent restenosis occurred in 15.79% of stents, whereas complete stent occlusion occurred in 1.75% of stents. Stents with a minimum-to-maximum diameter ratio <80% showed higher restenosis rates than those with a ratio ≥80% (24.00% vs. 9.38%, p = 0.017). In addition, among pulmonary arterial stents, a CBCT-derived stent relief index was positively correlated with trans-lesional systolic pressure gradient reduction (r = 0.249, p = 0.033). Intraoperative CBCT provides reliable assessment of stent geometry during PPVSA. In addition to demonstrating strong agreement with first follow-up CTPA, CBCT-derived morphologic parameters may be associated with procedural hemodynamic improvement and may provide supplemental information regarding subsequent stent patency and long-term outcomes.
-
2. Ultrasound-Based Habitat Radiomics for Differentiating Phyllodes Tumor from Breast Fibroadenoma.
2. 基于超声的生境放射组学用于区分乳腺叶状肿瘤与乳腺纤维腺瘤PMID:日期:2026-10-03Phyllodes tumors (PTs) and fibroadenomas (FAs) have overlapping ultrasound (US) appearances. This study aimed to develop and evaluate an interpretable machine-learning model integrating US radiomics, habitat features, and clinical variables. This retrospective multicenter study included 1950 pathologically confirmed lesions (1029 FAs and 921 PTs) divided into training (n=918), validation (n=474), and test (n=558) cohorts. Nineteen voxelwise features were used for K-means habitat segmentation. The number of clusters was selected from K=2-10 in the training cohort and evaluated across 50 random seeds. Whole-lesion, habitat, and combined habitat-radiomics (HR) signatures were developed using a train-only feature-selection pipeline, and ExtraTrees was selected as the classifier. The final combined model was built by probability-level late fusion of the ExtraTrees HR model and a logistic clinical model based on age, lesion size, and orientation. K=3 yielded the highest Calinski-Harabasz index (200,927.01). Clustering was stable across 50 random seeds, with mean adjusted Rand indices of 0.9942, 0.9948, and 0.9941 in the training, validation, and test cohorts, respectively. Feature selection retained 39 whole-lesion features and 34 habitat features (habitats 1-3: 1, 14, and 19). The combined model achieved AUCs of 0.921 (95% CI, 0.904-0.939), 0.797 (95% CI, 0.754-0.835), and 0.844 (95% CI, 0.813-0.877) in the training out-of-fold, validation, and test cohorts. In this multicenter cohort, a model integrating US habitat radiomics with age, lesion size, and orientation differentiated PTs from FAs with consistent discrimination across data partitions. Shapley additive explanations analysis provided global and case-level explanations of the combined prediction.
-
3. A National County-Level Typology of Imaging Infrastructure and the Radiologist Workforce in the United States.
3. 美国县级影像基础设施与放射科医生劳动力的全国类型学研究PMID:日期:2026-10-03This study aimed to perform a national county-level analysis integrating the local presence of both imaging equipment and radiologists into a unified typology of imaging access and to evaluate its association with imaging utilization. Radiologists were identified in the June 2026 National Plan and Provider Enumeration System using six verified taxonomy codes and assigned to counties by practice ZIP code. Imaging infrastructure combined hospital presence, Medicare computed tomography or magnetic resonance imaging billing, and certified mammography facilities. Counties were classified into four groups based on local radiologist and imaging equipment presence: true imaging deserts (neither), equipment-only, radiologist-only, and fully served (both). Sensitivity definitions used diagnostic-only taxonomies, Medicare billing, and billing-volume thresholds. Medicare imaging utilization was compared across categories. Multivariable logistic regression modeled radiologist absence and true imaging desert status. A total of 1692/3144 (53.8%) counties had no documented local radiologist. A total of 568 counties were true imaging deserts (1.9% of residents), 1124 were equipment-only (7.6%), 19 were radiologist-only (0.1%), and 1433 were fully served (90.4%). Imaging utilization was lower in true imaging deserts than fully served counties (3989 vs. 4242 per 1000, P < 0.001); this difference held across varying equipment definitions. The no-radiologist share ranged 53.8%-63.3% across three workforce definitions. At the commuting-zone level, the prevalence of no-radiologist counties decreased to 16.8% and of true imaging desert counties to 1.7%. Smaller population and lower education predicted both county-level outcomes. Local imaging access stratifies into four county types with measurable utilization differences. Equipment-only counties and true imaging deserts may warrant different policy responses.
-
4. Validation of Automated 3D MRI Knee Cartilage Measurements.
4. 自动三维MRI膝关节软骨测量的验证PMID:日期:2026-10-01To assess the agreement between automated cartilage thickness measurements derived from three-dimensional (3D) dual-echo steady-state (DESS) magnetic resonance imaging and manual radiologist measurements. In 111 patients, cartilage thickness measurements across 21 knee subregions were compared between an automated segmentation software and manual radiologist measurements on 3D DESS and proton density (PD) fat-suppressed sequences. Agreement was assessed using Bland-Altman analysis, Pearson correlation, and intraclass correlation coefficient (ICC). A post-hoc calibration approach was applied to both comparisons. Intersequence variability between PD manual and DESS manual measurements served as a benchmark. The automated method showed a systematic overestimation relative to the PD manual (bias +0.7 mm) and the DESS manual (bias +0.9 mm). After calibration, bias was eliminated. Postcalibration ICC improved substantially (PD: from 0.29-0.61; DESS: from 0.18-0.67), reaching levels comparable to the intersequence benchmark (ICC = 0.73). Per-region analysis revealed the greatest variability in patellar and lateral tibial subregions. Following a simple global calibration, automated cartilage thickness measurements achieve overall acceptable agreement with manual reference measurements that is comparable to inherent intersequence variability. This supports the clinical acceptability of the automated approach as an efficient and reproducible alternative to manual segmentation.
-
5. Implementation of an Early Exposure Program for College Students as a Strategy to Increase the Medical Imaging Workforce.
5. 实施大学生早期接触项目作为增加医学影像人才队伍的策略PMID:日期:2026-10-01Radiology careers require lengthy academic preparation, yet many students remain unaware of them until well into their studies, limiting early trajectory-setting and sustained motivation. We describe the architecture and implementation of the Radiology and Imaging Science Scholars program (RaISS), a pipeline program developed by the Department of Radiology at UC Davis Health to expose community college and early undergraduate students to radiology careers. RaISS treats community college and early undergraduate students as junior radiology colleagues, granting departmental badges and internal system access over a structured, six-month experience combining clinical shadowing, research engagement, mentorship, and professional development. Participants were recruited regionally and selected for interest in healthcare or biomedical sciences and limited prior exposure to academic medicine. Impact was assessed through post-program surveys of radiology understanding, career-pathway awareness, and confidence in further education. Across the first two cohorts (2024-2025), applications rose from 6 to 9 (31 received for 2026). Survey response rate was 58% (7 of 12); all respondents strongly agreed that the program increased their awareness of radiology/imaging careers, and 100% reported it influenced career consideration. One 2024 participant has since matriculated to medical school. Mentor survey completion was 67% (8 of 12); all 2024 mentors expressed interest in returning. Onboarding took about 4 weeks and was a key barrier. Structured early exposure to radiology through mentorship, clinical observation, and research engagement may broaden awareness of imaging careers among students with limited access to academic medicine, supporting efforts to strengthen the radiology workforce pipeline.
-
6. Echogenic Rind as an Independent Diagnostic and Prognostic Marker of Malignancy.
6. 高回声边缘作为恶性肿瘤的独立诊断和预后标志物PMID:日期:2026-10-01Echogenic rind has been incorporated into the BI-RADS v2025 ultrasound lexicon as an associated feature of masses; however, its utility as an independent diagnostic and prognostic marker of malignancy has not been well established. This retrospective study compares the imaging and phenotypic features of biopsy-proven malignant masses with and without an echogenic rind to assess its utility as an imaging marker. Consecutive patients with biopsy-proven malignant masses were placed into separate cohorts based on the presence/absence of an echogenic rind. An echogenic rind was defined as an ≥1 mm echogenic band that surrounded at least 25% of the mass circumference and disrupted adjacent tissue. Imaging characteristics (size, shape, margins, orientation), tumor type (ductal carcinoma in situ [DCIS], invasive ductal carcinoma, and invasive lobular carcinoma), receptor status, and Nottingham grades of masses in both cohorts were compared using Fisher's exact test and multivariate analysis. A separate cohort of consecutive patients with biopsy-proven DCIS presenting as masses was then reviewed to assess the proportion of masses with an echogenic rind and upgrade to invasive malignancy on surgical pathology. Masses with an echogenic rind were associated with invasive breast cancer (P = 0.001) and had higher upgrade rates when core biopsy revealed DCIS (P = 0.04). Masses in both cohorts did not vary by size (P = 0.41), shape (P = 0.44), or margin (P = 0.62), or demonstrate significant differences in receptor status (P = 0.98) or Nottingham grade (P = 0.85). Presence of an echogenic rind surrounding a mass is associated with invasive malignancy and correlates with upgrade of DCIS to invasive cancer on surgical pathology but otherwise offers minimal additional diagnostic or prognostic utility to radiologists.
-
7. Coronary Plaque Burden, Distribution, and Perivascular Fat Characteristics in Patients with Diabetes Mellitus: A Coronary CT Angiography Study.
7. 糖尿病患者冠状动脉斑块负荷、分布及血管周围脂肪特征:一项冠状动脉CT血管造影研究PMID:日期:2026-09-29Comparing coronary plaque distribution, plaque characteristics, and perivascular inflammation between patients with diabetes mellitus (DM) and those without metabolic disease, and further exploring these features across different metabolic phenotypes of DM. In addition, evaluating the performance of fat attenuation index (FAI) measured at different spatial scales in capturing diabetes-related perivascular inflammatory changes. 324 Patients undergoing CCTA were retrospectively enrolled and classified into a DM group and a non-metabolic disease (non-metabolic syndrome) group. The DM group further stratified into four subgroups based on hypertension and hyperlipidemia. We assessed coronary plaque characteristics, CT-derived fractional flow reserve (CT-FFR), and perivascular fat parameters at periplaque, 1 mm, and 2 mm distances. Multivariable logistic regression was used to identify factors independently associated with DM. Generalized estimating equation (GEE) models evaluated plaque distribution across coronary branches, and the interaction between DM and plaque characteristics. Compared to the non-metabolic syndrome group, patients with DM had higher BMI, hs-CRP, TG, and glucose levels, lower HDL-C and CT-FFR, and higher FAI-2mm distal (all p < 0.05). The association between FAI-2mm distal and DM remained significant after adjustment for systemic inflammatory and metabolic factors. At the patient level, mean and maximum FAI differed between groups at specific distal periplaque regions, whereas FAI of the most-stenotic and highest-risk plaques did not. Among DM phenotypes, periplaque FAI differed significantly, with higher values observed in the isolated-DM and DM-HL-HTN groups than in selected single-comorbidity groups. GEE analysis accounting for patient-level clustering showed that DM was associated with the presence of coronary plaque (p < 0.001), but did not significantly modify its distribution across coronary locations. CT-FFR was significantly associated with FAI values (p<0.05), whereas diabetes status did not significantly modify this association (p>0.05). Napkin-ring sign was associated with higher FAI and showed a significant interaction with diabetes status (p < 0.001). FAI analysis reveals distinct inflammatory patterns and heterogeneity among diabetic phenotypes. Higher perivascular FAI in the coronary segment located 2 mm distal to the plaque was showed in DM patients, while the biological significance of this spatial pattern remains uncertain. Diabetes increased overall coronary plaque burden without altering vessel-specific distribution patterns. Napkin-ring sign was associated with higher FAI and showed a significant interaction with diabetes status.
-
8. An AI-Powered Voice-Driven Oral Board Examination Simulator for Radiology Training: A Pilot Feasibility Study.
PMID:日期:2026-09-29The American Board of Radiology is transitioning radiology certifying examinations to a virtual oral format in 2028, creating need for scalable preparation tools, as traditional mock orals require significant faculty resources. To develop and evaluate feasibility, usability, and educational value of an AI-powered voice-driven oral board examination simulator. In this IRB-approved single-institution pilot (May 2025-June 2026), we developed RadBoardsAI, a web-based platform with real-time voice interaction (Whisper, GPT-4o, text-to-speech), deterministic examiner constraints, and ABR sample cases. Residents (PGY-2-PGY-5) completed simulated examinations and pre/post surveys. Eight completed baselines; four (50%) post-intervention; 75% had no prior mock oral experience. Baseline confidence (2.57 ± 0.98) and preparedness (2.14 ± 0.90) were low, with moderate stress (3.14 ± 0.90). Post-intervention (n = 4) showed improved confidence (3.50; SMD = + 0.95) and preparedness (3.50; SMD = + 1.51), decreased stress (1.50; SMD = -1.83), and mean SUS 70.0 ± 15.1 (Good). Qualitative feedback identified image labeling and case expansion as priorities. In this pilot feasibility study, RadBoardsAI demonstrates technical feasibility and acceptability among radiology residents, addressing faculty constraints while providing standardized oral board preparation.
-
9. Accelerating 7T Gradient-Echo Brain MRI With Generative AI Denoising.
PMID:日期:2026-09-26This study aimed to efficiently denoise short 7 T MRI acquisitions to achieve the image quality of longer scans using a generative Artificial Intelligence (AI) model. A 7T Conditional Diffusion Model (7TCDM) was trained on an in-house 7T dataset of 11 examinations consisting of multi-repetition 2D T2-weighted gradient-echo acquisitions. The model utilized native single-acquisition 2D reconstructions, using multi-repetition images as a reference to guide denoising and enhance signal-to-noise ratio and contrast. Performance was compared to the same single-acquisition reconstruction either unprocessed or enhanced by a similarly trained convolutional neural network, vision transformer, and generative adversarial network, using Mean Squared Error (MSE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), and comprehensive neuroradiologic ratings. 7TCDM was tested on 2D T2-weighted gradient-echo images from 19 participants: eight healthy controls, six individuals with mild cognitive impairment, and five with Alzheimer's disease. Referencing the multi-repetition reference standard, 7TCDM improved the single-acquisition original image by 31.7% in MSE, 4.9% in PSNR, and 7.5% in SSIM, outperforming all other models in all metrics (P < 0.001). Expert rater evaluations confirmed superior image quality, with significantly enhanced detail (P < 0.001) and contrast preservation (P < 0.001) for the hippocampi, for white matter lesions, and for small cortical veins. Generative AI denoising provides high-quality denoised images from shorter scans, increasing the feasibility of scanning patients in shorter times while preserving essential anatomical and pathological details.
-
10. Contrast-Enhanced Ultrasound Evaluates Pathological Response Grades After Neoadjuvant Therapy in Colorectal Liver Metastases.
PMID:日期:2026-09-24Precise assessment of pathological response grades after neoadjuvant therapy in colorectal liver metastases (CRLM) is essential for facilitating individualized therapeutic decision-making. To establish a one-step contrast-enhanced ultrasound (CEUS) classification system to evaluate five grades of pathological response after neoadjuvant therapy in CRLM. This study was conducted with CRLM who underwent preoperative CEUS following neoadjuvant therapy from January 2023 to December 2024. Pathological response was graded according to tumor regression grade (TRG) scheme. Accordingly, CEUS five-grade patterns were established based on perfusion characteristics of wash-in at arterial-phase and washout at portal vein and late phase, including: ①Non-enhanced, ②Slow In/Slow Out, ③Slow In/Fast Out, ④Fast In/Slow Out, ⑤Fast In/Fast Out. Inter-reader agreement was assessed using Cohen's kappa. Diagnostic performance of CEUS and concurrent contrast-enhanced MRI (CEMRI) were evaluated using McNemar's test and DeLong test (TRG 1-3: favorable pathological response; TRG 4-5: poor pathological response). A total of 217 patients (mean age 58±10 years; 148 male) were enrolled into this study. CEUS five-grade patterns were strongly correlated with five TRGs (Spearman r=0.812, P<0.001). In TRG 1-2, 82.1% (46/56) of the patients showed CEUS pattern ①-②. There were 32.4% (23/71) of the patients showed pattern ③ in TRG 3. 100% (90/90) of the patients showed Pattern ④-⑤ in TRG 4-5. Inter-reader agreement was good to excellent in CEUS five-grade patterns (κ=0.768-0.896). In the head-to-head comparison (n=128), CEUS demonstrated significantly higher sensitivity (100% vs. 67.3%, P < 0.001) and accuracy (82.8% vs. 75.0%, P=0.009) but lower specificity (71.1% vs. 80.3%, P=0.012) than CEMRI in tumor response. CEUS five-grade patterns provided a non-invasive method for evaluating pathological response to neoadjuvant therapy in CRLM. These findings support further investigation of CEUS as a complementary modality to CEMRI, particularly for patients lacking baseline imaging or with contraindications to CEMRI.