Clinical Imaging临床影像学
Clinical Imaging(英文缩写 CLIN IMAG),ISSN 0899-7071,eISSN 1873-4499,中文译名:临床影像学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.420 | Q3 |
| 2022 | 2.100 | Q3 |
| 2023 | 1.800 | Q3 |
| 2024 | 1.500 | Q3 |
| 2025 | 2.200 | Q3 |
Clinical Imaging 最新收录文献
-
1. MRI-derived radiomic risk stratification for overall survival in glioma.
PMID:日期:2026-09-25MRI radiomics may capture tumor phenotypes associated with glioma aggressiveness, but many radiomic survival signatures lack independent validation. We developed a UCSF-PDGM-derived MRI radiomic score for overall survival stratification in glioma and externally tested the locked score in UPenn-GBM. This retrospective study used UCSF-PDGM as the development/internal cohort and UPenn-GBM as the independent external validation cohort. The UCSF dataset included 494 patients. A locked radiomic score derived from T1 contrast-enhanced/T1GD and FLAIR features was applied directly to UPenn-GBM without feature reselection, coefficient refitting, or retraining. External validation used automated segmentations as the primary analysis and manual segmentations as a sensitivity analysis. Cox regression, Kaplan-Meier analysis, concordance-index and model comparisons, bootstrap resampling, segmentation correlation and agreement analyses, calibration, and decision curve analysis were performed. In UCSF-PDGM, radiomic score was significantly associated with overall survival (HR approximately 1.66, p = 0.000176). In UPenn-GBM, the score was applied to 581 patients and was associated with worse overall survival (HR 1.63, 95% CI 1.30-2.05, p < 0.005; C-index 0.56). Kaplan-Meier analysis showed worse survival in the high-risk group (log-rank p < 0.001). In multivariable analysis, radiomic score remained independently associated with survival after adjustment for age, IDH mutation status, and extent of resection (adjusted HR 1.35, 95% CI 1.04-1.77, p = 0.03). Automated- and manual-derived scores were strongly correlated among overlapping cases (Pearson r = 0.84; Spearman ρ = 0.83) and showed strong absolute agreement (ICC = 0.837). The locked UCSF-derived MRI radiomic score showed a reproducible association with overall survival in the independent UPenn cohort and remained independently associated with survival after clinical adjustment. However, standalone and incremental discrimination were modest. These findings support further study of the score as a potential noninvasive prognostic biomarker rather than a stand-alone clinical prediction tool.
-
2. From alternators to adaptive intelligence: Reimagining radiology education through integrated AI learning platforms.
2. 从交流发电机到自适应智能:通过集成人工智能学习平台重新构想放射学教育PMID:日期:2026-09-24Radiology education continually evolves alongside advances in imaging technology, from film-based alternators to picture archiving and communication systems (PACS), voice recognition, and modern enterprise imaging environments. Artificial intelligence (AI) now represents the next major transformation in radiology training, with the potential to fundamentally reshape how residents acquire knowledge, develop reporting skills, receive feedback, and prepare for independent practice. While current AI educational efforts often focus on didactic literacy surrounding machine learning concepts, emerging opportunities extend far beyond passive instruction. This article describes a forward-looking framework for AI-integrated radiology education through two prototype platforms currently under development at our institution: RadCase and RadIntel. RadCase is an AI-driven educational ecosystem designed to curate institution-specific teaching files directly from PACS, integrate vetted educational resources, personalize learning pathways, and provide adaptive quiz-based reinforcement tailored to trainee level and performance. RadIntel is a complementary AI-enabled reporting intelligence platform designed to evaluate radiology reports using structured rubrics informed by American College of Radiology (ACR) Practice Parameters and Technical Standards (PP&TS) and Radiological Society of North America (RSNA) reporting guidance while simultaneously providing educational feedback, reporting analytics, and clinically oriented visualization tools. Together, these systems are designed to transition radiology education from static and asynchronous teaching models toward dynamic, individualized, data-driven learning environments. Beyond anticipated efficiency gains, these platforms are expected to improve resident engagement, standardize feedback, enhance oral board preparation, identify knowledge gaps, and support scalable education as clinical demands continue to increase. Prospective studies are planned to evaluate these anticipated benefits.
-
3. Radiologists for global health: A guide to public charities and private foundations in radiology.
PMID:日期:2026-09-23Organizations in radiology with public service missions serve as unique avenues for radiologists to give back to global communities. Broadly, these organizations can be categorized as public charities and private foundations. Public charities are characterized by direct engagement with underserved populations through volunteers and staff. Key examples within the field of radiology include RAD-AID, ROAD2IR, Imaging the World (ITW), the International Society of Radiology (ISR), Radiologists Without Borders (RWB), Project C.U.R.E., and Ultrasound Networking Interpretation Training & Supply for Underserved Areas (UNITSUSA). They receive funding from individual donations, government grants, corporate sponsorships, and also enjoy significant tax advantages. Private foundations, in turn, typically begin with an infusion of capital by a single benefactor who retains significant control over the organization, with less tax benefits relative to public charities. In addition to private and public foundations, non-profit foundations exist as part of professional radiological societies, including The Radiological Society of North America (RSNA) Foundation, The American College of Radiology Foundation (ACRF), and The Society of Interventional Radiology (SIR) Foundation, as well as radiology-related efforts within other large private foundations. These organizations tend to indirectly serve those in need through grant funding and investments in large-scale initiatives. This article provides an overview of non-profits related to radiology and discusses paths for radiologists to join existing ones or establish their own.
-
4. A scoring model using conventional ultrasound and contrast-enhanced ultrasound to identify benign ACR TI-RADS 4 and 5 thyroid nodules: A retrospective clinical study.
PMID:日期:2026-09-17The limited specificity of ACR TI-RADS in high-risk categories 4 and 5 results in a substantial proportion of benign nodules being misclassified as suspicious, contributing to unnecessary surgeries. This study aimed to develop and validate a scoring model based on conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS) to better identify benign nodules that may be spared from thyroidectomy. A total of 380 patients with surgically confirmed thyroid nodules (152 benign, 40.0%; 228 malignant, 60.0%) were retrospectively enrolled (January 2021-February 2026). Using stratified random sampling (pathological result, ACR TI-RADS category, background thyroid status), patients were divided into a training set (n = 259) and a validation set (n = 121) at a 7:3 ratio. Independent predictors were identified by multivariate logistic regression, and a scoring model was constructed. Model performance was evaluated by receiver operating characteristic curves, and the area under the curve (AUC), sensitivity, specificity, and accuracy were compared with the ACR TI-RADS using the TR5 cutoff. All validation was performed as internal split-sample validation from a single center. In the validation set, the US+CEUS score achieved an AUC of 0.872, sensitivity of 94.4%, and specificity of 75.5%, showing higher performance than ACR TI-RADS (AUC 0.720, sensitivity 88.9%, specificity 55.1%). The US-only score (AUC 0.861, sensitivity 91.7%, specificity 67.3%) served as an alternative when CEUS was unavailable. Subgroup analysis showed that the US+CEUS score achieved a specificity of 92.6% in TR4 nodules and a sensitivity of 96.9% in TR5 nodules. The US+CEUS scoring model showed good diagnostic performance in this single-center internal validation cohort of ACR TI-RADS 4/5 nodules, suggesting its potential to reduce unnecessary surgeries by identifying benign nodules that may be spared from thyroidectomy. External validation in prospective, unselected populations is warranted before clinical implementation. The US-only score provides a practical alternative when CEUS is not available.
-
5. Dynamic CT angiography assessment of the suprascapular artery in thoracic outlet syndrome: anatomy, anatomical variants, and dynamic stenosis.
PMID:日期:2026-09-17To evaluate the anatomy and dynamic behavior of the suprascapular artery (SSA) in patients undergoing dynamic CT angiography (DCTA) for thoracic outlet syndrome (TOS) and to investigate its relationship with subclavian artery (SCA) stenosis. In this retrospective single-center study, consecutive DCTA examinations performed for suspected TOS between March 2023 and December 2024 were reviewed. SSA origin, course relative to the costoclavicular space (CCS), relationship with the brachial plexus, and the presence of SSA stenosis or occlusion were independently assessed by two blinded radiologists across five dynamic acquisition volumes. Associations between SSA abnormalities and symptom type, scapulalgia, and SCA stenosis were analyzed. A total of 193 thoracic outlets were included. The SSA originated from the thyrocervical trunk in 77.7% of cases and coursed through the CCS in 77.7%. Contact between the SSA and brachial plexus was observed in 30.6% of thoracic outlets, although no neural compression was identified. At least one SSA stenosis or occlusion was detected in 25.9% of thoracic outlets and was significantly associated with symptomatic outlets (odds ratio [OR], 4.16; P = 0.006), scapulalgia (OR, 2.44; P = 0.012), CCS course (OR, 2.56; P = 0.049), thyrocervical trunk origin (OR, 4.31; P = 0.005), concomitant SCA stenosis (OR, 7.20; P < 0.001), and acquisition volume (P < 0.001). The SSA frequently traverses the CCS and commonly demonstrates dynamic stenosis or occlusion in patients with suspected TOS. Its association with symptoms, scapulalgia, and SCA stenosis suggests that the SSA may represent a previously underrecognized imaging marker of thoracic outlet hemodynamics.
-
6. Patient acceptance of AI-based breast cancer risk assessment is a starting point, not an endpoint.
PMID:日期:2026-09-17该文献暂无摘要。
-
7. Cases of mistaken identity: Avoiding diagnostic pitfalls in pediatric sonography.
PMID:日期:2026-09-16Ultrasound (US) is the preferred first-line imaging modality for many pediatric abdominopelvic pathologies because of its portability, lack of ionizing radiation, and real-time imaging capability. However, pediatric sonography remains highly operator dependent and vulnerable to diagnostic pitfalls related to scanning technique, patient cooperation, body habitus, and familiarity with pediatric anatomy. This pictorial essay presents a series of illustrative pediatric US cases that were initially misrepresented and, at times, inadequately imaged by sonographers, with the correct diagnoses subsequently established following review, additional imaging, and discussion with pediatric radiologists. Cases include gastroesophageal junction mistaken for pylorus, ruptured appendicitis mistaken for ileocolic intussusception, terminal ileum mistaken for appendix, thickened ileocecal valve mistaken for intussusception, transient small bowel intussusception mistaken for ileocolic intussusception, canal of Nuck hernia mistaken for necrotic lymph node, torsion of epididymal appendix mistaken for epididymitis, and periappendiceal collection mistaken for ovary. Common contributing factors included failure to establish appropriate anatomy, focus on a single imaging plane, incomplete dynamic assessment, and inadequate Doppler evaluation. For each case, key imaging clues and practical strategies to avoid similar pitfalls are reviewed. These cases emphasize the importance of systematic scanning technique, dynamic cine with multiple plane assessment, and close communication between sonographers and pediatric radiologists, particularly in the age of remote imaging. Increased awareness of these "mistaken identity" scenarios may improve diagnostic accuracy, reduce unnecessary intervention, and enhance confidence in pediatric US interpretation. This educational review may be particularly useful for general radiologists, radiology residents, pediatric radiology fellows, and pediatric sonographers.
-
8. Subperiosteal lesions: a radiologic spectrum of pathologies and diagnostic considerations.
PMID:日期:2026-09-15Subperiosteal lesions encompass traumatic, infectious, benign neoplastic, and malignant processes arising between the periosteum and the underlying cortex. Because the periosteum is more loosely adherent in children and young adults, several entities are encountered more often in paediatric populations. Accurate diagnosis requires integration of imaging characteristics such as lesion location, composition and cortical response, and relevant clinical context. This imaging-focused review discusses subperiosteal haematoma, abscess, ganglion, osteoid osteoma, osteoblastoma, aneurysmal bone cyst, lipoma, haemangioma, chondroid lesions, Ewing sarcoma, osteosarcoma and metastases. We lead with a practical imaging diagnostic algorithm and use the accompanying tables as the core summary, with the subsequent discussion emphasising the principal imaging discriminators and differential diagnoses. Tissue diagnosis is discussed where imaging is indeterminate or an aggressive surface tumour is suspected.
-
9. A personalized breast prosthesis volume customization method based on preoperative MRI imaging for post-mastectomy breast cancer patients.
PMID:日期:2026-09-14Conventional breast prosthesis selection for mastectomy patients faces poor fitting accuracy, privacy exposure and complicated operation. In this preliminary feasibility study, we proposed and feasibility-verified a personalized volume customization method based on preoperative MRI and publicly available open-source tooling. A representative cohort of three breast MRI cases with distinct breast volumes and bilateral symmetry characteristics were analyzed with fully open-source 3D Slicer for segmentation, 3D reconstruction and voxel-based volumetric measurement, using the public Duke-Breast-Cancer-MRI dataset. Intra-method agreement between the voxel-based label mapping method and the closed surface fitting method was less than 0.5% across all cases, and the resulting per-breast mean volumes were 1228.15, 507.49, and 635.08 mL (bilateral totals 2456.30, 1014.97, and 1270.16 mL), spanning a wide spectrum from large to small breast sizes and thereby providing a diversified basis for validating the robustness of the proposed method across different anatomical types. Breast volume is known to vary widely across individuals and populations, so the three case volumes are reported here as descriptive findings rather than as validation against any external reference. Target volumes were determined according to unilateral and bilateral mastectomy scenarios. High-quality 3D models and accurate volume quantification were obtained successfully, and a mapping model linking individual volumetric parameters to commercial prosthesis sizes was constructed as a step toward clinical translation. This non-invasive method is privacy-friendly, posture-independent in terms of volume, and avoids postoperative physical exposure, thereby relieving psychological distress. The guiding "volume conservation with morphological assessment" principle adopted in this study informs personalized external breast prosthesis selection; its longer-term morphological-remodeling dimension (patient-specific prosthesis design) lies beyond this feasibility study and is reserved for future work, offering a reproducible, privacy-friendly methodological framework for prospective validation in larger cohorts.
-
10. Assessment of coronary plaque progression using the plaque-specific pericoronary fat attenuation index and fractional flow reserve.
PMID:日期:2026-09-11This study evaluated the plaque-specific fat attenuation index (FAI), a patient-level measure representing the weighted average FAI across all detected coronary plaques, and computed tomography fractional flow reserve (CT-FFR) for predicting coronary plaque progression (PP). This retrospective analysis included 1560 patients with suspected coronary artery disease who underwent baseline and follow-up coronary computed tomography angiography (CCTA) during January 2013-May 2023. Annual change in total plaque burden (TPB) was calculated using serial CCTA. PP was defined as ΔTPB/y greater than or equal to the median value. Univariate and multivariate logistic regression analyses identified independent PP predictors that were incorporated into an integrated prediction model. Prognostic performance of the plaque-specific FAI and CT-FFR was evaluated within this framework. In total, 380 patients [median age 61 (range: 54, 67) years; 253 males] were analyzed and equally assigned to progression and nonprogression groups. Independent predictors for PP included Δplaque-specific CT-FFR [odds ratio (95% confidence interval) = 0.879 (0.827-0.930), p < 0.001], vessel-specific CT-FFR [0.918 (0.881-0.955), p < 0.001], Δplaque-specific FAI [1.041 (1.009-1.073), p = 0.012], FAI-right coronary artery [1.033 (1.002-1.064), p = 0.034], statins [0.531 (0.331-0.852), p = 0.009], calcified volume [0.995 (0.991-0.998), p = 0.004], and plaque length [1.021 (1.009-1.033), p < 0.001]. The integrated model achieved an area under the receiver operating characteristics curve value of 0.792 (p < 0.001), significantly outperforming individual predictors (all p < 0.001, DeLong test). Overall, combining plaque-specific FAI, CT-FFR, and CCTA-derived quantitative plaque parameters improved risk stratification for PP.