Medical Dosimetry医学剂量学
Medical Dosimetry(英文缩写 MED DOSIM),ISSN 0958-3947,eISSN 1873-4022,中文译名:医学剂量学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.531 | Q4 |
| 2022 | 1.200 | Q4 |
| 2023 | 1.100 | Q3 |
| 2024 | 1.000 | Q4 |
| 2025 | 1.700 | Q3 |
Medical Dosimetry 最新收录文献
-
1. Clinical commissioning of a commercial brass GRID collimator for spatially fractionated radiotherapy.
1. 用于空间分割放疗的商用黄铜GRID准直器的临床调试PMID:日期:2026-09-26Spatially Fractionated Radiation Therapy (SFRT) delivers high-dose radiation in a GRID pattern to treat large tumors. This can be achieved using either a physical GRID block or virtual MLC-based patterns. This report presents our experience commissioning a commercial brass GRID collimator for SFRT. Commissioning was performed using a brass GRID collimator with 6 MV and 10 MV photon beams under both flattening filter (FF) and flattening filter-free (FFF) configurations. Dosimetric measurements were collected in a water phantom and compared with treatment planning system calculations. SFRT test plans were created and validated using a commercial detector array. Valley-to-peak dose ratio (VPDR) ranged from 0.20 to 0.30 (6-MV) and 0.30 to 0.37 (10-MV). The Percent depth doses were lower than those for open fields at all beam energies. Measured vs. calculated profiles agreed within ±5% in dose and 1 mm in distance for all beam energies. TPS-generated plans showed strong agreement with measured distributions, with an average gamma passing rate of 96.5% (3%/3 mm criteria). We successfully commissioned and validated a commercial GRID collimator for SFRT using 6-MV and 10-MV photon beams in both FF and FFF modes. Despite its substantial weight and limited maximum field size of 25 × 25 cm², GRID-based SFRT offers straightforward treatment planning, efficient dose delivery, and the potential to enhance tumor control through its characteristic peak-to-valley dose distribution.
-
2. Dose equivalence calculation in radiotherapy: A Call for Standardization.
2. 放射治疗中的剂量等价计算:标准化呼吁PMID:日期:2026-09-23Accurate dose equivalence calculations are essential in radiotherapy to balance tumor control with tissue preservation. Despite decades of research, clinical implementation remains highly variable. A structured workshop analysis involving radiation oncologists, medical physicists, and technicians revealed alarming heterogeneity: when applying equivalent dose models (LQ/LQL) to identical clinical scenarios, mean inter practitioner agreement reached only 25.8% (Jaccard index), with consensus as low as 10% for head-and-neck cases. Proposed dose-per-fraction adjustments for identical situations ranged from 1.8 to 2.5 Gy, representing 15 to 20% biological dose variations (Kruskal-Wallis on the distribution of proposed doses across participant responses, case 1: p=0.18 head and neck, p=0.032 breast, p=0.027 bladder; p<0.05 for the three remaining cases). This variability persists across treatment interruptions, hypofractionation, and reirradiation: nearly 50% of surveyed centers cannot compute biologically equivalent schedules using available tools. Root causes include systematic reliance on the linear-quadratic model beyond the fraction sizes for which it is best established, outdated radiobiological parameters, and omission of repopulation correction despite international guidelines. Clinical consequences are not theoretical: for a 7-day treatment gap, institutional practices vary from 1.8 to 2.5 Gy compensatory fractions, potentially resulting in 10 to 15 Gy equivalent dose differences. In reirradiation, heterogeneous dose summation compromises spinal cord protection where small errors translate to irreversible myelopathy risk. Current practice depends on local tradition rather than evidence, creating unacceptable geographic disparities. Urgent harmonization through validated models, standardized workflows with mandatory repopulation correction, voxel-based BED/EQD2 assessment, and clearly defined professional accountability is imperative to ensure consistent, safe patient care.
-
3. Endorectal balloon facilitated dose-escalation salvage radiation therapy without compromising rectal dose constraints for a solitary macroscopic recurrence in prostate bed after prostatectomy.
3. 直肠内气囊辅助的剂量递增挽救性放射治疗,在不影响直肠剂量约束的情况下,用于前列腺切除术后前列腺床孤立性宏观复发PMID:日期:2026-09-22Early salvage radiation therapy (sRT) is a potentially curative treatment for patients with recurrent prostate cancer (PC) after radical prostatectomy (RP). Total dose of 64 to 66 Gy in 32 to 33 fractions to prostate bed (PB) is commonly used in sRT for biochemical recurrence (BCR). In the event of macroscopic local recurrence (MLR), additional boost dose to MLR (total of greater than 74 Gy in 37 fractions) have shown an improved tumor control. Because MLR in PB often abuts the rectum, however, dose-escalation sRT (DE-sRT) to MLR can be limited due to exceeding rectal dose constraints resulting in suboptimal tumor control. Endorectal balloon (ERB) during definitive RT for localized intact PC has shown decreased rectal dose by pushing the posterior and lateral rectal wall away from prostate and high-dose region resulting in reduced rectal toxicity. Applying ERB in patients with previous RP can also create similar favorable anatomical changes in rectum which may allow DE-sRT to MLR in PB while limiting rectal dose. In this report, we describe our experiences of successful DE-sRT (78 Gy in 39 fractions to MLR in PB) with the novel use of EBR resulting in complete resolution of MLR in PB and undetectable PSA without rectal complications.
-
4. Effects of grid size and statistical uncertainty parameters on dose calculations using the Monte Carlo algorithm in the Monaco treatment planning system for liver stereotactic body radiotherapy.
4. 网格大小与统计不确定度参数对肝脏立体定向体部放疗中Monaco治疗计划系统蒙特卡罗算法剂量计算的影响PMID:日期:2026-09-19Stereotactic body radiotherapy (SBRT) for liver metastases requires accurate dose calculation. The Monte Carlo (MC) algorithm in the Monaco treatment planning system (TPS) provides high dose-calculation accuracy; however, user-defined grid size (GS) and statistical uncertainty (SU) settings influence computational efficiency and the reported dose distribution. This study evaluated the dosimetric effects of 4 MC parameter combinations on liver SBRT plan quality. Twenty-three patients with liver metastases treated with SBRT were retrospectively included. For each patient, 4 VMAT plans were independently optimized in Monaco TPS v5.11 using the same prescription, clinical objectives, dose constraints, and beam geometry: SU1GS2 (1% SU/2 mm GS), SU1GS3 (1% SU/3 mm GS), SU2GS2 (2% SU/2 mm GS), and SU2GS3 (2% SU/3 mm GS), yielding 92 plans. SU was specified per calculation, rather than per control point. Dosimetric parameters, final MC dose-calculation time, and patient-specific QA results were compared using repeated-measures nonparametric tests. Increasing GS from 2 mm to 3 mm significantly reduced final dose-calculation time and increased monitor units (both p < 0.001). Coarser GS increased the reported GTV D98% value but produced less favorable CI, HI, and R50 values. Higher SU increased GTV D0.03 cc and D2cm. Gamma passing rates did not differ significantly among settings at either 3%/3 mm (p = 0.733) or 2%/2 mm (p = 0.782); however, 12/20 (60%) and 10/20 (50%) measurements, respectively, met the prespecified ≥ 95% threshold. GS and SU were associated with different changes in apparent plan-quality metrics. Among the tested settings, SU1GS2 served as the reference setting and provided the most favorable dosimetric stability in this single-institution cohort; this finding should not be interpreted as a universal parameter recommendation. A passing patient-specific QA result alone is insufficient to establish dosimetric equivalence, and DVH-based evaluation remains necessary.
-
5. Dosimetric and radiobiological evaluation of a spatially fractionated core-boost strategy in lung metastases within 5 mm of the esophagus: Single-center plan-comparison study.
5. 食管5 mm范围内肺转移瘤空间分割核心推量策略的剂量学与放射生物学评估:单中心计划比较研究PMID:日期:2026-09-14For lung metastases lying within 5 mm of the esophagus, organ-at-risk dose limits often force the prescription below the ablative range, lowering biologically effective dose and tumor control. We evaluated whether a simultaneous integrated boost to the tumor core, rather than dose reduction, is dosimetrically and radiobiologically rational, and which inner-volume retraction (0.3 vs 0.5 cm) is preferable. Using deep-inspiration breath-hold planning computed tomography from 30 consecutive patients, 3 clinically deliverable 5-fraction volumetric modulated arc therapy plans were generated de novo with Monte Carlo calculation: Plan A, a fixed uniform 35 Gy reference (5 × 7 Gy) applied identically to all patients as a standardized comparator; Plan B, a 60 Gy boost to the gross tumor volume retracted 0.5 cm; and Plan C, a 60 Gy boost to the gross tumor volume retracted 0.3 cm, each with a 35 Gy shell. Tumor-control and organ-at-risk endpoints were compared (Friedman and Bonferroni-corrected Wilcoxon tests). The simultaneous integrated boost met the targeted dose-escalation goal: volume-weighted total biologically effective dose rose from 61.5 to 97.4 Gy (Plan A to Plan C; 58.5%), approaching the BED10 level associated with improved local control and modeled tumor control probability increased from 0.77 to 0.93 (15.8%; all p < 0.001). Plan C exceeded Plan B by 5.4% (p < 0.001), the gain scaling with boost-volume fraction and tumor volume. Esophageal maximum dose stayed below 35 Gy with normal-tissue complication probability rising only from 6.1% to 6.9%; mean lung dose increased from 3.60 to 5.46 Gy and the volume receiving 20 Gy to 5%, all within tolerance. High-dose spillage exceeded the 17.5 Gy threshold in 53% of Plan C plans. A 0.3 cm core boost improves modeled tumor control at an acceptable, sub-tolerance organ-at-risk cost, outperforming the 0.5 cm definition. Prospective clinical validation is warranted.
-
6. Sparing the neurovascular bundle in prostate radiotherapy: A dosimetric study.
PMID:日期:2026-09-14Prostate radiotherapy is associated with a high prevalence of erectile dysfunction (ED). Nerve-sparing prostatectomy techniques demonstrate reduced postoperative ED rates, suggesting a similar benefit may be achievable with neurovascular bundle (NVB) sparing radiotherapy. This feasibility planning study aims to comparatively evaluate various NVB sparing techniques described in the literature. This was a retrospective feasibility planning study evaluating NVB sparing techniques for localized prostate cancer treated with moderate hypofractionation of 60 Gy in 20 fractions. The Volumetric Modulated Arc Therapy (VMAT) plans compared different NVB sparing strategies: (1) Standard prostate treatment without sparing of the NVBs (SPT), (2) bilateral NVB sparing (BNS) plan, (3) BNS with reduced Planning Target Volume (PTV) margins (BSRM), and (4) unilateral NVB sparing (UNS) plan. NVB target goals were V53Gy < 70% and D < 57Gy. Dose-volume histogram endpoints were compared to the SPT plan with a Wilcoxon signed-rank test. NVB sparing plans significantly reduced radiation dose to the NVB. UNS showed the greatest NVB sparing with a relative dose reduction of 10.3%, 99.1%, and 3.4% (p<0.001) for D, V57Gy, and V53Gy, respectively. BNS had smaller NVB reductions compared to UNS, and BSRM had similar NVB sparing to BNS but greater sparing of the penile bulb, corpus cavernosa, and rectum. All sparing techniques significantly reduced PTV coverage, and while achieving PTV V57Gy > 99% was not possible with NVB sparing, PTV V57Gy remained >95% for all plans. NVB sparing radiotherapy can significantly reduce dose to the NVB; however, there is a compromise of reduced PTV coverage with unilateral sparing allowing for the greatest reduction. These findings highlight the need for further clinical investigation to establish optimal NVB dose constraints that balance improved erectile function outcomes with effective tumor control.
-
7. Re-evaluating the α/β ratio in 2026: A systematic review and quantitative reappraisal in the era of molecular radiobiology.
PMID:日期:2026-09-12The linear-quadratic (LQ) model and its derived ratio, α/β, have served as the cornerstone of radiotherapy dose-fractionation decisions. The period from 2015 to 2026 has witnessed a substantial re-evaluation of this paradigm, driven by the clinical success of hypofractionation in prostate and breast cancer, stereotactic body radiation therapy (SBRT), and radiogenomics. A systematic review with narrative synthesis was conducted to evaluate quantitative estimates of α/β derived from clinical and preclinical studies over the last decade, updating classical assumptions using modern trial data. Extensive Phase III data in prostate cancer consistently define an α/β of 1.2 to 2.0 Gy. Microscopic models in breast cancer align with an α/β of ∼2.7 Gy. Conversely, lung SBRT data present a high modeled α/β driven by hypoxia artifacts. Genomic integration via the Genomic Adjusted Radiation Dose (GARD) reveals that α/β operates as a dynamic, patient-specific phenotype. In the molecular era, static α/β assumptions must be integrated with disease-specific kinetics, microenvironmental data, and genomic intrinsic radiosensitivity.
-
8. Evaluation of feasibility DVH-guided re-optimization for RapidPlan-generated prostate VMAT plans.
PMID:日期:2026-09-10Feasibility dose-volume histogram (FDVH) can provide patient-specific information on the anatomically achievable dose range for organs at risk (OARs) and may complement knowledge-based planning using RapidPlan. This study evaluated whether FDVH-guided re-optimization can improve RapidPlan-generated prostate volumetric-modulated arc therapy (VMAT) plans. A total of 50 patients with prostate cancer treated with VMAT were included. Thirty cases were used to construct a RapidPlan model from manually generated clinical plans created with reference to FDVH, and the remaining 20 independent cases were used for evaluation. Plans generated by automatic optimization using RapidPlan were defined as KBP, whereas those re-optimized with reference to FDVH were defined as KBP+FDVH. During re-optimization, mean dose and upper generalized equivalent uniform dose were used as auxiliary DVH-based parameters. Dosimetric parameters for the planning target volume excluding the rectum (PTV-R), rectum, and bladder were compared between KBP and KBP+FDVH using the Wilcoxon signed-rank test. For PTV-R, D2% was significantly reduced with KBP+FDVH compared with KBP (63.69 Gy vs 62.35 Gy, p < 0.001), and D98% was significantly increased (59.02 Gy vs 59.24 Gy, p = 0.009). Rectal V31 Gy was significantly lower with KBP+FDVH (35.51% vs 32.03%, p = 0.010). No clear improvement was observed in bladder dose. FDVH-guided re-optimization improved PTV-R dose homogeneity and reduced the low-dose region of the rectum, suggesting that this approach may serve as an auxiliary workflow for selected RapidPlan-generated prostate VMAT plans.
-
9. Dosimetric and robustness comparison of single- and double-arc volumetric-modulated arc therapy incorporating avoidance structures for prostate cancer with simulated bilateral hip prostheses.
9. 含避让结构的单弧和双弧容积旋转调强放疗在模拟双侧髋关节假体前列腺癌中的剂量学和稳健性比较PMID:日期:2026-09-09This study compared the dosimetric performance and robustness of single-arc (SA) versus double-arc (DA) volumetric-modulated arc therapy (VMAT) incorporating avoidance structures (AS) for prostate cancer with simulated bilateral hip prostheses. A total of 15 prostate cancer cases without hip prostheses were retrospectively analyzed. Bilateral hip prostheses were simulated by assigning titanium-equivalent Hounsfield unit values to both femoral heads. Identical dose constraints and full-arc geometry with AS configured to suppress beam entry through prosthetic regions were used to generate SA and DA plans. Dosimetric indices for target volumes and organs at risk were compared. Plan robustness was evaluated by simulating image-guided position correction with 5-mm and 10-mm shifts of the clinical target volume (CTV) in the anterior-posterior and superior-inferior directions; CTV D served as the primary robustness metric. Under identical planning conditions, DA demonstrated statistically superior performance for several planning target volume and rectal dose parameters; however, absolute differences were small. SA plans showed greater asymmetry in the intermediate-dose region. With posterior and inferior position corrections, DA demonstrated significantly better robustness than SA, whereas superior position correction showed only borderline significance. Absolute differences in CTV D between SA and DA under posterior and inferior position corrections were ≤0.6 Gy, indicating limited clinical relevance. No significant difference in CTV D was observed under anterior position correction. Both approaches showed reduced CTV coverage at a 10-mm anterior shift, with mean decreases of 1.7% for SA and 1.6% for DA. DA VMAT showed marginally superior robustness under posterior and inferior position corrections, whereas SA achieved comparable overall plan quality with theoretically shorter delivery times. Careful consideration of anterior internal error, including treatment planning optimization strategies accounting for hip prostheses and strict patient preparation protocols, remains crucial for both approaches.
-
10. Beam data and model validation for Elekta SRS cone collimator in 6MV and 6MVFFF beams.
10. Elekta SRS锥形准直器在6MV和6MVFFF束流下的束流数据与模型验证PMID:日期:2026-09-01This study aimed to evaluate the beam data of Elekta stereotactic radiosurgery (SRS) cone collimators for 6MV and 6MV flattening filter-free (6MVFFF) beams and to assess the feasibility of implementing a shared beam model across beam-matched linear accelerators (linacs). Percentage depth dose (PDD), beam profiles, and output factors were measured using IBA SFD and PTW microDiamond detectors for fixed (current clinical practice) and variable (previous clinical practice) jaw configurations. A Monaco X-ray voxelized Monte Carlo (XVMC)-based SRS model was developed on one linac and validated using SNC SRS MapCHECK and StereoPHAN. The model's applicability was further tested on a second linac. The depth of maximum dose (D) and PDD beyond D decreased with smaller cones, while penumbra widened for larger cones. Compared to 6MVFFF, 6MV beams exhibited 5% higher in-field off-axis ratios (OARs) and 15% higher out-of-field OARs. The output factors for 6MVFFF exceeded those of 6MV by up to 5.83% (7.5-mm cone). Fixed jaw configurations increased out-of-field OARs by 15% and output factors by 0.57% compared to variable jaws. Measurements from IBA SFD and microDiamond detectors showed excellent agreement in PDD and beam profiles, with output factors differing by less than 2.33%. The Monaco XVMC model achieved >99.10% gamma passing rates (2%/2 mm) and <3.0% central axis point dose differences during validation. Both linacs demonstrated minimal discrepancies when using shared beam models. Fixed jaw settings increase out-of-field scatter and output factors for cones <35 mm. The comprehensive beam data for 6MV and 6MVFFF beams presented in this study provide a valuable reference for commissioning and quality assurance (QA) in clinical practice. IBA SFD and microDiamond detectors are suitable for SRS cone beam data collection and QA when appropriate corrections as per TRS-483 are applied. Shared beam models are feasible for beam-matched linacs, offering a streamlined approach to clinical work.