Brachytherapy近距离放射治疗
Brachytherapy(英文缩写 BRACHYTHERAPY),ISSN 1538-4721,eISSN 1873-1449,中文译名:近距离放射治疗 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.441 | Q3 |
| 2022 | 1.900 | Q3 |
| 2023 | 1.700 | Q3 |
| 2024 | 1.800 | Q3 |
| 2025 | 1.700 | Q3 |
Brachytherapy 最新收录文献
-
1. Development and clinical evaluation of an automatic verification system for Oncentra brachytherapy treatment planning.
PMID:日期:2026-10-03Current manual workflows for verification of high-dose-rate (HDR) intracavitary and hybrid interstitial brachytherapy are labor-intensive and susceptible to errors. This study developed a fully automated verification system to evaluate plan integrity, quality, and dosimetric accuracy, with the aim of improving patient safety and clinical workflow efficiency. Featuring an automated verification pipeline for treatment plan integrity and a quality evaluation module, the system assesses key metrics: patient data, treatment parameters, applicator information, the number of CT slices, and volumetric and dosimetric constraints for all volumes of interest (VOIs). Additionally, an independent dose calculation based on the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism is incorporated. A total of 79 cases successfully passed the integrity check, and the remaining six triggered system-generated warnings. Quality assessment confirmed that the majority of plans met all clinical constraints, with only minor clinically acceptable deviations observed in isolated cases. A mean Gamma passing rate of 98.70% (3%/2 mm criterion) was obtained in independent plan dose verification, and a positive correlation with the target volume was observed. The implemented automated verification system is proven to be reliable and practical for clinical use. It enhances the efficiency of intracavitary and hybrid interstitial HDR brachytherapy plan quality assurance while effectively mitigating the risks associated with human error.
-
2. Hypofractionated 44 Gy in 20 fractions versus conventional chemoradiation in cervical cancer: 2-year results of the randomized HYPOCx-iRex trial with an exploratory pooled analysis of a single-institute EMBRACE-II cohort.
2. 宫颈癌低分割44 Gy/20次与传统放化疗比较:随机HYPOCx-iRex试验的2年结果及单中心EMBRACE-II队列的探索性汇总分析PMID:日期:2026-10-01To evaluate 2-year late gastrointestinal (GI) toxicity, oncologic outcomes, and cost-effectiveness of hypofractionated concurrent chemoradiation with 44 Gy in 20 fractions (44 Gy/20F; HYPO) versus conventional fractionation (45 Gy/25F; CVRT + EMB) for locally advanced cervical cancer (LACC). The primary analysis was the randomized HYPOCx-iRex comparison (HYPO n = 21 vs. CVRT n = 19). A pre-planned pooled analysis additionally incorporated a concurrent, nonrandomized single-institute EMBRACE-II cohort (EMB n = 28; total n = 68). Late GI toxicity was graded by CTCAEv5.0. Dose-toxicity analysis used Cox and Probit regression to identify the effective dose associated with 10% toxicity probability (ED10). The indirect ratio of excess dose volume at 60 Gy EQD2 (iRex60) was evaluated as a brachytherapy (BT) conformity index. Locoregional control (LRC) and overall survival (OS) were estimated by Kaplan-Meier. Incremental cost-effectiveness ratios (ICERs) were calculated from provider and societal perspectives. Median overall treatment time was 39 versus 46 days in HYPO versus CVRT+EMB (p < 0.001). Late GI toxicity was numerically higher in HYPO (2-year Gr ≥2: 23.8% vs. 10.8%, pLR = 0.168; Gr ≥3: 19.1% vs. 5.3%, pLR = 0.066); iRex60 was identified as an independent predictor in multivariable regression (ED10 = 1.6 and 1.85 for Gr ≥2/Gr ≥3; proposed cut-off iRex60 <1.7). Favorable but nonsignificant trends in LRC (95.2% vs. 77.5%; HR = 0.43, pLR = 0.260) and OS (100% vs. 76.8%; HR = 0.22, pLR = 0.107) were observed. The 44Gy/20F regimen demonstrated dominant cost-effectiveness. Hypofractionated chemoradiation achieved LRC and OS comparable to conventional fractionation with shorter treatment time and lower cost. The higher late GI toxicity observed with hypofractionation is clinically meaningful without statistical significance. Further optimization of brachytherapy conformity and low-to-intermediate dose constraints is proposed before clinical adoption. The iRex60 threshold and the cost-effectiveness findings are hypothesis-generating and need further validation.
-
3. Long-term outcome after partial breast irradiation with interstitial multi-catheter high-dose-rate brachytherapy: Results from a Phase II prospective study with extended follow-up.
3. 间质多导管高剂量率近距离放疗部分乳腺照射后的长期结局:一项延长随访的II期前瞻性研究结果PMID:日期:2026-09-26To assess late toxicities, cosmesis, and oncological outcomes in patients treated with Partial Breast Irradiation (PBI) using interstitial multi-catheter high dose-rate brachytherapy. From 2003 to 2023, 292 patients were enrolled in a prospective observational study (follow-up up to 20 years). age ≥40 years; ECOG 0-2; ductal carcinoma in situ; invasive non lobular carcinoma; tumor size ≤2.5 cm; negative axillary lymph nodes; surgical margins ≥2 mm. PBI dose was 32 Gy in 8 fractions over 4 days. Invasive carcinoma accounted for 92.1% of cases. Late toxicities (mainly telangiectasia, fibrosis, liponecrosis) occurred in 100/286 patients evaluated (35%). Cosmetic outcomes were rated as excellent/good in 96% of cases. Ipsilateral breast tumor recurrence occurred in 10 patients (3.4%) with a 5-year cumulative incidence of 1.8% and 3.8% at 10 and 15 years. Breast cancer-free specific survival was 98.4% after 5 years, 95.7% after 10 years, and 94% after 15 years. Overall survival was 93% after 5 years, 69% after 10 years, and 53.4% after 15 years. PBI using interstitial multi-catheter high dose-rate brachytherapy is effective and well-tolerated for selected early-stage breast cancer showing excellent long-term toxicity, cosmetic profiles, and outcomes.
-
4. High-dose-rate brachytherapy boost with external beam radiotherapy for localized prostate cancer: Long-term outcomes and toxicity in 607 predominantly high-risk patients.
4. 高剂量率近距离放射治疗联合外照射放疗用于局限性前列腺癌:607例主要为高危患者的长期疗效和毒性PMID:日期:2026-09-26[中文摘要] 目的:报告局限性前列腺癌患者接受外照射放疗(EBRT)联合单次大剂量近距离放疗推量(HDR-BTB)后的长期疗效和晚期毒性,并探讨HDR-BT序贯方式及风险分层的影响。方法:回顾性分析607例(2012-2023年)接受EBRT(37.5 Gy/15次或46 Gy/23次)联合15 Gy HDR-BTB治疗的男性患者,按CPG、NCCN和ISUP分级进行分层。主要终点为bPFS和MFS;次要终点为OS和PCSS。晚期毒性采用CTCAE v5标准分级。结果:中位随访70个月;73.4%为NCCN高危,67%为CPG 4-5。6年结果:bPFS 94.1%,MFS 94.2%,OS 92.7%,PCSS 98.1%。ISUP分级升高与所有终点显著相关(HR:OS 1.3,PCSS 3.2,MFS 1.7,bPFS 1.6)。ISUP 5级患者预后最差(6年:OS 90.3%,PCSS 93.5%,MFS 88.6%,bPFS 85.2%)。6年bPFS:中危不利组为99.3%,高危组为89.7%(HR 7;95% CI 1.7-28.7;p=0.007)。晚期≥3级胃肠道/泌尿生殖系统毒性分别为0.5%/2.1%;尿道狭窄2.5%;需使用尿垫的尿失禁1.8%。HDR-BT序贯方式不影响疗效。结论:15 Gy HDR-BTB联合EBRT在该以高危为主的队列中提供了极佳的疾病控制,且严重晚期毒性较低。ISUP分级是最强的预后因素。治疗序贯方式不影响疗效,支持治疗安排的灵活性。
[英文摘要] To report long-term outcomes and late toxicity after external beam radiotherapy (EBRT) with single-fraction high-dose-rate brachytherapy boost (HDR-BTB) for localized prostate cancer, examining HDR-BT sequencing and risk stratification. We retrospectively analyzed 607 (2012-2023) men treated with EBRT (37.5 Gy/15 or 46 Gy/23 fractions) and 15 Gy HDR-BTB, stratified by CPG, NCCN, and ISUP grade. bPFS and MFS; secondary endpoints: OS and PCSS. Late toxicities were graded using CTCAE v5. Median follow-up was 70 months; 73.4% were NCCN high-risk, 67% CPG 4-5. Six-year outcomes: bPFS 94.1%, MFS 94.2%, OS 92.7%, PCSS 98.1%. Increasing ISUP grade was significantly associated with all outcomes (HR 1.3 OS, 3.2 PCSS, 1.7 MFS, 1.6 bPFS). ISUP 5 had the poorest outcomes (6-year: OS 90.3%, PCSS 93.5%, MFS 88.6%, bPFS 85.2%). Six-year bPFS was 99.3% intermediate-unfavorable vs 89.7% high-risk (HR 7; 95% CI 1.7-28.7; p=0.007). Late grade ≥3 GI/GU toxicity: 0.5%/2.1%; urethral stricture 2.5%; pad-requiring incontinence 1.8%. HDR-BT sequencing did not affect outcomes. 15 Gy HDR-BTB with EBRT provides excellent disease control with low severe late toxicity in this predominantly high-risk cohort. ISUP grade was the strongest prognostic factor. Treatment sequencing did not affect outcomes, supporting scheduling flexibility.
-
5. High-dose-rate prostate brachytherapy imaging optimization: A motorized sagittal three-dimensional ultrasound acquisition system.
5. 高剂量率前列腺近距离放射治疗成像优化:电动矢状面三维超声采集系统PMID:日期:2026-09-26High-dose-rate prostate brachytherapy (HDR-BT) relies on precise three-dimensional (3D) ultrasound imaging for treatment planning. Sagittally reconstructed 3D (SR3D) ultrasound images have been shown to reduce dosimetric uncertainty compared to axial approaches but are not broadly implemented due in part to image quality degradation and variability caused by non-uniform manual probe rotation during acquisition. We aimed to develop a system enabling motorized SR3D ultrasound acquisitions with the CIVCO EX3 stepper and evaluate improvements in image quality and scan variability. The system was developed, allowing for automated rotation of a housed transrectal ultrasound probe in the CIVCO EX3 stepper. Image quality was assessed by comparing motorized and manual SR3D acquisitions of a wire phantom against an ideal clinical reference (slow manual scan) using peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and multi-scale SSIM (MS-SSIM) using a variety of scan speeds (2-27.5°/s). Additionally, quantitative metrics such as axial and elevational resolution and distance errors, as well as volume errors were compared between the two acquisition methods across two operators. Motorized scans were of greater similarity to an ideal reference when compared to manual acquisition regardless of acquisition speed. Manual scans showed significantly higher variability for elevational distance errors and volume errors. Additionally, manual scans had significant inter-operator variability which was not present in the motorized acquisitions. The motorized attachment for SR3D acquisition reduced image variability and improved image quality. Through these improvements, this system may encourage broader use of sagittal reconstruction in HDR-BT, potentially improving patient outcomes.
-
6. Brain brachytherapy treatment planning and delivery: A competency-based framework for contemporary multidisciplinary practice.
PMID:日期:2026-09-18Brain brachytherapy remains a specialized but important component of modern neuro-oncologic care. Following the introduction of contemporary cesium-131 (Cs-131)-based platforms, intracranial brachytherapy has seen renewed growth and increasing adoption for recurrent and newly diagnosed brain metastases, recurrent glioblastoma, recurrent meningioma, and selected other intracranial tumors in which immediate focal irradiation may be advantageous. This article outlines core competencies for brain brachytherapy planning and delivery, with emphasis on contemporary multidisciplinary practice. It is intended for clinicians, medical physicists, trainees, neurosurgeons, radiation oncologists, and teams involved in developing or implementing intracranial brachytherapy programs. Key domains include patient and platform selection, imaging and target delineation, treatment planning, prescription strategy, operative workflow, radiation safety, quality assurance, and postimplant verification. Brain brachytherapy is best understood as a multidisciplinary procedural competency rather than a narrow planning exercise. Because prescription approaches, dosimetric reporting, dose constraints, and outcome-linked planning thresholds remain incompletely standardized, a competency-based framework may support training, communication across specialties, and safe program expansion.
-
7. Dosimetric and therapeutic effectiveness of high-dose-rate radionuclide sources in breast cancer brachytherapy: A systematic review.
7. 高剂量率放射性核素源在乳腺癌近距离放射治疗中的剂量学与治疗有效性:一项系统评价PMID:日期:2026-09-16High-dose-rate (HDR) brachytherapy is a widely used treatment modality for breast cancer, providing highly localized radiation delivery with improved normal tissue sparing. The choice of radionuclide source plays an important role in determining dosimetric characteristics and the available evidence for clinical effectiveness. This systematic review aims to evaluate and compare the dosimetric properties and therapeutic effectiveness of commonly used HDR radionuclide sources like Iridium-192 (¹⁹²Ir), Cobalt-60 (⁶⁰Co), and Ytterbium-169 (¹⁶⁹Yb) in breast cancer brachytherapy. A systematic literature search was conducted across PubMed, Scopus, Embase, and Google Scholar for studies published between 2005 and 2026. Studies reporting quantitative dosimetric parameters and clinical outcomes for HDR brachytherapy were included. Data extraction focused on TG-43 parameters, dose-volume measurements, and clinical endpoints. Study selection followed PRISMA guidelines. Sixteen studies met the inclusion criteria, comprising randomized phase three trials (GEC-ESTRO 10-year update), 30-year phase two results, retrospective cohort analyses, and Monte Carlo simulations. The dose rate constant (Λ) was similar among radionuclides (approximately 1.08-1.20 cGy·h⁻¹·U⁻¹). However, substantial differences were observed in dose gradients and tissue penetration. ¹⁶⁹Yb demonstrated the steepest dose fall-off and superior organ-at-risk sparing due to its low average photon energy. ⁶⁰Co, provided deeper tissue penetration and greater robustness to tissue heterogeneity. ¹⁹²Ir offered an optimized dosimetric profile and the most extensive clinical validation. Robust clinical outcome data were available for ¹⁹²Ir, demonstrating local control rates exceeding 90%. Limited clinical evidence exists for ⁶⁰Co, while evidence for ¹⁶⁹Yb is currently restricted to dosimetric and Monte Carlo investigations. Emerging dosimetric innovations included deep learning-based dose prediction and model-based dose calculation algorithms. ¹⁹²Ir remains the standard HDR radionuclide, supported by the strongest long-term clinical evidence for target coverage, local control, toxicity, and cosmetic outcomes. Treatment-planning studies indicate that ⁶⁰Co provides dosimetric performance comparable to ¹⁹²Ir, whereas evidence for ¹⁶⁹Yb is currently limited to dosimetric and Monte Carlo investigations that suggest potential organ-at-risk sparing without clinical validation. These findings support a personalized approach to radionuclide selection based on clinical evidence, treatment objectives, and treatment geometry. Additional prospective clinical studies, particularly for ¹⁶⁹Yb and APBI-specific applications of ⁶⁰Co, are needed to establish long-term clinical outcomes.
-
8. Short course versus conventional interventional radiotherapy (brachytherapy) regimen in locally advanced cervical cancer: A randomized clinical trial.
8. 局部晚期宫颈癌短程与常规介入放疗(近距离放疗)方案的比较:一项随机临床试验PMID:日期:2026-09-10To evaluate whether reducing overall treatment time (OTT) by shortening interventional radiotherapy (IRT; brachytherapy) duration affects outcomes in patients with locally advanced cervical cancer undergoing definitive chemoradiation. In this randomized clinical trial, conducted in 2016-2017, 75 patients with stage IB2-IVA cervical cancer were enrolled. The intervention group (n = 41) completed high-dose-rate IRT within 1 week, whereas the control group (n = 34) received the conventional 3-week schedule. The primary endpoint was treatment-related complications. At 5-year follow-up, 7 patients were lost to follow-up, leaving 68 patients for analysis. Median OTT was significantly shorter in the intervention group (59 vs. 64.5 days; p = 0.01), and the complete response rate was higher (53.1% vs. 31.3%; p = 0.041). No significant differences were observed in overall survival (p = 0.962) or disease-free survival (p = 0.128). Multivariate analysis identified treatment response as a significant predictor of survival, with complete response associated with improved outcomes (p < 0.001). Acute and late adverse events, including proctitis, cystitis, and vaginal hemorrhage, were comparable between groups (all p > 0.05). Shortening IRT duration reduced OTT and improved complete response without increasing treatment-related toxicity, although no significant survival benefit was observed.
-
10. Dosimetric comparison of HDR Co-60 and Ir-192 brachytherapy sources by model-based dose calculation algorithms and its clinical implication in different brachytherapy sites and techniques.
10. 基于模型的剂量计算算法对HDR Co-60和Ir-192近距离放射治疗源的剂量学比较及其在不同近距离治疗部位和技术中的临床意义PMID:日期:2026-09-07Numerous dosimetric studies have reported clinically insignificant differences between iridium-192 and cobalt-60. However, such comparison studies were conducted using TG-43 algorithms where heterogeneity is not accounted. Model based dose calculation algorithms (MBDCA) significantly improve dosimetric accuracy for iridium-192, as validated in phantom and clinical dosimetric studies. Comparative dosimetry data for head and neck (HN) cancers and soft tissue sarcomas (STS) is scarce and mostly based on Monte Carlo simulations. This study evaluates how radionuclide choice and tissue heterogeneities affect multiple tumor sites in a clinical setting. Seventy-five patients treated using TG-43 generated cobalt-60 plans were selected. For all patients, alternative equivalent plans were generated for cobalt-60 with TG-186 and for iridium-192 with both TG-43 and TG-186 algorithms. For gynecological intracavitary brachytherapy (ICBT) and combined intracavitary-interstitial brachytherapy (IC-IS BT) plans, cobalt-60 delivered up to 4.9% higher doses to organs at risk (OARs) compared to iridium-192. For pure interstitial brachytherapy (ISBT) plans iridium-192 delivered upto 5.6% higher doses to OARs compared to cobalt-60, contrary to what was observed for ICBT/IC-IS BT plans. For breast, cobalt-60 delivered higher skin doses (+2.7%) and lower rib doses (-2.8%) when using TG-43; this difference in OAR doses reduced when using TG-186. For HN and STS, OAR doses were higher upto 21.9% with iridium-192 and these differences were exacerbated when using TG-186. The dosimetric differences between radionuclides are reduced when calculated with TG-186, suggesting that the effect of tissue heterogeneity might be higher for cobalt-60 compared to iridium-192. This dosimetric study highlights that TG-186 predicts the actual doses more accurately.