Quantitative InfraRed Thermography Journal定量红外热成像杂志
Quantitative InfraRed Thermography Journal(英文缩写 QUANT INFR THERM J),ISSN 1768-6733,eISSN 2116-7176,中文译名:定量红外热成像杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.643 | Q3 |
| 2022 | 2.500 | Q2 |
| 2023 | 3.700 | Q1 |
| 2024 | 4.900 | Q1 |
| 2025 | 4.400 | Q1 |
Quantitative InfraRed Thermography Journal 最新收录文献
-
1. Thermal Image Enhancement through the Deconvolution Methods for Low-Cost Infrared Cameras.
PMID:日期:2018-05-09An infrared (IR) thermal camera may provide a tool for real-time temperature monitoring for precise disease treatment using heat generated by light-induced photosensitisers, i.e. photothermal/ablation therapies. In this work, we quantitatively demonstrated that the spatial resolution of a low-cost low-resolution IR camera could be improved via two deconvolution methods. The camera point spread function (PSF) was modeled experimentally and used to develop the deconvolution methods: 1) Richardson-Lucy blind deconvolution (BD); and 2) total variation constrained deconvolution (TD). The experimental results showed the improved spatial resolution (at 50% modulation transfer function (MTF): from the original 1.1 cycles/mm to 2.6 cycles/mm for the BD method and to 4.8 cycles/mm for the TD method) as well as contrast-to-noise ratio. With a properly chosen parameter, the TD method can resolve 1-mm size objects with the accurate temperature reading. The thermal image from the low-resolution IR camera enhanced by the TD method is comparable to that from a high-resolution IR camera. These results show that the TD method provides an effective way to improve the thermal image quality from a low-cost IR camera to monitor temperature of an object of 1-mm size, which meets the needed precision for advanced laser scanning protocols in photothermal/ablation therapies.
-
2. Rapid vs. delayed infrared responses after ischemia reveal recruitment of different vascular beds.
2. 缺血后快速与延迟红外反应揭示不同血管床的募集PMID:日期:2015-06-16Continuous infrared imaging revealed transient changes in forearm temperature during arterial occlusion, reperfusion, and recovery in a healthy subject group. Processing the imaging data with the algorithm further revealed reactive vascular sites in the skin with rapid or delayed temperature amplification. The observed temporal and spatial diversity of blood-flow-derived forearm temperature allow consideration of thermal-imaging guided placement of skin sensors to achieve enhanced sensitivity in monitoring of skin hemodynamics.
-
3. Reconstruction of Thermographic Signals to Map Perforator Vessels in Humans.
3. 重建热成像信号以绘制人体穿支血管图PMID:日期:2012-01-01Thermal representations on the surface of a human forearm of underlying perforator vessels have previously been mapped via recovery-enhanced infrared imaging, which is performed as skin blood flow recovers to baseline levels following cooling of the forearm. We noted that the same vessels could also be observed during reactive hyperaemia tests after complete 5-min occlusion of the forearm by an inflatable cuff. However, not all subjects showed vessels with acceptable contrast. Therefore, we applied a thermographic signal reconstruction algorithm to reactive hyperaemia testing, which substantially enhanced signal-to-noise ratios between perforator vessels and their surroundings, thereby enabling their mapping with higher accuracy and a shorter occlusion period.
-
4. Observing temperature fluctuations in humans using infrared imaging.
PMID:日期:2011-01-01In this work we demonstrate that functional infrared imaging is capable of detecting low frequency temperature fluctuations in intact human skin and revealing spatial, temporal, spectral, and time-frequency based differences among three tissue classes: microvasculature, large sub-cutaneous veins, and the remaining surrounding tissue of the forearm. We found that large veins have stronger contractility in the range of 0.005-0.06 Hz compared to the other two tissue classes. Wavelet phase coherence and power spectrum correlation analysis show that microvasculature and skin areas without vessels visible by IR have high phase coherence in the lowest three frequency ranges (0.005-0.0095 Hz, 0.0095-0.02 Hz, and 0.02-0.06 Hz), whereas large veins oscillate independently.